Search PubMed⌕ Search

Biomedical subjects

M J Lipton

Publications and source records attributed to M J Lipton.

At least 109 records · Page 6Linked to original sources

Quantitation of cardiac function by cine-CT.

The recent introduction of a millisecond CT scanner specifically designed for cinematographic real-time imaging of the heart is a significant advance, and its introduction could parallel the impact that cineangiography had on cardiac diagnosis. A major advantage of CT is that central catheterization for angiographic purposes is avoided, as relatively small amounts of intravenous contrast medium provide excellent CT contrast enhancement of the blood pool and cardiac structures. In this article, the cine-CT scanner and the scanning techniques involved are described briefly, and the methods used to analyze CT data are discussed. The initial results are described, as is the potential of cine-CT for quantitating cardiac function.

Cardiac Output↗

Magnetic resonance imaging of acute myocardial infarction using a nitroxyl spin label (PCA).

The effects of an intravenously administered nitroxyl spin label (PCA) on the magnetic resonance imaging (MRI) appearance and relaxation times of acute canine myocardial infarctions were studied. Twenty-four hours after ligation of the left anterior descending coronary artery (LAD), animals were either sacrificed immediately (three dogs) or injected with 3.0 mmol/kg of PCA prior to sacrifice (six dogs). The PCA group dogs were sacrificed at either 5 minutes postinjection (three dogs) or 15 minutes postinjection (three dogs). Magnetic resonance imaging (0.35 T) using spin-echo techniques demonstrated high signal intensity in the infarct relative to normal myocardium in all three groups. In the control group, the T1 and T2 relaxation times were longer in infarcted compared with normal myocardium, but only the measure in T2 reached statistical significance (P less than .05). PCA produced infarct-avid T1 shortening in the six dogs that received it. Contrast in the group sacrificed at 15 minutes postcontrast administration was greater than that in the control group due to T1 shortening in the infarct. Thus, PCA produces differential effects on normal and infarcted myocardium. Between 5 and 15 minutes after IV administration, it causes greater changes in the infarct due to prolonged retention in this region.

Animals↗

Ventricular diastolic pressure-volume shifts during acute ischemic left ventricular failure in dogs.

Ischemic left ventricular failure was produced in eight acutely instrumented, anesthetized dogs to study the contribution of changing myocardial compliance and pericardial pressure to shifts in right and left ventricular diastolic pressure-volume relations. Right and left ventricular and pericardial volumes were measured by ungated computed tomography. Cardiac volumes were manipulated by infusion of saline solution, hemorrhage, phenylephrine infusion and, during failure only, nitroglycerin administration. During both control and failure periods, these interventions shifted the left and right ventricular pressure-volume relations by changing pericardial pressure only; that is, these interventions caused no change in the ventricular transmural pressure-volume relation. The induction of failure as such increased pericardial pressure only minimally and did not change the left ventricular or right ventricular transmural pressure-volume relations significantly. Volume loading during the control period caused an apparent pericardial creep which attenuated the pericardial effect on ventricular pressure-volume relations. During failure, volume loading caused an increase of right ventricular volume, but tended to decrease left ventricular volume; this was associated with a leftward displacement of the interventricular septum. In conclusion, in the presence of ischemic left ventricular failure as well as normally, changes in preload, afterload and circulating blood volume shift ventricular diastolic pressure-volume relations by stretching or relaxing the pericardium, thus changing pericardial pressure. In these circumstances, there were no consistent changes in myocardial compliance.

Animals↗

Graft patency in patients with coronary artery bypass operation complicated by perioperative myocardial infarction.

Coronary artery bypass graft patency was examined by contrast-enhanced computed tomography in 18 patients with perioperative myocardial infarction soon after surgery to determine the role of graft occlusion. Preoperative coronary angiograms were reviewed to assess native coronary disease and visible collateral channels in the distribution of the myocardial infarction. Perioperative myocardial infarction was diagnosed if creatine kinase-MB was elevated, characteristic electrocardiographic changes occurred and, in the majority of cases, the pyrophosphate scan was positive. Fourteen patients (78%) had patent grafts and perioperative myocardial infarction in the distribution of the grafted vessel. Four patients had an occluded graft with infarction in the distribution of the grafted vessel. Among the 14 patients with patent grafts, there was a significant difference (p less than 0.0005) in the degree of the mean (+/- standard deviation) diameter stenosis of 80 +/- 11% in native coronary vessels supplying the perioperatively infarcted myocardium versus a 55 +/- 12% mean diameter stenosis in the 23 bypassed native coronary vessels supplying noninfarcted myocardium. It is concluded that the majority of perioperative myocardial infarcts associated with coronary artery bypass operations are not caused by graft occlusion. The severity of coronary obstruction in the grafted vessel and the lack of collateral vessels to the region of perioperative infarction in patients with patent grafts suggests that an island of jeopardized myocardium exists that is subject to inadequate intraoperative preservation.

