M Jerosch-Herold

Publications and source records attributed to M Jerosch-Herold.

At least 19 recordsLinked to original sources

Echo-planar magnetic resonance myocardial perfusion imaging: parametric map analysis and comparison with thallium SPECT.

Magnetic resonance (MR) perfusion FLASH imaging has been used for assessing coronary artery disease (CAD). Echo-planar MR techniques have advantages in speed and in making MR perfusion imaging results more clinically accessible through parametric maps, but have not been previously assessed. We implemented a spin-echo, echo-planar MR technique and applied it at rest and during adenosine stress in 26 patients with CAD and abnormal thallium single-photon-emission computed tomography (SPECT), and analyzed the results by using a newly developed parametric map analysis of time to peak, peak intensity, and slope of contrast washin. The results were compared with the results of conventional visual analysis of the perfusion cine series. For detecting abnormal coronary territories, MR and SPECT were comparable for sensitivity, specificity, and accuracy (thallium, 70%, 78%, and 73%; MR, 79% 83%, and 80%; P = NS). There was good agreement between thallium and MR during stress (kappa = 0.49), but defects were larger by MR (2.4 vs. 3.1 segments for slope; P < 0.01). Additional segments were detected at rest by MR (58 for slope vs. 25 for thallium), which correlated with areas that became abnormal with stress in the thallium (sensitivity, 100%; specificity, 63%). The parametric maps were easier and faster to interpret than review of the original first-pass series of images (chi2 = 10.8; P < 0.04). The diagnostic performance of echo-planar perfusion MR and SPECT was similar, and combining the results with parametric mapping was useful for interpretation and considerably improved data display for clinical interpretation. MR, however, was faster and yielded images of higher resolution with no radiation burden. In multislice mode, these new MR techniques may have clinical value.

Aged↗

Quantitative magnetic resonance first-pass perfusion analysis: inter- and intraobserver agreement.

Magnetic resonance first-pass (MRFP) imaging awaits longitudinal clinical trials for quantification of myocardial perfusion. The purpose of this study was to assess inter- and intraobserver agreement of this method. Seventeen MRFP studies (14 rest and 3 under adenosine-induced hyperemia) from 14 patients were acquired. Two observers visually graded study quality. Each study was subdivided into eight regions. Both observers analyzed all 17 studies (8 x 17 = 136 regions) for interobserver agreement. Each observer then analyzed 10 of the 17 studies a second time (2 x 8 x 10 = 160 regions) for intraobserver agreement. Signal intensity curves were obtained with Argus software (Siemens, Iselin, NJ). The maximum amplitude of the impulse response function (Rmax) and the change of signal intensity (deltaSImax) of the contrast bolus were determined. Intraclass correlation coefficient was used to determine intra- and interobserver agreement. The quality was good or excellent in 14 studies. Intraobserver agreement of Rmax and deltaSImax were good (0.85 and 0.80, n = 160). Interobserver agreement of Rmax was fair (0.55, n = 136) but improved after exclusion of poor-quality studies (0.88, n = 112). Interobserver agreement of deltaSImax was good (0.73) and improved less than Rmax with study quality (0.83). Interobserver agreement for Rmax in individual myocardial regions before and after exclusion of studies with poor quality changed most markedly in lateral and posterior regions (0.69 and 0.65 vs. 0.97 and 0.94), where signal-to-noise ratios were reduced compared with anteroseptal regions (p < 0.01). Analysis of MRFP images provides good intraobserver agreement. Interobserver agreement of the quantitative perfusion analysis is good under the premise of good image quality.

Adult↗

Variability in the cardiac EIT image as a function of electrode position, lung volume and body position.

A study was conducted using the Sheffield electrical impedance tomography (EIT) portable system DAS-01 P to determine the change in the cardiac image with electrode position, lung volume and body position. Sixteen electrodes were positioned in three transverse planes around the thorax at the level of the second intercostal space, at the level of the xiphisternal joint, and midway between upper and lower locations. Data were collected at each electrode level with the breath held at end expiration and after inspiring 0.5, 1 and 1.5 l of air with the subject in both the supine and sitting position. These data were analysed using a Matlab developed program that calculates the average resistivity change in the cardiac region from automatically determined borders. Results show significant individual variability with electrode position and air volume. The middle electrode most consistently shows an increase in impedance in the region of the heart during systole. In some subjects the change in the ventricular-volume-like curve showed a greater than 50% change as a function of lung volume. The pattern of variability with electrode position was not consistent among subjects. In one subject MRI images were obtained to compare actual structures with those seen in the EIT image. The results suggest that using these electrode locations reliable and consistent data, which could be used in clinical applications, cannot be obtained.

