[2 pioneers of university anesthesiology].
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to M K Sykes.
Explore the source record for details and available documents.
Apnoeic oxygenation (AO) combined with extracorporeal CO2 removal (ECCO2R), using venovenous perfusion across a membrane area of 0.1 m2 has been shown to be feasible in six healthy anaesthetized rabbits. In a further twelve rabbits, ECCO2R has been randomly compared with conventional mechanical ventilation (CMV) following saline lavage to induce respiratory failure. Blood gases were maintained for up to 6 h within the same range (PaO2 = 8-20 kPa, PaCO2 = 4-6 kPa) in two groups of six by varying airway pressures and the oxygen fraction delivered either to the membrane lung (ECCO2R group) or to the ventilator (CMV group). The influence of single hourly sustained inflations (SI) on oxygenation was studied. ECCO2R subjects remained stable and survived. CMV subjects deteriorated and had 80% mortality. Hyaline membranes were absent from ECCO2R subjects and present in all CMV subjects. The response to SI suggests that a lung volume recruitment is maintained during AO for up to 1 h but is ineffective during CMV.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
This paper describes the development of a microprocessor controlled anaesthetic machine comprising an integrated anaesthetic apparatus and monitoring system. Following prolonged reliability trials in the laboratory, changes have been made to major components which were described in earlier publications.
Saline lavage of the lungs of eight anaesthetized New Zealand White rabbits was performed to produce a surfactant-depletion model of the neonatal respiratory distress syndrome. A characteristic change in the shape of the pressure-volume curve occurred, with the appearance of an inflection point on the inspiratory limb. The animals were treated with high frequency oscillation (HFO) at 15 Hz and the results compared with those of a previously studied group of eight similar rabbits treated with controlled mechanical ventilation (CMV) with end-expiratory pressure equal to the pressure at the inflection point, but with the same mean airway pressure of 15 mm Hg. The animals treated with HFO had significantly higher arterial oxygen tensions and end-expiratory lung volumes than those treated with CMV, but there was no significant difference between hyaline membrane scores. Although there was no significant difference in mean survival times, five of the HFO treated animals showed reversion of the shape of their pressure-volume curves towards the prelavage configuration, suggesting a recovery of surfactant function.
A new method has been developed to measure end-tidal carbon dioxide partial pressure (PECO2) during high frequency jet ventilation (HFJV). A digital flow controller incorporated in a computerized high frequency jet ventilator was used to deliver either a single deep breath or a series of three deep breaths. On user request, HFJV was interrupted and the deep breaths delivered, after which HFJV was resumed. Using a mathematical model, we were able to predict accurately the pressures to which the lungs would be inflated during deep breaths. The effect of varying the deep breath pressure (Pdb) on the ratio of end-tidal PCO2 to arterial (PCO2 (PECO2:PaCO2) was studied in three dogs. In all the dogs, within an optimum Pdb range of 5-10 cm H2O, PECO2 during the first deep breath was found to be similar (+/- 0.2 kPa) to the PaCO2 immediately before the onset of deep breaths. Deep breaths delivered above or below the optimum Pdb range resulted in a decrease in the ratio PECO2:PaCO2. The frequency of jet ventilation (12-200 b.p.m.) before the onset of the deep breaths did not affect PECO2:PaCO2.
Explore the source record for details and available documents.
Sixteen rabbits were anaesthetized and subjected to saline lavage of the lungs to produce surfactant deficiency. This resulted in an arterial oxygen tension of less than 12 kPa on 100% inspired oxygen and an inflection point on the pressure-volume curve at a pressure of 8-12 mmHg. After lavage the animals were randomly assigned to receive either conventional mechanical ventilation (CMV) with a positive end-expiratory pressure (PEEP) of 1-2 mmHg (group I - low PEEP) or CMV with PEEP equal to the inflection point pressure (group II - high PEEP). Mean airway pressures were kept at 14-16 mmHg in both groups by increasing the inspiratory:expiratory time ratios in the low PEEP group. The 5-h protocol was completed by 4 animals in group I and 6 animals in group II, early death usually being associated with a metabolic acidosis. On 100% oxygen, the mean PaO2 at 2-h post-lavage was 15.2 +/- 8.3 kPa in group I and 39.6 +/- 21.8 kPa in group II. Group I had much lower end-expiratory lung volumes (3.0 +/- 1.5 ml above FRC) than group II (34.9 +/- 12.2 ml above FRC). Histological examination of the lungs revealed significantly less hyaline membrane formation in group II (p = 0.001). Thus, the prevention of alveolar collapse by the use of high PEEP levels appears to reduce lung damage in this preparation.
