Search PubMed⌕ Search

Biomedical subjects

M Malik

Publications and source records attributed to M Malik.

At least 91 records · Page 5Linked to original sources

Agreement and reproducibility of automatic versus manual measurement of QT interval and QT dispersion.

To determine whether the automatic measurement of the QT interval is consistent with the manual measurement, this study evaluated the reproducibility and agreement of both methods in 70 normal subjects and 54 patients with hypertrophic cardiomyopathy. The mean, minimum, and maximum QT interval and QT dispersion were computed in a set of 6 consecutive electrocardiograms (3 in the supine and 3 in the standing position) obtained from each subject. The automatic method determined the T-wave end as the intersect of the least-squares-fit line around the tangent to the T-wave downslope with the isoelectric baseline. Manual measurements were obtained using a high-resolution digitizing board. QT dispersion was defined as the difference between the maximum and minimum QT interval and as standard deviations of the QT interval duration in all and precordial leads. In patients with hypertrophic cardiomyopathy, the absolute values of the QT interval and QT dispersion were significantly higher than those in normal subjects (p < 0.0001). In both groups, the intrasubject variability of the QT interval was significantly lower with automatic than with manual measurement (p < 0.05). The agreement between automatic and manual QT interval measurements was surprisingly poor, but it was better in patients with hypertrophic cardiomyopathy (r2 = 0.46 to 0.67) than in normal subjects (r2 = 0.10 to 0.25). In both groups, the reproducibility and agreement of both methods for QT dispersion were significantly poorer than for QT interval. Hence, the automatic QT interval measurements are more stable and reproducible than manual measurement, but the lack of agreement between manual and automatic measurement suggests that clinical experience gained with manual assessment cannot be applied blindly to data obtained from the automatic systems.

Adolescent↗

Optimum lead positioning for recording bipolar atrial electrocardiograms during sinus rhythm and atrial fibrillation.

BACKGROUND: To date, Holter monitoring has been predominantly utilized in the investigation and monitoring of ventricular arrhythmias and myocardial ischemia. Whether currently employed lead configurations are optimal for recording atrial electrocardiograms (ECGs) is unknown. HYPOTHESIS: This study was undertaken to determine which conventional and novel lead configurations are optimal for recording atrial electrical activity during sinus rhythm and atrial fibrillation. METHODS: Recordings were performed on eight healthy volunteers in sinus rhythm and four patients in atrial fibrillation. Each subject had 10 ECGs of three bipolar and three augmented unipolar leads recorded during supine rest, while rising to upright, and during standing rest, yielding a total of 60 leads (30 bipolar leads). Each tracing was inspected by two observers, and parameters such as P-wave amplitude and duration, whether the P-wave onset was clearly seen, atrial fibrillatory-wave amplitude, and amplitude of noise during standing were scored. RESULTS: Leads recording inferiorly and leftward orientated bipoles provided the best registration of sinus P waves. The P-wave amplitude in the standard bipolar C5 lead (0.12 +/- 0.02 mV) was, however, inferior to others such as recordings between C1 and C6 positions (P-wave amplitude 0.16 +/- 0.02 mV) or from below the right clavicle to the left upper quadrant of the abdomen (0.16 +/- 0.01 mV). Optimal recording of fibrillatory waves was from different leads, such as a bipole from below the left clavicle to a low C1 position (fibrillatory wave amplitude 0.27 +/- 0.03 mV). CONCLUSION: When Holter recordings are performed for the investigation of atrial arrhythmias, nonstandard lead configurations provide superior recording of atrial electrical activity. We advocate the use of electrodes positioned from C1 to C6, from below the left clavicle to a low C1 position, and a vertically orientated lead from the manubium to the twelfth vertebra or the xiphisternum.

Adult↗

Analysis of the cardiac rhythm preceding episodes of paroxysmal atrial fibrillation.

