Clinical application of endovascular grafts in aortoiliac occlusive disease and vascular trauma.

Intravascular stents and stented grafts are becoming important tools for the management of a variety of vascular lesions. This review addresses the technical feasibility and early results of aortoiliac endovascular reconstructions for limb salvage as well as the placement of stented grafts for the treatment of traumatic arterial lesions. Eighteen patients with limb-threatening ischemia secondary to aortoiliac and femoropopliteal occlusive disease who were poor candidates for standard arterial bypass operations and eight patients with traumatic arterial lesions (two arteriovenous fistulas; six pseudoaneurysms) were treated with endovascular stented grafts. These were constructed of 6-mm tubular polytetrafluoroethylene (GORE-TEX) and balloon-expandable stents (Palmaz). Technical success was achieved in 95% of grafts placed to treat long segment occlusive disease of the iliofemoral arteries and in 100% of grafts placed to treat traumatic arterial injuries. There were no deaths and only minor complications in both groups. Although the early results with these grafts are encouraging, long-term follow-up is needed before such devices can be recommended for widespread use.

Aged↗

Transfemoral endovascular repair of iliac artery aneurysms.

PURPOSE: This report evaluates the application of transfemoral endovascular repair of iliac artery aneurysms. PATIENTS AND METHODS: Over a 20-month period, 11 patients with serious comorbid illnesses and a total of 14 iliac artery aneurysms were treated with endovascular grafts composed of polytetrafluoroethylene conduits combined with balloon expandable iliac artery stents (Palmaz). Nine right common, 3 left common, and 2 right internal iliac artery aneurysms were treated. The patients were men between 58 and 89 years of age (mean 72). Eight patients had isolated aneurysms and 3 had multiple iliac artery aneurysms. RESULTS: Endovascular iliac grafts were successfully placed in all 11 patients. No procedural deaths occurred. Follow-up ranged from 3 to 21 months (mean 11). No acute or late graft thromboses occurred. CONCLUSIONS: Transluminally placed endovascular stented grafts can be used to successfully exclude iliac artery aneurysms from the circulation while maintaining lower-extremity arterial perfusion. However, longer follow-up in more patients is necessary to confirm the durability of this technique.

Aged↗

Endovascular aortoiliac grafts in combination with standard infrainguinal arterial bypasses in the management of limb-threatening ischemia: preliminary report.

PURPOSE: Occlusive disease of the aortoiliac segment may lead to limb-threatening ischemia, if coexisting disease is present in the femoral, popliteal, or tibial arteries. The combined treatment of severe aortoiliac and infrainguinal disease with standard techniques may be hazardous or contraindicated in patients with multiple previous reconstructions, severe comorbid medical illnesses, or both. This report summarizes the technical feasibility and early results of aortoiliac endovascular stented grafts (ESGs) in combination with conventional surgical reconstructions for the treatment of multilevel arterial occlusive disease. METHODS: Seventeen patients with multilevel aortoiliofemoral limb-threatening occlusive disease had an ESG inserted to treat long-segment occlusive disease followed by a conventional surgical bypass. ESGs originated from the aortoiliac junction (seven) or the common iliac artery (10) and were inserted into the common femoral (nine), superficial femoral (four), or deep femoral (four) artery. ESG lengths ranged from 16 to 30 cm (mean, 21 cm). Conventional surgical bypasses were constructed from polytetrafluoroethylene (15) or saphenous vein (two) and extended to the popliteal (12), tibial (two), or contralateral femoral (three) arteries. RESULTS: Technical success in graft insertion was achieved in 17 (94%) of 18 attempted ESG procedures. The 1-year primary and secondary cumulative patency rates for ESGs were 94% +/- 10% and 100%, respectively, whereas the 1- and 2-year patency rates for the extravascular grafts were 92% +/- 10% and 100%, respectively. Four patients had minor postprocedure complications (23%), and no deaths occurred. One patient lost his limb at 16 months because of severe pedal sepsis. CONCLUSIONS: Transluminally placed stented grafts in combination with conventional surgical infrainguinal bypasses are a technically feasible and potentially safe option for the treatment of limb-threatening aortoiliofemoral occlusive disease and have demonstrated encouraging early patency. Long-term follow-up will be necessary before widespread application of this technique is advocated.

Adult↗

Human transluminally placed endovascular stented grafts: preliminary histopathologic analysis of healing grafts in aortoiliac and femoral artery occlusive disease.

