Mammographic densities and breast cancer risk.

Variations between individuals in the radiographic appearance, or mammographic pattern, of the female breast arise because of differences in the relative amounts and X-ray attenuation characteristics of fat and connective and epithelial tissue. Studies using quantitative methods of assessment have consistently shown these variations to be strongly related to risk of breast cancer. Individuals with extensive areas of radiologically dense breast tissue on the mammogram have been found to have a risk of breast cancer that is four to six times higher than women with little or no density. In this paper, we propose a model for the relationship of mammographic densities to risk of breast cancer. We propose that the risk of breast cancer associated with mammographically dense breast tissue is due to the combined effects of two processes: cell proliferation (mitogenesis), induced by growth factors and sex hormones and influenced by reproductive risk factors for breast cancer; and damage to the DNA of dividing cells (mutagenesis) by mutagens generated by lipid peroxidation. We review the evidence that each of these processes is associated with mammographic densities and propose further work that we believe should be done to clarify these relationships.

Journal Article↗

Developing and supporting school health programs. Role for family physicians.

PROBLEM BEING ADDRESSED: School staff are anxious about the demands on their time associated with a perceived increase in health problems among their students. OBJECTIVE OF PROGRAM: To respond to these concerns by developing a health committee in two elementary schools and one high school. The health committee could perform needs assessments and, with the results of these assessments and a careful literature review, could develop health policies and procedures appropriate to the school environment and to evolving community expectations. MAIN COMPONENTS OF PROGRAM: A committee of four family physicians (nonremunerated parents of students), one of whom served as Chair, four school administrators, and one part-time remunerated nurse practitioner explored aspects of illness in the schools. They studied approaches to acute and chronic student illness; emergency response; management of children with special needs; environmental safety; health promotion; and the availability and quality of resources for learning about health for teachers, administrators, parents, and students. CONCLUSION: Opportunities exist for family physicians to expand their involvement in child and adolescent health in schools. Involvement should be collaborative and multidisciplinary and reflect community interests and needs.

Emergency Treatment↗

Mammographic densities and breast cancer risk.

The radiological appearance of the female breast varies among individuals because of differences in the relative amounts and X-ray attenuation characteristics of fat and epithelial and stromal tissues. Fat is radiolucent and appears dark on a mammogram, and epithelium and stroma are radiodense and appear light. We review here the evidence that these variations, known as mammographic parenchymal patterns, are related to risk of breast cancer. Studies that used quantitative measurement to classify mammographic patterns have consistently found that women with dense tissue in more than 60-75% of the breast are at four to six times greater risk of breast cancer than those with no densities. These risk estimates are independent of the effects of other risk factors and have been shown to persist over at least 10 years of follow up. Estimates of attributable risk suggest that this risk factor may account for as many as 30% of breast cancer cases. Mammographically dense breast tissue is associated both with epithelial proliferation and with stromal fibrosis. The relationship between these histological features and risk of breast cancer may by explained by the known actions of growth factors that are thought to play important roles in breast development and carcinogenesis. Mammographically dense tissue differs from most other breast cancer risk factors in the strength of the associated relative and attributable risks for breast cancer, and because it can be changed by hormonal and dietary interventions. This risk factor may be most useful as a means of investigating the etiology of breast cancer and of testing hypotheses about potential preventive strategies.

Breast↗

Automated analysis of mammographic densities and breast carcinoma risk.

BACKGROUND: There is considerable evidence that one of the strongest risk factors for breast carcinoma can be assessed from the mammographic appearance of the breast. However, the magnitude of the risk factor and the reliability of the prediction depend on the method of classification. Subjective classification requires specialized observer training and suffers from inter- and intraobserver variability. Furthermore, the categoric scales make it difficult to distinguish small differences in mammographic appearance. To address these limitations, automated analysis techniques that characterize mammographic density on a continuous scale have been considered, but as yet, these have been evaluated only for their ability to reproduce subjective classifications of mammographic parenchyma. METHODS: In this study, using a nested case-control design, the authors evaluated the direct association between breast carcinoma risk and quantitative image features derived from automated analysis of digitized film mammograms. Two parameters, one describing the distribution of breast tissue density as reflected by brightness of the mammogram (regional skewness) and the other characterizing texture (fractal dimension), were calculated for images from 708 subjects identified from the Canadian National Breast Screening Study. RESULTS: These parameters were evaluated for their ability to distinguish cases (those women who developed breast carcinoma) from controls. It was found that both the skewness and fractal parameters were significantly related to risk of developing breast carcinoma. CONCLUSIONS: Although the relative risk estimates were moderate (typically > 2.0) and less than those from subjective classification or for an interactive computer method the authors have previously described, they are comparable to other risk factors for the disease. The observer independence and reproducibility of the automated methods may facilitate their more widespread use.

