Search PubMed⌕ Search

Biomedical subjects

M J Lipton

Publications and source records attributed to M J Lipton.

At least 163 records · Page 9Linked to original sources

Tantalum labelling in vivo of cardiac ventricular chambers in dogs.

Demarcating fixed points in cardiac ventricles in the dog by catheter placement of tantalum coils has been shown to provide an excellent physiologic model. A new method emplying direct ventricular puncture has been developed for implanting these markers. The method has several advantages over an earlier peripheral catheter technique. Apical approach allows easier screw placement near the aortic and pulmonary valves. Peripheral vessels are left intact and pressure monitoring as well as contrast medium injection can be performed through the same catheter.

Animals↗

False aneurysms of the left ventricle. Identification of distinctive clinical, radiographic, and angiographic features.

False aneurysms of the left ventricle were observed in 14 patients. They were caused by obstructive coronary arterial disease with resultant myocardial infarction in 11, bacterial endocarditis in 1, a knife wound in 1, and disruption of a ventriculotomy in 1. Most of them extended posteriorly on the lateral radiograph, as opposed to the usual anterior position of true aneurysms. Enlargement was frequently observed on sequential studies. Angiography usually demonstrated involvement of the diaphragmatic or posterolateral segment due to occlusion of the right coronary artery; in contrast, true aneurysms are apical or anterolateral and are due to occlusion of the left anterior descending artery. The frequency of rupture of false aneurysms points up the importance of dinstinguishing them from true aneurysms.

Aged↗

Measurement of left ventricular cast volume by computed tomography.

Angiocardiographic methods available for cardiac-chamber volume measurements are neither consistently accurate nor precise. To explore the capability of computed tomography for left ventricular volume measurement, Silastic casts of 24 normal human left ventricles were measured by a displacement method, a conventional angiocardiographic biplane volume method, and computed tomography. The displacement method used degassing to remove air trapped in the casts; displacement was measured by Archimedes' principle. Cast volumes measured by biplane methods displayed spread around the regression line, caused by the chamber's irregular shape and its variations in orientation. Computed tomographic measurements were independent of chamber orientation and significantly more accurate.

Angiocardiography↗

Cardiovascular trauma from angiographic jets--validation of a theoretic concept in dogs.

The relationship of angiographic injections to cardiovascular trauma was determined. The aorta of dogs was studied by a mathematic model that (a) defines the kinetic energy of contrast-media jets emanating from the exit holes of catheters and (b) enables precise correlation of energy levels to potential trauma. A universal curve independent of the Reynolds number of the jet readily determines how far the jet penetrates intravascular blood. A traumatic histopathologic spectrum was found for those injections predicted by the model to be traumatic. The curve enables the angiographer to calculate the safe operating range of any catheter.

Angiography↗

Cardiac trauma from angiographic injections. A quantitative study.

To relate angiographic injections to potential cardiac trauma, we verified a mathematic theory that allows quantitative definition of the kinetic energy content of contrast jets emanating from the exit holes of angiographic catheters. Cineangiographic recordings of a range of jets of known energy content were obtained in 18 cardiac canine experiments and energy content and dissipation were quantified precisely from center line to jet edge. All contrast jets produced in clinical angiographic practice were turbulent, even those from hand injections into the coronary arteries. Energy content was related to an estimated cardiac wall damage threshold. At energy levels and damage thresholds predicted by the theory and computations, a traumatic spectrum was found by cineradiology and microscopic examination. A unique curve independent of jet Reynolds number was discovered relating the penetration of the contrast jet into the intravascular blood to the potential for cardiac trauma. This curve allowed ready calculation of hydraulic energy dissipation for any clinically used angiographic catheter and the definition of safe operational injection flow rates. Thus potential cardiac trauma can be anticipated and prevented.

Angiography↗

A conductive catheter to improve patient safety during cardiac catheterization.