PURPOSE: The purpose of this study was to perform a preliminary histopathologic analysis of explanted human endovascular stented grafts from patients treated for occlusive disease. METHODS: Over a 16-month period, 26 endovascular stented grafts were placed in 21 patients with limb-threatening ischemia caused by aortoiliac or femoral artery occlusive disease. All grafts were inserted through open arteriotomies remote from the region of primary disease. During the follow-up period, two patients died of preexisting heart disease 2 weeks and 7 months after grafting, and a portion of their endovascular grafts were the surrounding artery was explanted. Specimens from five other endovascular grafts were obtained during surgical revision for graft stenosis after 3 and 6 weeks and for outflow artery stenosis after 3, 5, and 6 months. All specimens were formalin fixed and studied with hematoxylin and eosin and trichrome staining and immunohistochemically for factor VIII-related antigen, alpha actin smooth muscle, macrophage antigen (MAC-387) and PC-10 (a mouse monoclonal antibody which specifically recognizes proliferating cell nuclear antigen in paraffin sections). RESULTS: Three weeks after placement of the stented grafts, organizing thrombus was present on both surfaces of the expanded polytetrafluoroethylene (PTFE) grafts. At 6 weeks, evidence of a neointima with overlying endothelium was seen in the perianastomotic region, and 3 months after grafting it was seen 1 to 3 cm from the anastomosis. The specimen explanted at 5 months demonstrated factor VIII-positive cells 8 cm from the anastomosis. The histopathologic condition of the external capsule appeared to vary, depending on the presence or absence of an external wrap on the PTFE graft and on which layer in the arterial wall the graft was inserted. A foreign body reaction characterized by multinucleated giant cells was seen adjacent to wrapped grafts or around those placed in an intraadventitial plane. Grafts inserted within the media were surrounded by orderly, arranged, smooth muscle cells and few mononuclear cells. Extensive smooth muscle cell proliferation (PC-10 activity) was not seen within native artery atherosclerotic plaques peripherally displaced and external to prosthetic endovascular grafts. CONCLUSIONS: These preliminary observations on the healing of PTFE endovascular stented grafts in human beings demonstrate limited plaque hyperplasia and the presence of endothelial cells on the luminal surface remote from the graft-artery anastomosis. It is unclear whether this is a unique manifestation of healing in prosthetic grafts inserted within the walls of arteries.

Actins↗

Initial experience with transluminally placed endovascular grafts for the treatment of complex vascular lesions.

OBJECTIVES: Complex arterial occlusive, traumatic, and aneurysmal lesions may be difficult or impossible to treat successfully by standard surgical techniques when severe medical or surgical comorbidities exist. The authors describe a single center's experience over a 2 1/2-year period with 96 endovascular graft procedures performed to treat 100 arterial lesions in 92 patients. PATIENTS AND METHODS: Thirty-three patients had 36 large aortic and/or peripheral artery aneurysms, 48 had 53 multilevel limb-threatening aortoiliac and/or femoropopliteal occlusive lesions, and 11 had traumatic arterial injuries (false aneurysms and arteriovenous fistulas). Endovascular grafts were placed through remote arteriotomies under local (16[17%]), epidural (42[43%]), or general (38[40%]) anesthesia. RESULTS: Technical and clinical successes were achieved in 91% of the patients with aneurysms, 91% with occlusive lesions, and 100% with traumatic arterial lesions. These patients and grafts have been followed from 1 to 30 months (mean, 13 months). The primary and secondary patency rates at 18 months for aortoiliac occlusions were 77% and 95%, respectively. The 18-month limb salvage rate was 98%. Immediately after aortic aneurysm exclusion, a total of 6 (33%) perigraft channels were detected; 3 of these closed within 8 weeks. Endovascular stented graft procedures were associated with a 10% major and a 14% minor complication rate. The overall 30-day mortality rate for this entire series was 6%. CONCLUSIONS: This initial experience with endovascular graft repair of complex arterial lesions justifies further use and careful evaluation of this technique for major arterial reconstruction.

Adolescent↗

Endovascular repair of abdominal aortic aneurysm: value of postoperative follow-up with helical CT.