Adult↗

X-ray detectors for digital radiography.

Digital radiography offers the potential of improved image quality as well as providing opportunities for advances in medical image management, computer-aided diagnosis and teleradiology. Image quality is intimately linked to the precise and accurate acquisition of information from the x-ray beam transmitted by the patient, i.e. to the performance of the x-ray detector. Detectors for digital radiography must meet the needs of the specific radiological procedure where they will be used. Key parameters are spatial resolution, uniformity of response, contrast sensitivity, dynamic range, acquisition speed and frame rate. The underlying physical considerations defining the performance of x-ray detectors for radiography will be reviewed. Some of the more promising existing and experimental detector technologies which may be suitable for digital radiography will be considered. Devices that can be employed in full-area detectors and also those more appropriate for scanning x-ray systems will be discussed. These include various approaches based on phosphor x-ray converters, where light quanta are produced as an intermediate stage, as well as direct x-ray-to-charge conversion materials such as zinc cadmium telluride, amorphous selenium and crystalline silicon.

Electrons↗

Thickness-equalization processing for mammographic images.

A digital postprocessing technique was used to compensate for the limitations of laser film or cathode-ray-tube devices used to display digital mammograms. An algorithm identified and equalized for the large change in digital signal caused by the reduction in thickness at the margin of the compressed breast. The resulting images reflected only breast composition, and so the number of gray levels needed to display the processed image was greatly reduced, which facilitated presentation and analysis.

Female↗

Variations in measured vessel diameters using coronary measurement system.

The Coronary Measurement System (CMS, MEDIS, Leiden, Netherlands) is a film-based QCA system that allows the user to vary the intensity of the light source which illuminates the film, thereby changing the brightness of the image viewed by the digitizing video camera. We found that significant variations in calibration factor (mm/pixel) and measured diameter can occur as a result of variations in either of these intensities. We calculated the variability of the measured diameters for a range of light intensities used for vessel measurement and for calibration. The root mean square deviations in estimated vessel diameter for simulated vessels having actual diameters of 2.03, 2.56, 3.03, and 3.55 mm were 0.13, 0.13, 0.13, and 0.11 mm, respectively, while the ranges (maximum-minimum estimates) were 0.47, 0.45, 0.47, and 0.36 mm, respectively. These results show that while mean errors due to changes in brightness are small, there is the potential for larger errors for certain combinations of light intensities.

Coronary Angiography↗

Current status of digital mammography.

Some inherent limitations to further technical improvement in film-screen mammography exist. Many of these limitations can be overcome effectively with digital mammography, in which image acquisition, display, and storage are performed independently, thus allowing the optimization of each. Presented is a brief background of digital and analog imaging with emphasis on the features and drawbacks of digital mammography systems. Image storage, processing, and display, computer-aided detection and diagnosis, as well as telemammography are also discussed.

Diagnosis, Computer-Assisted↗

Quantitative correlation of breast tissue parameters using magnetic resonance and X-ray mammography.

