On the heating of linear conductive structures as guide wires and catheters in interventional MRI.

The interest in performing vascular interventions under magnetic resonance (MR) guidance has initiated the evaluation of the potential hazard of long conductive wires and catheters. The objective of this work is to present a simple analytical approach to address this concern and to demonstrate the agreement with experimental results. The first hypothesis is that a long conductive structure couples with the electric field of the radio frequency (RF) transmit coil. The second hypothesis is that this coupling induces high voltages near the wire ends. These voltages can cause tissue heating due to induced currents. The experimental results show an increase in coupling when moving a guide wire toward the wall of an RF transmit coil, documented with a temperature increase of a saline solution in close proximity to the tip of the guide wire. The coupling of the wire not only presents a potential hazard to the patient, but also interferes with the visualization of the wire. A safe alternative would be the use of nonconducting guide wires. J. Magn. Reson. Imaging 2001;13:105-114.

Catheterization↗

Dynamic magnetic resonance imaging defecography: a diagnostic alternative in the assessment of pelvic floor disorders in proctology.

PURPOSE: Standard diagnostic proctologic procedures in the assessment of pelvic floor disorders include clinical evaluation and endoscopy. Particular aspects of combined pelvic floor disorders, especially those involving more than one pelvic compartment, may remain undetected without additional technical diagnostic procedures such as videoproctoscopy, cinedefecography, or colpocystodefecography. The aim of the study was to review the potentials of dynamic magnetic resonance imaging defecography to elucidate the underlying anatomic and pathophysiologic background of pelvic floor disorders in proctologic patients. PATIENTS AND METHODS: Dynamic magnetic resonance imaging defecography was performed in 20 Patients (13 females) with main diagnoses such as rectal prolapse or intussusception, rectocele, descending perineum, fecal incontinence, outlet obstruction, and dyskinetic puborectalis muscle after clinical evaluation. The investigation was performed on a 1.5 T-magnetic resonance imaging machine in supine position. The rectum was filled with Gd-DTPA enriched ultrasound gel. First a T1/T2 weighted investigation of the pelvis was performed, followed by defecography with evacuation of the rectum. Images were obtained in a sagittal plane in a frequency of 1 image/second (true FISP) at rest and during straining. The obtained magnetic resonance imaging video tapes were analyzed off-line with cinematographic evaluation of bladder base, uterus, and anal canal position in relation to the pubococcygeal line by a blinded radiologist. Investigation time was 20 minutes. RESULTS: In dynamic magnetic resonance imaging defecography of the pelvic floor, 12 patients with descending perineum, 10 rectoceles (10 females), 6 cystoceles (6 females), 4 enteroceles (4 females), 8 intussusceptions (5 females), and a dyskinetic puborectalis muscle in 3 males were detected. In 11 females and 3 males multifocal disorders were found, involving more than one compartment in females, whereas in males complex defects were restricted to the posterior compartment. Magnetic resonance imaging defecography revealed diagnoses consistent with clinical results in 77.3 percent and defects in addition to clinical diagnoses in combined pelvic floor disorders in 34 percent. CONCLUSIONS: In complex pelvic floor disorders, involving more than a single defect, dynamic magnetic resonance imaging represents a convenient diagnostic procedure in females and to a lesser extent in males, in particular in terms of dynamic imaging of pelvic floor organs during defecation. In addition to the clinical assessment, dynamic magnetic resonance imaging had clinical impact in proctologic and interdisciplinary treatment.

Adult↗

Comparison of two-dimensional gradient echo, turbo spin echo and two-dimensional turbo gradient spin echo sequences in MRI of the cervical spinal cord anatomy.

The aim of this study was to assess the detectability and distinguishability of the cervical spinal cord, the anterior and posterior spinal roots and of the internal anatomy of the cord (distinction of grey and white matter). For this purpose 20 healthy volunteers were examined using a 1.5 T MR unit with 20 mT/m gradient strength and a dedicated circular polarized neck array coil. Three T2* weighted (w). 2D gradient echo sequences, two T2 w. 2D turbo spin echo (TSE) sequences and one T2 w. 2D turbo gradient spin echo (TGSE) sequence were compared. The multiecho 2D fast low angle shot (FLASH) sequence with magnetization transfer saturation pulse (me FLASH+MTS) yielded the best results for liquor/compact bone, liquor/spinal cord and grey/white matter contrast, as found with regions of interest (ROI) analysis. The single echo 2D FLASH sequence was significantly poorer than the two me FLASH+/-MTS sequences. Two-dimensional TGSE as well as 2D TSE with a 256 matrix and with a 512 matrix yielded the poorest results. In the visual analysis the contrast between liquor and compact bone, liquor and cord as well as liquor and roots was best with me FLASH+MTS, whereas grey/white matter distinction was best using me FLASH-MTS. In conclusion, we would therefore recommend the inclusion of an axial T2* w. multiecho 2D spoiled gradient echo sequence with magnetization transfer saturation pulse and gradient motion rephasing in a MR imaging protocol of the cervical spine.