A 60 Hz current, as small as 20 microamperemeter (rms) is capable of causing ventricular fibrillation when directly applied to the heart. Significant cost and engineering effort has been spent to construct monitoring equipment which satisfies the safety regulations requiring maximum leakage currents below this value. Patients undergoing cardiac catheterization are particularly at risk from electrical hazards, primarily because catheters are made from nonconductive materials. A conductive catheter should allow externally applied currents to leak through its walls before reaching the catheter tip. A new electrically conductive catheter was compared with a standard nonconductive catheter. Five dogs were studied, with 81 attempts to cause fibrillation. Sixty-hertz voltage between the catheter and an external electrode was increased until fibrillation occurred or 130 V was reached. Eight states were studied in randomized sequence: conductive or nonconductive catheter, guidewire or saline-filled and tip touching wall, or free in left ventricle (verified by fluoroscopy and cineangiography). The saline-filled and conductive catheter was safer in that fibrillation never occurred, while fibrillation nearly always occurred with the nonconductive catheter. A conductive guidewire negates the protection of the conductive catheter. The application of conductive catheters could reduce instrumentation costs in laboratories and intensive care units and improve patient safety.

Animals↗

Indium-111-labeled autologous platelets for location of vascular thrombi in humans.

Twenty-two patients suspected of having either venous or arterial thrombi were studied with In-111-labeled autologous platelets. Whole-body scans were performed 3, 24, and 48 hr following i.v. injection. Twelve patients studied with saline-washed platelets had unsatisfactory 15-min recovery and biologic half-time. When the labeling was carried out in plasma, these values compared favorably with normal values reported for Cr-51-labeled autologous platelets. Of ten patients studied using platelets labeled in plasma, three had normal scans, six had abnormal scans, and one had an equivocal scan. All six abnormal scans were confirmed with corresponding positive findings in either the venogram, arteriogram, or lung scan. J Nucl Med 19: 626-634, 1978.

Adult↗

Unstable angina: comparison of medical and surgical management.

Medical versus surgical treatment of unstable angina was compared in a prospective nonrandomized study of 118 patients. Acute transient ST-T wave changes were present during chest pain in all patients. Acute infarction was excluded by serial electrocardiograms and enzyme studies. All patients admitted to the coronary care unit from 1970 to 1975 who fulfilled the entry criteria were included in the study. The starting point for data evaluation was 5 days after hospital admission. Characteristics at entry were similar in 66 medically treated patients and 52 patients who had coronary bypass vein graft surgery. During a mean follow-up period of 23 months in 66 medically treated patients with unstable angina the incidence rate of nonfatal myocardial infarction was 17% and the total mortality rate 21 percent compared with respective rates of 19% and 5.8% in 52 surgically treated patients. In the surgical group 8 patients (15%) had a perioperative infarction and only 2 (4%) had a late infarction; one patient (2%) died at operation. Symptomatic improvement was observed more frequently in the surgically treated group. Sixty percent of surgically treated patients were free of angina compared with 21% of medically treated patients. Eight medically treated patients (12%) required late surgical treatment for persistent severe angina despite optimal medical management.

Angina Pectoris↗

A quantitative method for determining angiographic jet energy forces and their dissipation: theoretic and practical implications.

Jets emanating from the exit holes of cardiac catheters during angiographic injections are theoretically capable of producing severe localized cardiovascular trauma. We adopted a fluid mechanical model of an axially symmetric jet to define these energy forces quantitatively, especially as they would occur in the clinical setting. During angiographic injection at all catheter flow rates used clinically, the jet emanating from the exit hole was always turbulent. The physical characteristics of the turbulent jet penetration into the intravascular blood fell upon a universal curve independent of the jet Reynolds number. This curve, never previously described, allows ready calculation of hydraulic energy dissipation for any catheter of known length and lumen size. The diameter of the catheter exit orifice has a greater effect than injection flow rate on decreasing jet penetration. These results provide useful guidelines for reducing trauma during routine angiography.

Angiocardiography↗

Effects of coronary artery bypass grafting on resting and exercise hemodynamics in patients with stable angina pectoris: a prospective, randomized study.