Electric Impedance↗

Magnetic resonance imaging of myocardial perfusion in single-vessel coronary artery disease: implications for transmural assessment of myocardial perfusion.

The purpose of the study was to investigate the potential of magnetic resonance imaging (MRI) to assess transmural differences in myocardial perfusion. Contrast-enhanced MRI was performed at rest and during hyperemia in a dog model and in 22 patients with single-vessel coronary artery disease. From MR signal intensity-versus-time curves, three perfusion parameters were derived: maximum myocardial contrast enhancement (MCE), slope, and inverse mean transit time (1/MTT). In dogs, MCE correlated well (r = 0.87, p < 0.00001) with microsphere-assessed myocardial blood flow. In the patients, the subendocardial MCE decreased during hyperemia (0.89 +/- 0.18 vs. 0.74 +/- 0.15, p < 0.003) and was lower in subendocardium than in subepicardium (0.74 +/- 0.15 vs. 0.84 +/- 0.21, p < 0.02). Parameters slope and 1/MTT paralleled MCE. Contrast-enhanced MRI reflects the transmural redistribution of myocardial perfusion during hyperemia. Perfusion abnormalities can be identified most distinctly in subendocardial myocardium.

Adult↗

Myocardial oxygenation during high work states in hearts with postinfarction remodeling.

BACKGROUND: Postinfarction left ventricular remodeling (LVR) is associated with reductions in myocardial high-energy phosphate (HEP) levels, which are more severe in animals that develop overt congestive heart failure (CHF). During high work states, further HEP loss occurs, which suggests demand-induced ischemia. This study tested the hypothesis that inadequate myocyte oxygen availability is the basis for these HEP abnormalities. METHODS AND RESULTS: Myocardial infarction was produced by left circumflex coronary artery ligation in swine. Studies were performed in 20 normal animals, 14 animals with compensated LVR, and 9 animals with CHF. Phosphocreatine (PCr)/ATP was determined with 31P NMR and deoxymyoglobin (Mb-delta) with 1H NMR in myocardium remote from the infarct. Basal PCr/ATP tended to be decreased in postinfarct hearts, and this was significant in animals with CHF. Infusion of dobutamine (20 microg x kg-1 x min-1 IV) caused doubling of the rate-pressure product in both normal and LVR hearts and resulted in comparable significant decreases of PCr/ATP in both groups. This decrease in PCr/ATP was not associated with detectable Mb-delta. In CHF hearts, rate-pressure product increased only 40% in response to dobutamine; this attenuated response also was not associated with detectable Mb-delta. CONCLUSIONS: Thus, the decrease of PCr/ATP during dobutamine infusion is not the result of insufficient myocardial oxygen availability. Furthermore, in CHF hearts, the low basal PCr/ATP and the attenuated response to dobutamine occurred in the absence of myocardial hypoxia, indicating that the HEP and contractile abnormalities were not the result of insufficient oxygen availability.

Adenosine Triphosphate↗

Magnetic resonance first-pass myocardial perfusion imaging: clinical validation and future applications.

Clinical studies suggest that magnetic resonance first-pass (MRFP) perfusion imaging is comparable to current diagnostic tests that are used clinically for the assessment of myocardial perfusion. In addition, magnetic resonance imaging (MRI) perfusion imaging is a noninvasive method for determining myocardial blood flow. The spatial resolution (in-plane spatial resolution < 3 mm) is sufficient to differentiate between subendocardial perfusion and subepicardial perfusion. The measurement can be repeated regularly without any adverse effects for the patient. MRI perfusion measurements can be combined with the evaluation of global function and regional wall thickening. Currently, there is no other imaging technique that offers similar advantages. The MRI perfusion measurements can be carried out during baseline conditions and during maximal hyperemia induced with either adenosine or dipyridamole. The ratio of the measured myocardial blood flows provides an estimate of the absolute and relative myocardial perfusion reserve. The perfusion reserve determined with MRFP imaging is a quantitative measure for the assessment of the collateral-dependent myocardial flow. Based on the available data using MRFP perfusion imaging, the current clinical first-line perfusion imaging tests are going to be challenged in the near future. J. Magn. Reson. Imaging 1999;10:676-685.