Adult↗

Frequency of benign hepatic lesions incidentally detected with contrast-enhanced thin-section portal venous phase spiral CT.

PURPOSE: To evaluate the frequency of benign focal hepatic lesions incidentally detected at contrast-enhanced thin-section portal venous phase spiral CT. MATERIAL AND METHODS: Between January 1998 and February 1999, contrast-enhanced hepatic spiral CT examinations were performed in 1,892 patients. Out of these, only 100 patients fulfilled the following inclusion criteria: No underlying malignant disease, no liver cirrhosis, no suspected or known focal liver lesions. Standardized spiral CT parameters were applied. All CT studies were reviewed retrospectively by one radiologist. Any focal lesion was recorded and classified. Lesion size and number were noted. RESULTS: A total of 108 hepatic lesions were reported in 33 out of 100 patients (80 cysts; 18 hemangiomas; 3 focal fatty infiltrations; 2 focal non-tumorous perfusion defects; 1 calcification; and 4 non-classified lesions). The average lesion size was 9.4 mm (< or =5 mm: n=40; 6-10 mm: n=30; 11-15 mm: n=28; >15 mm: n=10). CONCLUSION: Benign liver lesions are probably a frequent incidental finding at abdominal spiral CT.

Adult↗

[Percutaneous transpapillary extraction of biliary calculi for symptomatic choledocholithiasisafter unsuccessful endoscopic treatment].

PURPOSE: Evaluation of a percutaneous transhepatic treatment of symptomatic choledocholithiasis in bile ducts that cannot be reached with the endoscope. METHODS: From January 1996 to August 2000 a transhepatic extraction of biliary calculus was performed in four patients. Endoscopic retrograde cholangiography (ERC) was not successful in any of the cases. Clinical symptoms were icterus in four cases, additional cholangitis or colics in two cases. First, a balloon dilation of the papilla was performed by a percutaneous transhepatic approach. For removal of bile duct stones, occlusion catheters and Dormia baskets were used. Technical success was defined as complete removal of bile duct stones. Clinical success was defined as normalization of cholestasis and inflammation parameters. In the follow-up an ultrasound examination was performed and blood samples were taken for control of cholestasis parameters. RESULTS: In all four cases treatment was technically and clinically successful. For complete removal of biliary calculus a second intervention was necessary in two cases. In each case an internal to external drainage was left over a mean of 7 days (3-13 days). In the mean follow-up of 30.5 months (6-50 months) all patients had persistent relief of symptoms. No further interventions were necessary. No complications were present. CONCLUSION: Percutaneous transpapillary extraction of biliary calculus is an effective alternative to surgery in patients with bile ducts, that cannot be reached with the endoscope.

Aged↗

[Dynamic MR defecography for diagnosis of combined functional disorders of the pelvic floor in proctology].

PURPOSE: Evaluation of magnetic resonance defecography in the diagnosis of pelvic floor disorders were examined prospectively. MRI was performed on a 1.5 T scanner. The rectum was opacified with 200 ml of ultrasound transmission gel. A sagittal single section T2-weighted gradient echo sequence with a temporal resolution of 1.1 second was performed. Changes of the anorectal angle and the position of the pelvic organs in relation to the pubococcygeal line were registered at rest, during straining, and during evacuation of the rectum. RESULTS: Patients with obstructed defecation (n = 15) showed prolapse of the rectal mucosa (n = 5), anterior rectocele (n = 8), pelvic floor descent (n = 5), enterocele (n = 2), and anorectal dyscoordination (n = 3). Individuals with stool incontinence (n = 15) had an anterior rectocele (n = 10), pelvic floor descent (n = 11), enterocele (n = 2), prolapse of rectal mucosa (n = 1), and a puborectal insufficiency (n = 1). Urine incontinence was associated with cystocele (n = 10) or normal findings (n = 4). In patients with unspecific symptoms (n = 6), anorectal dyscoordination (n = 4) and prolapse of the rectal mucosa (n = 2) were found. MRI was superior for the detection of enteroceles, cystoceles and pelvic floor descent compared with clinical investigation. CONCLUSION: Dynamic MR imaging supplies complex information in anorectal disease and thus improves proctoscopy.

