Spectral analysis of heart rate variability in the sepsis syndrome.

Sympathetic and parasympathetic activity was evaluated on 39 occasions in 17 patients with the sepsis syndrome, by measurement of the variation in resting heart rate using frequency spectrum analysis. Heart rate was recorded by electrocardiography and respiratory rate by impedance plethysmography. The sepsis syndrome was established on the basis of established clinical and physiological criteria. Subjects were studied, whenever possible, during the period of sepsis and during recovery. Spectral density of the beat-to-beat heart rate was measured within the low frequency band 0.04 to 0.10 Hz (low frequency power, LFP) modulated by sympathetic and parasympathetic activity, and within a 0.12 Hz band width at the respiratory frequency mode (respiratory frequency power, RFP) modulated by parasympathetic activity. Results were expressed as the total variability (total area beneath the power spectrum), as the spectral components normalized to the total power (LFPn, RFPn) or as the ratio of LFP/RFP. During the sepsis syndrome, total heart rate variability and the sympathetically mediated component, LFPn were significantly lower than during the following recovery phase (ANOVA, p < 0.0001, p < 0.01 respectively). Both APACHE II (Acute Physiological and Chronic Health Evaluation) and TISS (Therapeutic Intervention Scoring System) scores showed an inverse correlation with total heart rate variability, logLFP, LFPn and the LFP/RFP ratio (p < 0.002 to 0.0001). Sympathetically mediated heart rate variability was significantly lower during the sepsis syndrome and was inversely proportional to disease severity.

Adult↗

Persistent peripheral vasodilation and sympathetic activity in hypotension after maximal exercise.

Hemodynamics (by aortic Doppler), autonomic factors (power spectrum analysis of heart rate and blood pressure variabilities and baroreceptor sensitivity), and plasma renin activity during the hypotension after maximal exercise were studied in 10 normal subjects on two separate days: a nonexercise (control) day (30 min of upright rest followed by 60 min of supine rest) and an exercise day (maximal upright bicycle exercise followed by 60 min supine) in random order. After exercise, diastolic pressure was reduced for the entire hour, cardiac output increased (+33.8%, P < 0.05), stroke volume was unchanged, and systemic vascular resistance fell (-28.6%, P < 0.01). Indexes of vagal activity were reduced for 60 min, whereas the sympathetic indexes were elevated. Baroreflex sensitivity was also reduced for the first 10 min after exercise. Renin activity increased threefold after exercise. The postexercise hypotension results from a persisting peripheral vasodilation despite an increase in renin activity: the persistent sympathetic activity and reduced vagal tone are probably reflex responses to this vasodilatation.

Adult↗

[Hypotension following maximum physical exercise. Evaluation of hemodynamic and humoral mechanisms].

The period after exercise has received little attention although there are rapid and arge changes in the loading conditions of the heart and circulation which may precipitate hypotension or arrhythmias. Little is known of the time course of the recovery of cardiac output and humoral changes occurring during this periods. After a single bout of prolonged muscular exercise, systolic and diastolic blood pressure decrease, sometimes for several hours. In a recent controlled study for the possible effects of the expecting of the exercise, a reduction in diastolic blood pressure was observed particularly in the first 10 min and lasting to 60 min. The mechanisms of the acute hypotensive effect of upright dynamic exercise have not yet been clarified. Little is known of the time course of the recovery of cardiac output, humoral and autonomic changes occurring during this period. Conflicting data are presented by different authors. The aim of the present study was to study the role of the haemodynamic and humoral changes in the modifications in blood pressure occurring in the hour of recovery after maximal exercise in normal subjects. Nine normal male volunteers (age: 28:34 years) have been studied on 2 separate days. Subjects were studied on a non-exercise (control) day (the subjects maintained the upright position for 30 min, followed by 60 min supine) and an exercise day (maximal upright bicycle exercise followed by supine rest for 60 min), in a random order. The following data have been recorded before the test and serially during 60 minute supine: systolic and diastolic blood pressure, heart rate, haemodynamic changes (by suprasternal aortic Doppler), and humoral changes (renin).(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Comparison of different methods for assessing sympathovagal balance in chronic congestive heart failure secondary to coronary artery disease.