In this prospective randomized study, resting and exercise hemodynamics were determined in the nonmedicated state before ("entry") and 1 year after coronary bypass surgery in 38 patients, and at entry and 1 year in 40 patients treated medically. The surgical group showed a significant decrease in mean pulmonary arterial wedge pressure during exercise (entry 23.5 +/- 6.1 [standard error of the mean] mm Hg, 1 year 18.9 +/- 1.0, P less than 0.02); an increase in cardiac index during exercise (entry 4.3 +/- 0.1 liter/min per m2, 1 year 4.6 +/- 0.1, P less than 0.05); an increase in resting mean arterial pressure (entry 94.5 +/- 2.2 mm Hg, 1 year 100.2 +/- 2.2, P less than 0.02); and an increase in resting heart rate (entry 68.5 +/- 1.9 beats/min, 1 year: 76.0 +/- 2.0, P less than 0.01). Maximal treadmill exercise performance also improved significantly in the surgical group of patients (entry 285 +/- 24 seconds, 1 year 382 +/- 24, P less than 0.002). There were no significant changes in these variables in the medically treated "control" group. The improvement in pulmonary arterial wedge pressure during exercise and in maximal treadmill exercise time in the surgical group as a whole was due to striking improvement in these variables in a subgroup of 16 surgical patients who had a more than 10 mm Hg increase in pulmonary arterial wedge pressure during exercise in their entry study. In this subgoup, considered to contain those patients with marked "ischemicdysfunction," pulmonary arterial wedge pressure during exercise fell from 31.4 +/- 1.5 mm Hg (entry) to 19.l +/- 1.8 (1 year) (P less than 0.0001) and treadmill time increased from 217 +/- 24 seconds (entry) to 357 +/- 37 (1 year) (P less than 0.001). Thus, hemodynamic evidence of ischemic left ventricular dysfunction during stress may identify those patients who will show objective improvement in ventricular performance after bypass graft surgery.

Angina Pectoris↗

Acute coronary embolism complicating bacterial endocarditis: operative treatment.

A patient with bacterial endocarditis and no previous history of angina substained an acute anterolateral myocardial infarction while awaiting surgery. Selective coronary arteriography revealed a filling defect in the left anterior descending coronary artery with limited flow beyond the area of occlusion. A calcific embolus from the infected aortic valve was removed at the time of valve replacement, and the patient had an uneventful immediate postoperative course. Late postoperatively paravalvular aortic regurgitation recurred before and after a second repair.

Acute Disease↗

The effect of coronary bypass surgery on exercise-induced ventricular arrhythmias.

Ninety-one patients with angiographically proved coronary artery disease and stable angina were randomly assigned into surgical and medical therapy. Graded exercise tests were performed on entry into the study and repeated in 1 year. Ventricular arrhythmias during exercise and 8 minutes of recovery were studied. Arrhythmias were graded on a scale of 0 to 7 by their presumed severity. On entry, both groups were similar in the severity of coronary disease, exercise capacity, and frequency and severity of exercise-induced ventricular arrhythmias. At 1 year, the frequency and severity of arrhythmias remained unchanged in both groups, whereas the surgically treated patients showed a marked improvement in their exercise capacity (p less than 0.005). The medically treated patients had a slight deterioration in their work capacity which, however, did not achieve statistical significance (p = 0.08). Twelve patients died suddenly. In seven medically treated patients who died suddenly, the frequency and severity of ventricular arrythmias on exercise were not different from those of the rest of the medical patients. In the five surgically treated patients who died suddenly, one had multiform premature ventricular beats, a second developed ventricular fibrillation (2 years before dying suddenly), and a third had no arrhythmias during exercise. Two died before the 1 year evaluation. Successful coronary surgery improves exercise capacity without decreasing associated ventricular arrhythmias. Exercise-induced ventricular arrhythmias, with the exception of ventricular fibrillation, may not be closely associated with the risk of sudden death.

Arrhythmias, Cardiac↗

Left anterior descending coronary artery obstruction. Clinical, electrocardiographic, and angiographic correlates.