Adolescent↗

[Percutaneous transfemoral implantation of a new, flexible thoracic aorta endoprosthesis using a percutaneous suture system for vascular suture--initial experiences].

PURPOSE: To evaluate the transfemoral placement of a new, flexible stent-graft into the thoracic aorta and the suture-mediated closure of the femoral access. PATIENTS AND METHODS: Five patients were treated endovascularly with a stent-graft for an aneurysm (n = 3) or acute dissection (n = 2) of the thoracic aorta via a femoral 24 F sheath. The femoral access site was closed with two suture-mediated closure devices after placement of the stent-graft. RESULTS: The aneurysm or the false lumen was excluded from perfusion by the placement of the stent-graft in all patients. Hemostasis at the femoral access site was successful in all patients with the percutaneous suture device. A minor stenosis of the femoral artery was found angiographically in four patients after suture-mediated closure. Besides a reversible renal failure due to the medically induced hypotension for the treatment of an acutely ruptured aneurysm, no complications resulted from the stent-graft placement or the percutaneous suture. CONCLUSION: The percutaneous transfemoral placement of stent-grafts in the thoracic aorta using a suture-mediated closure of the access site is technically feasible. Long-term results of the technique have to be awaited.

Aged↗

[Treatment of para-ostium renal artery stenoses with a new, solidly premounted balloon expandable stent].

PURPOSE: Evaluation of the handling, technical success rate, and six-months patency rate of a new, premounted balloon-expandable stent in ostial renal artery stenoses. MATERIAL AND METHODS: In a prospective study, 27 ostial renal artery stenoses in 20 patients were primarily treated with the new "Renal Bridge Stent" (Medtronic AVE, Düsseldorf). All patients had a history of hypertension and 8 patients had renal dysfunction. The handling and visibility of the stent was scored on a three grade scale by the operators. Follow-up angiography including intra-arterial trans-stenotic pressure measurements was performed in 23 out of 27 stenoses (17 patients). RESULTS: Handling and visibility were scored as good by all operators. 26 of 27 stenoses were treated with technical success by implantation of 28 stents. The mean degree of stenosis was reduced from 74.2% to less than 5%. At 6 months, 8 stents out of 23 (35%) showed a significant in-stent stenosis (stenosis degree > 50% and intra-arterial pressure gradient > 10 mmHg). The stenosis rates were 63% using 5-mm stents, 30% using 6-mm stents, and 0% using 7-mm stents. CONCLUSION: Endovascular treatment of ostial renal artery stenosis with the used stent is safe and effective. The new stent shows a good handling and visibility. The high rate of in-stent stenoses might be explained by the rigid follow-up protocol including angiography, trans-stenotic pressure measurements, and the high number of 5-mm vessels in our study.

Adult↗

[CT-guided thoracal sympathicolysis for the treatment of peripheral arterial occlusive disease and chronic thoracal pain syndromes in 6 patients].

UNLABELLED: CT-guided thoracal sympathicolysis for the treatment of peripheral arterial occlusive disease and chronic thoracal pain syndromes in 6 patients. PURPOSE: Retrospective evaluation of the safety and effectivity of CT-guided percutaneous thoracal sympathicolysis (CT-TSL) in the treatment of patients with peripheral arterial occlusive disease (PAOD) of the upper limb and chronic thoracal pain syndromes. Comparison of our own experience with literature reports. MATERIAL AND METHODS: Between 6/96 and 12/99, 4 patients with PAOD of the upper limb and two with chronic thoracal pain syndromes caused by herpes zoster were treated by unilateral CT-TSL. RESULTS: 18, 21 and 32 months after the intervention 3 out of 4 patients treated for PAOD reported subjective improvements, and one remained unchanged. Two patients treated for pain syndromes showed no long-term benefit of the procedure. There were no serious complications. CONCLUSION: The CT-TSL is an alternative method in the treatment of PAOD in patients who are unsuitable for treatment by revascularization.

Aged↗

[Indirect MR Arthrography of the wrist in the diagnosis of TFCC-Lesions].

