Real-time three-dimensional echocardiography: a novel technique to quantify global left ventricular mechanical dyssynchrony.

BACKGROUND: Left ventricular (LV) mechanical dyssynchrony (LVMD) has emerged as a therapeutic target using cardiac resynchronization therapy (CRT) in selected patients with chronic heart failure. Current methods used to evaluate LVMD are technically difficult and do not assess LVMD of the whole LV simultaneously. We developed and validated real-time 3D echocardiography (RT3DE) as a novel method to assess global LVMD. METHODS AND RESULTS: Eighty-nine healthy volunteers and 174 unselected patients referred for routine echocardiography underwent 2D echocardiography and RT3DE. RT3DE data sets provided time-volume analysis for global and segmental LV volumes. A systolic dyssynchrony index (SDI) was derived from the dispersion of time to minimum regional volume for all 16 LV segments. Healthy subjects and patients with normal LV systolic function had highly synchronized segmental function (SDI, 3.5+/-1.8% and 4.5+/-2.4%; P=0.7). SDI increased with worsening LV systolic function regardless of QRS duration (mild, 5.4+/-0.83%; moderate, 10.0+/-2%; severe LV dysfunction, 15.6+/-1%; P for trend <0.001). We found that 37% of patients with moderate to severe LV systolic dysfunction had significant dyssynchrony with normal QRS durations (SDI, 14.7+/-1.2%). Twenty-six patients underwent CRT. At long-term follow-up, responders demonstrated reverse remodeling after CRT with a significant reduction in SDI (16.9+/-1.1% to 6.9+/-1%; P<0.0001) and end-diastolic volume (196.6+/-17.3 to 132.1+/-13.5 mL; P<0.0001) associated with an increase in LV ejection fraction (17+/-2.2% to 31.6+/-2.9%; P<0.0001). CONCLUSIONS: RT3DE can quantify global LVMD in patients with and without QRS prolongation. RT3DE represents a novel technique to identify chronic heart failure patients who may otherwise not be considered for CRT.

Computer Systems↗

Effect of harmonic imaging on the measurement of ultrasonic integrated backscatter and its interpretation in patients following myocardial infarction.

BACKGROUND: Recently, we have demonstrated that cyclic variation in ultrasonic integrated backscatter (IBS) can be used to predict patency of the infarct related artery (IRA) post-acute myocardial infarction (AMI). Second harmonic imaging has become widely available on ultrasound machines and enhances endocardial definition. The effect of harmonic imaging on the measurement and interpretation of cyclic IBS is unknown. METHODS AND RESULTS: Twenty-eight patients were studied post-AMI. Cyclic IBS was measured in myocardial segments supplied by the IRA as well as in remote segments with normal myocardial function in both fundamental and second harmonic modes. Harmonic imaging increased the measurement of cyclic IBS in IRA as well as normal myocardial territories. However, the difference in cyclic IBS between IRA and normal myocardial territories remained unchanged. CONCLUSION: Second harmonic imaging increases the measurement of cyclic IBS. However, the interpretation of these data is unchanged in the setting of AMI. It is important that repeated studies in the same patient are performed in the same mode (fundamental or harmonic) as the values are not interchangeable.

Angioplasty↗

Determination of successful reperfusion after thrombolysis for acute myocardial infarction: a noninvasive method using ultrasonic tissue characterization that can be applied clinically.

BACKGROUND: The aim of the present study was to determine the use of cyclic variation in ultrasonic integrated backscatter (IBS), which is reduced in ischemic myocardium, to predict an occluded infarct-related artery (IRA) after thrombolysis for acute myocardial infarction (AMI). This is important, because patency of the IRA 90 minutes after thrombolysis has been shown to predict outcome. METHODS AND RESULTS: One hundred thirteen patients with AMI had peak-to-peak cyclic IBS measured in the myocardial territory supplied by their IRA as well as a remote territory with normal function from the parasternal long- or short-axis view. This analysis took 5 to 10 minutes. Wall motion score index was assessed, and coronary angiography, to determine patency of the IRA, was performed in all patients. Cyclic IBS in the IRA territory was much lower in segments supplied by an occluded IRA (3.3 versus 4.6 dB, P<0.00001). Using a difference in cyclic IBS between infarcted and normal segments of 15% (or 1.5 dB) as a cutoff, the sensitivity, specificity, positive and negative predictive values to determine an occluded IRA were 92%, 75%, 81%, and 89%, respectively. CONCLUSIONS: The difference in cyclic IBS between IRA and remote normal segments, which can be analyzed rapidly, can be used to predict patency of the IRA in patients with AMI. This provides a noninvasive method to determine those patients who may require urgent invasive investigation.

