Adrenal insufficiency in high-risk surgical ICU patients.

STUDY OBJECTIVES: To examine the incidence and response to treatment of adrenal insufficiency (AI) in high-risk postoperative patients. DESIGN: Prospective observational case series. SETTING: Large urban tertiary-care surgical ICU (SICU). PARTICIPANTS: Adults > 55 years of age who required vasopressor therapy after adequate volume resuscitation in the immediate postoperative period. INTERVENTIONS: Each patient underwent a cosyntropin (ACTH) stimulation test; at the discretion of the clinical team, some patients were empirically given hydrocortisone (100 mg IV q8h for three doses) before serum cortisol values became available. MEASUREMENTS: Adrenal dysfunction (AD), defined as serum cortisol < 20 microg/dL at all time points, with Delta cortisol (60 min post-ACTH minus baseline) of < or = 9 microg/dL; functional hypoadrenalism (FH), defined as serum cortisol < 30 microg/dL at all time points or Delta cortisol (60 min post-ACTH minus baseline) < or = 9 microg/dL; and AI, as the presence of either AD or FH. RESULTS: One hundred four patients were enrolled with a mean age (SD) of 65.2 +/- 16.9 years. AI (AD plus FH) was found in 34 of 104 patients (32.7%): AD was found in 9 patients (8.7%), FH in 25 patients (24%), and normal adrenal function in 70 patients (67.3%). The absolute eosinophil count was significantly higher in the combined AD and FH groups compared with the group with normal adrenal function (p < 0.05). Forty-six of 104 patients (44.2%) received hydrocortisone; 29 (63%) could be weaned from treatment with vasopressors within 24 h. This beneficial effect of hydrocortisone reached statistical significance in the FH group when compared with untreated patients (p < 0.031); a similar trend was seen in the AD group (p = 0.083). Mortality was also lower in the hydrocortisone-treated AI patients (5 of 23 [21%] vs 5 of 11 [45%] in those not receiving hydrocortisone; p < 0.01). CONCLUSION: There is a high incidence of AI among SICU patients > 55 years of age with postoperative hypotension requiring vasopressors. There is also a significant association between hydrocortisone replacement therapy, resolution of vasopressor requirements, and improved survival.

Adrenal Insufficiency↗

Motor Activity Assessment Scale: a valid and reliable sedation scale for use with mechanically ventilated patients in an adult surgical intensive care unit.

OBJECTIVE: To establish the validity and reliability of a new sedation scale, the Motor Activity Assessment Scale (MAAS). DESIGN: Prospective, psychometric evaluation. SETTING: Sixteen-bed surgical intensive care unit (SICU) of a 937-bed tertiary care, university-affiliated teaching hospital. PATIENTS: Twenty-five randomly selected, adult, mechanically ventilated, nonneurosurgical patients who were admitted to the SICU > or = 12 hrs after surgery and were not receiving neuromuscular blockers. INTERVENTION: Four hundred assessments (eight per patient) were completed consecutively but independently, in pairs, at standardized times (both day and night) by two nurses who were preselected for each assessment from a pool of 32 pretrained SICU nurses. MEASUREMENTS AND MAIN RESULTS: To estimate validity, paired assessments (four/patient) compared the MAAS result with the subjective assessment using a 10-cm visual analog sedation scale, the percent change in blood pressure and heart rate from the previous 4-hr baselines, and the number of recent agitation-related sequelae. To estimate reliability, paired assessments (four/patient) measured correlation between assessments of the same type (e.g., MAAS-MAAS). Generalized estimating equations, which accounted for the four repeated measures in each patient, supported MAAS validity by finding a linear trend between MAAS and the visual analog scale (p < .001), blood pressure (p < .001), heart rate (p < .001), and agitation-related sequelae (p < .001) end points. The MAAS (kappa = 0.83 [95% confidence interval, 0.72 to 0.94]) was found to be more reliable than subjective assessment using the visual analog scale (intraclass correlation coefficient = 0.32 [95% confidence interval, 0.05 to 0.55]). CONCLUSIONS: The MAAS is a valid and reliable sedation scale for use with mechanically ventilated patients in the SICU. Further studies are warranted regarding the effect of MAAS implementation in our SICU on patient outcomes, such as quality of sedation and length of mechanical ventilation, as well as the use of the MAAS in other patient populations (e.g., medical).