Twenty-five patients (aged 62 +/- 2 years) with stable, moderate to severe ischemic congestive heart failure (CHF) (New York Heart Association class II/III: 15/10; ejection fraction 21.6 +/- 2%; and peak oxygen uptake 13.6 +/- 0.7 ml/kg/min) were studied to evaluate the ability of different methods to characterize autonomic tone in chronic CHF. Sympathovagal balance was assessed by: (1) heart rate variability in the time domain, assessed by the SD of RR intervals; (2) heart rate variability in the frequency domain, assessed by low- (0.03 to 0.14 Hz) and high- (0.18 to 0.40 Hz) frequency components of heart rate variability by autoregressive power spectral analysis; (3) 24-hour, daytime and nighttime heart rate; (4) submaximal heart rate during upright bicycle exercise, with respiratory gas analysis to obtain peak oxygen uptake; and (5) radiolabeled norepinephrine spillover. These methods did not correlate, with the exception of day and nighttime heart rate (r = 0.74; p < 0.001) and the expected inverse correlation between low and high frequency (r = -0.92; p < 0.001). No method correlated significantly with peak oxygen uptake, exercise tolerance or ejection fraction. After 8 weeks of physical training at home, all methods showed improvement in autonomic balance: increases in SD of RR intervals (+21%; p < 0.02) and high frequency (+41%; p < 0.007), and decreases in low frequency (-19%; p < 0.002), low-/high-frequency ratio (-48%; p < 0.03), norepinephrine spillover (-28.9%; p < 0.03), 24-hour heart rate (-2.7%; p < 0.005) and submaximal heart rate (-10.8%; p < 0.01).(ABSTRACT TRUNCATED AT 250 WORDS)

Autonomic Nervous System Diseases↗

Effects of mild physical activity, atenolol and the combination on ambulatory blood pressure in hypertensive subjects.

OBJECTIVE: To evaluate whether beta-blocker treatment could enhance the effect of a mild physical training programme upon blood pressure. DESIGN AND METHODS: In 12 hypertensive subjects (mean age: 40.3 years) a prospective randomized Latin square-design trial was performed with three treatments: physical training and placebo tablets; atenolol 50 mg once a day and inactivity; and physical training and atenolol 50 mg once a day. RESULTS: Training significantly increased maximal ventilatory oxygen consumption (VO2MAX), and there was a decrease in ambulatory diastolic blood pressure (DBP) which did not reach statistical significance. Atenolol alone significantly reduced ambulatory systolic blood pressure (SBP) and DBP. Atenolol alone did not reduce VO2MAX. The combination of training and atenolol resulted in an increase in VO2MAX compared with atenolol alone, but no additional significant fall in blood pressure. CONCLUSIONS: Atenolol did not enhance the effect of physical training upon blood pressure and had little if any effect upon the training-induced increase in exercise tolerance.

Adult↗

Time course of pressure and flow in ascending aorta during ejection.

To analyze aortic flow and pressure relationships, 10 closed-chest anaesthetised dogs were instrumented with electromagnetic aortic flow probes and micromanometers in the left ventricle and ascending aorta. Left ventricular ejection time was divided into: time to peak flow (T1) (both pressure and flow rising), peak flow to peak pressure time (T2) (pressure rising, flow decreasing), and peak pressure to dicrotic notch time (T3) (pressure and flow both decreasing). These time intervals were expressed as percent of total ejection time. Load-active interventions rose markedly T2 (from 4.2 +/- 5.5 to 19.4 +/- 3.5 after phenylephrine (p less than 0.02); from 4.2 +/- 6.5 to 21.2 +/- 5.3 after dextran (p less than 0.02)). Conversely, dobutamine reduced T2 from 4.4 +/- 5.9 to -2.5 +/- 6.5 (p less than 0.05). Thus, during load-active interventions aortic pressure increases for a longer T2 time although forward flow is decreasing, as a result of higher aortic elastic recoil during ejection. Conversely, beta 1-adrenergic stimulation significantly shortens T2. Dynamic pressure-flow relationship is thus continuously changing during ejection. T2 seems to be inversely related to the efficiency of left ventricular ejection dynamics.

Animals↗

Measuring left ventricular dimensions by conductance catheter in the rabbit.

A miniaturized (3.5 F), six-electrode conductance catheter was tested in 18 anaesthetized adult rabbits (weight 3.8-4.6 kg, ethylurethane 2.5 g kg-1). In eight animals, the reference stroke volume (ref-SV) was obtained by an electromagnetic flow probe, while reference end-diastolic volume (ref-LVEDV) was computed by dividing ref-SV by undamped thermal dilution ejection fraction (ref-EF) estimates. Comparisons with conductance indexes (z-SV, z-LVEDV and z-EF) were made at baseline, subsequent levels of graded haemorrhage and reinfusion state. In 10 animals intraventricular segmental conductance was compared with echocardiographic left ventricular cross-section (5 MHz short-focus probe), in the basal state and during acute left ventricular volume changes generated by inferior vena cava balloon occlusion. In each experiment, parallel conductance due to the tissues surrounding the left ventricle (Gp) was determined by infusing a 5M NaCl solution bolus into the right ventricle. Linear regression analysis showed fairly good correlations between z-SV, z-LVEDV and z-EF and reference indexes (r = 0.84, r = 0.83, and r = 0.72, respectively; P less than 0.001 in all cases). A linear regression analysis from 17 interventions (inferior vena cava balloon occlusion) showed a good correlation between left ventricular echocardiographic cross-sectional area and conductance, and higher correlation coefficients, r ranging from 0.870 to 0.986 were obtained from continuously sampled conductance and echographic measurements. Parallel conductance Gp was correlated (r = 0.807, P less than 0.01) with the intercept of the regression line of echographic vs conductance data. The determination of Gp thus improved the accuracy of the left ventricular dimension estimate. These results add further evidence for the possibility of continuous monitoring of left ventricular dimension by means of a conductance catheter, and demonstrate the feasibility of such studies on small experimental animals.