AIMS: This study seeks to elucidate whether there was a common mode of initiation of paroxysmal atrial fibrillation (PAF) episodes that might suggest new therapies. METHODS: A library of 177 digitized and analyzed 24-hour Holter recordings from PAF pharmacotherapy trials was studied. All noise-free PAF episodes > or =0.5 minutes were identified. PAF episodes and the preceding 2 minutes of sinus rhythm were printed as tachograms and visually inspected. Heart rate and ectopic beat behavior were used to characterize modes of PAF onset by comparing half-minute segments of the final 2 minutes of sinus rhythm. RESULTS: Thirty-four recordings (from 19 patients, aged 61.7 +/- 11.5 years) provided 231 PAF episodes suitable for analysis. No patients had a consistent mode of PAF onset. This was confirmed by systematic analysis of the five patients with the most episodes. Overall, a highly significant increase in ectopic beats, from 1.34 to 6.52 min(-1) (p < 0.001) was found, but heart rate did not significantly change (mean heart rate at onset = 64 beats/min). PAF was initiated by a solitary ectopic beat in more than half of the cases. No consistent evidence for short-long-short sequences, seen in ventricular arrhythmias, was found. CONCLUSION: The mode of onset of atrial fibrillation is inconsistent, both across a population with PAF and within individuals. This has implications for understanding the mechanisms of atrial fibrillation onset in human beings and for the treatment of the disorder.

Atrial Fibrillation↗

Arabian Peninsula men tend to insulin resistance and cardiovascular risk seen in South Asians.

OBJECTIVE: To test the hypothesis that peninsular Arabs and South Asians share a tendency to insulin resistance, differing from other ethnic groups living in the United Arab Emirates (UAE). METHODS: A representative sample of 358 apparently healthy men aged 35-49 years drawn from a multiethnic office-based workforce in the UAE was tested. The sample included a reference group of expatriate South Asians, in whom insulin resistance has already been described as the cause of high coronary heart disease (CHD) mortality. All subjects were screened for CHD risk factors, including glucose tolerance and 2-h serum insulin determinations. RESULTS: There was a high prevalence of previously undiagnosed cases of diabetes (10.1%) and hypertension (14.2%). South Asian and peninsular Arab men shared the tendency to significantly higher 2-h glucose and insulin levels, lower HDL cholesterol concentrations and abdominal obesity especially compared to Europeans, who were five times less likely to be glucose-intolerant (OR 5.40, P = 0.015). Three other Arab groups were intermediate in most trends. CONCLUSION: Susceptibility to insulin resistance in Arabian peninsula men is strongly supported, suggesting that control of obesity and promotion of exercise are the best approach to CHD prevention.

Adult↗

Identification of post acute myocardial infarction patients with potential benefit from prophylactic treatment with amiodarone. A substudy of EMIAT (the European Myocardial Infarct Amiodarone Trial).

AIMS: To perform a retrospective analysis of subgroups of patients enrolled into the European Myocardial Infarct Amiodarone Trial (EMIAT) in order to identify patients who might benefit from prophylactic amiodarone treatment and patients in whom amiodarone might be harmful. METHODS: Baseline characteristics of the 1486 patients enrolled in EMIAT were used to investigate the all-cause mortality effect of amiodarone (intention-to-treat) in patients with a left ventricular ejection fraction 30-40% and < 30%, in patients with and without arrhythmia signs on Holter recordings, in patients with high and low baseline resting heart rate, in patients on and off beta-blocker treatment, and in a combination of these groups. RESULTS: A univariate analysis suggested that all-cause mortality is reduced on amiodarone in patients with an ejection fraction < 30%, with arrhythmia on the initial Holter, on beta-blocker treatment, and with an increased initial heart rate. A trend towards an increase of all-cause mortality was noted in patients with an ejection fraction 30-40%, without arrhythmia on Holter, off beta-blockers, and with a low baseline heart rate. A multivariate analysis suggested that the univariate observations are mutually additive. CONCLUSIONS: The study might serve as a basis for future prospective trials where amiodarone could be tested in patients with a recent myocardial infarction, having a reduced left ventricular ejection fraction, a high initial heart rate, and taking beta-blockers.

Adrenergic beta-Antagonists↗

Wavelet decomposition analysis of the signal averaged electrocardiogram used for risk stratification of patients with hypertrophic cardiomyopathy.