Coronary Circulation↗

Myocardial viability.

This article reviews various means to assess myocardial viability by imaging, and provides recommendations for current clinical practice. This article also discusses future directions in assessing myocardial viability.

Contrast Media↗

The seismocardiogram as magnetic-field-compatible alternative to the electrocardiogram for cardiac stress monitoring.

Seismocardiography (SCG) is a methodology derived from the field of seismology to measure non-invasively compression waves generated by myocardial motion. The use of SCG is proposed here as method to monitor cardiac function during stress testing and magnetic resonance imaging (MRI). It is shown that recording of the seismocardiogram in subjects undergoing an MRI study is not compromised by flow-induced electrical voltages that can severely distort the electrocardiogram. Electromagnetic compatibility of the seismocardiograph device with the MRI scanner hardware was tested. Experiments in an animal model proved that changes in the SCG waveform during different levels of LAD stenosis correlate with the changes seen in LV function with cine MRI. The changes in the SCG waveform characteristic for the onset of ischemia were observed almost immediately after the creation of a flow-limiting stenosis. This novel application of SCG to monitor changes in peak acceleration from cardiac blood flow and wall motion may represent a solution to the long-standing and important problem of monitoring patients for signs of myocardial ischemia during MRI.

Coronary Circulation↗

Direct comparison of an intravascular and an extracellular contrast agent for quantification of myocardial perfusion. Cardiac MRI Group.

A direct comparison of extracellular and intravascular contrast agents for the assessment of myocardial perfusion was carried out in a porcine model (N = 5) with a flow-limiting occluder on the left anterior descending coronary artery. Rapid imaging during the first pass of an extracellular or intravascular contrast agent with a saturation-recovery-prepared TurboFLASH sequence showed comparable peak contrast-to-noise enhancements in myocardial tissue regions with flows averaging 1.1 +/- 0.2 at baseline to 4.8 +/- 0.6 ml/min/g during hyperemia. The coefficient of variation between the MR estimates of blood flow with Gadomer-17 and the microsphere blood flow measurements was 11 +/- 11%, while the corresponding co-efficient of variation for blood flow estimates with the extracellular CA was 23 +/- 11%. Blood volume differences between rest and hyperemia observed with the intravascular tracer were significant (Vvasc(rest) = 0.078 +/- 0.013 ml/g, versus Vvasc(hyperemia) = 0.102 +/- 0.019 ml/g; p < 0.05). The effects of water exchange were minimized through the choice of pulse sequence parameters to provide blood volume estimates consistent with the changes expected between rest and hyperemia. This study represents the first application of multiple indicators in first pass imaging studies for the assessment of myocardial perfusion. The use of an intravascular instead of an extracellular contrast agent allows a reduction of the degrees of freedom for modeling tissue residue curves and results in improved accuracy of blood flow estimates.

Animals↗

Assessing myocardial perfusion in coronary artery disease with magnetic resonance first-pass imaging.

MRFP perfusion imaging can now be used clinically on most MR scanner systems (1.0 to 1.5 T). The current experimental data demonstrate that MRFP imaging allows the quantitative assessment of myocardial blood flow changes and accurate measurements of collateral flow, including changes in the collateral dependent zones. Certain protocols, however, as outlined here have to be followed to obtain all the possible diagnostic information. Based on the current data on MRFP imaging, it is realistic to anticipate that MRFP imaging in combination with cine or tagging MR imaging will provide clinicians with better methods to distinguish stunned and hibernating, from nonviable myocardium and obtain better outcome data. Dedicated MR scanners are now being designed to meet the needs for MR imaging of patients with coronary artery disease. These scanners, small in size and with better patient access, make placement near the coronary care unit or catheterization laboratory feasible. This is a major step toward enhancing the utility of this new technique by providing the necessary infrastructure for scanning large numbers of patients. The main obstacle to wider use of these new diagnostic tools to assess perfusion is the lack of a large clinical database because there have not yet been major multicenter trials. With the development of novel intravascular contrast agents, however, larger trials are planned that should provide the clinical data mandatory for full integration of MRFP imaging into clinical practice. In particular, the development of dedicated and user-friendly perfusion analysis software will create the means to evaluate MR perfusion data accurately in large patient populations. These studies need to be conducted in a collaborative fashion by cardiologists, heart surgeons, and radiologists to be fully accepted by health care providers in an increasingly cost-averse and competitive health care environment.