Adult↗

Determination of gentamicin pharmacokinetics by bioelectrical impedance in critically ill adults.

This investigation compares the accuracy of calculating gentamicin pharmacokinetic parameters by a noninvasive body composition technique (bioelectrical impedance analysis; BIA) with an empiric method, against the two-point method as the criterion standard. A prospective concurrent open label design was used. The 32 medical and surgical intensive care unit beds at Henry Ford Hospital, a not-for-profit, university-affiliated teaching hospital, served as the setting. Twenty critical ill adults, Therapeutic Index Scoring System (TISS) = 4, who required gentamicin as part of their normal course of therapy for gram-negative bacillary infections, were evaluated. Gentamicin Vd and k were calculated by three methods. After measurement of body composition parameters by BIA, previously derived gentamicin dosing equations were used to predict gentamicin volume of distribution (Vd) and elimination rate constant (k) (BIA method). Empiric estimates of these parameters (Vd = 0.3L/kg and k derived from creatinine clearance) were compared with the BIA parameters against a criterion standard Vd and k determined from a two-point sampling of gentamicin serum concentrations. Measurements of BIA parameters and gentamicin serum concentrations were made in duplicate with coefficients of variation, < or = 2% and < or = 3%, respectively. The BIA and empiric methods produced resultant pharmacokinetic parameters (Vd and k) not different than those measured by the two-point method. There were no statistically significant differences in mean error (bias), or mean squared error (precision) for both Vd and k assessed by the empiric or BIA methods.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Bar-code technology applied to drug-use evaluation.

Bar-code technology was used to determine: (1) patterns in histamine H2-receptor antagonist use and (2) the occurrence of adverse drug effects and drug interactions associated with the use of these agents in critically ill patients. Patients at Henry Ford Hospital (Detroit) receiving histamine H2-receptor antagonists over a two-month period were evaluated. Clinical information was collected in the intensive care units by using a bar-code system. The data-capture menu was based on drug-use-evaluation criteria for H2-receptor antagonists. Data collected in the scanning wands were uploaded into a computer database and were analyzed at the end of the study. Data were collected for 207 patients. Cimetidine was the predominant H2-receptor antagonist used, and the predominant indication was stress-ulcer prophylaxis. Dosing trends followed accepted guidelines for cimetidine dosage adjustment in renal and hepatic failure. Two drug interactions and six adverse drug reactions occurred. Pharmacists made 92 recommendations to the medical staff regarding modification in therapy, involving 32% of the patients. Data collection required an average of 10 minutes per day each for three pharmacists. H2-receptor antagonist use patterns were evaluated in intensive care units through the application of bar-code technology. The speed and efficiency of this automated tool facilitated collection of a large amount of data.

Clinical Pharmacy Information Systems↗

Individualizing nutrition in patients with acute respiratory failure requiring mechanical ventilation.

Provision of adequate nutrition is recognized as a therapeutic necessity to maintain inspiratory muscle strength and prevent weaning failures in patients with acute respiratory failure requiring mechanical ventilation. Total caloric needs are empirically estimated by calculation of basal energy expenditure and modified by correction factors for concurrent levels of stress. Energy requirements can vary considerably from empiric estimations and may be better defined by indirect calorimetry that measures oxygen consumption and carbon dioxide production. Protein constituents are initiated empirically until patient-specific urea nitrogen excretion is available. The addition of fat emulsion as 20-50 percent of total daily calories limits lipogenesis, prevents excessive carbon dioxide production, and provides a volume-concentrated caloric source to fluid-restricted patients. Manipulation of nutrient composition can improve or impair ventilatory weaning and nutritional rehabilitation. The significance of substrate utilization is reviewed and recommendations for establishing nutritional regimens for mechanically ventilated adults with acute respiratory failure are provided.

Energy Metabolism↗