OBJECTIVE: Transfemorally placed endoluminal grafts are currently being evaluated as an alternative to open surgery for the treatment of abdominal aortic aneurysms. We determined the value of helical CT for the follow-up of patients treated with this new procedure. The purposes of this study were to determine CT features of a technically successful procedure, detect complications, and compare findings on CT scans obtained 24-48 hr after insertion of the graft with findings on angiograms obtained at the end of the endovascular procedure. SUBJECTS AND METHODS: Seven patients with large abdominal aortic aneurysms had helical CT within 48 hr after transfemoral insertion of an endoluminal graft. Findings on these CT scans were compared with findings on digital completion angiograms obtained immediately after placement of the graft. Additional follow-up CT scans were obtained for up to 15 months (mean, 8 months). The size of the aneurysmal sac; completeness of perigraft thrombosis; and position, shape, and patency of the device were recorded. RESULTS: CT scans obtained 24-48 hr after placement of the grafts showed complete thrombosis of the aneurysmal sac in three patients and incomplete thrombosis with patent perigraft channels in the four remaining patients. Angiograms showed a patent perigraft channel in only one patient. Two of four initially patent channels subsequently closed, but one of them recurred. Of four thrombosed aneurysms, two decreased in size, and two were unchanged on later follow-up. Of three aneurysms associated with perigraft channels, two became enlarged and one was stable. On the basis of CT criteria, successful endovascular repair was shown in four (57%) of seven patients. CONCLUSION: Helical CT is a sensitive means of evaluating the efficacy of endoluminal grafts. Decreased or stable size of the aneurysmal sac without perigraft channels on late follow-up CT signifies technical success. Persistence or recurrence of perigraft channels is the most likely cause of later enlargement of an aneurysm and therefore suggests procedural failure. Helical CT was more sensitive than angiography for detection of perigraft channels that occurred soon after treatment.

Aged↗

Endovascular stented graft repair of a pseudoaneurysm of the subclavian artery caused by percutaneous internal jugular vein cannulation: case report.

In high-risk patients endovascular repair of a pseudoaneurysm with a stented graft is a safe and reasonable treatment option that can preclude significant morbidity and shorten hospital stay. We report a case of pseudoaneurysm of the subclavian artery after internal jugular vein cannulation that was treated successfully with an endovascularly inserted, stented graft. The case report highlights the importance of recognizing this unusual but serious complication of percutaneous internal jugular vein catheterization through careful clinical examination, prompt duplex scanning, and arteriography.

Aged↗

Transluminally placed endovascular stented graft repair for arterial trauma.

PURPOSE: Intravascular stents have become important tools for the management of vascular lesions; however, stents in combination with vascular grafts have only recently reached clinical application. This report describes an experience with stented grafts for the treatment of penetrating arterial trauma. METHODS: Seven transluminally placed stented grafts were used to treat one arteriovenous fistula and six pseudoaneurysms. These grafts were successfully inserted percutaneously or through open arteriotomies that were remote from the site of vascular trauma. The devices were composed of balloon-expandable stainless steel stents covered with polytetrafluoroethylene grafts. RESULTS: Patency up to 14 months was achieved (mean follow-up 6.5 months) with these stented grafts. The use of stented grafts appears to be associated with decreased blood loss, a less invasive insertion procedure, reduced requirements for anesthesia, and a limited need for an extensive dissection in the traumatized field. These advantages are particularly important in patients with central arteriovenous fistulas or false aneurysms who are critically ill from other coexisting injuries or medical comorbidities. CONCLUSIONS: The use of stented grafts already appears justified to treat traumatic arterial lesions in critically ill patients. Although the early results with the seven cases in this report are encouraging, documentation of long-term effectiveness must be obtained before these devices can be recommended for widespread or generalized use in the treatment of major arterial injuries.

Adult↗

Eleven-year experience with tibiotibial bypass: an unusual but effective solution to distal tibial artery occlusive disease and limited autologous vein.

PURPOSE: The absence of sufficient length of suitable autologous vein occasionally prohibits the treatment of severe distal lower extremity arterial occlusive disease with a standard distal bypass originating from the common femoral artery. During the past 11 years, we have therefore selectively performed short distal bypasses originating from the infrapopliteal arteries in patients with limb-threatening ischemia and occlusive lesions limited to the distal tibial and peroneal arteries. This report summarizes our experience with these tibial artery based distal bypasses. METHODS: Forty-two distal lower extremity arterial bypasses originating from infrapopliteal arteries in 41 patients were performed over an 11-year period. Autologous vein was used as the bypass conduit in all cases. Extensions from a more proximal bypass were excluded. RESULTS: The primary patency rate of these tibiotibial bypasses was 77% at 1 year and 62% after 5 years. The limb salvage rate after 5 years was 74%. The perioperative mortality rate was low (2%), but the 5-year patient survival rate (64%) was similar to that with more standard lower extremity arterial reconstructive procedures. CONCLUSIONS: Tibiotibial bypass is an effective limb salvage procedure in carefully selected patients with distal tibial artery occlusive disease and limited autologous vein. It offers a durable means of distal revascularization in circumstances in which a standard operation might not be desirable or possible.

Adult↗

Is percutaneous balloon angioplasty appropriate in the treatment of graft and anastomotic lesions responsible for failing vein bypasses?