Electromagnetic flow probes were used to measure the fraction of the pulmonary blood flow perfusing the left lower lobe (Ql/Qt) in 16 anaesthetized, open-chest dogs in order to study the effects of right lung airway pressure on the distribution of blood flow to a hypoxic lung lobe. Ventilation of the lobe with 7% oxygen in nitrogen resulted in a 37% reduction in Ql/Qt at the beginning and end of the main procedure, thus confirming that the hypoxic pulmonary vasoconstrictor response was unchanged throughout the study. The effects of varying mean airway pressure to the right lung by changing inspiratory:expiratory time ratio and by the addition of a positive end-expiratory pressure were studied when the left lower lobe was insufflated with oxygen or 7% oxygen in nitrogen, or was collapsed. Insufflation of the lobe with 7% oxygen in nitrogen and collapse reduced Ql/Qt by 61% and 66%, respectively. However, changing mean airway pressure in the right lung produced no significant changes in Ql/Qt in any of the different lobar conditions or when collapse was produced after fluid loading. Fluid loading during collapse increased cardiac output and pulmonary vascular pressures and increased Ql/Qt to a value which was not significantly different from lobar ventilation with 7% oxygen in nitrogen. It is concluded that moderate increases in mean airway pressure do not increase Ql/Qt when this has been reduced by exposure of the lobe to mixed venous blood-gas tensions.
Right-to-left shunt (Qs/Qt) was measured by the SF6 and oxygen methods in 13 anaesthetized closed-chest dogs intubated with a double-lumen endobronchial tube. Collapse of the left lung increased Qs/Qt from 10% to 23%, suggesting that blood flow to the left lung had been reduced by about 60%. Increasing right lung mean airway pressure by the alteration of the inspiratory:expiratory time ratio or the application of PEEP produced a small but non-significant increase in Qs/Qt with significant increases in arterial and mixed venous carbon dioxide tensions, and arterial to right lung end-tidal carbon dioxide tension difference. Fluid loading during collapse increased cardiac output and pulmonary vascular pressures, but Qs/Qt did not differ significantly from the normovolaemic collapsed state. Increasing the right mean airway pressure in this condition had no effect on Qs/Qt or carbon dioxide tensions.
Electromagnetic flow probes were placed around the pulmonary artery and left lower lobe artery in anaesthetized open-chest dogs in order to measure possible changes in the ratio of lobar-to-total pulmonary blood flow (Ql/Qt) in response to changes in cardiac output produced by the opening of arterio-venous fistulae or fluid loading. Ventilation of the lobe with 7% oxygen or lobar collapse reduced Ql/Qt by 35% and 42%, respectively, but there were no significant changes in Ql/Qt in response to increases in Qt of 29-133%. It is concluded that the changes in Qt, pulmonary vascular pressures and mixed venous PO2 within the range studied did not influence Ql/Qt.
A new method has been developed to measure tidal volume during high frequency jet ventilation. A pneumotachograph is placed in the expiratory limb of the breathing circuit. Using a model lung, the results from this method did not differ from the tidal volume calculated from pressure changes measured within the model lung. The results from the two methods correlated well (r = 0.99). The method enables the gas volumes entrained and spilled out of the airway during inspiration, true I:E ratios and mean driving pressures to be determined. The method is non-invasive and could easily be applied clinically.
A laboratory investigation was carried out to evaluate the performance of the Datex Capnomac multigas anaesthetic agent analyser, with particular emphasis on accuracy, response and delay times, zero and gain stability and interference from water vapour. The analysis of anaesthetic vapours was less accurate than the analysis of CO2, O2 and N2O, but acceptable for clinical use. The response to square wave changes in gas composition was accurate at frequencies up to 60 per minute for CO2 and 30 per minute for O2, but with N2O and the anaesthetic vapours there was a decrease in accuracy at frequencies above 20 breaths/minute. The instrument appeared to be unaffected by water vapour.
Explore the source record for details and available documents.
One essayist suggests that continuous monitoring of alveolar and inspiratory concentrations of anesthetic and respiratory gases has little or no positive effect on patient outcome and may even be detrimental to patients. Such monitoring, he says, tends to remove anesthesiologists from personal contact with their patients. He recommends careful monitoring of fresh gas concentrations leaving the anesthetic machine, careful monitoring of inspired gas in a circle absorption breathing system, and improved training of anesthesiologists to prevent human error. Another essayist suggests that continuous monitoring of alveolar and inspiratory concentrations of anesthetic and respiratory gases is cost-effective and relatively simple. He says that such monitoring, without being a source of legal problems for its users, improves the quality of patient care.