Improving calibration accuracy in gel dosimetry.

A new method of calibrating gel dosimeters (applicable to both Fricke and polyacrylamide gels) is presented which has intrinsically higher accuracy than current methods, and requires less gel. Two test-tubes of gel (inner diameter 2.5 cm, length 20 cm) are irradiated separately with a 10 x 10 cm2 field end-on in a water bath, such that the characteristic depth-dose curve is recorded in the gel. The calibration is then determined by fitting the depth-dose measured in water, against the measured change in relaxivity with depth in the gel. Increased accuracy is achieved in this simple depth-dose geometry by averaging the relaxivity at each depth. A large number of calibration data points, each with relatively high accuracy, are obtained. Calibration data over the full range of dose (1.6-10 Gy) is obtained by irradiating one test-tube to 10 Gy at dose maximum (Dmax), and the other to 4.5 Gy at Dmax. The new calibration method is compared with a 'standard method' where five identical test-tubes of gel were irradiated to different known doses between 2 and 10 Gy. The percentage uncertainties in the slope and intercept of the calibration fit are found to be lower with the new method by a factor of about 4 and 10 respectively, when compared with the standard method and with published values. The gel was found to respond linearly within the error bars up to doses of 7 Gy, with a slope of 0.233 +/- 0.001 s(-1) Gy(-1) and an intercept of 1.106 +/- 0.005 Gy. For higher doses, nonlinear behaviour was observed.

Acrylamides↗

An investigation into the dosimetry of a nine-field tomotherapy irradiation using BANG-gel dosimetry.

BANG-gel dosimetry offers the potential for measuring the dose delivered by a radiotherapy treatment technique, in three dimensions, with high spatial resolution and good accuracy. The ability to measure comprehensively a 3D dose distribution is a major advantage of the gel dosimeter over conventional planar and point-based dosimeter devices, particularly when applied to the verification of complex dose distributions characteristic of intensity-modulated radiotherapy (IMRT). In this paper an in-house manufactured BANG-gel dosimeter was applied to study the dose distributions of two irradiation experiments for which the distributions were known: (i) a dosimetrically simple parallel-opposed irradiation, and (ii) a more complex nine-field 'static tomotherapy' intensity-modulated irradiation delivered with the Nomos MIMiC. The uniform distribution in (i) allowed a study of the magnetic resonance (MR) imaging parameters to achieve an optimal trade-off between noise and image resolution (optimum image resolution for the Siemens 1.5T Vision system was determined to be approximately 0.8 mm2 with a slice thickness of 2 mm). The spatial uniformity of gel sensitivity to radiation was found to depend strongly on the presence of oxygen, which must be eliminated for the gel dosimeter to be of use. The gel dosimeter was found to agree well with predicted dose distributions and accurately measured the steep penumbral fall-off of dose, even after many days, proving its potential for the verification of IMRT distributions. In the nine-field IMRT delivery (ii) the predicted dose was computed by both an in-house 'component-delivery' dose algorithm and the Peacock planning-system dose algorithm. Good agreement was found between the two algorithms despite the latter's omission of the change in penumbral characteristics with aperture-size during delivery, lack of inhomogeneity correction and approximate modelling of leaf leakage. These effects were found to be small for the problem studied. The predicted distribution agreed well with the gel-measured distribution at medium and high doses (50-90% isodose lines) although differences of up to 10% were observed at lower doses (30% isodose line). The gel dosimeter was found to have the potential to verify IMRT distributions but required considerable care to achieve accurate results. Attention was required to achieve uniformity of gel sensitivity (to prevent oxygen contamination), and in the calibration process.

Acrylamide↗

A case study comparing the relative benefit of optimizing beam weights, wedge angles, beam orientations and tomotherapy in stereotactic radiotherapy of the brain.

