Search PubMed⌕ Search

Biomedical subjects

M Neo

Publications and source records attributed to M Neo.

At least 19 recordsLinked to original sources

Efficacy of computer-assisted pedicle screw insertion for cervical instability in RA patients.

We evaluated the efficacy of the computer-assisted cervical pedicle screw insertion, compared with those inserted without the help of the system on the cervix of rheumatoid arthritis (RA) patients. Eighty-six cervical pedicle screws were inserted without the help of the system. Of the 86, 59 screws were in non-RA patients with degenerative spine, and 27 were in RA patients. The accuracy of the screw insertions was evaluated by a CT-based method. Then, 25 screws were inserted with the system into the cervical spines between C2 and C6 in RA patients (Navigation group). The efficacy of the system was assessed by the CT-based method, compared with 27 screws inserted without the system (Conventional group). The screws in RA patients tended to be more deviated than those in non-RA patients. In Conventional group, four screws (15%) were placed far laterally, and two (7%), far medially. In contrast, no screw was placed far laterally or medially in Navigation group (P < 0.05).

Adult↗

Bone-bonding ability of a hydroxyapatite coated zirconia-alumina nanocomposite with a microporous surface.

Using a combination of hydroxyapatite (HA) coating and microporous surface treatment, bone-bonding ability was given to composites of ceria-stabilized tetragonal zirconia and alumina (CZA), which possesses excellent mechanical and wear properties and phase stability. Four types of CZA plates (2 x 10 x 15 mm3) were prepared for this study, which were CZA with a polished surface (group 1), a microporous surface prepared by hydrofluoric acid and heat treatment (group 2), a microporous surface with a submicron HA coating prepared by alternately soaking the plate from group 2 in aqueous CaCl2/HCl and Na2HPO4 solutions (group 3), and a microporous surface with a 4-microm HA coating prepared by the biomimetic method, where the plates from group 3 were soaked in simulated body fluid (group 4). Plates were implanted into rabbit tibia, and after 4, 8, and 16 weeks, tensile testing and histological examination of the bone-implant interface were conducted. At 4 weeks, group 4 had superior bone-bonding ability compared with other implants, which was maintained at the later postimplantation times. This HA-coated CZA with a microporous surface has the possibility of clinical use as a bearing material in cementless joint prostheses or as a load-bearing bone substitute.

Aluminum Oxide↗

Tissue responses around polymethylmethacrylate particles implanted into bone: analysis of expression of bone matrix protein mRNAs by in situ hybridization.

Tissue responses around implanted polymethylmethacrylate (PMMA) particles were analyzed by in situ hybridization with digoxigenin-labeled procollagen alpha1(I) (COL), osteonectin, osteocalcin, and osteopontin (OPN) mRNA probes. PMMA particles (150-300 microm in diameter) were implanted into rat tibiae, and specimens were collected at 3, 5, 7, and 10 days after operation. New bone was formed centripetally, and bone-forming osteoblasts expressed all four kinds of mRNAs. A COL signal was expressed most strongly and widely. In the early stage, COL-positive cells were detected on and among particles sporadically. A COL signal was rarely detected in cells on the surfaces of the particles, suggesting that PMMA particles may suppress osteoblast differentiation. Osteonectin and osteocalcin mRNAs were expressed in bone-forming osteoblasts in a similar pattern by day 7. By contrast, an OPN signal was detected mainly on the particles, not only in COL-positive osteoblasts but also in COL-negative round cells. The latter cells had acid phosphatase activity, suggesting that they might be macrophages responding to a foreign body. At day 10, an OPN signal was detected continuously in multinucleated cells on PMMA particles, whereas new bone was formed away from particles. Our approach helped us to understand the initial cellular reaction to materials, which may determine their biocompatibility.

Animals↗

Bone bonding in sintered hydroxyapatite combined with a new synthesized agent, TAK-778.

