Search PubMed⌕ Search

Biomedical subjects

M O Columb

Publications and source records attributed to M O Columb.

At least 19 recordsLinked to original sources

Minimum dose of intrathecal diamorphine required to prevent intraoperative supplementation of spinal anaesthesia for Caesarean section.

BACKGROUND: Intraoperative discomfort during spinal anaesthesia for Caesarean section is the commonest cited anaesthetic cause of litigation in obstetric practice. Intrathecal opioids are used to improve intraoperative comfort and postoperative analgesia for these operations. The minimum intrathecal diamorphine dose that prevents intraoperative supplementation requires determination. METHOD: After ethics committee approval, 200 ASA I, II women with > or = 37 weeks gestation and planned for elective Caesarean section under combined spinal-epidural anaesthesia were recruited. They were randomized into four groups to receive hyperbaric bupivacaine 0.5% 12.5 mg with diamorphine 0.2, 0.3, 0.4 or 0.5 mg by intrathecal injection. The need for intraoperative i.v. supplementation with alfentanil, time to first requests for postoperative analgesia, incidence of nausea and vomiting and requirement for antiemetic and antipruritic were noted. RESULTS: Intraoperative supplementation was inversely proportional to the dose of diamorphine used (P=0.004). The ED(95) value for intrathecal diamorphine to prevent intraoperative supplementation was 0.39 mg. Mean time interval for request for postoperative analgesia was 446 min in the 0.2 mg group, 489 min in the 0.3 mg group, 601 min in the 0.4 mg group and 687 min in the 0.5 mg group (P=0.003 for trend). Incidence of nausea, vomiting and pruritus increased with dose of diamorphine used (P values for trend: nausea, 0.04; vomiting, 0.008; pruritus, 0.004). Requests for antiemetic increased with dose but achieved significance only for requirement for second antiemetic (P=0.03). Request for antipruritic did not achieve significance. CONCLUSION: The ED(95) for the amount of intrathecal diamorphine required to prevent intraoperative supplementation during spinal anaesthesia for Caesarean section is 0.4 mg in clinical terms. Times to first requests for analgesia, incidence of nausea, vomiting and pruritus increase with dose.

Adult↗

Effect of changes in arterial-mixed venous oxygen content difference (C(a-v)O2) on indices of pulmonary oxygen transfer in a model ARDS lung.

Many indices are used to quantify pulmonary oxygen transfer. Indices that use only measurements from arterial blood and inspired gas assume a constant C(a-v)O2. Though variations in C(a-v)O2 are recognized, indices such as PaO2/FIO2 remain popular and are often considered the best measure of pulmonary oxygen transfer in critically ill patients. This study estimated the effect of within-subject variations in C(a-v)O2 and FIO2 on venous admixture (Qs/Qt), the calculated oxygen content difference between end-capillary and arterial blood (Cc'O2-CaO2), the alveolar-arterial oxygen tension gradient (P(A-a)O2) and PaO2/FIO2, using a validated lung model of acute respiratory distress syndrome (ARDS). All four indices showed changes with FIO2 and C(a-v)O2, although the magnitude of changes in Qs/Qt was clinically unimportant (<2%). The other three indices showed larger variations that may potentially be misleading. At an FlO2 of 0.7, PaO2 /FIO2 varied between 18 and 10 kPa and at an FIO2 of 0.9 the ratio varied between 22 and 8 kPa. These changes, which were unrelated to underlying lung pathology, are sufficiently large to result in misclassification on the gas exchange scale suggested by the American European Consensus Conference on ARDS. This study shows there is no reliable alternative to Qs/Qt to quantify pulmonary oxygen transfer in critically ill patients.

Cardiac Output↗

Levobupivacaine for epidural analgesia in labor: the sparing effect of epidural fentanyl.

Evidence suggests that levobupivacaine has similar pharmacodynamic properties to racemic bupivacaine. We sought to investigate whether this similarity extends to opioid sparing when levobupivacaine is used for epidural analgesia in laboring women by quantifying the effect of fentanyl on the minimum local analgesic concentration (MLAC) of levobupivacaine. One-hundred-six women requesting epidural analgesia for labor pain were recruited in this randomized, double-blinded, up-down sequential allocation study. Each received 20 mL of one of three test solutions: levobupivacaine control, levobupivacaine and fentanyl 2 microg/mL, or levobupivacaine and fentanyl 3 microg/mL. The initial levobupivacaine concentration was 0.07% wt/vol in each group, with subsequent concentrations of levobupivacaine being determined by the response of the previous patient (testing interval 0.01% wt/vol). Efficacy was accepted if the visual analog score decreased to 10 mm or less on a 100-mm scale within 30 min. The MLAC of levobupivacaine in the control group was 0.091% wt/vol (95% CI, 0.052-0.130). Fentanyl at concentrations of 2 microg/mL and 3 microg/mL significantly reduced the MLAC of levobupivacaine to 0.047% wt/vol (95% CI, 0.023-0.072) and 0.050% wt/vol (95% CI, 0.035-0.065), respectively (P < 0.001). A dose-dependent effect was not demonstrated. We conclude that fentanyl significantly reduces levobupivacaine requirements for epidural analgesia in labor.