PURPOSE: The objective of this prospective study was to assess the value of the indirect MR arthrography (MR-AR) of the wrist in the detection of lesions of the TFCC. MATERIAL AND METHODS: Indirect MR-AR was performed in 45 patients (23 f/22 m) with unclear ulnar wrist pain. After i. v. injection of 0.1 mmol/kg Gd-DTPA and after a motion-phase of the wrist (15 minutes) MRI was performed in a coronal plane. We used a STIR-, a fatsaturated (fs) T1-SE and a 3D-DESS sequence. The images were evaluated by two radiologists using a consensus score. The lesions were assigned to the system of Palmer and correlated with arthroscopy. RESULTS: Indirect MR-AR showed in 35 of 45 patients a lesion of the TFCC, but arthroscopy only revealed a defect in 32 cases. This means three false positive but no false negative assessments by MRI. Using this MRI protocol sensitivity and specificity in the detection of TFCC lesions were calculated as 100 % and 77 %. The accuracy was 93 %. Small degenerative changes of the fibres were most common (Palmer type II A). In trauma patients the ligaments usually showed tears near the insertion at the ulna (Palmer type I B). The sensitivity and specificity was 88 % and 95 % for evaluation of the scapho-lunate (SL) ligament, the accuracy was 93 %. Arthroscopy and MRI did not diagnose any rupture of the lunate-triquetral (LT) ligament. CONCLUSION: Indirect MR-AR is a non-invasive method with a high sensitivity in the evaluation of the TFCC and associated injuries. Therefore, it is an excellent screening procedure to assess the indication for therapeutic arthroscopy.

Adolescent↗

Quantification of blood flow in the carotid arteries: comparison of Doppler ultrasound and three different phase-contrast magnetic resonance imaging sequences.

RATIONALE AND OBJECTIVES: To compare blood flow velocities in the carotid arteries measured with three different magnetic resonance (MR) phase-contrast imaging techniques and with percutaneous Doppler ultrasound. METHODS: Fourteen healthy male volunteers with a mean age of 33 +/- 3.8 years were studied. Ultrasound and MR phase velocity mapping of both common carotid arteries (n = 28) was performed within 5 hours. A two-dimensional fast low-angle shot sequence with retrospective cardiac gating, a sequence with prospective cardiac triggering, and a breath-hold sequence with prospective cardiac triggering were used. Resistance indexes and pulsatility indexes were calculated for all modalities. RESULTS: The comparison of flow velocities obtained with ultrasound and the different MR techniques led to a moderate correlation of the retrospective gated and prospective triggered MR techniques (eg, r = 0.73 for maximum systolic velocity). The worst correlation was found between the breath-hold technique and retrospective cardiac gating (eg, r = 0.004 for pulsatility index). There was a weak correlation of all three MR sequences compared with ultrasound (r = 0.19-0.60) CONCLUSIONS: A moderate correlation was found between velocities and indexes measured with the prospective cardiac-triggered phase-contrast MR technique and the retrospective cardiac-gated phase-contrast MR technique. A weak correlation was found between the three different MR techniques and ultrasound, as well as between the breath-hold prospective cardiac-triggered MR sequence and both of the other MR sequences. The influence of temporal and spatial resolution on MR phase-contrast velocity mapping was confirmed.

Adult↗

Appearance of vascular stents in computed tomographic angiography: in vitro examination of 14 different stent types.

RATIONALE AND OBJECTIVES: To evaluate the appearance of the vessel lumen after implantation of different vascular stents with the use of a computed tomographic (CT) angiography model. METHODS: A vascular phantom was studied with helical CT and different slice thicknesses (2 and 3 mm) and pitch values (1.0, 1.5, and 2.0). Original transverse CT images and coronal reformations were evaluated. Fourteen different stents were analyzed with regard to changes in the stent lumen (attenuation values, noise, and artificial lumen narrowing). RESULTS: Some stents caused artifacts resulting in potential errors during evaluation of their patency. Assessment of the lumen was impaired in two stents (Strecker tantalum and Passager). Increased attenuation values were measured in all stents (increase of 8%-145%). The degree of artificial lumen narrowing was 4.4% to 77.8%. CONCLUSIONS: In most stents, reliable evaluation of the stent lumen seems possible. However, knowledge of the artifacts caused by different stent types is useful for the assessment of stent patency with CT angiography.