We studied the stimulatory effects of TAK-778, a new synthetic 3-benzothiepin derivative that promotes osteoblast differentiation, in bone bonding to sintered hydroxyapatite implants in rabbit tibiae. Smooth-surfaced rectangular plates (15 x 10 x 2 mm) made of sintered hydroxyapatite were implanted into the proximal metaphyses of bilateral rabbit tibiae, with TAK-778-containing sustained-release microcapsules packed into the medullary cavity in one limb and untreated microcapsules packed in the contralateral limb to serve as a paired control. At 4, 8, and 16 weeks after implantation, bone bonding at the bone-implant interfaces was evaluated by a detaching test and undecalcified histological examination. The tensile failure load increased from 4 to 16 weeks for both groups; however, the tensile failure load of the TAK-778-treated group was significantly greater than that of the control group at each interval after implantation. Histologically, the TAK-778-treated specimens showed greater active new bone formation mainly in the medullary cavity and more extensive bonding between the implant and bone than the untreated specimens. The results of this study suggest that adding osteoinductive TAK-778 to hydroxyapatite implants may significantly accelerate bone apposition to the implants and improve the bonding process at the interface. This would help to establish an earlier and stronger bonding of orthopedic ceramic implants between the surrounding bone tissue.

Absorbable Implants↗

Alkali- and heat-treated porous titanium for orthopedic implants.

This study was carried out to investigate the effects of the alkali and heat treatments on the bone-bonding behavior of porous titanium implants. Porous titanium implants had a 4.6 mm solid core and a 0.7 mm thick porous outer layer using pure titanium plasma-spray technique. Three types of porous implants were prepared from these pieces: 1.control implant (CL implant) as manufactured 2.AW-glass ceramic bottom-coated implant (AW implant) in which AW-glass ceramic was coated on only the bottom of the pore of the implant 3.alkali- and heat-treated implant (AH implant), where implants were immersed in 5 mol/L NaOH solution at 60 degrees C for 24 h and subsequently heated at 600 degrees C for 1 h. The implants were inserted into bilateral femora of six dogs hemi-transcortically in a randomized manner. At 4 weeks, push-out tests revealed that the mean shear strengths of the CL, AW, and AH implants were about 10.8, 12.7, and 15.0 MPa, respectively. At 12 weeks there was no significant difference between the bonding strengths of the three types of the porous implants (16.0-16.7 MPa). Histologically and histomorphologically, direct bone contact with the implant surface was significantly higher in the AH implants than the CL and AW implants both at 4 and 12 weeks. Thus, the higher bonding strength between bone and alkali- and heat-treated titanium implants was attributed to the direct bonding between bone and titanium surface. In conclusion, alkali and heat treatments can provide porous titanium implants with earlier stable fixation.

Animals↗

Effects of apatite and wollastonite containing glass-ceramic powder and two types of alumina powder in composites on osteoblastic differentiation of bone marrow cells.

Previously we developed a composite consisting of apatite and wollastonite containing glass-ceramic (AW-GC) powder and bisphenol-a-glycidyldimethacrylate (Bis-GMA)-based resin (designated AWC), and demonstrated that AWC showed direct contact with living bone. Another new composite consisting of mainly the delta-crystal phase of alumina bead powder and Bis-GMA-based resin (designated ABC) was developed. Although alumina ceramics are bioinert and a composite filled with the pure alpha-crystal phase of alumina powder (designated alphaALC) did not allow direct bone formation in vivo, ABC was shown to have excellent osteoconductivity. One purpose of this study was to investigate whether AW-GC powder in a composite promotes osteoblastic differentiation of rat bone marrow cells as AW-GC bulk did. Another purpose was to evaluate the effects of the delta-crystal phase of alumina powder in a composite on osteoblastic differentiation. In a cell culture with dexamethasone, alkaline phosphatase (AP) activity at both days 7 and 14, and the levels of osteocalcin mRNA and alpha1(I) collagen mRNA at day 14 and osteopontin mRNA at day 7, were highest on AWC, followed by ABC, and finally alphaALC. Scanning electron microscopy showed more abundant mineralized globules and a fibrous collagen matrix on AWC at day 14, followed by ABC. In a cell culture without dexamethasone, AP activity at both days 7 and 14, and the level of osteopontin mRNA at day 7, were higher on ABC than on any other composite, whereas osteocalcin mRNA could not be detected. These results indicate that AW-GC powder in a composite promotes osteoblastic differentiation of bone marrow cells intensively when supplemented with dexamethasone. The delta-crystal phase of alumina powder in a composite promotes greater osteoblastic differentiation than the alpha-crystal phase of alumina powder.

Alkaline Phosphatase↗

Ultrastructure of the interface between bioactive composite and bone: comparison of apatite and wollastonite containing glass-ceramic filler with hydroxyapatite and beta-tricalcium phosphate fillers.

