Search PubMed⌕ Search

Biomedical subjects

M Motro

Publications and source records attributed to M Motro.

124 records · Page 7Linked to original sources

Clinical presentation and natural history of mild discrete subaortic stenosis. Follow-up of 1--17 years.

We report 21 patients with discrete subaortic stenosis (DSS) causing mild obstruction with a peak systolic left ventricular outflow pressure gradients less than 50 mm Hg. They were followed 1--17 years (mean 6.5 years), and eight were recatheterized before surgery, 2--17 years after the first cardiac catheterization. Three patients (14%) had subacute bacterial endocarditis. Ten (48%) had aortic insufficiency, one of whom had no pressure gradient across the left ventricular outflow tract. In three of the 10 patients, aortic insufficiency was found only at the second catheterization. Nine patients (43%) had hyperactive, asymmetric left ventricular contraction; in three, this finding was present only at the second catheterization. Seven of the eight patients who were recatheterized (33% of the entire group) showed an increase in gradient. The increase was from a mean gradient of 35.2 mm Hg to 76.7 mm Hg. Seventeen patients (81%) had at least one of these four features. In view of these data, we suggest that surgical indications for DSS might be expanded, although definitive recommendations are not possible. All cases of DSS should be carefully followed. Surgery should be performed if signs of progressive complications develop.

Adolescent↗

Coarctation of the aorta with congenital hemangioma of the face and neck and aneurysm or dilatation of a subclavian or innominate artery. A new syndrome?

Congenital cutaneous hemangioma associated with congenital heart disease is extremely rare. We report four infants with congenital cavernous hemangioma of the face and neck and coarctation of the aorta. Three also had congenital aneurysm of a subclavian or innominate artery. One patient also had mild congenital valvular aortic stenosis. The unusual combination of lesions may represent a new syndrome.

Aneurysm↗

Subaortic stenosis: an unrecognized problem in transposition of the great arteries.

Right ventricular (subaortic) obstruction has only rarely been described in complete transposition of the great arteries. five patients with complete transposition of the great arteries in whom subaortic stenosis was angiocardiographically demonstrated were studied. All had a pressure gradient of 30 to 55 mm Hg across the aortic outflow tract. Two of the patients manifested mild tricuspid insufficiency, and another two had coarctation of the aorta. The etiologic, anatomic, hemodynamic and prognostic aspects of this unusual anomaly are discussed. An angiocardiographically demonstrated series of this anomaly has not been reported on before.

Angiocardiography↗

Correlation between cardiac catheterization and echocardiography in assessing the severity of mitral stenosis.

During a 12-mth period 162 consecutive patients with mitral stenosis underwent examination by M-mode as well as cross-sectional echocardiography. The mitral valve area was measured by cross-sectional echocardiography ad the severity of mitral stenosis by M-mode echocardiography. Out of the total, 69 patients underwent left and right heart catheterization and in 53 of these the mitral valve area was calculated. A correlation of r=0.92 for the mitral valve area was found between sector scan echocardiography and cardiac catheterization, whereas the correlation between M-mode echocardiography and catheterization yielded a result of only r=0.38. Thus the assessment of the severity of mitral stenosis by cross-sectional echocardiography is a reliable alternative to cardiac catheterization.

Cardiac Catheterization↗

Pericardial tumor of fibrosis mimicking pericardial effusion by echocardiography.

Echocardiograms of three patients with metastatic carcinoma or lymphoma showed a sonolucent space posterior to the left ventricular epicardium, as seen in pericardial effusion. However, at surgery or autopsy no pericardial fluid was found. Instead, the pericardium was infiltrated by neoplastic tissue or fibrosis. In view of this finding, we suggest caution in the interpretation of "positive" echocardiograms for pericardial effusion in patients with neoplastic disease, especially if pericardiocentesis is being considered.

Adenocarcinoma↗

Value of Holter monitoring in assessing cardiac arrhythmias in symptomatic patients.

Holter electrocardiographic monitoring in 55 symptomatic patients with syncope, palpitations or dizziness uncovered significant arrhythmias in 30 patients (55 percent). By providing an observation period of at least 24 hours including a period of sleep, the procedure aided detection and diagnosis in both symptomatic and asymptomatic patients of transient arrhythmias or conduction abnormalities not documented by routine electrocardiograms. Bradyarrhythmias accounted for the majority of arrhythmias recorded in 21 or 30 symptomatic patients (70 percent); 15 had sinus bradycardia (35 to 55 beats/min) alone and 6 also had long episodes of sinus arrest of up to 5 seconds. Two had sinus bradycardia with periods of atrioventricular block with Wenckebach phenomenon. Five patients had a tachycardia-bradycardia syndrome; three had other episodic arrhythmias and one had pacemaker failure. In 15 (60 percent) of the 25 patients without arrhythmias, monitoring did not document the cause of symptoms. Holter monitoring is of considerable value in assessing the efficacy and adequacy of drug treatment, especially in patients with known heart disease, and in detecting pacemaker malfunction. However, very long periods of monitoring may be needed to make a diagnosis in those with only sporadic symptoms.

