Automatic implantable cardioverter defibrillator: surgical approaches for implantation.

Surgical approaches for implantation of the automatic cardioverter defibrillator are sternotomy, left thoracotomy, subxiphoid, and subcostal. Although any one of these may be combined with insertion of one or more of the electrodes transvenously, surgical entry into the chest is required for every noninvestigational defibrillator implantation operation. The approaches differ in exposure provided for selecting electrode sites and for handling untoward events, in amount and location of tissue that must be divided or dissected, and in average time required. The operation is an electrical one. Its purpose is to obtain reliable rhythm sensing so that defibrillation or cardioversion shocks will occur only when necessary, and to obtain low enough defibrillation thresholds for shocks of 30 joules or less to have a 10-joule defibrillation safety margin. Many of the patients have had previous cardiac operations. They usually have low or very low ejection fractions. Intraoperative electrophysiological testing with often multiple defibrillation episodes is required. The choice of approach varies with the state of the patient, the institutional experience, and the surgeon. This article describes technique, and the advantages and disadvantages of the four approaches as used by four surgeons in four different institutions.

Defibrillators, Implantable↗

Effects of pacing rate and timing of defibrillation shock on the relation between the defibrillation threshold and the upper limit of vulnerability in open chest dogs.

To test the relation between the defibrillation threshold and the upper limit of vulnerability, the shock strength associated with 50% probability of successful defibrillation (DFT50) and that associated with 50% probability of reaching the upper limit of vulnerability (ULV50) were determined in 20 open chest dogs with use of the delayed up-down method, with pacing drive cycle lengths of 150 to 500 ms and either single 6-ms shocks (10 dogs) or 12-ms biphasic shocks (10 dogs) given at the mid-upslope, peak and mid-downslope of the T wave of electrocardiographic lead II. The shocks were given by means of a patch-patch configuration on the anterior and posterior surfaces of the heart, which was paced from a stimulating electrode attached to the left ventricular apex. Analysis of variance showed no statistically significant differences in ULV50 as determined with different pacing cycle lengths. For monophasic shocks, DFT50 (331 +/- 66 V or 5.8 +/- 2.7 J) was not significantly different from ULV50 determined at the mid-upslope of the T wave (318 +/- 64 V or 5 +/- 2 J). The correlation coefficients between the two values were 0.74 (p = 0.014) for voltage and 0.67 (p = 0.034) for energy. In contrast, DFT50 was significantly higher than ULV50 as determined at the peak of the T wave (219 +/- 43 V or 2.3 +/- 1 J) and mid-downslope of the T wave (200 +/- 38 V or 1.9 +/- 0.9 J). In three dogs, ventricular fibrillation could not be induced at the mid-downslope of the T wave with any baseline pacing (Si) cycle length.(ABSTRACT TRUNCATED AT 250 WORDS)

Analysis of Variance↗

Clinical efficacy of low energy cardioversion in automatic implantable cardioverter defibrillator patients.

The inclusion of low energy cardioversion capability into modern implantable antiarrhythmic devices, although an appealing idea, is nevertheless unproven with regard to its potential benefits. Moreover, since occasional reports have surfaced suggesting that ineffective application of low energy shocks may prejudice subsequent arrhythmia reversion, we examined the effectiveness and risks of this feature in a large series of patients performed as part of a US Food and Drug Administration clinical trial performed under an investigational device exemption. A total of 813 induced monomorphic ventricular tachycardias were studied in 244 patients. We found that many of the arrhythmias could be reverted to sinus rhythm with small amounts of energy. Cardioversion energy was less than or equal to 6 joules (J) for 84 (53.2%) and less than or equal to 14 joules in 105 (66.4%) of the 158 patients tested at implant and subsequently remained unchanged through greater than 4 months follow up. The incidence of noncardioversion, acceleration or both occurred in 12.7%, 5.7%, and 13.1%, respectively on a per patient basis. On a per episode basis, nonconversion occurred in 51 (6.3%) and acceleration in 61 (7.5%) of the 813 inductions. There was no correlation between the occurrence of nonconversions and accelerations. The devices were allowed to recycle in the event the arrhythmia was not reverted. The subsequent shock was almost always effective, and in any event, no patient failed to be reverted by the second 30-J rescue shock. Over the entire follow-up period as long as 17 months, there were 17 deaths. Neither the incidence nor the mode of death was correlated with nonconversion or acceleration.(ABSTRACT TRUNCATED AT 250 WORDS)

Electric Countershock↗

Hemodynamic responses to rapid pacing: a model for tachycardia differentiation.

