Additional use for adenosine in anaesthesia and surgery.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to M Lippmann.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Open repair of abdominal aortic aneurysms (AAA) and thoracic aortic aneurysms (TAA) are associated with significant morbidity and mortality. Endovascular aortic aneurysm repair (EVAAR) using a stent graft is a new alternative to traditional open repair. There are various types of anesthesia which can be utilized for EVAAR; specifically general endotracheal anesthesia, regional anesthesia, and monitored anesthesia care (MAC) with local anesthetic infiltrated at the incision site. Choice of anesthetic technique may be dependent upon a patient's co-existing diseases. We have prepared a review article discussing the various types of anesthesia available for this procedure, including the specifics of each technique and pros and cons of each option. The most often utilized technique appears to be general anesthesia, often times related to surgeon unfamiliarity with the EVAAR procedure. Regional techniques, including continuous epidural or continuous spinal anesthesia are utilized in some cases with very good results. This technique can provide more hemodynamic stability and better pain control than general alternative, MAC with local, is an extremely safe and effective technique for the EVAAR procedure, especially in patients with severe co-existing diseases. In addition, this technique also minimalizes sedation and post-operative analgesic requirements, decreases cardiopulmonary complications, and decreases overall hospital stay, thereby reducing cost.
Explore the source record for details and available documents.
HYPOTHESIS: The adverse cardiac event rate following endoluminal abdominal aortic aneurysm (EAAA) repair has decreased as experience in performing the procedure has increased. Aneurysm complexity affects the rate of adverse cardiac events. DESIGN AND PATIENTS: Data from 173 consecutive patients undergoing EAAA repair from 2 successive periods were compared. There were 82 patients in the early group (group 1) and 91 patients in the later group (group 2). MAIN OUTCOME MEASURES: Myocardial infarction, congestive heart failure, unstable angina, major dysrhythmias, death. RESULTS: The cardiac event rate was 8.5% for group 1 vs 16.5% for group 2 (P =.16). Predictors of adverse cardiac events on multivariate analysis were the use of 4 or more graft extensions (P =.04), female sex (P =.01), and number of Eagle risk factors (P<.001). There were 2 postoperative deaths (2.4%) in group 1 and 4 (4.4%) in group 2 (P =.7). CONCLUSIONS: Following EAAA repair: (1) adverse cardiac events were found to correlate with use of 4 or more graft extensions, female sex, and the number of Eagle risk factors; (2) cardiac morbidity and mortality remain significant despite greater experience and improved technology; and (3) operative mortality remains acceptably low.
Physicians caring for patients with community-acquired pneumonia are often faced with the dilemma of how to approach a patient with slowly resolving or even nonresolving pneumonia. When the radiograph has failed to resolve by 50% in 2 weeks or completely in 4 weeks, the pneumonia should be considered to be nonresolving or slowly resolving. The causes of a nonresolving pneumonia and an approach to the work-up are presented.
OBJECTIVE: The objective of this study was to analyze a single-center experience in which descending thoracic aortic aneurysms (TAAs) were treated with a new self-expanding endovascular prosthesis (Medtronic AVE). METHODS: Twenty-six patients (13 men, 13 women) with American Society of Anesthesiology grades II to IV and ages ranging from 53 to 92 years (average, 74 years) consented as part of a Phase I Food and Drug Administration-approved trial. Treated lesions included TAAs that were 5 to 10 cm in diameter, 12 diffuse dilations or fusiform aneurysms, and four saccular aneurysms. There were also nine chronic dissections (2 aneurysmal dilations and 7 symptomatic acute recurrent dissections). Three patients (2 with diffuse/fusiform and 1 with dissection) presented with hemothorax, contrast extravasation, or both. RESULTS: Twenty-five of the 26 patients who consented (96% technical success) were treated successfully with no surgical conversions. Eighteen patients have been followed up from 1 to 22 months (average, 9 months). One patient is lost to follow-up, and six patients have died (24%). One procedure-related death (4%) occurred within the 30-day postoperative period and was caused by diffuse embolization. There were no device-related deaths. Five additional patients (20%) have died during the study of comorbid conditions. Complications included one massive myocardial infarction 24 hours after the procedure requiring balloon counterpulsation and long-term dialysis, one cardiac tamponade resulting from central line placement before the procedure, one progression of aneurysm dilation proximal to the device at 1 year, and one bilateral lower extremity paralysis occurring 12 hours after successful deployment. Seven patients (5 women) had femoral artery reconstructions or iliac artery grafts to repair injuries during deployment catheter passage. Other significant parameters included average procedure time (2 hours 40 minutes; range, 1 hour 30 minutes to 5 hours 30 minutes), 450 cc average blood loss (n = 25; 100-3000 cc) being replaced by means of autotransfusion with only two patients receiving banked blood products, and an average 2 days to resumption of normal diet, 1 day in the intensive care unit, and 5 days' hospitalization postprocedure in uncomplicated cases (n = 22). One patient had an endoleak immediately after the procedure that sealed without treatment. Follow-up of all patients ranging from 1 to 22 months (average, 9 months; n = 18) demonstrates continued exclusion of the aneurysm with no endoleaks and either stable or decreasing aneurysm volume, except in one patient with volume increase and no obvious etiology who continues to be investigated. CONCLUSIONS: The study suggests that endovascular prosthesis exclusion of TAAs with an AneuRx self-expanding tubular device may be effective in many patients who are at significant risk for open surgical repair and substantiates further clinical investigation to confirm these findings.