We have developed a bioactive bone cement that consists of apatite and wollastonite containing glass-ceramic (AW-GC) powder and bisphenol-a-glycidyl dimethacrylate (Bis-GMA)-based resin. In this study, we made three types of composite (designated AWC, HAC, and TCPC) consisting of AW-GC, hydroxyapatite (HA,) or beta-tricalcium phosphate (beta-TCP) powder as the inorganic filler and Bis-GMA-based resin as the organic matrix. The proportion by weight of the filler mixed into the cement was 70%. Rectangular plates (10 x 15 x 2 mm) of each composite were made and abraded with 2000 alumina powder. These composites were implanted into tibial metaphyses of rabbits. Specimens were prepared 10 and 25 weeks after implantation and examined using transmission electron microscopy (TEM). AWC was in direct contact with bone 10 weeks after implantation, and AW-GC particles were partially absorbed at the surface. HAC was in contact with partially mineralized extracellular matrix 10 weeks after implantation. In TCPC-implanted specimens, randomly oriented mineral was observed 10 weeks after implantation; however, collagenous extracellular matrix rarely was observed. In 25-week specimens, AW-GC particles were completely absorbed and replaced by new bone, and there was no intervening soft tissue. Both HAC and TCPC were in contact with bone at 25 weeks. These results indicate that AWC has higher bioactivity than either HAC or TCPC.

Animals↗

Bone bonding in bioactive glass ceramics combined with a new synthesized agent TAK-778.

We studied the stimulatory effects of TAK-778, a new synthetic 3-benzothiepin derivative that promotes osteoblast differentiation, in the bonding of bone to bioactive glass ceramic implants in rabbit tibiae. Smooth-surfaced, rectangular plates (15 x 10 x 2 mm) made of apatite-wollastonite-containing glass ceramic were implanted bilaterally into the proximal metaphyses of rabbit tibiae. Sustained-release microcapsules containing TAK-778 were packed into the medullary cavity in one limb and untreated microcapsules were packed into the contralateral limb to serve as a paired control. At 4, 8, and 16 weeks after implantation, bonding at the bone/implant interfaces was evaluated using a detaching test and histological examination of undecalcified specimens. The tensile failure load increased during weeks 4 to 16 in both groups; the tensile failure load in the TAK-778-treated group was significantly greater than that in the control group at each interval after implantation. Histologically, the TAK-778-treated specimens showed greater active new bone formation mainly in the medullary cavity and more extensive bonding between the implant and bone than the untreated specimens. The results of this study suggest that adding the bone formation-promoting TAK-778 to bioactive glass ceramic implants may significantly accelerate bone apposition to the implants and improve the bonding process at the interface. This would help to establish earlier and stronger bonding of orthopedic ceramic implants to the surrounding bone tissue.

Animals↗

Delayed aortic rupture caused by an implanted anterior spinal device. Case report.

The authors describe a case of delayed aortic rupture following the application of a smooth-rod Kaneda (SRK) instrument. This is a rare but critical complication of anterior spinal fusion in which instrumentation is placed, and the authors wish to draw attention to the possible complications arising from such surgery. A few cases of this complication were reported in 1986. No reports have been published since then; perhaps because techniques and implant design have improved. In this case, a 53-year-old man suffered a T-11 fracture and related paraparesis, and he underwent decompression and anterior fusion in which an iliac bone graft was placed using an SRK device. Although his neurological deficit resolved postoperatively, nonunion of the grafted bone caused progressive kyphosis of the thoracolumbar spine. Twenty months after surgery, he complained of progressive gastrointestinal symptoms, and a delayed aortic rupture with a pseudoaneurysm was found surrounding the implant. The aortic pseudoaneurysm was replaced with an artificial vessel, and the SRK device was removed immediately. Delayed aortic rupture associated with anterior instrumentation is extremely rare but can occur. Even if the design of the implants can be improved, the placement of implants near the aorta and subsequent changes in the close anatomical relationship between the aorta and the implant eventually may result in this life-threatening complication. Careful follow-up examination and early removal of the implant, if necessary, are important.

Aneurysm, False↗

The effect of alkali- and heat-treated titanium and apatite-formed titanium on osteoblastic differentiation of bone marrow cells.