AIMS: To study the predictive value of wavelet decomposition, as demonstrated by the signal-averaged ECG, in order to identify patients with hypertrophic cardiomyopathy at increased risk for malignant ventricular arrhythmias or sudden death. METHODS AND RESULTS: Two hundred and forty-six patients with hypertrophic cardiomyopathy were studied. During a mean follow-up of 68 +/- 17 months 32 patients died, of whom 17 died suddenly. Patients with sudden death, together with eight patients with a history of ventricular fibrillation (sudden death/ventricular fibrillation group) were analysed and compared to the other 221 patients as well as to a subgroup of 82 patients without a history of syncope, ventricular arrhythmias on a long-term ECG recording or a family history of sudden death. There were no differences in mean values of the four wavelet decomposition parameters among patients in the sudden death/ ventricular fibrillation group, those without sudden death/ ventricular fibrillation or patients in the low risk group. There were, however, significant differences between patients dying non-suddenly and patients being alive at the end of follow-up. Eighty-seven patients (35%) demonstrated evidence of non-sustained ventricular tachycardia on a long-term ECG. Analysis of wavelet decomposition resulted in abnormal findings in these patients more often than in those without ventricular arrhythmias. CONCLUSION: The usefulness of wavelet decomposition analysis in predicting sudden death or ventricular fibrillation is limited in patients with hypertrophic cardiomyopathy. It may, however, play a role in identifying patients at risk of dying non-suddenly and of patients with non-sustained ventricular tachycardia.

Adolescent↗

The prognostic value of the QT interval and QT interval dispersion in all-cause and cardiac mortality and morbidity in a population of Danish citizens.

AIMS: To evaluate the prognostic value of the QT interval and QT interval dispersion in total and in cardiovascular mortality, as well as in cardiac morbidity, in a general population. METHODS AND RESULTS: The QT interval was measured in all leads from a standard 12-lead ECG in a random sample of 1658 women and 1797 men aged 30-60 years. QT interval dispersion was calculated from the maximal difference between QT intervals in any two leads. All cause mortality over 13 years, and cardiovascular mortality as well as cardiac morbidity over 11 years, were the main outcome parameters. Subjects with a prolonged QT interval (430 ms or more) or prolonged QT interval dispersion (80 ms or more) were at higher risk of cardiovascular death and cardiac morbidity than subjects whose QT interval was less than 360 ms, or whose QT interval dispersion was less than 30 ms. Cardiovascular death relative risk ratios, adjusted for age, gender, myocardial infarct, angina pectoris, diabetes mellitus, arterial hypertension, smoking habits, serum cholesterol level, and heart rate were 2.9 for the QT interval (95% confidence interval 1.1-7.8) and 4.4 for QT interval dispersion (95% confidence interval 1.0-19-1). Fatal and non-fatal cardiac morbidity relative risk ratios were similar, at 2.7 (95% confidence interval 1.4-5.5) for the QT interval and 2.2 (95% confidence interval 1.1-4.0) for QT interval dispersion. CONCLUSION: Prolongation of the QT interval and QT interval dispersion independently affected the prognosis of cardiovascular mortality and cardiac fatal and non-fatal morbidity in a general population over 11 years.

Adult↗

Heart rate variability index in congestive heart failure: relation to clinical variables and prognosis.

AIM: To evaluate the clinical and prognostic value of the heart rate variability index in patients with congestive heart failure. METHODS: Sixty-four patients with chronic congestive heart failure and sinus rhythm underwent clinical assessment, 24-h ambulatory electrocardiography and echocardiography. Patients were followed for 6 to 30 months. Cardiac death or heart transplantation constituted the primary end-point of the study. RESULTS: The heart rate variability index was related to left ventricular ejection fraction (r=0.29, P=0.02) and New York Heart Association class (P=0.01). Patients with a restrictive left ventricular filling pattern had a lower heart rate variability index compared to patients with a non-restrictive pattern (26+/-11 vs 33+/-9 units, P=0.01). Patients who died (n=11) or underwent heart transplantation (n=4) had a lower heart rate variability index compared to survivors (21+/-10 vs 33+/-9 units, P<0.0001). In multivariate survival analysis, a reduced heart rate variability index was related to survival independent of parameters of left ventricular function. CONCLUSION: The heart rate variability index provides independent information on clinical status and prognosis in patients with chronic congestive heart failure.

Aged↗

Heart rate variability.