Adult↗

Computed tomography in congenital heart disease.

The CT results in defining anatomic and certain physiologic features in patients with congenital heart and great vessel anomalies were reviewed in 32 patients with a variety of congenital cardiac and aortic arch anomalies. Most of these cases (18 patients) were selected on the basis of angiocardiographic or echocardiographic studies performed prior to the CT evaluation. In 14 patients CT was performed as the initial study. All examinations were contrast enhanced and performed on a third generation CT scanner with scan time of 2 or 4 s. The CT demonstration of abnormalities of the great vessels such as positional anomalies, atresias, and hypoplasias was equivalent to angiocardiography and usually superior to two-dimensional echocardiography. The CT results in 14 patients were sufficient to obviate catheterization and angiography; most of these cases were abnormalities of the thoracic aorta. The CT evaluation of intracardiac anatomy was inconsistent. It adequately defined septal defects and configurational (Ebstein anomaly) and bulboventricular loop abnormalities of the ventricles. However, valve anomalies were not adequately demonstrated by CT. The three-dimensional representation of cardiac and mediastinal vascular anatomy provided by this relatively noninvasive technique gives unique information in some cardiovascular anomalies. When faster scanning times are introduced, more definition of the cardiac structures should be possible, further increasing the diagnostic potential of CT.

Adolescent↗

Cardiac imaging using gated magnetic resonance.

To overcome the limitations of magnetic resonance (MR) cardiac imaging using nongated data acquisition, three methods for acquiring a gating signal, which could be applied in the presence of a magnetic field, were tested: an air-filled plethysmograph, a laser-Doppler capillary perfusion flowmeter, and an electrocardiographic gating device. The gating signal was used for timing of MR imaging sequences (IS). Application of each gating method yielded significant improvements in structural MR image resolution of the beating heart, although with both plethysmography and laser-Doppler velocimetry it was difficult to obtain cardiac images from the early portion of the cardiac cycle due to an intrinsic delay between the ECG R wave and peripheral detection of the gating signal. Variations in the temporal relationship between the R wave and plethysmographic and laser-Doppler signals produced inconsistencies in the timing of IS. Since the ECG signal is virtually free of these problems, the preferable gating technique is IS synchronization with an electrocardiogram. The gated images acquired with this method provide sharp definition of internal cardiac morphology and can be temporarily referenced to end diastole and end systole or intermediate points.

Animals↗

Magnetic resonance imaging of the pericardium: normal and pathologic findings.

Twenty normal subjects and ten patients with pericardial abnormalities underwent ECG-gated magnetic resonance (MR) imaging of the thorax using a 0.35-tesla superconducting system. The patients with pericardial abnormalities were also evaluated with serial chest radiographs, ultrasound, computed tomography, and/or angiography. ECG gating was necessary to identify the normal pericardium, which was visualized as a 1- to 2-mm-wide curvilinear structure of low signal intensity. Pericardial thickening in constrictive pericarditis was clearly delineated on gated MR images. Pericardial inflammation caused a marked increase in signal intensity as well as thickening of the pericardium. Pericardial effusions and pericardial adhesions were also demonstrated. A simple pericardial cyst and a complex pericardial mass were identified and differentiated from pericardial fat and diaphragmatic eventration. MR appears to be an important modality for the evaluation of pericardial disease.

Adult↗

Cardiac imaging with a high-speed Cine-CT Scanner: preliminary results.

CT scans were obtained with a Cine-CT Scanner that uses a rapidly moving focused electron beam. The 50-msec CT scans were obtained at two transverse levels simultaneously through the hearts of a series of four normal dogs and six patients, four with coronary artery disease and two with hypertrophic cardiomyopathy. Two scanning mode options were chosen. Myocardial wall thickening and motion were studied by obtaining ten 50-msec CT exposures during one heart-beat within less than one second (cine-CT mode). Regional myocardial blood flow was assessed by obtaining approximately 20 scans at the same level of the left ventricle; each 50-msec exposure was gated to the same phase of 20 sequential heartbeats after intravenous administration of contrast medium (dynamic mode). These initial studies show the feasibility of defining regional and global myocardial contraction using the cine-CT mode, and the considerable potential for measuring regional myocardial perfusion using the flow (dynamic) mode.

Animals↗

Effect of gadolinium-DTPA on the magnetic relaxation times of normal and infarcted myocardium.