This study was based on the hypothesis that osteogenesis is enhanced by growth of osteogenic cells on an apatitic surface. To test this hypothesis, the behavior of rat bone marrow cells on these surfaces was examined: commercially pure titanium (Cp Ti), alkali- and heat-treated titanium (AH Ti), and AH Ti incubated in a simulated body fluid to deposit crystalline hydroxyapatite on the surface (Ap Ti). The alkaline phosphatase (ALP) activity of the cells cultured on Ap Ti was significantly higher at day 7 and day 14 than the ALP activity observed for the other titanium surfaces. At day 14, the ALP activity on AH Ti was significantly increased compared with the ALP activity on Cp Ti. The amount of DNA per well increased nearly in parallel for each titanium. However, northern blot analysis at day 14 revealed that expression of osteocalcin and alpha1(I) collagen mRNA was higher in the cells cultured on Ap Ti than the cells cultured on AH Ti. The cells cultured on Cp Ti showed the lowest mRNA levels. After 7 days of cell-free culture in medium supplemented with 15% serum, X-ray photoelectron spectroscopy (XPS), and thin-film X-ray diffraction (TF-XRD) analysis showed that calcium phosphate had been deposited on the AH Ti (resulting in an increase in thickness with time). No phosphate was detected on the Cp Ti, even after day 14. This study indicates that Ap Ti provides the most favorable conditions for differentiation of bone marrow cells, and, at a later stage, AH Ti also provides favorable conditions, perhaps because of the formation of a surface layer of calcium phosphate. This potential for apatite formation may play an important role in osteoblastic differentiation.

Alkaline Phosphatase↗

The expression of bone matrix protein mRNAs around beta-TCP particles implanted into bone.

Tissue response around beta-tricalcium phosphate (beta-TCP) particles (150-300 microm in diameter) implanted into rat tibiae was analyzed by in situ hybridization with digoxigenin-labeled procollagen alpha1(I) (COL), osteonectin, osteocalcin, and osteopontin (OPN) RNA probes. Specimens were collected at 3, 5, 7, and 10 days after the operation. Holes without implantation were used as control. In both the beta-TCP implanted and control groups, new bone was formed centripetally and all four kinds of mRNA were expressed in activated osteoblasts. A COL signal was expressed most strongly and widely, and was detected at the peripheral region of the hole at day 3. The other three mRNAs were also expressed in bone forming osteoblasts by day 7. However, in the earlier cell reaction stage, OPN expression in the beta-TCP implanted group was different than that in the control group: OPN mRNA was seen exclusively in the cells on the particles, and an OPN signal was detected not only in COL-positive cells, but also in COL-negative cells. The former cells may be osteoblasts and reflect the early process of bone formation on biomaterials. The latter cells may be macrophages and reflect foreign body reactions. Expression of these OPN mRNAs induced by implantation of beta-TCP may play a role in bone formation on the materials and in determining their biocompatibility.

Animals↗

Pseudoaneurysm of the deep circumflex iliac artery: a rare complication at an anterior iliac bone graft donor site.

STUDY DESIGN: The formation of a pseudoaneurysm of the deep circumflex iliac artery after the harvesting of an anterior iliac bone graft for spinal fusion is reported. OBJECTIVE: To describe a rare complication at an iliac bone graft donor site. SUMMARY OF BACKGROUND DATA: The iliac bone is a common site for harvesting bone for spinal surgery. Although many complications have been reported, vascular injuries associated with this procedure are rare. To the authors' knowledge, deep circumflex iliac artery injury has not been reported as a complication. METHODS: A 70-year-old man with cervical myelopathy underwent anterior cervical decompression and fusion with an anterior iliac bone graft. Fracture displacement of the anterior superior iliac spine at the donor site was noted 1 week after a second operation, which was performed to reduce the displaced grafted bone. Five months after the second operation, he reported pain and swelling at the donor site. Removal of a hematoma was attempted, which led to massive bleeding that was difficult to control. RESULTS: Angiography demonstrated a pseudoaneurysm of the deep circumflex iliac artery. Selective embolization of the artery was performed, and the bleeding was arrested. CONCLUSIONS: Vascular injury after anterior iliac bone harvesting is rare but can occur. Selective arterial embolization was an effective solution.

Aged↗

Alumina powder/Bis-GMA composite: effect of filler content on mechanical properties and osteoconductivity.

