Implantation of the automatic defibrillator: the subxiphoid approach.

The automatic implantable defibrillator is an electronic device capable of diagnosing and correcting malignant venticular arrhythmias. While major thoracic surgery was required in the original 24 implants, a new technique for implanting the device has been developed. The first subxiphoid implantations have been accomplished with the defibrillatory function successfully tested intraoperatively. The advantages and indications of the subxiphoid technique are reviewed.

Arrhythmias, Cardiac

The automatic implantable defibrillator. New Modality for treatment of life-threatening ventricular arrhythmias.

The automatic implantable defibrillator continuously monitors cardiac rhythm, identifies ventricular fibrillation and then delivers corrective defibrillatory discharges when indicated; it weighs 250 grams and has a volume of 145 cc. When a suitable arrhythmia is detected, a 25 Joule pulse is delivered through a superior vena cava catheter electrode and another electrode placed over the cardiac apex. As of March 1981, sixteen survivors of multiple cardiac arrests refractory to antiarrhythmic therapy had undergone implantation of the automatic defibrillator. There was no operative mortality and the morbidity was minimal. Electrophysiologic studies were performed before and after surgery to confirm failure of drug therapy and to ensure the device's ability to terminate malignant arrhythmias. Eight spontaneous and fourteen of the seventeen induced malignant arrhythmias were properly recognized and corrected by the device. The discharges were well tolerated by awake patients. A number of problems including recycling delays and spurious discharges have been identified and corrected. There were three late deaths with pulmonary edema noted in two patients, and asystole in one. The autopsies revealed no myocardial damage attributable to the automatic defibrillator. Although the ultimate role of this approach to prevention of sudden arrhythmic death has yet to be determined, the results obtained to date are encouraging and indicate that a useful modality for treating malignant ventricular arrhythmias has been added to our armamentarium.

Adolescent

Automatic defibrillation in man. The initial surgical experience.

The automatic implantable defibrillator is an electronic device designed to detect and promptly correct malignant ventricular arrhythmias. Nineteen patients, all survivors of multiple cardiac arrests because of ventricular arrhythmias unresponsive to therapy, have undergone implantation of the automatic defibrillator. In seven patients who had had a previous cardiac operation, implantation was performed through a left lateral thoracotomy. A median sternotomy was used in five patients without a previous operation. In six patients cardiac procedures were performed concomitantly with defibrillator implantation. There were no operative deaths. The average follow-up is 6 months, the longest being 14 months. Following implantation, 47 episodes of malignant ventricular arrhythmias were documented. Twenty-six occurred spontaneously (17 of them outside the hospital); all were corrected with a single 25 joule pulse. Seventeen of 21 arrhythmias induced postoperatively were terminated. Although further validation is required, this study demonstrates that the automatic defibrillator is capable of diagnosing and terminating potentially lethal ventricular arrhythmias. Finally, implantation can be safely accomplished in an exceedingly high risk population.

Adolescent

The automatic implantable defibrillator.

The automatic implantable defibrillator is an electronic device programmed to monitor the cardiac rhythm continuously, to recognize ventricular fibrillation and ventricular tachyarrhythmias characterized by sinusoidal waveform, and to deliver corrective difibrillatory discharges when indicated. Three patients suffering from recurrent malignant ventricular arrhythmias refractory to medical therapy underwent permanent implantation of this device. Seven episodes of ventricular tachycardia and flutter-fibrillation were documented during the weeks following the implantations; two were induced at electrophysiologic studies and five occurred spontaneously. All were correctly identified and six were automatically reverted to normal sinus rhythm by the implanted device; one induced episode was cardioverted externally before the unit could recycle. Although many problems remain to be solved and the ultimate value of this therapeutic modality has to be determined, a new approach to prevention of sudden death in patients at high risk of developing lethal ventricular arrhythmias has become available.

Adolescent

A chronically implanted system for automatic defibrillation in active conscious dogs. Experimental model for treatment of sudden death from ventricular fibrillation.

Ventricular defibrillation was acheived in active conscious dogs with a chronically implanted automatic system composed of a defibrillator and an alternating current fibrillator. The hermetically sealed defibrillator is encased in titanium, weighs 250 g and has a volume of 145 ml. The sensor continuously monitors ventricular electircal activity and recognizes fibrillation by the absence of isoelectric potential segments. Fibrillation is induced by placing a magnet over the implanted fibrillator. The resulting syncope closely resembles the clinical entity of sudden death, while the defibrillator automatically restores normal rhythm with a truncated exponential pulse of 30 J, 15 seconds after the onset of the arrhythmia. The operational status of the defibrillator can be tested in vitro and noninvasively in vivo with an external analyzer. This experimental model allows for the first time a long-term study of the automatic implantable defibrillator approach to prevent sudden death from ventricular fibrillation under a variety of physiopathologic conditions.

Animals

Treatment of myocardial infarction in a community hospital coronary care unit. Experience with 1,246 patients.

The hospital mortality in 1,246 consecutive acute myocardial infarction patients treated in a large community hospital coronary care unit was 14.4%. Of the total, 52.3% showed no evidence of heart failure, 25.8% had mild to moderate failure, 9.9% had pulmonary edema, and 12% developed cardiogenic shock; the mortality in these groups was 2.2%, 7.4%, 8.9%, and 87.2%, respectively. The mortalitiy in the 1,097 patints who did not have cardiogenic shock was 4.5%. Only one patient died as a result of primary ventricular fibrillation (0.08%). The mortality of complete heart block in the absence of cardiogenic shock (8.3%) was not significantly different from that of comparable patients who did not have complete heart block (4.3%). These results are lower than those generally reported.

Acute Disease

Terminal ECGs.