Explore the source record for details and available documents.
Many organizations around the world have collected data related to individual worker exposures that are used to determine compliance with workplace standards. These data are often warehoused and thereafter rarely used as an information resource. Using appropriate groupings and analysis of OSHA data, Gómez showed that such stored data can provide additional insight on factors affecting occupational exposures. Using data from the Occupational Exposure Database of the United States Navy, the usefulness of statistical models for defining probabilities of exposure above permissible limits for observed work conditions is examined. Analyses have highlighted worker Similar Exposure Groups (SEGs) with potential for overexposure to asbestos and lead. In terms of grouping data, Rappaport et al. defined the Within-Between Lognormal Model, a scale-independent measure for quantifying between-worker variability within a selected worker group: (B)R.95 = exp[3.92s(sB)], representing the ratio of arithmetic mean exposures received by workers in the 97.5th and 2.5th percentiles. To help search for groups, the Proportional Odds Model, a generalization of the logistic model to ordinal data, can predict probabilities for group exposure above the Occupational Exposure Limit (OEL), or the Action Level (AL), which is one-half of the OEL. Worker SEGs have been identified for asbestos workers removing friable asbestos ((B)R.95 = 11.0) and nonfriable asbestos ((B)R.95 = 6.5); metal cleaning workers sandingspecialized equipment ((B)R.95 = 11.3), and workers at target shooting ranges cleaning up lead debris ((B)R.95 = 10). Estimated probabilities for the categories OEL support current understanding of work processes examined. Differences in probability noted between tasks and levels of ventilation validate this method for evaluating other available workplace exposure determinants, and for predicting probability of membership in categories that may help further define worker exposure groups, and determinants of excessive exposures. Thus, analyses of retrospective exposure data can help identify work site and work practice factors for efficient targeting of remediation resources.
Explore the source record for details and available documents.
While particulate matter with aerodynamic diameters below 10 and 2.5 microns (PM10 and PM2.5) correlate with excess mortality and morbidity, there is evidence for still closer epidemiological associations with sulfate ion, and experimental exposure-response studies suggest that the hydrogen ion and ultrafine (PM0.15) concentrations may be important risk factors. Also, there are measurement artifacts in current methods used to measure ambient PM10 and PM2.5, including negative artifacts because of losses of sampled semivolatile components (ammonium nitrate and some organics) and positive artifacts due to particle-bound water. To study such issues, we are developing a semi-continuous monitoring system for PM10, PM2.5, semivolatiles (organic compounds and NH4NO3), particle-bound water, and other PM2.5 constituents that may be causal factors. PM10 is aerodynamically sorted into three size-fractions: (1) coarse (PM10-PM2.5); (2) accumulation mode (PM2.5-PM0.15); and (3) ultrafine (PM0.15). The mass concentration of each fraction is measured in terms of the linear relation between accumulated mass and pressure drop on polycarbonate pore filters. The PM0.15 mass, being highly correlated with the ultrafine number concentration, provides a good index of the total number concentration in ambient air. For the accumulation mode (PM2.5-PM0.15), which contains nearly all of the semivolatiles and particle-bound water by mass, aliquots of the aerosol stream flow into system components that continuously monitor sulfur (by flame photometry), ammonium and nitrate (by chemiluminescence following catalytic transformations to NO), organics (by thermal-optical analysis) and particle-bound water (by electrolytic hygrometer after vacuum evaporation of sampled particles). The concentration of H+ can be calculated (by ion balance using the monitoring data on NO3-, NH4+, and SO4=).
Recent epidemiological evidence strongly suggests that ambient-particle-associated acidity is more closely correlated with total mortality and hospital admissions for respiratory disease than indices of total particulate mass. In addition, evidence is accumulating to support the hypothesis that the number of ultrafine (d < or = 200 nm) acid particles, rather than ambient mass, is an important determining factor affecting lung injury. Both outdoor and indoor air environments are dominated by nanometer-sized particles. However, no data are currently available on the size distribution or number concentration of acidic ambient ultrafine particles largely because there are no suitable methods for measuring these important quantities. We have developed a method to accomplish these measurements based on the use of iron nano-films for detection of acid droplets. Detectors were prepared by vapor deposition of iron onto 12-mm-diameter glass cover slips. The detectors develop reaction sites when exposed to H2SO4 or NH4HSO4 particles. Exposures to non-acidic particle (NaCl and [(NH4)]2SO4) result in no detectable surface deformations. The nano-films are examined with scanning probe microscopy (SPM) for the enumeration of reaction sites. Until recently, direct visualization of individual objects smaller than 200 nm has been possible only with electron microscopy. The advancement of SPM provides the opportunity to examine the detector surface features with high quality three dimensional imaging.