Three composites consisting of alumina powder dispersed in a bisphenol-a-glycidyl methacrylate (Bis-GMA) matrix were prepared and evaluated to assess the effect of alumina powder content on the mechanical properties and osteoconductivity of the composite. The alumina powder composites (APC) consisted of alumina powder (AL-P) as the inorganic filler dispersed in a Bis-GMA matrix that was solidified by a radical polymerization process. Prior to polymerization the AL-P was mixed with the monomers in proportions of 50%, 70%, and 80% by weight (APC50, APC70, and APC80). A fused silica-glass-filled composite containing 70% glass by weight (SGC70) was used as a control. The compressive and bending strengths, the elastic modulus in bending, and the bending strain of the composites increased as the AL-P content increased. We also evaluated the composites in vivo by implanting them into the medullary canals of rat tibiae. To compare the osteoconductivity of the composites, an affinity index was calculated for each composite; the affinity index equals the length of a bone in direct apposition to the composite and is expressed as a percentage of the total length of the composite surface. Microradiographic examination for periods of up to 26 weeks after implantation revealed that APC50, APC70, and APC80 all exhibited excellent osteoconductivity and made direct contact with the bone with no interposed soft tissues. However, the higher the AL-P content of the composite, the higher the osteoconductivity, especially at 4 weeks after the operation. Moreover, the amount of bone directly apposed to the composite surface increased with time. In contrast, little bone formation was seen on the surface of SGC70, even after 26 weeks. Observation by scanning electron microscope-energy dispersive X-ray microanalysis demonstrated that bone made direct contact with the APC surface through a layer containing calcium, phosphorus, and alumina powder. These results suggest that APC shows promise as a basis for developing mechanically strong and highly osteoconductive composites.

Aluminum Oxide↗

Bioactive bone cement: effect of surface curing properties on bone-bonding strength.

The fact that bisphenol-a-glycidyl methacrylate (bis-GMA)-based cements contain an uncured surface is believed to play an important role when determining the surface curing properties of the cements. Therefore, in the present study, the bone-bonding strength of cement plates having an uncured surface on one side and a cured surface on the other side has been evaluated. These cement plates were composites of a bis-GMA-based resin with either an apatite- and wollastonite-containing glass-ceramic (AW-GC) powder or a hydroxyapatite (HA) powder, respectively designated AWC and HAC. The amount of each of these powders in a composite cement was 70 wt %. We formulate the hypothesis that the uncured surface of a cement plate is bioactive having bone-bonding properties. The goal of the present study was to indicate the bone-bonding strength of the uncured surfaces of AWC and HAC and compare the strength with the respective cured surfaces by a detaching in vivo test, as well as to histologically examine the bone-cement interface. Each plate has been implanted into the tibiae of male Japanese white rabbits, taking care to retain the surface properties, and the so-called "failure load has been measured using a detaching test followed 8 weeks after implantation. The failure load for AWC-plates at the uncured surface (2.05 +/- 1.11 kgf, n = 8) was significantly higher than AWC at its cured surface side (0.28 +/- 0.64 kgf, n = 8). The failure load for HAC-plates at the uncured surfaces (1.40 +/- 0.68 kgf, n = 8) was significantly higher than HAC at its cured surface (0.00 +/- 0.00 kgf, n = 8). Failure loads for AWC at its uncured and cured surfaces were both higher than for HAC, although not significantly. Direct bone formation has been observed histologically for both AWC and HAC on the uncured surfaces, and a Ca-P-rich layer was observed only at the uncured surface of AWC. These findings strongly suggest that uncured surfaces are useful for exposing a bioactive filler on a surface of composites, being very effective in inducing bone bonding.

Animals↗

Ultrastructure of the interface between alumina bead composite and bone.

We developed a composite (ABC) consisting of alumina bead powder as an inorganic filler and bisphenol-a-glycidyl dimethacrylate (Bis-GMA)-based resin as an organic matrix. Alumina bead powder was manufactured by fusing crushed alpha-alumina powder and quenching it. The beads took a spherical form 3 microm in average diameter. The proportion of filler in the composites was 70% w/w. The composite was implanted into rat tibiae and cured in situ. Specimens were prepared 1, 2, 4, and 8 weeks after the operation and observed by transmission electron microscopy. The results were compared with those of a bone composite made of alpha-alumina powder (alpha-ALC). In ABC-implanted tibiae, the uncured surface layer of Bis-GMA-based resin was completely filled with newly formed bonelike tissue 2 weeks after implantation. The alumina bead fillers were surrounded by and in contact with bonelike tissue. No intervening soft tissue was seen. In alpha-ALC-implanted tibiae, a gap was always observed between the alpha-ALC and the bonelike tissue. These results indicate that the ABC has osteoconductivity, although the precise mechanism is still unclear.