Adult↗

Minimum local analgesic dose of intrathecal bupivacaine in labor and the effect of intrathecal fentanyl.

BACKGROUND: Combining bupivacaine with fentanyl for intrathecal analgesia in labor is well recognized, but dosages commonly used are arbitrarily chosen and may be excessive. This study aimed to determine the median effective dose (ED50) of intrathecal bupivacaine, defined as the minimum local analgesic dose (MLAD), and then use this to assess the effect of different doses of fentanyl. METHODS: In this double-blind, randomized, prospective study, 124 parturients receiving combined spinal epidural analgesia at 2-6-cm cervical dilatation were allocated to one of four groups to receive bupivacaine alone or with 5, 15, or 25 microg fentanyl, using the technique of up-down sequential allocation. Analgesic effectiveness was assessed using 100-mm visual analog pain scores, with less than or equal to 10 mm within 15 min defined as effective. MLAD was calculated using the formula of Dixon and Massey. Pruritus and duration of spinal analgesia were also recorded. RESULTS: Minimum local analgesic dose of intrathecal bupivacaine was 1.99 mg (95% confidence interval, 1.71, 2.27). There were similar significant reductions in MLAD (P < 0.001) for all bupivacaine-fentanyl groups compared with bupivacaine control. There was a dose-dependent increase in both pruritus and duration of spinal analgesia with increasing fentanyl (P < 0.0001). CONCLUSION: Under the conditions of this study, the addition of intrathecal fentanyl 5 microg offers a similar significant bupivacaine dose-sparing effect as 15 and 25 microg. Analgesia in the first stage of labor can be achieved using lower doses of fentanyl, resulting in less pruritus but with a shortening of duration of action.

Adult↗

Comparison of superior vena caval and femoroiliac venous pressure measurements during normal and inverse ratio ventilation.

OBJECTIVE: The aim of this study was to estimate the agreement between superior vena caval pressure (SVCP) and femoroiliac venous pressure (FIVP) measurements by using short (<20 cm) femoral catheters commonly used in an adult intensive care unit. In addition, the effects of two modes of ventilation on agreement were assessed. DESIGN: Measurements of central venous pressure were recorded from both sites by using the same pressure transducer connected to the catheters via a three-way stopcock. SVCP and FIVP were recorded at 5-min intervals for 40 mins with the patient in the supine position. Recordings were taken from ventilated patients during a randomized crossover sequence of normal and inverse ratio ventilation (IRV). Analyses included Pearson's correlation (r), intraclass correlation (ri), Bland-Altman plots, and repeated measures analysis of variance with crossover tests for period and period-treatment interactions. SETTING: Adult intensive care unit. PATIENTS: Adult intensive care patients. MEASUREMENTS: Central venous pressure. RESULTS: Twenty-two patients were enrolled in the study, giving 162 paired measurements; r was .97 (p < .0001), and ri was .96. The bias for SVCP-FIVP measurements was -0.75 mm Hg (95% confidence interval = -1.31 to -0.18), with 95% limits of agreement of -3.30 to 1.81 mm Hg. Seventeen patients were suitable for randomization to normal ratio ventilation and IRV. IRV significantly increased SVCP and FIVP (p < .002). Tests for the effect of mode of ventilation on agreement (p = .36), for period (p = .26), and for period-treatment interaction (p = .84) were not significant. CONCLUSION: The study showed excellent overall agreement with acceptable clinical agreement for SVCP and FIVP measurements that was not affected by changing the mode of ventilation. IRV significantly increased central venous pressure measurements from both catheter sites but had no effect on overall agreement.

Adult↗

Thromboelastography identifies sex-related differences in coagulation.