Heart rate variability is a recognized tool for the estimation of cardiac autonomic modulations. Recently, several studies have advanced the field of heart rate variability in three areas: 1) in technical modes of electrocardiogram processing and heart rate variability assessment, 2) in physiologic understanding and interpretation, and 3) in clinical and practical use. The most recent technical studies concentrate on the analysis of nonlinear aspects of heart period variations and on coherence between electrocardiogram variability and other physiologic factors such as respiration. Principal physiologic investigations studied the components of heart rate variability attributable to the individual limbs of the autonomic nervous system. It is becoming recognized that behavior and responses to the environment, including the psychosocial environment, play an important role in long-term heart rate variability. Established clinical applications of heart rate variability are presently restricted to the assessment of risk after myocardial infarction and to the early diagnosis of diabetic neuropathy. Nevertheless, recent studies indicate that heart rate variability might soon become a similarly powerful tool for risk prediction and monitoring of disease progression in congestive heart failure and for monitoring or reinnervation after heart transplantation.

Autonomic Nervous System↗

Stepwise strategy on the cost of risk stratification after acute myocardial infarction: a retrospective simulation study.

Stratification of postinfarction patients at high risk of mortality and/or other adverse events can be improved by combining several prognostic markers. As the clinical impact of risk stratification has only recently emerged in prospective trials, there are a lack of data regarding the cost-effectiveness of multimarker strategies. This study performed a comprehensive search of a postinfarction database and simulated different risk stratification strategies involving left ventricular ejection fraction, signal-averaged electrocardiography, Holter monitoring, and heart rate variability, The parameters were assessed before discharge in 417 survivors of acute myocardial infarction followed-up for 1 year. Cardiac mortality was used as the clinical endpoint. A statistical computer model of a stepwise strategy using every feasible sequence of the four tests was used and, based on prices derived from European and American centers, the cost estimates of all possible combinations were compared. During the 1 year after myocardial infarction there were 24 cardiac deaths (5.8%). In all the population, 6% had all four tests positive (cardiac mortality 20%); 25% had at least three tests positive (cardiac mortality 12.5%); 58% had at least two tests positive (cardiac mortality 8.3%); and 92% presented with at least one test positive (cardiac mortality 6.3%). The cost of performing all the tests ranged between $398 and $1,887 for each patient. However, by selecting patients according to a step wise strategy, the costs ranged from $96 (> or = 1 test positive) to $510 (for the least expensive sequences of four tests positive). For each of the centers considered, the costs resulting from the risk stratification protocol were determined by the number of variables combined and sequences of tests adopted. Thus, a step wise strategy using the combination of all four parameters, starting with analysis of Holter variables and finishing with signal-averaged electrocardiography, appears to be the most appropriate and the least expensive approach for selecting patients at high risk of cardiac death.

Computer Simulation↗

Human precision of operating a digitizing board: implications for electrocardiogram measurements.

To investigate the precision achieved by human measurement on a digitizing board, 100 healthy volunteers (46 women, mean age 36 +/- 12 years) were asked to measure 15 times on artificial pattern composed of 15 points. A high precision digitizing board (programmed to the technical accuracy of +/- 50 microns) was used, and mean and maximum errors in measuring the same distance repeatedly and relocalizing the same point repeatedly were obtained for each volunteer. A median mean and maximum error of 0.2 mm and 1.0 mm were found for repeated distance measurement. When simulating QT dispersion measurement (measuring the same distance 12 times), median value of 20 ms was obtained for ECGs of 25 mm/s paper speed. The study concludes that human precision of operating a digitizing board is rather poor. A recommendation is given to use either a computer screen for manual measurement of ECGs or to provide an operator of the digitizing board with an immediate feedback of the precision and measurement stability achieved so that erroneous measurement can be actively rejected.

Adolescent↗

Mid- and long-term similarity of ventricular response to paroxysmal atrial fibrillation: digoxin versus placebo.

