Time-dependent resistance or susceptibility of tumor cells to cytotoxic antibody after exposure to a chemotherapeutic agent.

We report that a chemotherapeutic agent (melphalan) can affect the sensitivity of tumor cells to cytotoxic antibody. Depending on the time interval between drug treatment and subsequent exposure to antibody and complement, the tumor cells can be either more resistant or more susceptible to antibody when compared to control cells. The number of tumor cells surviving the combined treatment was determined by a colony inhibition assay. The two antisera used in this study were directed against either virus-specific or myeloma protein-specific antigens on the surface of S107 murine myeloma cells; identical results were obtained with both sera. Twenty-four hours after exposure to the drug, the number of tumor cells surviving the antibody treatment increased. During this period of increased resistance, the tumor cells were temporarily arrested in the G(2) phase of the cell cycle. After this period of maximal resistance, the effect of cytotoxic antibody on the cells changed such that 4 days after melphalan treatment the cells were significantly more susceptible to the antibody than were the sham-treated control cells. The period of increased susceptibility correlated with an increased density of S107 myeloma protein and viral antigens on the surface of the tumor cells. Eight days after the drug treatment, the susceptibility of the tumor cells and the density of surface antigens both returned to normal levels. This study shows that the correct time interval between exposure to a drug and subsequent treatment with antibody is critical for maximal killing of the tumor cells. The basis for the differential sensitivity of the tumor cells to anti-body may be related to the drug-induced changes in the cell cycle and in antigen expression on the cell surface.

Antibodies, Viral↗

Identification of cell asymmetry and orientation by light scattering.

Light scattering from chicken red blood cells has been used as a model system to identify the asymmetry of cells. The histogram for forward angle light scattering for these cells is bimodal, the signal size being dependent on the cell orientation. A dual orthogonal scatter system is used to conclusively demonstrate this orientational variation in signal. A third scattering system, using a single incident beam with two orthogonal detectors, is used to further characterize the orientational variation of the scatter signal. In this third system it is shown that the signal in a detector set 90 degrees from the incident beam collects light reflected from the cell surface. The optical selection of cells in specific orientations using these systems may circumvent the need to physically orient cell in flow systems.

Animals↗

Two-color immunofluorescence using a fluorescence-activated cell sorter.

A technique for the analysis of fluorescein and rhodamine in a flow system using a single wavelength of excitation is described. Both optics and electronics are used to discriminate the fluorescein and rhodamine signals. This technique has been used to study the relationship between immunoglobulin M and immunoglobulin D on mouse splenic lymphocytes.

Cell Separation↗

Cell discrimination by multiangle light scattering.

Measurement of the light scattered by biological cells as a function of scattering angle provides information that can be correlated with cell type. Two flow systems that provide multiangle scattering data from cells have been constructed and tested. The first utilizes two narrow-aperture detectors positioned at different angles; the second utilizes the motion of the cell to generate complete scatter patterns of individual cells over a 67 degrees range of scattering angle.

Animals↗