Aluminum Oxide↗

Bioactive polymethyl methacrylate-based bone cement: comparison of glass beads, apatite- and wollastonite-containing glass-ceramic, and hydroxyapatite fillers on mechanical and biological properties.

A new bioactive bone cement (designated GBC) consisting of polymethyl methacrylate (PMMA) as an organic matrix and bioactive glass beads as an inorganic filler has been developed. The bioactive beads, consisting of MgO-CaO-SiO(2)-P(2)O(5)-CaF(2) glass, have been newly designed, and a novel PMMA powder was selected. The purpose of the present study was to compare this new bone cement GBC's mechanical properties in vitro and its osteoconductivity in vivo with cements consisting of the same matrix as GBC and either apatite- and wollastonite-containing glass-ceramic (AW-GC) powder (designated AWC) or sintered hydroxyapatite (HA) powder (HAC). Each filler added to the cements amounted to 70 wt %. The bending strength of GBC was significantly higher than that of AWC and HAC (p < 0.0001). Cements were packed into intramedullar canals of rat tibiae in order to evaluate osteoconductivity as determined by an affinity index. Rats were sacrificed at 2, 4, and 8 weeks after operation. An affinity index, which equaled the length of bone in direct contact with the cement expressed as a percentage of the total length of the cement surface, was calculated for each cement. At each time interval studied, GBC showed a significantly higher affinity index than AWC or HAC up to 8 weeks after implantation (p < 0.03). The value for GBC increased significantly with time up to 8 weeks (p < 0.006). The handling property of GBC was comparable with that of PMMA bone cement. Our study revealed that the higher osteoconductivity of GBC was due to the higher bioactivity of the bioactive glass beads at the cement surface and the lower solubility of the new PMMA powder to MMA monomer. In addition, it was found that the smaller spherical shape and glassy phase of the glass beads gave GBC strong enough mechanical properties to be useful under weight-bearing conditions. GBC shows promise as an alternative with improved properties to the conventionally used PMMA bone cement.

Animals↗

Reduction of blood loss using tranexamic acid in total knee and hip arthroplasties.

There have been several attempts to reduce postoperative blood loss in patients undergoing total arthroplasty. Benoni et al. reported the usefulness of tranexamic acid in total knee arthroplasty (TKA). We investigated its effect in TKA and total hip arthroplasty (THA). Blood loss was significantly reduced in patients given tranexamic acid in both the TKA and THA groups, and no severe complications, such as venous or pulmonary thrombosis, were noted in any of the patients who received the agent. Administration of tranexamic acid seems to be useful for reducing postoperative blood loss in TKA and THA.

Antifibrinolytic Agents↗

Biological and mechanical properties of PMMA-based bioactive bone cements.

We reported previously that a bioactive PMMA-based cement was obtained by using a dry method of silanation of apatite-wollastonite glass ceramic (AW-GC) particles, and using high molecular weight PMMA particles. But handling and mechanical properties of the cement were poor (Mousa et al., J Biomed Mater Res 1999;47:336-44). In the present study, we investigated the effect of the characteristics of PMMA powder on the cement. Different cements containing different PMMA powders (CMW1, Surgical Simplex, Palacos-R and other two types of PMMA powders with Mw 270,000 and 1,200,000) and AW-GC filler in 70 wt% ratio except Palacos-R (abbreviated as B-CMW1 and B-Surg Simp, B-Palacos 50 [50 wt% AW-GC filler] and B-Palacos 70 [70 wt% AW-GC filler], B-270 and B-1200) were made. Dough and setting times of B-CMW1, B-Surg Simp B-270 and B-1200 were similar to the commercial CMW1 cement which did not contain bioactive powder (C-CMW1), but B-palacos which contained large PMMA beads with high Mw had delayed setting time. B-270 had the highest bending strength among the tested cements. After 4 and 8 weeks of implantation in the medullary canals of rat tibiae, the bone-cement interface was examined using SEM. The affinity index of B-1200 was significantly higher than the other types of cements. B-270 showed good combination of handling properties, high mechanical properties and showed higher bioactivity with minimal soft tissue interposition between bone and cement compared with commercial PMMA bone cement. This may increase the strength of the bone-cement interface and increase the longevity of cemented arthroplasties.

Animals↗