The effects of digoxin on ventricular response during atrial fibrillation (AF) and consequent effects on arrhythmic symptoms have still not been fully explained. This study investigated whether the treatment by digoxin contributes to mid- and long-term stabilization of ventricular cycles in patients with paroxysmal AF. A population of 45 patients with paroxysmal AF underwent 24-hour ECG recordings during each arm of a randomized crossover trial comparing digoxin and placebo. This yielded 30 Holter recordings from 22 patients that contained AF episodes lasting in excess of 2 minutes and with acceptably low Holter noise. Each AF episode was divided into nonoverlapping segments of 30 seconds and the distribution of RR intervals in each segment was compared with the distribution of all other AF segments in the same recording using the Kolmogorov-Smirnov test. The percentage of tests that revealed significant differences at levels of P < or = 0.01, and P < or = 0.001 were sorted according to the time between the segments compared. The comparisons of these results were performed between: (a) all recordings on placebo (n = 16) and all recordings on digoxin (n = 14), and (b) between recordings on placebo and on digoxin in 8 patients in whom paired analysis was possible. Adjacent AF segments (distance 0) differed significantly only in < 30% of both recordings on placebo and on digoxin. However, with increasing the distance between segments, the proportion of the significant differences between RR interval distributions increased more with placebo than with digoxin (P < 10(-300), Chi-square test). Paired data revealed larger differences between placebo and digoxin with increasing distance between segments. Thus in patients with paroxysmal AF, digoxin leads to more reproducible patterns of ventricular cycles that may be better tolerated clinically.

Adult↗

A relationship between fluctuations in heart rate and the duration of subsequent episodes of atrial fibrillation.

A relationship between autonomic tone and the onset of paroxysmal atrial fibrillation in some patients is recognised. Episodes of PAF may vary enormously in duration, however, from a few beats to many hours. Whether autonomic tone influences the duration of the episodes has been less well investigated. From a database of Holter recording taken from patients with symptomatic PAF, we identified all episodes of at least 30 seconds duration which were preceded by noise free sinus rhythm. This study examined the heart rate prior to AF onset, the change in heart rate over the final minute of sinus rhythm and the time of AF onset, and compared the data from those episodes of AF of more than 5 minutes duration to the shorter ones. Heart rate was slower before long episodes of AF, but this was found to predominantly represent data from separate recordings. A highly significant rise in heart rate was detected prior to long AF episodes compared to shorter ones. Daytime AF episodes were slightly longer than nocturnal ones. The most important finding was that longer AF episodes were typified by a heart rate acceleration. This suggests that, regardless of underlying aetiology, and increase in sympathetic tone may be important in the sustenance of episodes of PAF.

Anti-Arrhythmia Agents↗

Multiparametric analysis of heart rate variability used for risk stratification among survivors of acute myocardial infarction.

A multiparametric heart rate variability analysis was performed to prove if combined heart rate variability (HRV) measures of different domains improve the result of risk stratification in patients after myocardial infarction. In this study, standard time domain, frequency domain and non-linear dynamics measures of HRV assessment were applied to 572 survivors of acute myocardial infarction. Three parameter sets each consisting of 4 parameters were applied and compared with the standard measurement of global heart rate variability HRVi. Discriminant analysis technique and t-test were performed to separate the high risk groups from the survivors. The predictive value of this approach was evaluated with receiver operator (ROC) and positive predictive accuracy (PPA) curves. Results--The discriminant analysis shows a separation of patients suffered by all cause mortality in 80% (best single parameter 74%) and sudden arrhythmic death in 86% (73%). All parameters of set 1 show a high significant difference (p < 0.001) between survivors and non-survivors based on two-tailed t-test. The specificity level of the multivariate parameter sets is at the 70% sensitivity level (ROC) about 85-90%, whereas HRVi shows maximum levels of 70%. The PPA in the all cause mortality group is at the 70% sensitivity level twice as high as the univariate HRV measure and increases to more than fourfold as high within the VT/VF group. In conclusion, in this population, the multiparametric approach with the combination of four parameters from all domains especially from NLD seems to be a better predictor of high arrhythmia risk than the standard measurement of global heart rate variability.

Arrhythmias, Cardiac↗

QT interval and QT dispersion measured with the threshold method depend on threshold level.

Various computerized methods with multiple parameter options for measurements of the QT interval now are available. The optimum parameter setting for most algorithms is not known. This study evaluated the influence of the threshold level applied on the T wave differential on the QT interval and its dispersion measured in normal and abnormal electrocardiograms (ECGs). Seven hundred sixty ECGs recorded in 76 normal subjects and 630 in 63 patients with hypertrophic cardiomyopathy (HCM) (10 consecutive recordings in each individual) were analyzed. In each lead of each ECG, the QT interval was measured by the threshold method applied to the first differential of the T wave. The threshold level was varied between 5% and 30% of the T wave maximum in 1% steps, resulting in 26 different choices of QT measurements. With each choice the maximum QTc and the QT dispersion (QTd, standard deviation of the QT in all 12 leads) were obtained for each recording. The maximum QTc was significantly longer in HCM patients than in normal subjects (P < 0.001) at all threshold levels except between 5% and 7%. The QTd was significantly greater in HCM patients at all threshold levels. The QTc and QTd changed significantly with the threshold level. The maximum QTc varied up to 60 ms in normal subjects and up to 70 ms in HCM patients, depending on the threshold level. Thus, the QT interval and its dispersion measured with the threshold method applied to the first T wave differential depended significantly on the threshold level in both normal and diseased hearts. All programmable options of available automatic instruments should be examined carefully before any study, and all algorithmic details should by systematically presented.