Adult↗

Failure of transesophageal echocardiography to visualize a large mitral prosthesis vegetation detected solely by transthoracic echocardiography.

Transesophageal echocardiography yields a highly accurate diagnosis in the detection of valvular vegetations. We describe a case in which omniplane transesophageal echocardiography failed to demonstrate a large vegetation protruding from a Starr-Edwards mitral prosthesis, toward the left ventricular outflow tract. The vegetation could be detected solely by transthoracic echocardiography.

Echocardiography↗

Right-to-left shunt through a patent foramen ovale caused by severe tricuspid regurgitation detected with color Doppler echocardiography.

We describe a 65-year-old patient with moderate combined mitral disease and severe tricuspid regurgitation, in whom the tricuspid regurgitant jet was oriented toward the interatrial septum. Color flow and pulsed Doppler demonstrated a late-systolic to mid-diastolic, right-to-left shunting of the tricuspid regurgitant jet through the foramen ovale. This finding was subsequently confirmed with transesophageal echocardiography.

Aged↗

Doppler-derived aortic flow measurements during and after heavy isometric exercise in healthy men versus men with myocardial infarction.

Doppler echocardiography is a useful noninvasive determination of left ventricular function during dynamic exercise. Scarce data are available for the use of this technique during heavy isometric exercise. Therefore, Doppler-derived aortic flow indexes were assessed during and after 50% maximal upper-body isometric exercise in 25 healthy men (aged 47 +/- 6 years) and compared with those of 22 men (aged 48 +/- 9 years) who had suffered myocardial infarction. The heart rate increased (p = 0.01) in each of the groups from a mean of 68 +/- 12 at rest to 84 +/- 11 during isometric exercise. At rest, systolic blood pressure was higher (p = 0.05) in the patients with coronary artery disease. During exercise, the patients with cardiac disease, compared with the healthy volunteers, demonstrated a lesser reduction in flow velocity integral, stroke volume, and cardiac indexes (p = 0.001). Immediately on recovery, the patients with cardiac disease, compared with the healthy group, showed significantly greater (p = 0.001) increase in stroke volume and cardiac indexes. At 3 minute's recovery, the stroke volume index continued to increase in the patients with cardiac disease, while the healthy group showed a decrease to below its resting value. Although 50% of maximal upper-body isometric exercise caused similar heart rate and systolic blood pressure responses in healthy patients and patients with cardiac disease, there were significant group differences in Doppler-derived left ventricular systolic function indexes, which were greatest on immediate and 3 minute's recovery. The results suggest that this novel isometric test may be useful in clinical testing.

Aorta↗

Quantitative myocardial ultrasonic integrated backscatter measurements during contrast injections.

We and others have shown that normal myocardium exhibits 4 to 5 dB diastolic-to-systolic cyclic variation (CV) of integrated backscatter. To investigate the effect of intramyocardial contrast on integrated backscatter, we injected 5% sonicated albumin, containing microbubbles in the range of 5 microns in diameter, into the left atrium in nine open-chest dogs. The dogs were anesthetized and placed in the right lateral decubitus position on a specially designed table with a cutout allowing ultrasound imaging from below. Ultrasonic data was obtained from the right precordium by use of a prototype M-mode integrated backscatter system implemented in a commercially available two-dimensional system. Usable data were obtained in eight of nine dogs. Integrated backscatter increased up to 13 dB after contrast injections. There was a significantly decreased CV of integrated backscatter during myocardial contrast in all eight dogs. The mean level of CV of integrated backscatter for the eight dogs decreased from 4.7 dB (530 beats analyzed) without contrast to 2.8 dB during contrast (436 beats analyzed). There was a trend to greater CV at higher levels of contrast. Septal excursion, as measured by M-mode echocardiography simultaneously with integrated backscatter by the same ultrasound beam, was similar with and without contrast (mean 8.2 vs 8.3 mm). Thus left atrium contrast injection produces quantitatively measurable integrated backscatter effects. Cyclic variation of integrated backscatter decreases with contrast. However, at higher contrast levels the decrease tends to be smaller. These effects should be considered during quantitative tissue characterization and myocardial contrast studies.

Albumins↗