Coronary Angiography↗

Effects of aging on left atrial reservoir, conduit, and booster pump function: a multi-institution acoustic quantification study.

OBJECTIVE: To assess the feasibility of measuring left atrial (LA) function with acoustic quantification (AQ) and then assess the effects of age and sex on LA reservoir, conduit, and booster pump function. PATIENTS AND SETTING: 165 subjects without cardiovascular disease, 3-79 years old, were enrolled by six tertiary hospital centres. INTERVENTIONS: Continuous LA AQ area data were acquired and signal averaged to form composite waveforms which were analysed off-line. MAIN OUTCOME MEASURES: Parameters of LA performance according to age and sex. RESULTS: Signal averaged LA waveforms were sufficiently stable and detailed to allow automated analysis in all cases. An age related increase in LA area was noted. LA reservoir function did not vary with age or sex. All parameters of LA passive and active emptying revealed a significant age dependency. Overall, the passive emptying phase accounted for 66% of total LA emptying ranging from 76% in the youngest to 44% in the oldest decade. LA contraction accounted for 34% of atrial emptying in all subjects combined with the older subjects being more dependent on atrial booster pump function. When adjusted for atrial size, there were no sex related differences in LA function. CONCLUSIONS: LA reservoir, conduit, and booster pump function can be assessed with automated analysis of signal averaged LA area waveforms. As LA performance varies with age, establishment of normal values should enhance the evaluation of pathologic states in which LA function is important.

Acoustics↗

Forensic echocardiography: a case in point.

Transthoracic echocardiography (TTE) has an important role in the assessment of patients with acute penetrating chest trauma. We report the case of a 36-year-old man who sustained a stab wound to the chest. After admission, he required emergency pericardiocentesis. TTE revealed a traumatic ventricular septal defect and a defect in the anterior mitral valve leaflet. To assess whether these lesions were related to the initial stab wound or the pericardiocentesis, the transducer was positioned over the stab wound, and the lesions were shown to be in the same plane as the entry site, thus ruling out iatrogenic trauma.

Adult↗

Evaluation of myocardial, hepatic, and renal perfusion in a variety of clinical conditions using an intravenous ultrasound contrast agent (Optison) and second harmonic imaging.

OBJECTIVE: To assess the potential of intravenous Optison, a second generation ultrasound contrast agent, and various ultrasound imaging modes to determine myocardial, kidney, and liver perfusion in normal subjects and patients with left ventricular dysfunction or chronic pulmonary disease together with renal or hepatic dysfunction. METHODS: Five normal subjects and 20 patients underwent grey scale echocardiographic imaging of myocardium, kidney, and liver during 505 intravenous injections of Optison. Images were assessed qualitatively by two independent observers and quantitatively using video densitometry to determine the peak contrast enhancement effect. RESULTS: Qualitative analysis showed that intermittent harmonic imaging was superior to either conventional fundamental or continuous harmonic imaging for all organs. Quantitative analysis showed that the peak change in echocardiographic intensity v baseline during continuous harmonic imaging was 11 units for myocardium (p < 0.03), 7 units for kidney (NS), and 14 units for liver (p < 0.05). During intermittent harmonic imaging the peak change was significantly greater, being 33 units for myocardium (p < 0.0001), 24 units for kidney (p < 0.0002), and 16 units for liver (p < 0.001). CONCLUSIONS: Organ tissue perfusion can be demonstrated following intravenous injection of Optison, particularly when used in combination with intermittent harmonic imaging techniques. This contrast agent is effective in a variety of clinical conditions.

Adult↗