Angiography↗

MR imaging-guided stent placement in iliac arterial stenoses: a feasibility study.

PURPOSE: To assess the feasibility of magnetic resonance (MR) imaging-guided stent placement in iliac arterial stenoses. MATERIALS AND METHODS: Thirteen patients with 14 iliac arterial stenoses were examined prospectively. Angioplasty was performed through a femoral sheath by using a conventional 1.5-T MR imaging system. Stents and catheters were visualized on the basis of their artifacts. Nitinol stents were placed with gradient-echo MR imaging guidance. Angioplasty balloons were inflated with gadolinium-based contrast material. Results were evaluated clinically and with both digital subtraction angiography (DSA) and contrast material-enhanced MR angiography. RESULTS: Ten of 13 patients were treated with technical success by using MR imaging-guided intervention alone. Three patients were treated with additional fluoroscopic guidance, because complications (ie, panic attack, subintimal recanalization, and stent misplacement) occurred with MR guidance. The quality of the postinterventional contrast-enhanced MR angiograms of three of 12 lesions with stents was limited owing to stent-induced signal loss of the lumen. The mean stenosis degree after stent placement was significantly higher at contrast-enhanced MR angiography than at DSA (24.6% vs 6.2%). The mean MR imaging-guided procedure time was 74 minutes. CONCLUSION: MR imaging-guided stent placement in iliac arteries is feasible in select patients. The presented technique has limitations-that is, long procedure times, lack of real-time monitoring, and stent artifacts-that necessitate further modifications before it can be recommended for clinical use.

Aged↗

Renal time-resolved MR angiography: quantitative comparison of gadobenate dimeglumine and gadopentetate dimeglumine with different doses.

PURPOSE: Results with different doses of gadobenate dimeglumine and gadopentetate dimeglumine were compared at magnetic resonance (MR) angiography of the renal arteries. The signal-to-noise ratio (SNR) was evaluated as a quantitative measure of image quality. MATERIALS AND METHODS: Sixty consecutive patients (age range, 24-81 years; mean age, 65 years) underwent intraarterial digital subtraction angiography (DSA) and contrast material-enhanced time-resolved MR angiography. DSA was the standard of reference. Fifteen patients received gadopentetate dimeglumine at doses of 0.2 or 0.1 mmol per kilogram of body weight. Fifteen patients received gadobenate dimeglumine at doses of 0.05 or 0.1 mmol/kg. The SNR was calculated in the aorta and both main renal arteries. The number and degree of stenoses of the renal arteries and accessory vessels were evaluated by four observers. RESULTS: SNRs with gadobenate dimeglumine at a dose of 0.1 mmol/kg were significantly superior to those with gadopentetate dimeglumine at a dose of 0.1 mmol/kg. Differences were not statistically significant between the SNRs in the other groups. Eleven (85%) of 13 hemodynamically significant renal artery stenoses were detected correctly with MR angiography as were 22 (85%) of 26 accessory renal arteries. CONCLUSION: SNRs with gadobenate dimeglumine were higher than those with gadopentetate dimeglumine, but in most cases the differences in SNRs were not statistically significant.

Adult↗

Spinal metastases from renal cell carcinoma: effect of preoperative particle embolization on intraoperative blood loss.

BACKGROUND AND PURPOSE: Surgical repair of spinal metastases from renal origin is often complicated by excessive bleeding. The purpose of this study was to assess the effect of preoperative particulate embolization on intraoperative blood loss. METHODS: Twenty spinal metastases from renal origin (17 patients) treated by preoperative embolization with polyvinyl alcohol particles were analyzed retrospectively. Surgical decompression was performed within 2 days after embolization. A control group of 10 patients with 11 spinal metastases of renal origin underwent surgery without embolization. The effect of preoperative embolization, of completeness of embolization, and of particle size on the estimated intraoperative blood loss was analyzed using nonparametric statistical tests. RESULTS: Complete embolization was achieved in 10 cases and partial embolization in the other 10. The estimated blood loss of 19 embolized and 11 control cases was available from the surgical report. Median intraoperative blood loss in 19 embolized lesions was 1500 mL (range, 300-8000 mL), compared with 5000 mL (range, 1440-15000 mL) in the control group. Even after partial embolization, blood loss (median, 2000 mL) was significantly lower than in the control group. No significant differences in estimated blood loss were noted between the use of particles smaller than 250 microm and those larger than 250 microm. No embolization-related permanent neurologic deficit or skin or muscle necrosis occurred. CONCLUSION: Preoperative embolization of spinal metastases of renal origin with polyvinyl alcohol particles is safe and might reduce intraoperative blood loss significantly. Even partial embolization seems to be effective.