A treatment-planning case study has been performed on a patient with a medium-sized, convex brain tumour. The study involved the application of advanced treatment-plan optimization techniques to improve on the dose distribution of the 'standard plan' used to treat the patient. The standard plan was created according to conventional protocol at the Royal Marsden NHS Trust, and consisted of a three-field (one open and two wedged) non-coplanar arrangement, with field shaping to the beam's-eye view of the planning target volume (PTV). Three optimized treatment plans were created corresponding to (i) the optimization of the beam weights and wedge angles of the standard plan, (ii) the optimization of the beam orientations, beam weights and wedge angles of the standard plan, and (iii) a full fluence tomotherapy optimization of 1 cm wide (at isocentre), 270 degree arcs. (i) and (ii) were created on the VOXELPLAN research 3D treatment-planning system, using in-house developed optimization algorithms, and (iii) was created on the PEACOCK tomotherapy planning system. The downhill-simplex optimization algorithm is used, in conjunction with 'threshold-dose' cost-function terms enabling the algorithm to optimize specific regions of the dose-volume histogram (DVH) curve. The 'beam-cost plot' tool is presented as a visual aid to the selection of beneficial beam directions. The methods and pitfalls in the transfer of plans and patient data between the two planning systems are discussed. Each optimization approach was evaluated, relative to the standard plan, on the basis of DVH and dose statistics in the PTV and organs at risk (OARs). All three optimization approaches were able to improve on the dose distribution of the standard plan. The magnitude of the improvement was greater for the optimized beam-orientation and tomotherapy plans (up to 15% and 30% for the maximum and mean OAR doses). A smaller improvement was observed in the beam-weight and wedge-angle optimized plan (up to 5% and 10% in the maximum and mean OAR doses). In the tomotherapy plan, difficulty was encountered achieving an acceptable homogeneity of dose in the PTV. This was improved by treating the gross tumour volume (GTV) and (PTV - GTV) regions as separate targets in the inverse planning, with the latter region prescribed a slightly higher dose to reduce edge under-dosing. In conclusion, for the medium-sized convex tumour studied, the tomotherapy dose distribution showed a significant improvement on the standard plan, but no significant improvement over a conventional three-field plan where the beam orientations, beam weights and wedge angles had been optimized.

Adenoma↗

Improvements in prostate radiotherapy from the customization of beam directions.

A methodology for optimizing the beam directions in radiotherapy treatment planning has been developed and tested on a cohort of twelve prostate patients. An optimization algorithm employing a an objective cost function was used, based on beam's-eye-view volumetrics but also employing a simple dose model and biological considerations for organs-at-risk (OARs). The cost function embodies information about the volume of OARs in a single field and their position relative to the planning target volume (PTV). The proximity of the PTV to the surface of the patient is also included. Within the algorithm "importance factor" were used to model the clinical importance of different organs-at-risk so that all organs-at-risk were included in a single objective score. "Gantry-angle-windows" were introduced to restrict the available beam directions. The methodology was applied to twelve prostate patients to determine the optimum beam directions for three-field direction plans. Orientation-optimized and standard treatment plans were compared via measures of tumor control probability (TCP) and normal tissue complication probability (NTCP). Standard plans had fixed beam directions whereas orientation-optimized plans contained beam directions chosen by the algorithm. The beam-weights of both the orientation-optimized and standard plans were optimized using a dose-based simulated annealing algorithm to allow the improvements by optimizing the beam directions to be studied in isolation. The results of the comparison show that optimization of the beam directions yielded better plans, in terms of TCP and NTCP, than the standard plans. When the dose to the isocenter was scaled to produce a rectal NTCP of 1%, the average TCP of the orientation-optimized plans was (5.7 +/- 1.4)% greater than that for the standard plans. In conclusion, the customization of beam directions in the treatment planning of prostate patients using and objective cost function and allowed gantry-angle-windows produces superior three-field direction plans compared to standard treatment plans.

Algorithms↗

A comparison of conventional and conformal radiotherapy of the oesophagus: work in progress.

A retrospective treatment planning study was carried out in five patients to assess the effectiveness of conformal radiotherapy of the oesophagus. A two-phase conventional treatment plan was created for each patient, with a prescribed dose of 55 Gy. This plan was compared with a single-phase conformal plan consisting of the same field arrangement as the second phase of the conventional treatment, but with conformal blocks shaped to the beam's eye view of the planning target volume. A further comparison was made between the conventional plan and a two-phase plan using the same beam angles and weights as the conventional plan, but with conformal field shapes. The effectiveness of each treatment plan was assessed using dose--volume histograms and normal tissue complication probabilities for the lungs. On average, the single-phase conformal technique increased the mean lung dose from 22.5% (+/- 6.2 SD) of the prescribed dose to 29.5% (+/- 5.2 SD) compared with the conventional technique (p = 0.0001). This indicates that this technique did not offer any benefit in terms of reducing the risk of pneumonitis. However, the two-phase conformal technique reduced the mean lung dose from 22.5% (+/- 6.2 SD) of the prescribed dose to 19.8% (+/- 4.6 SD)(p = 0.03), showing that this technique should reduce the risk of pneumonitis. Further work is underway to study more patients and to investigate tumour control probability and dose escalation.