Adult↗

Comparative reproducibility of QT, QT peak, and T peak-T end intervals and dispersion in normal subjects, patients with myocardial infarction, and patients with hypertrophic cardiomyopathy.

Abnormal repolarization is associated with arrhythmogenesis. Because of controversies in existing methodology, new computerized methods may provide more reliable tools for the noninvasive assessment of myocardial repolarization from the surface electrocardiogram (ECG). Measurement of the interval between the peak and the end of the T wave (TpTe interval) has been suggested for the detection of repolarization abnormalities, but its clinical value has not been fully studied. The intrasubject reproducibility and reliability of automatic measurements of QT, QT peak, and TpTe interval and dispersion were assessed in 70 normal subjects, 49 patients with acute myocardial infarction (5th day; MI), and 37 patients with hypertrophic cardiomyopathy (HC). Measurements were performed automatically in a set of 10 ECGs obtained from each subject using a commercial software package (Marquette Medical Systems, Milwaukee, WI, U.S.A.). Compared to normal subjects, all intervals were significantly longer in HC patients (P < 0.001 for QT and QTp; p < 0.05 for TpTe); in MI patients, this difference was only significant for the maximum QT and QTp intervals (P < 0.05). In both patient groups, the QT and QTp dispersion was significantly greater compared to normal subjects (P < 0.05) but no consistent difference was observed in the TpTe dispersion among all three groups. In all subjects, the reproducibility of automatic measurement of QT and QTp intervals was high (coefficient of variation, CV, 1%-2%) and slightly lower for that of TpTe interval (2%-5%; p < 0.05). The reproducibility of QT, QTp, and TpTe dispersion was lower (12%-24%, 18%-28%, 16%-23% in normal subjects, MI and HC patients, respectively). The reliability of automatic measurement of QT, QTp, and TpTe intervals is high but the reproducibility of the repeated measurements of QT, QTp and TpTe dispersion is comparatively low.

Adult↗

T wave complexity in patients with hypertrophic cardiomyopathy.

The complexity of the T wave assessed by principal component analysis (PCA) has been proposed to reflect abnormal repolarization, which may be arrhythmogenic. To determine whether PCA can differentiate patients with hypertrophic cardiomyopathy (HCM) from normal subjects and whether PCA is of prognostic importance in HCM, 112 patients with HCM (41 +/- 14 years, 64 males) and 72 healthy subjects (39 +/- 9 years, 41 males) were studied. Patients with sinus node dysfunction, AV conduction block, flat T waves, QRS > 140 ms, and those < 15 years were excluded from this study. Standard 12-lead ECGs were recorded digitally using the MAC-VU system (Marquette Medical Systems). PCA parameters were computed using the QT Guard software package by Marquette. PCA ratio was significantly greater in HCM patients than in normal controls (23.9% +/- 12.4% vs 16.1% +/- 7.6%, P < 0.0001) and was correlated with QT-end dispersion (r = 0.24, P = 0.01) and QT peak (Q point to T peak) dispersion (r = 0.35, P < 0.0001). HCM patients with syncope (n = 23) had increased PCA ratios compared with those without syncope (29.1% +/- 11.5% vs 22.5% +/- 12.3%, P = 0.01). PCA ratio was similar in patients with and without nonsustained ventricular tachycardia on Holter (25.9% +/- 11.4% vs 22.7% +/- 12.1%, P = 0.2), as well as in patients treated with amiodarone or sotalol versus those not on therapy. In conclusion, assessment of the complexity of the T wave by PCA differentiates HCM patients from normal subjects. PCA ratio correlated with QT dispersion and an increased PCA ratio was associated with a history of syncope in HCM.

Adult↗