Aged↗

Digital radiography of the skeleton using a large-area detector based on amorphous silicon technology: image quality and potential for dose reduction in comparison with screen-film radiography.

AIM: The purpose of this study was to evaluate a large-area, flat-panel X-ray detector (FD), based on caesium-iodide (CsI) and amorphous silicon (a-Si) with respect to skeletal radiography. Conventional images were compared with digital radiographs using identical and reduced radiation doses. MATERIALS AND METHODS: Thirty consecutive patients were studied prospectively using conventional screen-film radiography (SFR; detector dose 2.5 microGy). Digital images were taken from the same patients with detector doses of 2.5, 1.25 and 0.625 microGy, respectively. The active-matrix detector had a panel size of 43 x 43 cm, a matrix of 3 x 3K, and a pixel size of 143 microm. All hard copies were presented in a random order to eight independent observers, who rated image quality according to subjective quality criteria. Results were assessed for significance using the Student's t -test (confidence level 95%). RESULTS: A statistically significant preference for digital over conventional images was revealed for all quality criteria, except for over-exposure (detector dose 2.5 microGy). Digital images with a 50% dose showed a small, statistically not significant, inferiority compared with SFR. The FD-technique was significantly inferior to SFR at 75% dose reduction regarding bone cortex and trabecula, contrast and overall impression. No statistically significant differences were found with regard to over- and under-exposure and soft tissue presentation. CONCLUSION: Amorphous silicon-based digital radiography yields good image quality. The potential for dose reduction depends on the clinical query.

Aged↗

[3D CISS, 3D MP-PAGE and 2D TSE for the preoperative MRI prior to cochlear implantation].

PURPOSE: The aim of this study was to determine the presurgical predictive value of high resolution MRI in patients scheduled for cochlear implantation. METHOD AND MATERIAL: The presurgical MRI (3D CISS, 3D MP-RAGE with and without i.v. contrast medium, 2D TSE) findings of 54 patients and the intraoperative situation reported by the surgeon were compared retrospectively. The surgical and functional success of the cochlear implantation was evaluated. RESULTS: We found a high degree of correlation between MRI and intraoperative findings concerning the patency of the whole cochlea and anomalies as well as in the diagnosis of pathology of the cochlear, vestibular and facial nerves and in anomalies of the internal auditory canal. However, in four out of 54 patients there was a false negative prediction regarding the patency of the cochlea. The sensitivity was 50% (4/8), the specificity 100% (46/46). Concerning the surgical success the accuracy was 100%. In all patients MRI gave sufficient anatomical information to the surgeon concerning the jugular bulb and the facial nerve. CONCLUSION: A high-resolution MRI protocol consisting of coronal 2D T2w TSE, 3D T2*w transverse CISS; plain and contrast enhanced sagittal T1w 3D MP-RAGE is recommended for the evaluation of candidates scheduled for cochlear implantation.

Adolescent↗

[Stent angioplasty of pelvic artery stenosis with MRI control: initial clinical results].

PURPOSE: To investigate the feasibility of MR-guided stent angioplasty of iliac artery stenoses under passive visualization. MATERIAL AND METHODS: Three patients with short, concentric stenoses of the iliac arteries were enrolled. The vascular interventions were performed on a 1.5 T MR scanner (Magnetom Symphony, Siemens, Erlangen, Germany). Stents, guidewires, and balloon catheters were visualized on the basis of susceptibility artifacts. Contrast-enhanced MR angiography (ceMRA) was used to localized the stenosis prior to stent deployment. Nitinol stents were placed under MR-guidance using a fast 2D gradient echo technique. Balloon dilatiation was performed with an angioplasty catheter inflated with diluted gadolinium-DTPA. Postinterventional results were evaluated by ceMRA, DSA, and Doppler indices. RESULTS: Position of the stent, stent deployment, and balloon dilatation were depicted by MR. All stents were correctly placed within the stenosis. Stent positions as monitored by MRI were identical to those seen on DSA images. All patients were treated successfully by the MR-guided intervention. CONCLUSION: An MR-guided stent angioplasty of simple iliac artery stenosis is feasible under passive visualization.

Aged↗