Previous investigators have shown that there is a strong association between the fraction of fibroglandular tissue within the breast as determined by X-ray mammography (per cent density) and breast cancer risk. In this study, the quantitative correlation between per cent density and two objective magnetic resonance (MR) parameters of breast tissue, relative water content and mean T2 relaxation time, as investigated for 42 asymptomatic subjects. Using newly developed, rapid techniques MR measurements were performed on a volume-of-interest incorporating equal, representative portions of both breasts. X-ray mammograms of each subject were digitised and analysed semiautomatically to determine per cent density. Relative water content showed a strong positive correlation with per cent density (Pearson correlation coefficient rp = 0.79, P < 0.0001) and mean T2 value showed a strong negative correlation with per cent density (rp = -0.61, P < 0.0001). The MR and X-ray parameters were also associated with sociodemographic and anthropometric risk factors for breast cancer (P < 0.05). The potential use of MR parameters to assess risk of breast cancer and to provide a frequent, non-hazardous monitor of breast parenchyma is discussed.

Adipose Tissue↗

Analysis of signal propagation in optically coupled detectors for digital mammography: II. Lens and fibre optics.

An x-ray detector for digital x-ray mammography is under investigation, which consists of a phosphor screen coupled by a demagnifying fibre-optic taper to a time-delay integration mode, charge-coupled device (CCD) image array. The signal propagation through such a detector depends on the intensity and angular emission of light from the phosphor screen, the angular acceptance and transmission of light through the optics, and the spectral sensitivity of the CCD to the fluorescent light. The production of light by the phosphor screen was considered in a previous paper. Here, the issues related to the optics are examined. For phosphor screens coupled by lenses with limiting acceptance angles of less than 30 degrees, it was calculated that the coupling efficiency would be 10% greater than would be estimated under the assumption of a Lambertian source. These increases occur because a phosphor screen typically produces light which is more forward directed than a Lambertian source. Similar increases in efficiency are observed when a phosphor screen is coupled to a fibre-optic faceplate or taper. For fibre optics, exact estimation of the optical coupling efficiency requires knowledge of the angular-dependent transmission efficiency of the fibres.

Biophysical Phenomena↗

Automated analysis of mammographic densities.

Information derived from mammographic parenchymal patterns provides one of the strongest indicators of the risk of developing breast cancer. To address several limitations of subjective classification of mammographic parenchyma into coarse density categories, we have been investigating more quantitative, objective methods of analysing the film-screen mammogram. These include measures of the skewness of the image brightness histogram, and of image texture characterized by the fractal dimension. Both measures were found to be strongly correlated with radiologists' subjective classifications of mammographic parenchyma (Spearman correlation coefficients, Rs = -0.88 and -0.76 for skewness and fractal dimension measurements, respectively). Further, neither measure was strongly dependent on simulated changes in mammographic technique. Correlation with subjective classification of mammographic density was better when both the skewness and fractal measures were used in combination than when either was used alone. This suggests that each feature provides some independent information.

Adult↗

Computed tomography artifacts associated with craniofacial fixation devices: an experimental study.

This study compares the artifacts caused by eight different craniofacial fixation devices in computed tomography (CT) images. Using a Teflon CT phantom model, part I of this study involved the quantitative evaluation of the X-ray absorption properties of each fixation device. Part II utilized a human cadaveric model to determine the degree to which the artifact interfered with the visualization of anatomic structures. In part I, each fixation device was secured to the surface of the phantom and then scanned. All artifacts were compared on the basis of standard deviation in CT number. The severity of the artifact was related to the physical size of the fixation device and its composition. Vitallium devices generated a greater degree of CT artifacts than titanium devices of comparable size. In part II, fixation devices were secured to the orbital rims of human cadaveric heads and then scanned. Visualization of specified anatomic structures was graded independently. The results revealed that titanium fixation devices did not cause significant bone or soft-tissue image degradation, whereas all vitallium fixation devices, except micro mesh and micro (1.0 mm) straight plates, generated an artifact that resulted in some image degradation. The extent of image degradation was related to the fixation device size. Only the thickest vitallium fixation device, mini fragmentation (2.0 mm), resulted in bony image degradation. The degree of soft-tissue image degradation decreased as the size of vitallium fixation devices decreased such that micro fragmentation (0.8 mm) and pan fixation (1.3 mm) devices interfered with soft-tissue visualization only in the immediate vicinity of the plate. The results of this study confirm the previous work of Sullivan and colleagues and Fiala and associates. The data indicate that when postoperative imaging is an important clinical consideration: (1) the fewest number of internal fixation devices should be used to achieve rigid bony fixation, (2) the proximity of fixation devices to the regions of interest should be considered at the time of fixation, (3) titanium implants produce less artifacts than vitallium implants of comparable size, and (4) vitallium micro mesh and micro (1.0 mm) straight fixation devices do not produce artifacts resulting in significant image degradation.

