Endogenous processes during long-term starvation in activated sludge performing enhanced biological phosphorus removal.

In many biological wastewater treatment systems, bacterial growth and the amount of active biomass are limited by the availability of substrate. Under these low growth conditions, endogenous processes have a significant influence on the amount of active biomass and therefore, the overall system performance. In enhanced biological phosphorus removal (EBPR) systems endogenous processes can also influence the levels of the internal storage compounds of the polyphosphate accumulating organisms (PAO), directly affecting phosphorus removal performance. The purpose of this study was to evaluate the significance of different endogenous processes that occur during the long-term starvation of EBPR sludge under aerobic and anaerobic conditions. Activated sludge obtained from a laboratory sequencing batch reactor was used to perform a series of batch starvation experiments. Under aerobic starvation conditions we observed a significant decay of PAO (first-order decay rate of 0.15/d) together with a rapid utilization of polyhydroxyalkanoates (PHA) and a slower utilization of glycogen and polyphosphate to generate maintenance energy. On the other hand, anaerobic starvation was best described by maintenance processes that rapidly reduce the levels of polyphosphate and glycogen under starvation conditions while no significant decay of PAO was observed. The endogenous utilization of glycogen for maintenance purposes is currently not included in available EBPR models. Our experimental results suggest that mathematical models for in EBPR should differentiate between aerobic and anaerobic endogenous processes, as they influence active biomass and storage products differently.

Aerobiosis↗

Towards a benchmark simulation model for plant-wide control strategy performance evaluation of WWTPs.

The COST/IWA benchmark simulation model has been available for seven years. Its primary purpose has been to create a platform for control strategy benchmarking of activated sludge processes. The fact that the benchmark has resulted in more than 100 publications, not only in Europe but also worldwide, demonstrates the interest in such a tool within the research community In this paper, an extension of the benchmark simulation model no 1 (BSM1) is proposed. This extension aims at facilitating control strategy development and performance evaluation at a plant-wide level and, consequently, includes both pre-treatment of wastewater as well as the processes describing sludge treatment. The motivation for the extension is the increasing interest and need to operate and control wastewater treatment systems not only at an individual process level but also on a plant-wide basis. To facilitate the changes, the evaluation period has been extended to one year. A prolonged evaluation period allows for long-term control strategies to be assessed and enables the use of control handles that cannot be evaluated in a realistic fashion in the one-week BSM1 evaluation period. In the paper, the extended plant layout is proposed and the new suggested process models are described briefly. Models for influent file design, the benchmarking procedure and the evaluation criteria are also discussed. And finally, some important remaining topics, for which consensus is required, are identified.

Benchmarking↗

Wastewater fingerprinting by UV-visible and synchronous fluorescence spectroscopy.

Municipal wastewater samples have been collected in three different types of community and fingerprinted by optical methods combining UV-visible spectrometry, synchronous fluorescence spectrometry and turbidity. Correlations, whose slope depends on the sampling location, were obtained between absorbance at 254 nm and the synchronous fluorescence intensity of peaks P1 (I366/316), P2 (I430/380) and P3 (I520/470). The corresponding correlation coefficients are larger than 0.75. Although related to urine as ammonia, the fluorescence intensity of P1 does not exhibit a strong correlation with this substance (correlation coefficient of approximately 0.6). All the measured parameters exhibit diurnal variation patterns related to human activities.

Humans↗

Implementing ADM1 for plant-wide benchmark simulations in Matlab/Simulink.

The IWA Anaerobic Digestion Model No.1 (ADM1) was presented in 2002 and is expected to represent the state-of-the-art model within this field in the future. Due to its complexity the implementation of the model is not a simple task and several computational aspects need to be considered, in particular if the ADM1 is to be included in dynamic simulations of plant-wide or even integrated systems. In this paper, the experiences gained from a Matlab/Simulink implementation of ADM1 into the extended COST/IWA Benchmark Simulation Model (BSM2) are presented. Aspects related to system stiffness, model interfacing with the ASM family, mass balances, acid-base equilibrium and algebraic solvers for pH and other troublesome state variables, numerical solvers and simulation time are discussed. The main conclusion is that if implemented properly, the ADM1 will also produce high-quality results in dynamic plant-wide simulations including noise, discrete sub-systems, etc. without imposing any major restrictions due to extensive computational efforts.

Anaerobiosis↗

Water resources management in soft drink industry-water use and wastewater generation.

Water is used in most process industries for a wide range of applications. Processes and systems using water today are being subjected to increasingly stringent environmental regulations on effluents and there is growing demand for fresh water. These changes have increased the need for better water management and wastewater minimisation. In Morocco, water use in the food and drink industry is extensive at approximately 24 million m3 per year including 14% of drinking water in 1994. This study was conducted in a carbonate soft drink industry plant, during two years, 2001 and 2002. We have investigated the state of consumption and use of fresh water and the generation of the effluent in the factory. The aim of the study is to identify potential opportunities for reducing fresh water intake and minimising wastewater production by studying the posibility of reuse, recycling and treatment.