The hemodynamic responses to rapid atrial and ventricular pacing were examined in 10 closed-chest anesthetized dogs in an attempt to distinguish hemodynamically stable from unstable tachycardias. Pressure monitoring catheters were placed in the femoral artery, right atrium, and right ventricle to measure mean arterial pressure, mean right atrial pressure, and mean right ventricular pressure at baseline heart rate and after rapid high right atrial and right ventricular apex pacing. Pressures recorded during rapid pacing (average of the pressures at 30 and 60 seconds of pacing) at pacing rates of 180, 250, and 280/minute were compared to those recorded initially at baseline heart rates. Rapid right ventricular apex pacing resulted in significant increases in mean right atrial pressure (from 6 +/- 1 mmHg (mean +/- standard error) to 12 +/- 1 mmHg, a 100% increase, P less than 0.001) and mean right ventricular pressure (from 11 +/- 1 mmHg to 16 +/- 1 mmHg, a 45% increase, p less than 0.02) with marked hemodynamic compromise (mean arterial pressure decreased from 85 +/- 6 mmHg to 50 +/- 6 mmHg, a 41% decrease, P less than 0.01). These parameters remained stable (no statistically significant difference from baseline) during high right atrial pacing. In half of the dogs high right atrial pacing at rates greater than or equal to 250 resulted in atrioventricular Wenckebach. Thus, it is concluded that mean right atrial pressure and mean right ventricular pressure may be useful in distinguishing hemodynamically significant tachycardias, and in the future design of antitachycardia devices.

Animals↗

AICD indications (patient selection): past, present and future.

During the course of a seven year implant experience with the Automatic Implantable Cardioverter-Defibrillator (AICD) now extending to well over 3,700 implantees, several functional advances have been made in the pulse generators, and criteria for implantation were successively broadened. Survival statistics have been excellent with 1-year arrhythmic survival over 98%, and total survival from all causes of death in excess of 60% at 5 years. Still, only relatively few of the patients who could possibly be helped by this device actually receive one. Reasons for this are probably complex but include, among other things, the relative newness of electrophysiology as a subspecialty, and a lack of appreciation by the general medical public in regard to this particular treatment modality. Small increases in referral patterns thus can have the potential to produce marked increases in the utilization of AICDs. Additionally, other high risk populations appear to be ready for inclusion into AICD therapeutic trials, and techniques also appear at hand to examine presumably healthy populations so as to predict those subject to suffer eventual sudden cardiac arrest. Under such circumstances, the ultimate impact of AICD therapy can hardly be imagined.

Arrhythmias, Cardiac↗

Success of chronic defibrillation and the role of antiarrhythmic drugs with the automatic implantable cardioverter/defibrillator.

Because the automatic internal cardioverter defibrillator's long-term ability to reduce arrhythmic mortality in patients with ventricular tachycardia/fibrillation is unknown, it is important to determine whether the threshold for defibrillation changes over time. Serial defibrillation thresholds were measured in 23 patients over a mean replacement time of 24.8 +/- 7.5 months. In all cases the lead system was a superior vena cava coil to a left ventricular epicardial patch. The defibrillation threshold for the entire group increased from 12.3 +/- 4.7 J to 16.9 +/- 5.9 J (p less than 0.05). Striking increases in the defibrillation threshold were seen in the subgroup of patients taking amiodarone (from 10.9 +/- 4.3 J at implantation to 20.0 +/- 4.7 J at replacement, p less than 0.05). Defibrillation threshold decreased in patients taking no antiarrhythmic drugs or taking class I agents. Thus, the increase in mean defibrillation threshold was the result of an increase in the patients taking amiodarone. These data suggest that at initial implantation lead systems associated with the lowest defibrillation threshold should be used and the defibrillation threshold should be measured at generator change to guarantee an adequate margin of safety.