Artifacts↗

Symmetry of projection in the quantitative analysis of mammographic images.

Mammographic parenchymal patterns are among the strongest indicators of the risk of developing breast cancer. Risk evaluation through breast patterns may have an important role in studies of the aetiology of breast cancer and for monitoring changes in the breast in evaluating potential risk-modifying interventions. Typically, patterns are assessed by an experienced radiologist according to Wolfe grade, or on a coarse quantitative scale according to percent density. Parenchymal characterization methods, to overcome variability of classification by human observer, are under investigation. These include image segmentation using semi-automatic thresholding and automatic classification through textural and density measures. An important practical question relates to the extent to which information about mammographic pattern is carried by any one of the four views obtained in a typical examination. Specifically, variations of right-left breast symmetry and variations between the two standard views of each breast were tested. The mammograms of 30 premenopausal women, comprising 90 images [30 each of the right cranial-caudal (RCC), left cranial-caudal (LCC) and right medial-lateral oblique (RMLO)] were evaluated. Parameters included both subjective (radiologist classification and interactive image thresholding) and objective (fractal and skewness indices) quantitative measurements of parenchymal pattern. For the parameters tested, a high degree of correlations was observed for measurements on the RCC, LCC and RMLO views. Pearson correlation coefficients between 0.86-0.96 were found for the comparisons of quantitative parameters. The strong correlations suggest that, in the study and application of mammographic density classification, representative information is provided in a single view.

Adult↗

X-ray imaging with amorphous selenium: optimal spectra for digital mammography.

The optimum x-ray spectra for acquisition of digital mammographic images using an amorphous selenium (a-Se) photoconductor are investigated. The recorded images consist of latent charge distributions on the surface of an a-Se plate, which are then read out using two methods, laser discharge, or flat panel recharge. The investigation is based on a model of the breast previously developed for a phosphor-based digital readout system, and has been extended to include the effects specific to the use of photoconductors. The effects of plate thickness, x-ray scatter, readout noise, dose, and the kind of breast tissue on the nature of the optimum spectrum are explored for the two readout methods. The results indicate that use of a kilovoltage setting in the current mammographic range, and a molybdenum target spectrum is appropriate for digital readout of a-Se detectors. This conclusion contrasts with the appreciably higher kilovoltages traditionally used with the xerographic (toner) readout of latent charge images on a-Se.

Biophysical Phenomena↗

Quantitative classification of mammographic densities and breast cancer risk: results from the Canadian National Breast Screening Study.

BACKGROUND: The radiographic appearance of the female breast varies from woman to woman depending on the relative amounts of fat and connective and epithelial tissues present. Variations in the mammographic density of breast tissue are referred to as the parenchymal pattern of the breast. Fat is radiologically translucent or clear (darker appearance), and both connective and epithelial tissues are radiologically dense (lighter appearance). Previous studies have generally supported an association between parenchymal patterns and breast cancer risk (greater risk with increasing densities), but there has been considerable heterogeneity in risk estimates reported. PURPOSE: Our objective was to determine the level of breast cancer risk associated with varying mammographic densities by quantitatively classifying breast density with conventional radiological methods and novel computer-assisted methods. METHODS: From the medical records of a cohort of 45,000 women assigned to mammography in the Canadian National Breast Cancer Screening Study (NBSS), a multicenter, randomized trial, mammograms from 354 case subjects and 354 control subjects were identified. Case subjects were selected from those women in whom histologically verified invasive breast cancer had developed 12 months or more after entering the trial. Control subjects were selected from those of similar age who, after a similar period of observation, had not developed breast cancer. The mammogram taken at the beginning of the NBSS was the image used for measurements. Mammograms were classified into six categories of density, either by radiologists or by computer-assisted measurements. All radiological classification and computer-assisted measurements were made using one craniocaudal view from the breast contralateral to the cancer site in case subjects and the corresponding breast of control subjects. All P values represent two-sided tests of statistical significance. RESULTS: For all subjects, there was a 43% increase in the relative risk (RR) between the lower and the next higher category of density, as determined by radiologists, and there was a 32% increase as determined by the computer-assisted method. For all subjects, the RR in the most extensive category relative to the least was 6.05 (95% confidence interval [CI] = 2.82-12.97) for radiologists and 4.04 (95% CI = 2.12-7.69) for computer-assisted methods. Statistically significant increases in breast cancer risk associated with increasing mammographic density were found by both radiologists and computer-assisted methods for women in the age category 40-49 years (P = .005 for radiologists and P = .003 for computer-assisted measurements) and the age category 50-59 years (P = .002 for radiologists and P = .001 for computer-assisted measurements). CONCLUSION: These results show that increases in the level of breast tissue density as assessed by mammography are associated with increases in risk for breast cancer.