Acute myocardial infarctions were produced in 11 dogs by ligation of the left anterior descending coronary artery. Twenty-four hours after ligation, 0.35 millimoles per kilogram of Gd-DTPA was injected intravenously, followed by cardiectomy either 90 seconds (3 dogs) or 5 minutes (5 dogs) later. The remaining 3 dogs had cardiectomy without injection of Gd-DTPA at 24 hours after coronary occlusion. The 3 dogs that did not receive Gd-DTPA had longer T1 and T2 relaxation times in infarcted myocardium than in normal myocardium, as measured by a 10.7-MHz magnetic resonance (MR) spectrometer. The T1 and T2 relaxation times of normal myocardium at 90 seconds postinjection of Gd-DTPA were significantly shorter (p less than 0.05) than those of the normal myocardium of animals that did not receive Gd-DTPA. At five minutes postinjection, significantly (p less than 0.01) greater T1 shortening was exhibited in the infarcted myocardium compared with adjacent normal myocardium in the dogs injected with Gd-DTPA. Thus, Gd-DTPA has differential and time-varying effects on relaxation times of normal and infarcted myocardium.

Animals↗

Imaging and characterization of acute myocardial infarction in vivo by gated nuclear magnetic resonance.

Imaging by nuclear magnetic resonance (NMR) techniques has been shown to provide high-contrast resolution between soft tissues and characterization of normal and pathologic tissues by differences in magnetic relaxation times. The current study was designed to determine whether electrocardiogram (ECG)-gated NMR imaging of the canine heart in vivo could distinguish normal from infarcted myocardium without the use of intravenous paramagnetic contrast agents. Seven dogs were studied by ECG-gated NMR imaging in vivo (spin-echo technique) with a 0.35 Tesla superconducting magnet at 2 to 7 days after ligation of the left anterior descending coronary artery. In six of the seven dogs, signal intensity was increased in the anterior wall compared with the remainder of the left ventricle; this region of high signal intensity corresponded to the area of myocardial infarction demonstrated at postmortem examination. The signal intensity of the infarcted region was 66 +/- 27% greater than that of normal myocardium (p less than .01). The T2 (spin-spin) relaxation time was 69 +/- 3% longer in the infarcted myocardium as compared with normal myocardium (p less than .01). The NMR images from the seventh dog had uniform signal intensity throughout the myocardium of the left ventricle. An infarct was not evident on postmortem examination in this dog. Thus gated NMR imaging in vivo by the spin-echo technique displays acute myocardial infarctions as regions of high signal intensity without the use of contrast media. The infarct is characterized by a prolonged T2 relaxation time.

Animals↗

Imaging by nuclear magnetic resonance in patients with chronic ischemic heart disease.

Cardiac anatomy was defined by gated nuclear magnetic resonance (NMR) imaging at a magnetic field strength of 3.5 kGauss in eight normal subjects and 10 patients with chronic myocardial infarctions. Multisectional imaging was performed with the spin-echo technique and encompassed most of the left ventricle in an imaging time of 5 to 12 min. In all subjects internal cardiac structure was well delineated without the use of any type of contrast medium. The myocardial wall-blood interface was sharply defined, resulting in visualization of trabeculations, papillary muscle, and chordal structures in both ventricles. In patients with ischemic heart disease, the extent of postinfarctional wall thinning, aneurysms, and mural thrombi were depicted on NMR images. Images obtained with the second spin-echo (delay time = 56 msec) demonstrated high signal intensity in regions of the left ventricular chamber adjacent to the site of aneurysms or infarctions; this finding suggested stasis of blood in a region of akinesis or dyskinesis. The results of this study show that gated NMR is feasible as a technique for imaging the human heart and is capable of demonstrating a variety of left ventricular abnormalities associated with chronic myocardial infarction. NMR is a completely noninvasive technique for clinical imaging of the cardiovascular system.

Adult↗

Nuclear magnetic resonance imaging of acute myocardial infarction in dogs: alterations in magnetic relaxation times.

Nuclear magnetic resonance (NMR) imaging was used to study 24-hour-old acute myocardial infarctions in 8 dogs. Images and measurements of excised hearts were obtained in a 6.5 ml bore-resistive NMR imager (0.35 Tesla). Spin echo NMR imaging in each instance demonstrated the area of infarction as a region of increased signal intensity compared with that in normal myocardium. The T1 and T2 values of the area of infarction were greater than those of normal myocardium in all dogs. For each dog the T1 value was greater for the infarct region; however, the group mean value for T1 (ms) of the infarct region (728 +/- 94) was not significantly greater than that for the normal region (650 +/- 87). The T2 value (ms) was discriminate for all dogs, and the mean value for the infarct region (48 +/- 2) was significantly different (p less than 0.01) from the value for normal myocardium (42 +/- 1). The percent water content of the infarct (79 +/- 1%) was significantly greater (p less than 0.01) than that of normal regions (76 +/- 1%). The linear relationship between T2 value and percent water content showed a good correlation coefficient (r = 0.90; p less than 0.01). NMR imaging detects acute myocardial infarction as a positive image without contrast media. Increased signal intensity of the infarct is related to increased hydrogen density and increased T2 relaxation time.