UNLABELLED: Thromboelastography is an in vitro, point-of-care monitor of whole blood coagulation. Thromboelastography studies have demonstrated a hypercoagulable state during pregnancy. Perhaps the hypercoagulability is attributable to female sex hormones. The aim of the study was to determine if sex, in addition to pregnancy, affected thromboelastography variables by studying male and female (pregnant and nonpregnant) volunteers. Thromboelastography showed significant (P:<0.01) differences in sex, with a significant (P: < 0. 0001) trend of increasing whole blood coagulability from men through nonpregnant to pregnant women. The thromboelastograph, used as a diagnostic tool, shows that women have more whole blood coagulability than men. IMPLICATIONS: The thromboelastograph, used as a diagnostic tool, shows that women have more whole blood coagulability than men.

Adult↗

Effect of intravenous versus epidural fentanyl on the minimum local analgesic concentration of epidural bupivacaine in labor.

BACKGROUND: The minimum local analgesic concentration (MLAC) has been defined as the median effective local analgesic concentration (EC50) in a 20-ml volume for epidural analgesia in the first stage of labor. The aim of this study was to determine the relative local anesthetic sparing efficacies of intravenous and epidural fentanyl by comparison of their effects on the MLAC of bupivacaine. METHODS: In this double-blind, randomized, prospective study, 84 parturients at < or = 7-cm cervical dilation who requested epidural analgesia were allocated to one of two groups. After lumbar epidural catheter placement, 20 ml bupivacaine (n = 44) or bupivacaine with 3 microg/ml (60 microg) fentanyl (n = 40) was administered. The plain bupivacaine group then received 60 microg intravenous fentanyl. The bupivacaine-fentanyl group received intravenous saline. The concentration of bupivacaine was determined by the response of the previous patient in that group to a higher or lower concentration using up-down sequential allocation. Analgesic efficacy was assessed using 100-mm visual analog pain scores, with < or = 10 mm within 30 min define as effective. RESULTS: The MLAC of bupivacaine-intravenous fentanyl was 0.064% wt/vol (95% confidence interval, 0.049-0.080), and the MLAC of bupivacaine-epidural fentanyl was 0.034% wt/vol (95% confidence interval, 0.017-0.050). Epidural fentanyl significantly increased the analgesic potency of bupivacaine by a factor of 1.88 (95% confidence interval, 1.09-3.67) compared with intravenous fentanyl. The epidural fentanyl group demonstrated significantly higher dermatomal spread (P = 0.0064) and increased pruritus (P = 0. 01). CONCLUSIONS: Epidural fentanyl significantly reduced the MLAC of bupivacaine when compared with intravenous fentanyl for the parturients in this study. The significantly enhanced local anesthetic sparing, dermatomal level, and pruritus with epidural fentanyl suggest a primarily spinal site of action.

Adult↗

Relative analgesic potencies of ropivacaine and bupivacaine for epidural analgesia in labor: implications for therapeutic indexes.

BACKGROUND: The minimum local analgesic concentration (MLAC) has been defined as the median effective local analgesic concentration in a 20-ml volume for epidural analgesia in the first stage of labor. The aim of this study was to assess the relative analgesic potencies of epidural bupivacaine and ropivacaine by determining their respective minimum local analgesic concentrations. METHODS: Seventy-three parturients at < or = 7 cm cervical dilation who requested epidural analgesia were allocated to one of two groups in this double-blinded, randomized, prospective study. After a lumbar epidural catheter was placed, 20 ml of the test solution was given, either ropivacaine (n = 34) or bupivacaine (n = 39). The concentration of local anesthetic was determined by the response of the previous patient in that group to a higher or lower concentration using up-down sequential allocation. Analgesic efficacy was assessed using 100-mm visual analog pain scores with < or = 10 mm within 30 min defined as effective. An effective result directed a 0.01% wt/vol decrement for the next patient. An ineffective result directed a 0.01% wt/vol increment. RESULTS: The minimum local analgesic concentration of ropivacaine was 0.111% wt/vol (95% confidence interval, 0.100-0.122), and the minimum local analgesic concentration of bupivacaine was 0.067% wt/vol (95% confidence interval, 0.052-0.082). Ropivacaine was significantly less potent than bupivacaine, with a potency ratio of 0.6 (95% confidence interval, 0.49-0.74). No difference in motor effects was observed. CONCLUSION: Ropivacaine was significantly less potent than bupivacaine for epidural analgesia in the first stage of labor.

Adult↗

Dose-dependent reduction of the minimum local analgesic concentration of bupivacaine by sufentanil for epidural analgesia in labor.