Animals↗

[The efficacy of oral treatment with flecainide for paroxysmal atrial fibrillation: correlation with plasma concentration].

In the acute treatment of paroxysmal atrial fibrillation several drugs can be used. The aim of our work was to assess the efficacy of a single oral dose of flecainide in the conversion to sinus rhythm by correlating this data with flecainide plasma concentration. We have considered 37 patients affected by paroxysmal atrial fibrillation (for more than 8 hours) randomly assigned to the following two groups: group A, 19 patients, mean age 44.4 +/- 1.9 years) treated with flecainide (200 mg) and control group B (18 patients, mean age 46.6 +/- 1.8 years). This was done in order to point out any possible overlap between pharmacological and spontaneous conversion to sinus rhythm. In all patients, the following were performed: a Holter recording (524 hours) to evaluate the time of conversion to sinus rhythm (t-conversion to sinus rhythm), a determination of flecainide plasma concentration (after 150 flecainide administration) an Rx, an Echo-2D/Doppler test and an estimation of thyroid function. The Rx, the Echo-2D/Doppler and the endocrinological data in the 2 groups did not show any significant differences. We obtained a conversion to sinus rhythm in all but one of the group A patients (time of conversion to sinus rhythm 162 +/- 83 min) and in just 5 group B patients (time of conversion to sinus rhythm 1118 +/- 125 min) (time of conversion to sinus rhythm A vs B p less than .001).(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Treatment of chronic heart failure: an expert system advisor for general practitioners.

Most decision-support systems in medicine have been developed in hospital environments, but only few are designed for being used by general practitioners. The present work aims to design an expert system for practitioners in chronic heart failure (CHF) treatment. It provides assistance in defining the therapy relying on CHF aetiology, gravity, physiopathological conditions, and discriminates if other coexistent diseases and/or drugs taken by the patient could interact with CHF management. It warns the physician about the possible interactions of the considered CHF therapy. In case of contraindications, the system suggests another alternative therapy. It also advices about the control tests to follow-up the prescribed therapy, and about the indicated hygienic-dietetic suggestions. To assess its internal consistency, we examined the behaviour of the system with 20 CHF patients, by comparing the suggested therapy with the prescriptions of cardiologists. In 9 cases the suggested therapeutic schemes contained all the "n" drugs administered by the cardiologists. In 5 cases the concordance was on at least two thirds of the prescribed medications, in 5 between one half and two thirds, while in 1 case there was no concordance at all. In none of the 10 cases with partial concordance, were there major discrepancies (i.e. potentially deleterious for the patient) between the expert system's suggestions and the cardiologists' prescriptions. In conclusion, the advices of the expert system were similar to those of the cardiologists, suggesting the feasibility of such a computer support to CHF management.

Anti-Arrhythmia Agents↗

Pulsatility and resistance indices in intrarenal arteries of normal adults.

In order to establish the normal range of values of Pulsatility (PI) and Resistance (RI) Indices in the intrarenal vasculature, a study of 50 healthy volunteers (23 males, 27 females), divided into five groups of 10 according to age, was performed with Duplex Doppler ultrasound. Both kidneys were examined in all individuals and, in 12, indices were also compared between upper and lower poles of both kidneys. In addition, repeat examinations were performed in nine subjects on three different days, in order to assess the reproducibility of the method. No differences were found in the mean values of both indices between males and females, upper and lower poles, right and left kidneys. A statistically significant increase (p < 0.01, unpaired t-test) was demonstrated when the oldest age group (7th decade) was compared to the youngest age group (3rd decade). The method appeared remarkably reproducible for RI (4.2-7%), with wider variation in the PI (9.5-22.7%).

Adult↗

Microcomputer-aided diagnosis in cardiology. An expert system based on clinical and phono-mechanocardiographic data.

A knowledge-based consultation system capable of making multiple diagnoses in noninvasive cardiology is presented here. The system, expressly designed for a personal computer, is able to provide assistance in the diagnosis of 49 disease-entities. When tested in 52 retrospective cases (33 patients with one disease-entity, 17 with two, 2 with three), it made 39 correct diagnoses (75%). The average score of the actually present disease-entities was 94 +/- 3.2 (mean +/- standard error of the mean), significantly higher than the highest score obtained by the incorrect diagnoses (87.2 +/- 3.1) (p less than 0.001). The system was able to correctly perform 1 triple diagnosis and 9 double diagnoses. The results obtained, comparable with those of well-known expert systems (MYCIN, INTERNIST-1), demonstrate the reliability of a microcomputer-based expert system for medical diagnosis in cardiology.

Diagnosis, Computer-Assisted↗