We reviewed 95 cases of vein graft and anastomotic lesions treated with percutaneous transluminal balloon angioplasty (PTA) and 30 cases treated surgically. The therapy was deemed a failure if the lesion recurred or if the graft closed. The 21-month patency rate of lesions treated surgically was 86%, which was significantly better than the 42% patency rate for all lesions treated with PTA (P < 0.01). An evaluation of the lesion and graft characteristics that could influence the patency of stenotic lesions treated with PTA included: lesion length, minimum graft diameter, lesion location, and lesion type. The 66% patency rate at 24 months for the 41 simple lesions (single, nonrecurrent, < 15 mm in length, and within grafts > or = 3 mm minimal diameter) was significantly better than the 17% patency rate for the 50 complex lesions (multiple, recurrent, > or = 15 mm in length, or within grafts < 3 mm in minimal diameter) (P < 0.01). In addition, the 21-month patency rate for the surgically treated group (86%) was not significantly better than that of the angioplasty-treated simple lesions (66%). When feasible, vein graft lesions are best treated with simple surgical interventions. PTA can be useful to maintain the patency of severely compromised grafts prior to surgical repair, to treat simple lesions difficult to reach surgically, and for patients with medical contraindications for an operation.

Aged↗

Transfemoral endovascular stented graft treatment of aorto-iliac and femoropopliteal occlusive disease for limb salvage.

BACKGROUND: Endovascular stented grafts employ a new technique that blends intravascular stent and prosthetic graft technologies. These devices may be used to treat arterial aneurysms, occlusive disease, and vascular injuries. This report describes the application of stented grafts to the treatment of limb-threatening ischemia secondary to occlusive disease of the aorta, iliac, and femoral arteries. METHODS: Three patients with limb-threatening ischemia and severe comorbid medical illnesses were treated with transvascular stented grafts that were composed of 6-mm thin-walled polytetrafluoroethylene grafts and Palmaz balloon expandable stents. The grafts were inserted through a cutdown in an artery remote from the site of occlusion and introduced into the vascular system within 14-Fr introducer sheaths. RESULTS: Technical success was documented in all three patients with restoration of arterial continuity following stent graft deployment. Patency and limb salvage has been achieved to 1 year. One patient required further dilatation of the proximal stent at 6 weeks. Complications were limited to an iliofemoral deep vein thrombosis in one patient. CONCLUSIONS: Endovascular stented grafts can be inserted to treat limb-threatening ischemia. Although these initial results are encouraging, greater experience in more patients observed for longer periods of time is necessary before this technique can be advocated for widespread use.

Aortic Diseases↗

Transfemoral endoluminal stented graft repair of a popliteal artery aneurysm.

This report describes the use of an endoluminally placed stented graft to repair a large (2.6 by 2.6 by 15 cm) popliteal aneurysm in a 63-year-old man with advanced heart disease. Two balloon-expandable stents were attached to a 6 mm polytetrafluoroethylene graft, which was inserted with the patient receiving local anesthetic through a proximal superficial femoral artery arteriotomy. Repeat arteriography and duplex ultrasonography performed up to 3 months after the procedure documented graft and distal artery patency and complete aneurysmal exclusion without distal emboli. This experience demonstrates technical feasibility and early graft patency. However, additional experience and follow-up will be needed to assess the value of this minimally invasive procedure in the management of popliteal aneurysmal disease.

Aneurysm↗

Human greater saphenous vein: histologic and ultrastructural variation.

This study describes the varied histologic features and ultrastructure of human saphenous veins obtained from patients undergoing infrainguinal arterial reconstruction. Portions of 30 remnant veins were fixed at arterial pressure (100 mmHg). Vein specimens were obtained from 13 men and 17 women, with a mean age of 70.2 years. Ten veins (33%) were from diabetic patients. Samples of fixed veins were prepared for light and electron microscopy. The luminal surface contained valves and redundant intimal folds at the site of ligated side branches. Microvalves were present at the orifices of several 1-mm vein tributaries. The endothelial cells lining the intima were often discontinuous and were aligned in a variable pattern. The thicknesses of the vein walls varied from 20 to 360 microns, with increased connective tissue matrix in the intima and medial layers of thick-walled veins. Some 10% of the veins demonstrated spindle cells in the intima; these cells had a smooth muscle cell phenotype and varied with respect to the degree of cellular differentiation. Regions of vein wall calcification were occasionally seen and were always present in association with a thickened vein intima. Variations in the structure of the saphenous vein from patients undergoing bypass surgery are common. The relationship between altered saphenous vein morphology and subsequent vein graft stenosis needs to be defined.

Adult↗