Coronary artery surgery after previous pneumonectomy should be considered a high risk procedure. We describe two cases with associated morbidity and mortality. Pathogenetic mechanisms are discussed.
The development of air pollution standards ideally involves the integration of data from the disciplines of epidemiology, controlled clinical studies, and animal toxicology. Epidemiological studies show statistical associations between health outcomes and exposure; they cannot establish a definite cause-effect relationship. The utility of toxicological studies is to establish this relationship. Recently, there was simultaneous promulgation of a new National Ambient Air Quality Standard (NAAQS) for particulate matter < 2.5 microns in aerodynamic diameter (PM2.5) and a revised NAAQS for ozone (O3). The O3 NAAQS was based, in part, on a sound foundation of toxicological data from controlled exposure studies in humans and animals. It also relied on epidemiological studies of hospital admissions for respiratory diseases. Such studies also served as important bases for the new PM2.5 NAAQS. However, the most influential bases for the PM NAAQS were the numerous and generally consistent epidemiological studies that associated exposure with premature mortality in susceptible subpopulations and the inability of numerous hypothesized confounding factors to negate the associations. Using ozone and PM as examples, this paper discusses the scientific basis for NAAQS promulgations in situations in which the underlying database differed greatly in the extent of toxicological support.
Indices of atmospheric particulate matter (PM) have been reported to be associated with daily mortality and morbidity in a large number of recent time-series studies. However, the question remains as to which components of PM are responsible for the reported associations. Multiple PM components rarely are measured simultaneously. To investigate PM effects on mortality and morbidity, we used the multiple PM components measured in Windsor, Ontario, at a site only a few miles from downtown Detroit, Michigan. This study focused primarily on two study periods in which multiple PM components were measured in Windsor: 1985 to 1990, when levels of total suspended particles (TSP), sulfate from TSP (TSP-SO4(2-)), PM less than 10 microns in diameter (PM10), and nonthoracic TSP (TSP-PM10) were measured throughout the year; and 1992 to 1994, when data on PM10, PM2.5 (PM less than 2.5 microns in diameter), PM10-2.5 (PM10 minus PM2.5), particle acidity (H+), and artifact-free sulfates (SO4(2-)) were available for mostly summer months. Mortality data were analyzed for the 1985 to 1990 study period, and data on both mortality and hospital admissions of elderly patients were analyzed for the 1992 through 1994 period. Poisson regressions were used to estimate the effects of these PM components and gaseous criteria pollutants on mortality (nonaccidental, circulatory, respiratory, and nonaccidental without circulatory and respiratory) and on hospital admissions of elderly patients (for pneumonia, chronic obstructive pulmonary disease [COPD], ischemic heart disease, dysrhythmias, heart failure, and stroke), adjusting for temperature and humidity, trends and seasonal cycles, and day of the week. Both PM10 and TSP were associated significantly with respiratory mortality for the 1985 to 1990 period, with similar relative risk (RR) estimates for PM10 (RR = 1.123; 95% confidence interval [CI] 1.0361-1.218) and TSP (RR = 1.109; 95% CI 1.028-1.197), per 5th to 95th percentile increment. The effect-size estimates for TSP-SO4(2-) and TSP-PM10 were smaller and less significant. In two-pollutant models, simultaneous inclusion of gaseous pollutants with PM10 or TSP reduced PM coefficients by 0 to 34%. The effect-size estimates for total mortality, circulatory mortality, and total minus circulatory and respiratory mortality were less than those for respiratory mortality. Ozone (O3) and nitrogen dioxide (NO2) also were associated significantly with total and circulatory mortality, but a simultaneous consideration of these pollutants with PM10 reduced PM10 coefficients only slightly, or even increased them. In these results, pollution coefficients often were positive at multiple lag days (0-day through 3-day lags were examined), but for PM indices, 1-day lag coefficients were most significant. However, when all combinations of multiple-day average exposures were examined, for cases in which multiple lag days were positive, the choice of single-day or multiple-day average exposure did not appreciably change the estimated effect sizes. An examination of temporal correlation showed that the order of spatial uniformity as expressed by the median site-to-site correlation was O3 (0.83), PM10 (0.78), TSP (0.71), NO2 (0.70), carbon monoxide (CO) (0.50), and sulfur dioxide (SO2) (0.49), which suggests less exposure error for O3 and PM10 than for the other measured pollutants. Thus, these results suggest that spatially homogeneous pollution indices show higher associations with measured health outcomes.
Adult respiratory distress syndrome (ARDS) complicating the course of fulminant hepatic failure is nearly always fatal without orthotopic liver transplantation. We report the case of a 50-year-old woman with fulminant hepatic failure and ARDS that resolved after her recovery from the acute liver failure without liver transplantation. The pathogenesis is discussed, particularly with regard to liver-lung interactions.
Explore the source record for details and available documents.