Conservation of Natural Resources↗

Evaluation of microscopic techniques (epifluorescence microscopy, CLSM, TPE-LSM) as a basis for the quantitative image analysis of activated sludge.

Microscopic techniques ranging from epifluorescence microscopy to confocal laser scanning microscopy (CLSM) and two photon excitation laser scanning microscopy (TPE-LSM) combined with fluorescent stains can help to evaluate complex microbial aggregates such as activated sludge flocs. To determine the application limits of these microscopic techniques, activated sludge samples from three different sources were evaluated after staining with a fluorescent viability indicator (Baclight Bacterial Viability Kit, Molecular Probes). Image analysis routines were developed to quantify overall amounts of red and green stained cells, location of stained cells within the flocs, and the spatial organization in clusters and filaments. It was found that the selection of the appropriate microscopic technique depends strongly on the type of microbial aggregates being analyzed. For flocs with high cell density, the use of TPE-LSM is preferred, since it provides a clearer image of the internal structure of the aggregate. Epifluorescence microscopy did not allow to reliably quantify red stained cells in dense aggregates. CLSM did not adequately image the internal filamentous structure and the location of stained cells within dense flocs. However, for typical activated sludge flocs epifluorescence and CLSM proved adequate.

Flocculation↗

Morphology and viability analysis of Streptomyces clavuligerus in industrial cultivation systems.

The effects of varying inoculum age and production scale upon the morphology and viability of Streptomyces clavuligerus were studied by analyzing visible and fluorescent light images acquired throughout pilot-plant and pre-industrial scale fermentations. Changes in production scale reveal that in 5 m(3) fermentors, the maximum hyphal area obtained is double the value obtained in 0.5 m(3) fermentors. It is probably due to the higher shear stresses acting upon hyphae in the 0.5 m(3) fermentor caused by higher tip speeds observed in these. The morphological quantification based on elongation and branching rates allowed fermentations to be pattern classified into distinct physiological time zones namely elongation, branching, fragmentation, etc. The general pattern observed for fermentations inoculated with late exponential phase inocula was similar to the pattern of fermentations run with stationary phase inocula except that both the elongation and branching periods started earlier in the former case. Using the available staining technique and image acquisition system, the viability seemed to be generally high and constant throughout the time course of all the studied fermentations.

Bioreactors↗

Behaviour of Mycobacterium sp. NRRL B-3805 whole cells in aqueous, organic-aqueous and organic media studied by fluorescence microscopy.

The present work aimed at quantifying the viability and morphological changes occurring during the time course of the side-chain cleavage of beta-sitosterol, in aqueous, two-phase organic-aqueous and organic media by free resting cells of Mycobacterium sp. NRRL B-3805. The solvent used was bis(2-ethylhexyl) phthalate (BEHP). A 66.3% reduction in cell viability was observed after 24 h when the cells were incubated in phosphate buffer only, but the percentage of viable cells was constant thereafter. In biphasic systems with BEHP, cell viability was maintained at higher values in the first 48 h, during which complete degradation of substrate was achieved. The availability of oxygen, which should be higher in the biphasic system than in the aqueous system, and of a carbon and energy source, thus seem important for the cells to retain their viability. In biphasic systems, cells tended to shrink and decrease their surface roughness, i.e. to decrease their surface area, possibly as a way to protect themselves from mechanical stress due to the presence of organic-aqueous interfacial forces, which resulted in disaggregation of cell clusters. A method used to visualise BEHP droplets with a standard optical microscope showed that the cells adhered to the surface of the solvent droplets, but no cells were observed inside these. In pure BEHP medium, cells retained their viability level for at least 150 h, independently of a pre-incubation period, which did not seem to induce any adaptation effect. Solvent biocompatibility, higher oxygen availability and reduced interfacial stress could have contributed to this maintenance of viability.

Androstenedione↗

Setting-up a control simulation strategy for a sequencing batch reactor (SBR): application to municipal wastewater.

The use of a simulation model for setting up a control strategy for a sequencing batch reactor necessary for treating municipal wastewater is described. The model used is the ASM no 1 model. The objective of the pollution control treatment is the removal of carbon and nitrogen; the optimisation is concerned with the improvement in the biological removal of nitrogen. After experimental identification of the initialisation variables, the model enables different SBR control scenarios to be tested (time variation for each process) leading to the total elimination of nitrogen. The best simulation was tested in a laboratory reactor. On that scale, it was noted that denitrification is an endogenous process. Lastly, the control strategy was tested on a semi-industrial pilot working in a pollution control plant. Other control scenarios can be devised and tested by simulation, in order to improve the productivity of the reactor.

Bioreactors↗

Image analysis, methanogenic activity measurements, and molecular biological techniques to monitor granular sludge from an EGSB reactor fed with oleic acid.