Coronary Disease↗

Magnetic resonance quantification of the myocardial perfusion reserve with a Fermi function model for constrained deconvolution.

The myocardial perfusion reserve, defined as the ratio of hyperemic and basal myocardial blood flow, is a useful indicator of the functional significance of a coronary artery lesion. Rapid magnetic resonance (MR) imaging for the noninvasive detection of a bolus-injected contrast agent as a MR tracer is applied to the measurement of regional tissue perfusion during rest and hyperemia, in patients with microvascular dysfunction. A Fermi function model for the distribution of tracer residence times in the myocardium is used to fit the MR signal curves. The myocardial perfusion reserve is calculated from the impulse response amplitudes for rest and hyperemia. The assumptions of the model are tested with Monte Carlo simulations, using a multiple path, axially distributed mathematical model of blood tissue exchange, which allows for systematic variation of blood flow, vascular volume, and capillary permeability. For a contrast-to-noise ratio of 6:1, and over a range of flows from 0.5 to 4.0 ml/min per g of tissue, the ratio of the impulse response amplitudes for hyperemic and basal flows is linearly proportional to the ratio of model blood flows, if the mean transit time of the input function is shorter than approximately 9 s. The uncertainty in the blood flow reserve estimates grows both at low (< 1.0 ml/min/g) and high (> 3-4 ml/min/g) flows. The predictions of the Monte Carlo simulations agree with the results of MR first pass studies in patients without significant coronary artery lesions and microvascular dysfunction, where the perfusion reserve in the territory of the left anterior descending coronary artery (LAD) correlates linearly with the intracoronary Doppler ultrasound flow reserve in the LAD (r = 0.84), in agreement with previous PET studies.

Capillaries↗

MR first pass imaging: quantitative assessment of transmural perfusion and collateral flow.

Recent advances with fast switching gradient coils, and the optimization of magnetic resonance techniques for multislice imaging have made it possible to apply models of contrast agent transit for the quantification of myocardial perfusion, and determination of the transmural distribution of blood flow. This article summarizes some of these recent developments and presents examples of quantitative, multi-slice myocardial perfusion imaging studies in patients and animal models. Multi-slice, true first pass imaging, with high temporal resolution, and T1-weighted, arrhythmia insensitive contrast enhancement is used for the quantification of perfusion changes accompanying mild to severe ischemia. The first pass imaging technique and the modeling approach are sufficiently robust for fitting of tissue residue curves corresponding to a wide, physiologically realistic range of myocardial blood flows. In animals this was validated by comparison to blood flow measurements with radiolabeled microspheres as gold standard. It is demonstrated that with the proposed modeling approach one can determine the myocardial perfusion reserve from two consecutive MR first pass measurements under resting and hyperemic conditions. In patients with microvascular dysfunction the MR studies show for the first time that the myocardial perfusion reserve correlates with Doppler flow measurements (linear regression with slope of 1.02 +/- 0.09; r = 0.80). Since perfusion limitations usually begin in the subendocardium as coronary flow is gradually reduced, first pass imaging with the prerequisitie spatial and temporal resolution allows early detection of a mild coronary stenosis.

Animals↗

Myocardial perfusion reserve: assessment with multisection, quantitative, first-pass MR imaging.

PURPOSE: To demonstrate the feasibility of determining myocardial blood flow changes and the myocardial perfusion reserve with magnetic resonance (MR) first-pass imaging, to validate the MR results by means of comparison with radiolabeled microsphere flow measurements in an animal model, and to compare the coronary flow reserve with the perfusion reserve at MR imaging in patients with hemodynamically nonsignificant coronary lesions and angina. MATERIALS AND METHODS: Arrhythmia-insensitive, first-pass, multisection, T1-weighted MR imaging with contrast agent enhancement was performed in eight pigs with acute ischemia and in eight adult patients (six women, two men). In the pigs, microsphere flow measurements were obtained in parallel with the MR measurements. In the patients, the coronary flow reserve was measured with an intracoronary Doppler flow ultrasound probe for comparison with the MR perfusion reserve. RESULTS: In the animal studies, there was linear correlation between MR perfusion indexes and the microsphere flow measurements (r = .88, P < .01). In the patients, the regional perfusion reserve matched the coronary flow reserve (linear regression with a slope of 1.02 +/- 0.09, r = .80). CONCLUSION: The myocardial perfusion reserve can be quantified with first-pass MR imaging. In patients with microvascular dysfunction, the myocardial perfusion reserve matches the reduced coronary flow reserve.

