Improving compatibility between blood packs and transfusion sets.

Significant variation between manufacturers exists in the force required to insert transfusion set spikes (closure-piercing device) into blood pack ports. This potential source of difficulty can impact directly on patient and staff safety (delayed transfusion, contamination of blood components, wastage, blood spillage and staff injury) and is not predicted or prevented by conformance of these medical devices to relevant International Organization for Standardization (ISO) standards. A quantitative, objective measurement of insertion force is described together with an assessment of factors affecting compatibility between the port and spike. Several advantageous and disadvantageous design features are identified and are being addressed through ISO Technical Committee 76 Work Group 1.

Blood Transfusion↗

Use of a (proposed) standard protocol to validate Terumo TSCD-II connections between dissimilar blood bag tubing.

BACKGROUND AND OBJECTIVES: ISO standards for blood bags do not adequately define and control the dimensions of blood bag transfer tubing. This lack of standardization presents potential difficulties when making sterile connections between the wide range of tubing that has evolved in the absence of such standards. We aim to validate the suitability of the TSCD-II and provide a minimum standard for assessing the suitability of sterile connections (welds) between dissimilar tubing. MATERIALS AND METHODS: The Terumo TSCD-II was used in this study to connect by hermetic welding seven tubing types with a wide range of dimensions from five suppliers. Thirty sterile connections were made between each combination split between dry/dry, wet/wet and dry/wet connections. Welds were assessed for visual defects, by tensile stress test (TST) and pressure tests. RESULTS: All welds passed visual inspection and pressure tests. All welds had a minimum tensile strength of greater than 40 N and mean of greater than 45 N. CONCLUSION: Successful connections have been made between dissimilar tube types and this work does not support the requirement for 'tight' tubing dimensional specifications. We have recommended to the ISO Technical Committee 76 Work Group 1 that ISO 3826-1 be revised and should include a minimum standard validation protocol for joining dissimilar tubing.

Blood Component Transfusion↗

Care management of work injuries: results of a 1-year pilot outcome assurance program.

A 1-year pilot study was conducted, linking the efforts of a workers' compensation managed care organization with those of an occupational health clinic and emergency department of manage work-related injuries and associated work disability. Sustained (> 90 day), injury-specific return-to-work outcomes, modified by job title, were compared with loosely managed and well-managed benchmarks. The mean return-to-work outcome, measured as lost workdays (LWDs), was 5.11 +/- 21.0 LWDs for 418 workers. These results exceeded benchmarks for both loosely managed care, 14.0 +/- 17.2 LWDs, P < 0.001 (8.9 fewer LWDs/case), and optimally case-managed care, 6.99 +/- 7.64 LWDs, P = 0.044 (1.9 fewer LWDs/case). An estimate of the value of these saved LWDs to the employers-at $200 per workday was $740,400 for the loosely managed benchmarks and $157,000 for the well-managed benchmarks. The Outcome Assurance Program virtually eliminated typical delays in the diagnosis and medical management of these injured workers.

Accidents, Occupational↗

Improved strategy for screening prospective blood donors for anaemia.

Women (568) and men (531) attending blood donation sessions in Wessex in September, 1992, were assessed for anaemia by the standard CuSO4 method on finger-prick (FP) blood samples. The haemoglobin (Hb) concentration on FP samples and on venous blood was also checked using the HemoCue. Different FP samples from the same donors revealed a wide variation on HemoCue. We recommend retaining the CuSO4 method on FP samples as the initial screen, and follow-up of apparent failures by determining the Hb concentration on venous sampling with the HemoCue. As 54% of females were found on venous samples to be below the current recommended threshold (125 g/L) for Hb concentration, we also recommend lowering the threshold to 115 g/L for women, and to 130 g/L for men. We further recommend a close re-examination of normal haematology values for adults.

Anemia↗

Platelet counting using plasma platelet concentrate samples.

Platelet counting using samples of plasma from platelet concentrates prepared for transfusion was assessed. The methods employed included a manual phase-contrast method, and counting with Coulter S Plus and Sysmex E-2500 counters. All methods were reproducible (mean CV of 4.9, 2.2 and 1.4%, respectively). However, neat samples of platelet concentrates analysed by Coulter counter were inaccurate (mean count of 863.8 x 10(9)/l compared to 1018.9 x 10(9)/l counted manually). Moreover, the Coulter platelet counts were non-linear above 900 x 10(9)/l, whereas the E-2500 platelet counts were linear to 2700 x 10(9)/l. A one-in-three pre-dilution was required to obtain accurate, linear counts with the Coulter counter, whereas the E-2500 was accurate without pre-dilution (mean count of 1030.2 x 10(9)/l compared to 1018.9 x 10(9)/l counted manually). In conclusion, the method of platelet counting may affect true platelet yields.

Automation↗

Naturopathy.