Seventy-six patients with severe (greater than 80%) occlusive left anterior descending coronary artery disease by coronary angiography were examined for the electrocardiographic characteristics of this disease in the presence (group A 59 patients) or the absence (group B 17 patients) of anterior wall asynergy (akinesis or dyskinesis). The incidence of clinically documented anterior myocardial infarction in these two groups of patients was examined. The collateral circulation to the left anterior descending coronary artery was also examined in the groups of patients with and without anterior wall asynergy. Thirty-eight of 59 (64%) patients with anterior wall asynergy (group A) showed electrocardiographic signs of anterior myocardial infarction, 17 per cent showed probable electrocardiographic signs of anterior myocardial infarction and 19 per cent showed no electrocardiographic signs. None of the 17 patients without anterior wall asynergy (group B) showed electrocardiographic signs of anterior myocardial infarction. In group A 74.6 per cent had documented clinical evidence of previous anterior myocardial infarction. Collateral filling of the distal left anterior descending coronary artery was seen in 71 per cent of group A and 100 per cent of group B patients. There was a significantly higher incidence (P = 0.02) of collateral filling in the patients without electrocardiographic evidence of definite anterior myocardial infarction (93% of 28 patients), than in those who showed definite electrocardiographic evidence of anterior myocardial infarction (66% of 38 patients).it is concluded that severe occlusive left anterior descending coronary artery disease with anterior wall myocardial asynergy is usually associated with electrocardiographic signs of anterior myocardial infarction, whereas equally severe left anterior descending coronary artery disease without anterior wall asynergy is rarely associated with electrocardiographic abnormalities of anterior myocardial infarction. Severe left anterior descending coronary artery obstruction without electrocardiographic and angiographic evidence of anterior myocardial infarction is usually associated with collateral circulation to the left anterior descending coronary artery and collateral circulation to the left anterior descending coronary artery is present less frequently when obstruction is associated with anterior myocardial infarction.

Adult↗

The VA cooperative randomized study of surgery for coronary arterial occlusive disease II. Subgroup with significant left main lesions.

From a large cooperative prospective randomized study, data relating to a subgroup of 113 patients with angina pectoris and a significant lesion of the left main coronary artery were analyzed. Of these patients, 53 had been randomly allocated to a medical treatment group and 60 to a surgical treatment group. The former group received conventional medical treatment, while the surgical treatment group received one or more aortocoronary saphenous vein bypass grafts. Important risk factors were approximately uniformly distributed between the two groups. Both are being followed up to 60 months (average follow-up, 30 months). To date, 12 of 60 surgical patients (20%) and 19 of 53 medical patients (36%) died (P less than 0.06). The operative (30-day) mortality declined from a rate of 25% for the first 2 years of the study to 7% for the last 3 years. Of patients randomized in the latter 3 years of the study, 12 of 41 medical patients (29%) and three of 42 surgical patients (7%) died (P less than 0.01). The average follow-up period in this group was 24 months. The proportion surviving 24 months was clearly larger in the surgically treated group (P less than 0.02). The difference in the proportion of patients surviving after surgery as compared with medical treatment was greatest in patients with additional significant disease involving the right coronary artery, with or without left ventricular dysfunction. Relief of angina as assessed by an "anginal score" was also better in surgical patients to a significant degree. Graft-patency rates correlated well with relief of angina, but objective studies including treadmill testing are not yet available.

Angina Pectoris↗

Real-time imaging with a new ultrasonic camera: part II, preliminary studies in normal adults.

A new transmission ultrasound camera system has provided focused images in real time through the abdomen of adult volunteers at average incident sound intensity levels of less than 1 mW/cm-2. The camera uses a unique acousto-mechanical lens/deflection system and a linear array of piezoelectric transducers to detect the ultrasound image. BONY STRUCTURES AND COSTAL CARTILAGES WERE CLEARLY SEEN. The colon was regularly seen and the kidney could be outlined in several subjects. The stomach and duodenal bulb were demonstrated and peristalsis was observed using a barium contrast material. The camera has the potential of extending the use of ultrasound in clinical medicine by providing an ultrasound soft tissue imaging system analogous to an x-ray fluoroscope. The need for further clinical evaluation and research to improve the images is emphasized.

Adult↗