Animals↗

Myocardial perfusion and function in dogs with moderate coronary stenosis.

MRI studies of first-pass contrast enhancement with polylysine-Gd-DTPA and myocardial tagging using spatial modulation of magnetization (SPAMM) were performed to assess the feasibility of a combined regional myocardial blood flow and 2D deformation exam. Instrumented closed-chest dogs were imaged at a baseline control state (Cntl) followed by two interventions: moderate coronary stenosis (St) achieved by partial occlusion of the left anterior descending (LAD) and moderate coronary stenosis with dobutamine loading (StD). Hypoperfusion of the anterior region (ANT) of the myocardium (LAD distribution) relative to the posterior wall (POS) based on the upslope of the signal intensity time curve from the contrast-enhanced MR images was demonstrated only with dobutamine loading (ANT:POS Cntl = 1.077 +/- 0.15 versus ANT:POS StD = 0.477 +/- 0.11, P < 0.03) and was confirmed with radiolabeled microspheres measurements (ANT:POS Cntl = 1.18 +/- 0.2 ml/min/g versus ANT:POS StD = 0.44 +/- 0.1 ml/min/g; P < 0.002). Significant changes in regional myocardial shortening were only seen in the StD state (P < 0.02); the anterior region showed impaired myocardial shortening with dobutamine loading (P = NS), whereas the nonaffected POS region showed a marked increase in shortening when compared with Cntl (Cntl = 0.964 +/- 0.02 versus StD = 0.884 +/- 0.03; P < 0.001). These results demonstrate that an integrated quantitative assessment of regional myocardial function and semiquantitative assessment of myocardial blood flow can be performed noninvasively with ultrafast MRI.

Animals↗

Modeling regional myocardial flows from residue functions of an intravascular indicator.

The purpose of the present study was to determine the accuracy and the sources of error in estimating regional myocardial blood flow and vascular volume from experimental residue functions obtained by external imaging of an intravascular indicator. For the analysis, a spatially distributed mathematical model was used that describes transport through a multiple-pathway vascular system. Reliability of the parameter estimates was tested by using sensitivity function analysis and by analyzing "pseudodata": realistic model solutions to which random noise was added. Increased uncertainty in the estimates of flow in the pseudodata was observed when flow was near maximal physiological values, when dispersion of the vascular input was more than twice the dispersion of the microvascular system for an impulse input, and when the sampling frequency was < 2 samples/s. Estimates of regional blood volume were more reliable than estimates of flow. Failure to account for normal flow heterogeneity caused systematic underestimates of flow. To illustrate the method used for estimating regional flow, magnetic resonance imaging was used to obtain myocardial residue functions after left atrial injections of polylysine-Gd-diethylenetriaminepentaacetic acid, an intravascular contrast agent, in anesthetized chronically instrumental dogs. To test the increase in dispersion of the vascular input after central venous injections, magnetic resonance imaging data obtained in human subjects were compared with left ventricular blood pool curves obtained in dogs. It is concluded that if coronary flow is in the normal range, when the vascular input is a short bolus, and the heart is imaged at least once per cardiac cycle, then regional myocardial blood flow and vascular volume may be reliably estimated by analyzing residue functions of an intravascular indicator, providing a noninvasive approach with potential clinical application.

Animals↗

Fast anatomical imaging of the heart and assessment of myocardial perfusion with arrhythmia insensitive magnetization preparation.

A new contrast preparation based on modified driven equilibrium Fourier transfer is introduced and evaluated for generation of T1-weighted images for assessment of the myocardial perfusion with contrast agent first-pass kinetics. The new preparation scheme produces T1 contrast with insensitivity to arrhythmias in prospectively triggered sequential imaging thereby eliminating one of the major sources of problems in potential patient studies with previously employed contrast preparations schemes.

Algorithms↗