Adult↗

Effects of non-linear flow and spatial orientation on technetium-99m hexamethylpropylene amine oxime single-photon emission tomography.

The effects of two post-acquisition corrections on the visual and quantitative analysis of technetium-99m hexamethylpropylene amine oxime (HMPAO) single-photon emission tomography (SPET) were determined. The corrections were for: (1) the improper spatial orientation of the patient data sets, and (2) the non-linear uptake of HMPAO across the blood-brain barrier. Reorienting the SPET image data sets removed observers' uncertainty in assessment caused by suspected head tilt; however, it increased their uncertainty due to perceived subtle perfusion deficits. Applying the correction to compensate for the decrease in uptake of HMPAO in high-flow regions resulted in an increase in the number of positive assessments. In a study involving 30 patient studies, intra-observer reliability increased from 62% to 83% (average of two observers) after applying both of the corrections, while inter-observer reliability improved from 62% to 81%. Quantitative methods of analysing the images are also affected by the corrections. In an ROI-based classification scheme, the quantitative assessments of more than one-half of the images are affected by the two corrections. These results need to be considered when comparing both quantitative and visual results from different studies in which the corrections may or may not have been applied.

Algorithms↗

Analysis of signal propagation in optically coupled detectors for digital mammography: I. Phosphor screens.

The angular emission of light from turbid phosphor screens has been measured and modelled. As a first approximation, turbid phosphor screens have traditionally been modelled as Lambertian sources; however, Giakoumakis et al have previously shown that light emission from turbid phosphor screens is in fact more forward peaked. In this article, we extend the theory of Giakoumakis to include turbid phosphor screens that incorporate a transparent overcoat. The refractive index of the optical coupling medium in contact with the overcoat is shown to have a direct effect on both light output and angular emission from the screen. It was found that simple laws of refraction adequately describe this phenomenon. To model the angular emission of light from such phosphor screens, a term was included to describe the refraction from the overcoat into the adjacent coupling medium. The data obtained are required to calculate the propagation of the signal in a digital mammography detector in which a phosphor screen is optically coupled to a charge-coupled device (CCD) image array.

Biophysical Phenomena↗

X-ray imaging with amorphous selenium: detective quantum efficiency of photoconductive receptors for digital mammography.

Factors affecting the zero spatial frequency detective quantum efficiency of photoconductor-based x-ray detectors operating in the mammographic energy range are modeled for monoenergetic incident x rays. The problem is separated into two sections: the calculation of the x-ray absorption and the Swank factor. X-ray absorption in this energy range, for most practical photoconductors, is dominated by the photoelectric effect. The Swank factor has four components: fluorescence escape, stochastic variations in gain, variations of gain due to incomplete coupling of charge from the photoconductive layer to the detector electrode, and the nonlinear discharge arising from the field-dependent x-ray gain, an effect that is unique to photoconductors. Calculations are performed for selenium, which is currently the most technologically advanced photoconductor available for digital x-ray imaging. For thicknesses of selenium exceeding 50 microns and for energies between 12 and 50 keV, the detective quantum efficiency of this photoconductor is found to exceed that of a conventional Gd2O2S-based mammographic phosphor screen.

Efficiency↗