Comparing multivariate and univariate subject-specific reference regions for blood constituents in healthy persons.

We examined the comparative behavior of subject-specific multivariate and univariate reference regions, using both computer-generated data and serial (semi-annual) measurements of selected analytes in subjects from a large health-maintenance program. Univariate studies under both homeostatic and random-walk time-series models were helpful in defining expected results, but only the homeostatic model was used in multivariate as well as univariate forms. Analysis of the computer-generated data and the real biochemical series produced similar findings, which showed the multivariate subject-specific reference region to be much more conservative than corresponding univariate intervals. That is, a multidimensional point of p correlated observations is quite likely to lie within the individual's multivariate reference region (based on past observation vectors), even when one or more of the observations lie outside their separate reference intervals for that individual. One consequence of this high specificity against univariate false positives in a large surveillance program is a higher than expected proportion of positive multivariate vectors in which none of the values lie outside their univariate ranges. Thus, although the development of multivariate reference regions should be encouraged, they should be used in conjunction with, not instead of, univariate ranges.

Analysis of Variance↗

Comparative evaluation of the IBM (12-lead) and Royal Infirmary (orthogonal three-lead) ECG computer programs.

A comparison of two computer programs for ECG interpretation was undertaken. Twelve-lead ECGs from 300 patients with various clinical abnormalities were interpreted at the National Institutes of Health using version 1 of the IBM program and corresponding orthogonal three-lead ECGs were analyzed by the Glasgow Royal Infirmary (GRI) program. Interpretations were compared with respect to the clinical documentation, wherever possible, and with each other directly in the case of diagnostic statements for which non-ECG documentation was not available. The two programs had a similar performance in determining abnormalities such as myocardial infarction and ventricular hypertrophy. However, with respect to conduction defects and ST-T-wave statements, certain discrepancies between the two program performances were revealed. There were 222 disagreements between various diagnostic statements. GRI was judged correct in 119 of these disagreements and IBM in 70. In these 189 cases the disagreement could most often be accounted for by different criteria and/or algorithms in the two programs or by the use of different ECG lead sets. The remaining 33 disagreements had to be classified as inconclusive.

Cardiomegaly↗

Regional ventilatory clearance by xenon scintigraphy: a critical evaluation of two estimation procedures.

Estimates of ventilatory clearance are usually made by inspecting xenon washout images. Quantitative computer procedures have been described that produce regional clearance rates, yet their accuracy is not well established. We define a mathematical model for scintigraphic ventilation data based on 96 clinical studies, and with this model we test the accuracy of two procedures used to estimate ventilatory clearance. The least-squares curve-fitting technique for both washin and washout data has the same accuracy as a modified Stewart-Hamilton method (A/H) that uses washout data alone. Both procedures demonstrate relative errors of less than 5% and coefficients of variation of 10-20% when regions with equilibrium count rates of 3 cps and clearance times between 10 and 90 sec are examined. Because the A/H procedure is preferred for its simplicity and speed, we analyze two of its main sources of error: early washin/washout termination and background activity. To measure regional ventilation by the A/H procedure, we recommend: (a) washin and washout periods at least three times the largest clearance time of clinical interest; b) a regional equilibrium count rate of at least 3cps; and c) a 25- to 50-sec average of the equilibrium count rate.

Humans↗