Antimetabolites, Antineoplastic↗

Intensity-modulated radiotherapy by means of static tomotherapy: a planning and verification study.

There is currently much research interest in developing, evaluating, and verifying intensity-modulation techniques. Of particular interest is how well the delivery of intensity-modulated profiles can be simulated by planning algorithms, and how accurately these profiles can be delivered given the specification constraints of linear accelerators. In this paper we present a planning and verification study based on delivering radiation in "static-tomotherapy" mode via the NOMOS MIMiC (Multileaf intensity-modulation collimator), which sheds some light on these issues. An inverse-planning algorithm was used to compute intensity-modulated profiles for a 9-coplanar-field plan for a body phantom. The algorithm makes several approximations about the form of the elementary fluence profile through bixels during delivery. Specifically, it is independent of the state of adjacent bixels (i.e., open or closed) and obeys the superposition principle. From the standpoint of comparing the predicted versus the delivered dose, these assumptions were made irrelevant by a final one-step forward dose calculation performed using the optimized intensity profiles. This forward dose calculation took into account the penumbral characteristics of the delivery system by decomposing the intensity profiles into the set of delivery components. Each component was assigned the appropriate penumbral functions thereby ensuring that the calculated dose distribution closely predicted the delivered dose distribution. The nine intensity modulated fields were delivered to a perspex phantom with the same geometry, containing a verification film. In general good agreement was found between the predicted and the measured delivered dose distributions. All the main features of the predicted dose distribution are seen in the delivered. The 90% isodoses were consistently in spatial agreement to within 3 mm. At the 50% isodose level consistent spatial agreement was again found to within 3 mm, the largest deviation being about 5 mm. The close correspondence between the predicted and measured dose distribution demonstrates the potential of the MIMiC delivery system. Our results indicate the level of dose conformation that is achievable in practice and the accuracy of the dose computation algorithm. However, this study only concerned delivery of radiation to a 2 cm thick slice, and the dose distribution was only verified in the central plane of the phantom where the film was placed. We therefore cannot comment as yet on what happens to the dose distribution away from the central film-plane.

Algorithms↗

Methods for transferring patient and plan data between radiotherapy treatment planning systems.

The effectiveness of conformal radiotherapy can ultimately only be assessed by the use of clinical trials. As large multicentre clinical trials become more widespread, methods of transferring patient and plan data between radiotherapy treatment planning systems become increasingly important. In this paper, the general strategy for the transfer of data is discussed, and also illustrated with reference to two specific systems: TARGET 2 (GE Medical Systems) and VOXELPLAN (DKFZ-Heidelberg). The transfer method involves using a computer program to translate the data formats used by each of the two systems for CT scans, patient outlines, plan information and block descriptions. This paper does not address the question of transferring beam data between systems: beam data must first be entered separately into both machines. The physical concepts encountered when transferring plans are described, with specific reference to the two planning systems used. Differences in the strategies used by the two planning systems for definition of irregular field shapes are compared. The dose calculations used by the two systems are also briefly evaluated. Isodoses produced by VOXELPLAN around a circular target volume are found to be up to 3 mm different in location to those produced by TARGET 2, owing to the use of a smooth field shape contour as opposed to a stepped field shape which closely models the leaves of a multileaf collimator. In general, dose distributions generated by both systems are comparable, but some differences are found in the presence of large tissue inhomogeneities. It is concluded that the transfer of patient and plan data between two different treatment planning systems is feasible, provided that any differences in field shape definition methods or dose calculation methods between the two systems are understood.

Humans↗

A method to study the characteristics of 3D dose distributions created by superposition of many intensity-modulated beams delivered via a slit aperture with multiple absorbing vanes.