Animals↗

Evaluation of early postoperative coronary artery bypass graft patency by contrast-enhanced computed tomography.

Fifty patients with 117 coronary bypass grafts were studied by contrast-enhanced computed tomography at an average of 5 +/- 4 days after surgery to determine if this technique was a feasible method for detecting early postoperative graft occlusion. The study was limited in only three patients because of incisional chest pain (one patient) or multiple metal clips attached to the graft (two patients). The distal patency of sequential grafts cannot be determined by current techniques. There was a lower graft patency rate (70%) in the 10 patients with perioperative myocardial infarction than in the 40 (95%) without (p less than 0.025), but most regions of infarcted myocardium were perfused by patent grafts. There were eight graft occlusions in eight patients. The graft occlusion rate (30%) was significantly higher (p less than 0.025) in grafts with intraoperative flows less than 45 ml/min. The postoperative complications of myocardial dysfunction, arrhythmia and coronary artery spasm did not correlate with graft occlusion. Early graft occlusion is uncommon (7%) and usually occurs in grafts with low flows or severe distal disease (seven of eight grafts), or both. Thus, the need for early reoperation is very infrequent. It is concluded that contrast-enhanced computed tomography is feasible for the assessment of coronary bypass graft patency. Because early graft occlusion is unusual the technique may be an ideal noninvasive screening method.

Aged↗

Nuclear magnetic resonance imaging of the cardiovascular system: normal and pathologic findings.

Whole body nuclear magnetic resonance (NMR) imaging of the cardiovascular system was carried out in early clinical trials in 244 volunteers and patients using a 3.5 KGauss (0.35 T) unit. The spin echo technique with multiple imaging parameters was used. Blood vessels were clearly discriminated from solid organs and lesions because little or no intraluminal signal is seen with laminar blood flow at normal velocities, whereas a more intense image is generated by solid organs. Characteristic flow signals were observed in normal patients and were accentuated by varying the imaging parameters. Cardiac chambers were well delineated in some patients on nongated images. In one case, internal topography of the ventricles was exquisitely displayed on a gated image. Intraluminal pathology, such as dissection of the aorta, aneurysms of the aorta and left ventricle, and aortic atheroma, was clearly demonstrated. Patency of coronary arterial bypass grafts was shown. Abnormal flow patterns due to slow or turbulent flow were accentuated on images using the second spin echo. This preliminary experience indicates the considerable potential of NMR imaging in the evaluation of cardiovascular diseases.

Blood Flow Velocity↗

Nuclear magnetic resonance imaging of the infarcted muscle: a rat model.

Eleven Sprague-Dawley rats with experimentally produced infarction of the lower extremities were imaged by nuclear magnetic resonance (NMR) immediately after infarction, and 6 and 24 hours later. Contrast between the infarcted and control muscles was noted immediately and continued to increase through 24 hours. These changes corresponded to a significant increase in the water content of the infarcted extremity at 24 hours. These results suggest promise for NMR imaging in the identification of myocardial infarction and should encourage further investigation in this area.

Animals↗

Nuclear magnetic resonance imaging of atherosclerotic disease.

Nuclear magnetic resonance (NMR) images of 93 patients undergoing studies of the abdomen and pelvis were studied for evidence of lesions of the aorta and the iliac and femoral arteries; atherosclerotic lesions were present in 13 of them. The lesions consisted of eccentric and concentric mural thickening with luminal narrowing and discrete plaques protruding into the vessel lumen. This appearance was distinctly different from the morphology of the internal vessel surface and uniformly thin vessel wall in normal patients and volunteers under the age of 30 years. Intraluminal flow signals observed in atherosclerotic and nonatherosclerotic subjects could be distinguished from mural lesions because of their lack of contiguity with the vessel wall and variation in appearance on multiple images obtained with the first and second spin echo. This initial experience suggests a potential role for NMR in the noninvasive imaging of atherosclerotic lesions. The natural contrast between flowing blood and the vessel wall indicates a distinct advantage of NMR for vascular imaging.

Abdomen↗