Morphological changes in anaerobic granular sludge fed with increasing loads of oleic acid were quantified by image analysis. The combination of this technique with data on the accumulation of adsorbed long chain fatty acid and with the molecular characterization of microbial community gave insight into the mechanisms of sludge disintegration, flotation and washout. It was found that the bacterial domain was more affected than the archaeal domain during this process. However, no acetoclastic activity and onlya residual hydrogenotrophic activity were detected in the sludge at the end of the operation.

Adsorption↗

Implementation of storage tanks on the COST 624 benchmark.

To test the improvement that can be expected in terms of effluent quality of an wastewater treatment plant by activated sludge, an equalisation tank and a storm tank, designed to damp the influent variations under different weather conditions, have been implemented in front of a benchmark plant used to evaluate control strategies. The equalisation tank improves significantly the effluent quality in any weather condition but at a high operation cost due to extra pumping, while the storm tank without by-pass improves the effluent quality in rainy periods with a small increase in cost operation over the no tank case.

Benchmarking↗

Status and future trends of ICA in wastewater treatment--a European perspective.

The status of instrumentation, control and automation (ICA) within the European wastewater community is reviewed and some major incentives and bottlenecks are defined. Future trends of ICA are also discussed. The information is based on a COST 624 workshop and a non-exhaustive survey with regard to ICA carried out in 13 European countries during March 2001. The level of instrumentation (type of sensors, usage frequency, etc.) and how these instruments are used for on-line control purposes are presented for each individual country (Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Netherlands, Romania, Slovenia, Spain, Sweden and Switzerland). The most common types of applied real-time control in wastewater treatment plants are given. One conclusion of the paper is that sensors no longer represent the main bottleneck for on-line control, rather the lack of plant flexibility is more troublesome. Moreover, the current transitional phase of the wastewater industry in Europe represents a unique opportunity to apply ICA on a large scale. The driving forces are simply too strong to ignore.

Automation↗

Study of filamentous bacteria by image analysis and relation with settleability.

An automated procedure for the characterisation by image analysis of the morphology of activated sludge has been used to monitor the biomass in a pilot wastewater treatment plant during two runs inoculated with a different sludge and operated at two different temperatures. The bulking events were easily detected by image analysis. Correlations were found between settleability properties (Sludge Volume Index and settling velocity) and the morphological parameters (filament total length, filament number and floc size).

Bacteria↗

Use of image analysis and rheological studies for the control of settleability of filamentous bacteria: application in SBR reactor.

To monitor the ability of flocs to settle in Sequencing Batch Reactor sludge, two methods were tested during two operation cycles. Firstly, an automated image analysis procedure has been tested to quantify the floc size and the length and number of filaments. Secondly, rheological measurements (Bingham viscosity and shear stress) have been used to characterise the dispersion of the sludge which can reflect the cohesive strength of aggregates and so the influence of filamentous bacteria on rheological properties. These results were compared with settling parameters such as Sludge Volume Index or settling velocity. Correlations between the measured parameters with image analysis and parameters such as Sludge Volume Index have been obtained. If it is more difficult to analyze rheological results, it seems however that the thixotropy and the Bingham viscosity distinguish poor settlement owing to some filamentous bulking. The first results are promising, although they require confirmation in the long term.

Bacterial Physiological Phenomena↗

Automated monitoring of activated sludge in a pilot plant using image analysis.

An automated procedure for the characterisation by image analysis of the morphology of activated sludge has been used to monitor the biomass in a pilot wastewater treatment plant, in complement to the usual settleability (sludge volume index, settling velocity) and size distribution (by laser granulometry) measurements.

Automation↗

Biomass quantification by image analysis.

Microbiologists have always rely on microscopy to examine microorganisms. When microscopy, either optical or electron-based, is coupled to quantitative image analysis, the spectrum of potential applications is widened: counting, sizing, shape characterization, physiology assessment, analysis of visual texture, motility studies are now easily available for obtaining information on biomass. In this chapter the main tools used for cell visualization as well as the basic steps of image treatment are presented. General shape descriptors can be used to characterize the cell morphology, but special descriptors have been defined for filamentous microorganisms. Physiology assessment is often based on the use of fluorescent dyes. The quantitative analysis of visual texture is still limited in bioengineering but the characterization of the surface of microbial colonies may open new prospects, especially for cultures on solid substrates. In many occasions, the number of parameters extracted from images is so large that data-mining tools, such as Principal Components Analysis, are useful for summarizing the key pieces of information.

Algorithms↗

Physiological investigations by image analysis.

Modern quantitative image analysis has been extensively used to characterize the morphology of microorganisms, especially those of the filamentous type. More recently physiological features have been quantified, making use of classical stains as well as fluorescent dyes. The potential of the technique is illustrated by a detailed analysis of the differentiation of Streptomyces ambofaciens. Three different staining procedures have been used to monitor the thinning and septation of hyphae (with propidium iodide staining), the leakage of cellular components through the membrane (with carbol gentian violet staining) and the respiration (with INT staining) in a batch submerged culture.

Gentian Violet↗