Highly conformal dose distributions can be created by the superposition of many radiation fields from different directions, each with its intensity spatially modulated by the method known as tomotherapy. At the planning stage, the intensity of radiation of each beam element (or bixel) is determined by working out the effect of superposing the radiation through all bixels with the elemental dose distribution specified as that from a single bixel with all its neighbours closed (the 'independent-vane' (IV) model). However, at treatment-delivery stage, neighbouring bixels may not be closed. Instead the slit beam is delivered with parts of the beam closed for different periods of time to create the intensity modulation. As a result, the 3D dose distribution actually delivered will differ from that determined at the planning stage if the elemental beams do not obey the superposition principle. The purpose of this paper is to present a method to investigate and quantify the relation between planned and delivered 3D dose distributions. Two modes of inverse planning have been performed: (i) with a fit to the measured elemental dose distribution and (ii) with a 'stretched fit' obeying the superposition principle as in the PEACOCK 3D planning system. The actual delivery has been modelled as a series of component deliveries (CDs). The algorithm for determining the component intensities and the appropriate collimation conditions is specified. The elemental beam from the NOMOS MIMiC collimator is too narrow to obey the superposition principle although it can be 'stretched' and fitted to a superposition function. Hence there are differences between the IV plans made using modes (i) and (ii) and the raw and the stretched elemental beam, and also differences with CD delivery. This study shows that the differences between IV and CD dose distributions are smaller for mode (ii) inverse planning than for mode (i), somewhat justifying the way planning is done within PEACOCK. Using a stretched elemental beam is a useful adjustment to improve the accuracy of inverse planning but the 3D dose distribution actually delivered will display characteristics of the collimation.

Humans↗

A comparison of conventional 'forward planning' with inverse planning for 3D conformal radiotherapy of the prostate.

A radiotherapy treatment plan optimisation algorithm has been applied to 48 prostate plans and the results compared with those of an experienced human planner. Twelve patients were used in the study, and 3-, 4-, 6- and 8-field plans (with standard coplanar beam angles for each plan type) were optimised by both the human planner and the optimisation algorithm. The human planner 'optimised' the plan by conventional forward planning techniques. The optimisation algorithm was based on fast simulated annealing using a cost-function designed to achieve a homogenous dose in the 'planning-target-volume' and to minimise the integral dose to the organs at risk. 'Importance factors' assigned to different regions of the patient provide a method for controlling the algorithm, and it was found that the same values gave good results for almost all plans. A study of the convergence of the algorithm is presented and optimal convergence parameters are determined. The plans were compared on the basis of both dose statistics and 'normal-tissue-complication-probability' (NTCP) and 'tumour-control-probability' (TCP). The results of the comparison study show that the optimisation algorithm yielded results that were at least as good as the human planner for all plan types, and on the whole slightly better. A study of the beam-weights chosen by the optimisation algorithm and the planner revealed differences that increased with the number of beams in the plan. The planner was found to make small perturbations about a conceived optimal beam-weight set. The optimisation algorithm showed much greater showed much greater variation, in response to individual patient geometry, frequently deselecting certain beams altogether from the plan. The algorithm is shown to be a useful tool for radiotherapy treatment planning. For simple (e.g., three-field) plans it was found to consistently achieve slightly higher TCP and lower NTCP values. For more complicated (e.g., eight-field) plans the optimisation also achieved slightly better results with generally less numbers of beams, unfavourable beams being deselected from the plan. Probably the greatest benefit is the reduced time taken by the optimisation to compute optimised beam-weights. This time always < or = 5 min; a factor of up to 20-times faster than the human planner.

Algorithms↗

Comparison of treatment techniques for conformal radiotherapy of the prostate using dose-volume histograms and normal tissue complication probabilities.