Aged↗

Sudden cardiac death from acute fluoride intoxication: the role of potassium.

The mechanism of sudden cardiac death following acute fluoride intoxication has been thought to result from profound hypocalcemia produced by the precipitation of calcium fluoride salts. In studies of a canine model, the onset of lethal ventricular arrhythmias was temporally more associated with an elevation of serum potassium than with a drop in serum calcium. Fluoride-induced hyperkalemia could not be prevented with glucose, insulin, or bicarbonate. In the erythrocytes, a five-minute exposure to 10 mM NaF caused a 50% increase in extracellular potassium concentrations after 12 hours compared to control erythrocyte suspensions (P less than .001). The total potassium efflux after 12 hours of incubation was linearly related to the log of fluoride contact time (r, 0.886; P less than .001). The treatment of fluoride-induced hyperkalemia may depend on removal of fluoride and potassium.

Animals↗

Pathologic findings related to the lead system and repeated defibrillations in patients with the automatic implantable cardioverter-defibrillator.

The purpose of the present study was to examine at autopsy the effect of multiple defibrillations on the myocardium and the pathologic consequences of short- and long-term placement of the intravascular and interpericardial leads of the automatic implantable cardioverter-defibrillator. Twenty-five patients were examined at autopsy; 8 of them underwent lead implantation only and 17 received both leads and the automatic implantable cardioverter-defibrillator. Twelve patients (48%) died of ventricular tachycardia or ventricular fibrillation; seven (28%) died of other causes. Acute pericarditis occurred in all patients, resulting in a localized, progressive fibrosis around the apical patch lead without giving rise to pericardial restriction. Thrombus formation was associated with the superior vena cava spring electrode in four patients (17%) and the right ventricular rate-sensing electrode in one patient (4%). Asymptomatic pulmonary emboli occurred in two patients (8%). In one patient who underwent defibrillation 59 times, superior vena cava changes consisted of vein wall destruction, fibrosis and thrombus formation. Pathologic changes under the apical patch related to defibrillation were observed in seven patients; two of these had fewer than 5 defibrillations, one had 8 defibrillations and four had 21 to 74 defibrillations. These changes consisted of contraction band necrosis in four patients, vacuolar cytoplasmic clearing and loss of myocytes confined to the myocardium under the patch electrode in five patients who had multiple defibrillations. The observed pathologic changes were estimated to affect less than 2% of the total myocardial mass. Thus, the automatic implantable cardioverter-defibrillator lead system and multiple defibrillations result in localized myocardial injury confined to the tissue under the patch electrode.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Echocardiogram of pulmonary embolism in evolution.

Echocardiography during active pulmonary embolism can reveal the embolic mass in transit through the chambers of the right side of the heart. The pattern produced is that of multiple masses of varying sizes, shapes, and densities moving from the right atrium to the right ventricle. It was not present on repeated echocardiogram performed several weeks later, after anticoagulation treatment. Proper recognition of this pattern can lead to prompt medical treatment with anticoagulants, which, in this case, led to a quite satisfactory clinical outcome.

Echocardiography↗

Treatment of malignant ventricular arrhythmias with endocardial resection and implantation of the automatic cardioverter-defibrillator.

Although ventricular resection guided by endocardial mapping has been a successful treatment for drug-refractory ventricular arrhythmias, 20 to 30 percent of patients still have postoperative sustained ventricular tachycardia or sudden death. To improve the outcome of the procedure, we implanted an automatic cardioverter-defibrillator in conjunction with endocardial resection in 28 patients, all of whom had had previous myocardial infarctions and between one and five cardiac arrests. There were three perioperative deaths. During follow-up of 8 to 51 months (mean, 25), 4 of the 25 survivors had recurrences of hypotensive ventricular tachycardia, which in all instances were automatically terminated by the implanted device. One patient, whose automatic cardioverter-defibrillator was not functional, died suddenly. We conclude that patients undergoing mapping-directed endocardial resection can be provided with additional protection against recurrent ventricular tachyarrhythmias or sudden death by implantation of an automatic cardioverter-defibrillator.

Adult↗