Search PubMed⌕ Search

Biomedical subjects

M L Blázquez

Publications and source records attributed to M L Blázquez.

7 recordsLinked to original sources

Biosorption of heavy metals by activated sludge and their desorption characteristics.

The biosorption of different metals (Cu2+, Cd2+, Zn2+, Ni2+ and Pb2+) was investigated using activated sludge. The optimum pH was 4 for Cd, Cu and Pb sorption and 5 for Ni and Zn. Biomass metal uptake clearly competed with protons present in the aqueous medium, making pH an important variable in the process. Protons consumed by biomass in control tests versus protons exchange in biosorption tests confirmed a maximum exchange between metal cations and protons at pH 2. The study of the influence of biomass concentration revealed that the amount of protons released from biomass increased with biomass concentration. This would confirm the hypothesis of ion exchange between both types of ions. The application of the Langmuir and Freundlich models showed a better fitting of experimental data to the first model. The maximum sorption uptake of the studied metals by the activated sludge showed the following decreasing order: Pb>Cu>CdZn>Ni. Desorption experiments showed that HCl was a good eluent for the five metals tested, particularly at low pH values (1 and 2). At pH 3 or 4 the desorption yield was significantly lower. However, its use did not allow the reuse of biomass in subsequent loading and unloading cycles. EDTA was also a good desorption agent, achieving the total recovery for the five metals tested at a concentration of 1mM, with the advantage that biomass could be reused for three sorption-desorption cycles.

Adsorption↗

Microbial activity in weathering columns.

The aim of the present work was to evaluate the metabolic activity of the microbial population associated with a pyritic tailing after a column-weathering test. For this purpose, a column 150cm high and 15cm diameter was used. The solid was a tailing with 63.4% pyrite and with minor amounts of Cu, Pb and Zn sulfides (1.4, 0.5 and 0.8%, respectively). The column model was the habitual one for weathering tests: distilled water was added at the top of the column; the water flowed down through tailings and finally was collected at the bottom for chemical and microbiological analysis. Weathering was maintained for 36 weeks. The results showed a significant presence of microbial life that was distributed selectively over the column: sulfur- and iron-oxidizing aerobic bacteria were in the more oxygenated zone; anaerobic sulfur-reducing bacteria were isolated from the samples taken from the anoxic part of the column. Activity testing showed that (oxidizing and reducing) bacteria populations were active at the end of the weathering test. The quality of the water draining from the column was thus the final product of biological oxidation and reduction promoted by the bacteria consortia.

Bacteria, Aerobic↗

Gold and silver uptake and nanoprecipitation on calcium alginate beads.

Calcium alginate beads were investigated for their biosorption performance in the removal of gold and silver from aqueous solutions. It was found that uptake capacities were significantly affected by the solution pH, with optimum pH values of 2 and 4 for gold and silver, respectively. Kinetic and isotherm experiments were carried out at the optimum pH. The maximum uptake capacities were 290 mg/g for Au and 52 mg/g for Ag. FTIR analysis indicated that both carboxylic and hydroxylic functional groups in alginate beads are involved in the metal binding and later reduction of gold (+3) and silver (+1) to gold (0) and silver (0). SEM and X-ray diffraction confirmed the formation of gold and silver nanoparticles.

Adsorption↗

Factors affecting the transformation of a pyritic tailing: scaled-up column tests.

Two different methods for predicting the quality of the water draining from a pyritic tailing are compared; for this, a static test (ABA test) and a kinetic test in large columns were chosen. The different results obtained in the two experimental set-ups show the necessity of being careful in selecting both the adequate predictive method and the conclusions and extrapolations derived from them. The tailing chosen for the weathering tests (previously tested in shake flasks and in small weathering columns) was a pyritic residue produced in a flotation plant of complex polymetallic sulphides (Huelva, Spain). The ABA test was a modification of the conventional ABA test reported in bibliography. The modification consisted in the soft conditions employed in the digestion phase. For column tests, two identical methacrylate columns (150 cm high and 15 cm diameter) were used to study the chemical and microbiological processes controlling the leaching of pyrite. The results obtained in the two tests were very different. The static test predicted a strong potential acidity for the tailing. On the contrary, pH value in the effluents draining from the columns reached values of only 5 units, being the concentration of metals (<600 mg/L) and sulphate ions (<17,000 mg/L) very small and far from the values of a typical acid mine drainage. In consequence, the static test may oversize the potential acidity of the tailing; whereas large columns may be saturated in water, displacing the oxygen and inhibiting the microbial activity necessary to catalyse mineral oxidation.

Environmental Monitoring↗

Comparative study on the selective chalcopyrite bioleaching of a molybdenite concentrate with mesophilic and thermophilic bacteria.

This study evaluates different bioleaching treatments of a molybdenite concentrate using mesophilic and thermophilic bacterial cultures. Further studies on the chemical leaching and the electrochemical behavior of the MoS(2) concentrate were carried out. Bioleaching tests showed a progressive removal of chalcopyrite from the molybdenite concentrate with an increase in temperature. Chemical leaching tests support the idea of an indirect attack of the concentrate. Electrochemical tests indicate that chalcopyrite dissolution is favored when molybdenite is present. Therefore, this type of bioleaching treatment could be applied to purify molybdenite flotation concentrates by selectively dissolving chalcopyrite.

Bacteria↗

Biosorption of copper and zinc by Cymodocea nodosa.

The adsorption of the two metal ions Cu and Zn in a single-component system by Cymodocea nodosa, a brown alga, under different pH conditions was investigated. The solution pH significantly affected the exhibited uptake, being maximum at a pH value of 4.5. Multi-component mixture biosorption in aqueous solutions is also reported. A comparison was made between the single-component saturation uptake and the multi-component uptakes. To evaluate the two-metal sorption system performance, simple isotherm curves had to be replaced by three-dimensional sorption isotherm surfaces. In order to describe the isotherm surfaces mathematically, three Langmuir-type models were evaluated. The isotherms indicate a competitive uptake with Cu being preferentially adsorbed. In addition, different tests were carried out to compare the process efficiency working continuously in small columns.

Adsorption↗

Biosorption with algae: a statistical review.

The state of the art in the field of biosorption using algae as biomass is reviewed. The available data of maximum sorption uptake (qmax) and biomass-metal affinity (b) for Cd2 +, Cu2 +, Ni2 +, Pb2 + and Zn2 + were statistically analyzed using 37 different algae (20 brown algae, 9 red algae and 8 green algae). Metal biosorption research with algae has used mainly brown algae in pursuit of treatments, which improve its sorption uptake. The information available in connection with multimetallic systems is very poor. Values of qmax were close to 1 mmol/g for copper and lead and smaller for the other metals. Metal recovery performance was worse for nickel and zinc, but the number of samples for zinc was very small. All the metals except lead present a similar affinity for brown algae. The difference in the behavior of lead may be due to a different uptake mechanism. Brown algae stand out as very good biosorbents of heavy metals. The best performer for metal biosorption is lead.

Adsorption↗