Optical coherence tomography: a new tool for glaucoma diagnosis.

Optical coherence tomography (OCT) is a novel technique that allows cross-sectional imaging of the anterior and posterior eye. OCT has a resolution of approximately 10 microns, with extremely high sensitivity (approximately 10(-10) of incident light). OCT is analogous to computed tomography, which uses x-rays, magnetic resonance imaging, which uses spin resonance, or B-scan ultrasound, which uses sound waves, but OCT uses only light to derive its image. OCT is a noncontact, noninvasive system by which retinal substructure may be analyzed in vivo. OCT is useful in the evaluation of retinal pathologies and glaucoma. In retinal disease, entities such as macular holes, macular edema, central serous chorioretinopathy, retinal vascular occlusion and other factors have been examined. Separation between the posterior vitreous and retina, or lack thereof, are seen and quantitated. In glaucoma, retinal nerve fiber layer (NFL) thickness is measured at standardized locations around the optic nerve head. A circular scan produces a cylindrical cross-section of the retina, from which the NFL can be analyzed. In addition, radial scans through the optic nerve head are used to evaluate cupping and juxtapapillary NFL thickness. OCT, a new imaging technology by which the anterior and posterior segment are seen in cross-section, may permit the early diagnosis of glaucoma, and the early detection of glaucomatous progression.

Anterior Eye Segment↗

Micrometer-scale resolution imaging of the anterior eye in vivo with optical coherence tomography.

OBJECTIVE: To demonstrate a new diagnostic technique, optical coherence tomography, for high-resolution cross-sectional imaging of structures in the anterior segment of the human eye in vivo. Optical coherence tomography is a new, noninvasive, noncontact optical imaging modality that has spatial resolution superior to that of conventional clinical ultrasonography (< 20 microns) and high sensitivity (dynamic range, > 90 dB). DESIGN: Survey of intraocular structure and dimension measurements. SETTING: Laboratory. PATIENTS: Convenience sample. MAIN OUTCOME MEASURES: Correlation with range of accepted normal intraocular structure profiles and dimensions. RESULTS: Direct in vivo measurements with micrometer-scale resolution were performed of corneal thickness and surface profile (including visualization of the corneal epithelium), anterior chamber depth and angle, and iris thickness and surface profile. Dense nuclear cataracts were successfully imaged through their full thickness in a cold cataract model in calf eyes in vitro. CONCLUSIONS: Optical coherence tomography has potential as a diagnostic tool for applications in noncontact biometry, anterior chamber angle assessment, identification and monitoring of intraocular masses and tumors, and elucidation of abnormalities of the cornea, iris, and crystalline lens.

Anterior Chamber↗

Optical coherence tomography.

A technique called optical coherence tomography (OCT) has been developed for noninvasive cross-sectional imaging in biological systems. OCT uses low-coherence interferometry to produce a two-dimensional image of optical scattering from internal tissue microstructures in a way that is analogous to ultrasonic pulse-echo imaging. OCT has longitudinal and lateral spatial resolutions of a few micrometers and can detect reflected signals as small as approximately 10(-10) of the incident optical power. Tomographic imaging is demonstrated in vitro in the peripapillary area of the retina and in the coronary artery, two clinically relevant examples that are representative of transparent and turbid media, respectively.

Coronary Disease↗