BACKGROUND: The minimum local analgesic concentration (MLAC) has been defined as the median effective local analgesic concentration in a 20-ml volume for epidural analgesia in the first stage of labor. The aim of this study was to determine the local anesthetic-sparing efficacy of epidural sufentanil by its effect on the MLAC of bupivacaine. METHODS: In this double-blind, randomized, prospective study, 147 parturients at < or = 7 cm cervical dilation who requested epidural analgesia were allocated to one of four study groups. After a lumbar epidural catheter was placed, study participants received 20 ml bupivacaine (n = 38), bupivacaine with sufentanil 0.5 microg/ml (n = 38), bupivacaine with sufentanil 1 microg/ml (n = 33), or bupivacaine with sufentanil 1.5 microg/ml (n = 38). The concentration of bupivacaine was determined by the response of the previous patient using up-down sequential allocation. The analgesic efficacy was assessed using 100-mm visual analog pain scores, with < or = 10 mm within 30 min defined as effective. RESULTS: The MLAC of bupivacaine alone was 0.104% wt/vol (95% CI, 0.090-0.117). The addition of sufentanil at doses of 0.5 microg/ml, 1 microg/ml, and 1.5 microg/ml resulted in significant reductions (P < 0.0001) in the MLAC of bupivacaine to 0.048% wt/vol (95% CI, 0.030- 0.065), 0.021% wt/vol (95% CI, 0-0.055), and 0.009% wt/vol (95% CI, 0-0.023), respectively. CONCLUSIONS: This study showed a significant (P < 0.0001) dose-dependent reduction in the MLAC ofbupivacaine by sufentanil.

Analgesia, Epidural↗

Effect of propofol and thiopentone on free radical mediated oxidative stress of the erythrocyte.

Propofol has free radical scavenging properties similar to those of recognized phenol-based antioxidants. We have examined these properties in an in vitro model of radical-induced cellular injury, comparing its activity with that of thiopentone (which has also been shown to have radical scavenging activity). Haemolysis of human erythrocytes was induced using the azo compound 2,2'-azo-bis(2-amidinopropane) dihydrochloride (ABAP). This was achieved by incubating a 10% suspension of erythrocytes with ABAP 100 mmol litre-1 at 37 degrees C. For propofol, at concentrations of 12.5, 25 and 50 mumol litre-1, the times to achieve 50% haemolysis were mean 126 (SEM 7) min (95% confidence interval 108-144 min), 150 (8) (129-170) min and 182 (12) (160-180) min, respectively (Intralipid control 107 (7) (90-125) min, ANOVA P < 0.0001). For thiopentone, at concentrations of 62.5, 125 and 250 mumol litre-1, the values were 117 (2) (112-121) min, 126 (3) (119-133) min and 138 (2) (132-144) min, respectively (saline control 109 (2) (104-113) min, ANOVA P < 0.0001). Spectroscopic analysis in the visible and ultraviolet spectra demonstrated a steady increase in the proportion of methaemoglobin during haemolysis, with the highest concentrations in the propofol-containing flasks. The formation of methaemoglobin was preceded by the generation of ferrylhaemoglobin (a Fe4+ haemoglobin species). Further experiments examining oxidation of purified methaemoglobin to ferrylhaemoglobin by hydrogen peroxide suggested that propofol, but not Intralipid or thiopentone, reduced ferrylhaemoglobin back to the met- state, and thereby explained the higher concentrations of methaemoglobin in the propofol-containing erythrocyte suspensions. We conclude that propofol is a more potent free radical scavenger in this model of oxidant stress than thiopentone, and that reduction of high oxidation states of haemoglobin may contribute to such activity.

Adult↗

The effect of epidural fentanyl on the minimum local analgesic concentration of epidural chloroprocaine in labor.

The minimum local analgesic concentration (MLAC) has been defined as the median effective local analgesic concentration (EC50) in a 20-mL volume in the first stage of labor. The aim of this study was to determine the local anesthetic sparing efficacy of epidural fentanyl by its effect on the MLAC of chloroprocaine. Fifty-six parturients, not exceeding 7 cm cervical dilation, who requested epidural analgesia were allocated to one of two groups in this double-blind, randomized, prospective study. After placing a lumbar epidural catheter, 20 mL of the solution being tested was given: chloroprocaine (n = 28) or chloroprocaine with fentanyl 3 micrograms/mL (60 micrograms) (n = 28). The concentration of chloroprocaine was determined by the response of the previous patient to a higher or lower concentration using up-down sequential allocation. Analgesic efficacy was assessed using 100-mm visual analog pain scores with 10 mm or less within 30 min defined as effective. The MLAC of chloroprocaine was reduced from 0.43% wt/vol to 0.26% wt/vol by fentanyl (P = 0.023). Thus, the addition of epidural fentanyl 3 micrograms/mL (60 micrograms resulted in a significant 40% reduction in the MLAC of chloroprocaine in the first stage of labor.

Adult↗