The aim of this study was to evaluate the relative merits of the coplanar field arrangements most frequently used for conformal radiotherapy of the prostate using dose-volume histograms and normal tissue complication probabilities (NTCPs). Twelve patients with early prostate cancer underwent a planning CT scan of the pelvis. Isocentric plans for each patient were devised using three, four, six and eight conformal fields and beam-weights optimised using fast simulated annealing to give a dose homogeneity across the planning target volume of +/- 5% or better while minimising irradiation of the relevant organs at risk. The plans were then evaluated using dose-volume histograms of the organs at risk (bladder, rectum and both femoral heads) and the Lyman model of normal tissue complication probability for the rectum. Analysis of dose-volume histogram data averaged over the 12 patients indicates an advantage for six (p = 0.002) and eight (p = 0.0001) fields with respect to the percentage volume of the femoral heads receiving > 50% of the prescribed dose compared with three fields. There was a similar advantage for six (p = 0.0007) and eight (p = 0.0001) fields compared with four fields. Ranking of the treatment techniques indicates that the four-field technique is the worst with respect to femoral head irradiation but the best with respect to reducing rectal irradiation. A higher dose can be prescribed to the isocentre with the four-field technique for a 5% rectal NTCP. The six-field technique led to sparing of the bladder when the different treatment techniques were ranked using bladder dose-volume histogram data. We conclude that none of the techniques studied consistently proved to be superior when applied to this sample of patients with prostate cancer with respect to sparing all the organs at risk. The absolute differences between techniques are small and would be very difficult to detect with respect to clinically relevant endpoints.

Algorithms↗

The optimisation of wedge filters in radiotherapy of the prostate.

A treatment plan optimisation algorithm has been applied to 12 patients with early prostate cancer in order to determine the optimum beam-weights and wedge angles for a standard conformal three-field treatment technique. The optimisation algorithm was based on fast-stimulated-annealing using a cost function designed to achieve a uniform dose in the planning-target-volume (PTV) and to minimise the integral doses to the organs-at-risk. The algorithm has been applied to standard conformal three-field plans created by an experienced human planner, and run in three PLAN MODES: (1) where the wedge angles were fixed by the human planner and only the beam-weights were optimised; (2) where both the wedge angles and beam-weights were optimised; and (3) where both the wedge angles and beam-weights were optimised and a non-uniform dose was prescribed to the PTV. In the latter PLAN MODE, a uniform 100% dose was prescribed to all of the PTV except for that region that overlaps with the rectum where a lower (e.g., 90%) dose was prescribed. The resulting optimised plans have been compared with those of the human planner who found beam-weights by conventional forward planning techniques. Plans were compared on the basis of dose statistics, normal-tissue-complication-probability (NTCP) and tumour-control-probability (TCP). The results of the comparison showed that all three PLAN MODES produced plans with slightly higher TCP for the same rectal NTCP, than the human planner. The best results were observed for PLAN MODE 3, where an average increase in TCP of 0.73% (+/- 0.20, 95% confidence interval) was predicted by the biological models. This increase arises from a beneficial dose gradient which is produced across the tumour. Although the TCP gain is small it comes with no increase in treatment complexity, and could translate into increased cures given the large numbers of patients being referred. A study of the beam-weights and wedge angles chosen by the optimisation algorithm revealed significant inter-patient variability the implications of which are examined. Probably the most significant benefit of the algorithm is the time saved (about a factor of 10) in computing optimised beam-weights and wedge angles for this simple plan.

Algorithms↗

The optimization and inherent limitations of 3D conformal radiotherapy treatment plans of the prostate.

This paper describes the applications of an inverse planning optimization algorithm to the real clinical problem of prostate cancer. The algorithm has been designed to compute optimized beam-weights taking full account of three-dimensional spatial information of dose inside the patient. The algorithm is based on fast simulated annealing, utilizing a cost-function containing both linear and quadratic terms. The linear part of the cost function allows for the implementation of "short-cuts" in the cost-function computation, which reduces the calculation time by a factor of about 30. It has been applied to compute optimized beam-weights for a three-field and a seven-field prostate treatment plan. It is shown for the three-field plan that the optimization algorithm can reproduce, and even slightly improve on, the results of an experienced human planner. For the seven-field plan, the human planner experienced difficulty finding beam-weights that gave an acceptable dose distribution. It is shown that the optimization algorithm can achieve good results in this case. The outcome of the optimization of the seven-field plan prompted an investigation into the best results that could be achieved by an "ideal" conformal radiotherapy technique. The results of this investigation are presented and it is shown that the limiting factor for conformal therapy of the prostate is the size of the overlap volume between the planning target volume (PTV) and the rectum. Finally, the efficiency and accuracy of fast simulated annealing is compared with that of classical simulated annealing. The former was found to be at least 10 times faster for the problem studied.

Algorithms↗