Search PubMed⌕ Search

Biomedical subjects

M J Kern

Publications and source records attributed to M J Kern.

At least 91 records · Page 5Linked to original sources

Coronary flow in a prosthetic aorto-coronary bypass graft: first report of Possis Perma-Flow graft physiology in a patient.

The coronary physiology of a prosthetic Perma-Flow coronary bypass graft conduit is demonstrated in the first patient at 1-yr follow-up. Coronary blood flow velocity was measured in the body of the graft and into the side-to-side anastomosis to the first diagonal branch. This case report demonstrates the first information on the coronary and prosthetic graft flow in a patient with atherosclerotic coronary disease.

Aged↗

Characterization of intra-arterial flow velocity within left coronary to pulmonary artery fistula.

The physiology of a coronary to pulmonary artery fistula has not been well characterized. This case report demonstrates the flow velocity pattern of a coronary fistula to the pulmonary artery which supports the hypothesized physiology that flow is predominantly continuous without a phasic pattern. The flow velocity within a coronary fistula has not been previously demonstrated.

Arterio-Arterial Fistula↗

Unsuspected articulation side-strut extension during stenting in a tortuous right coronary artery.

This case report demonstrates the effect of articulation stent-strut extension during attempts to deploy a stent in a tortuous, calcified right coronary artery. The manipulation of the stent-sheath relationship and the effect of a tortuous, calcified artery produced serial dissections resulting in the implantation of three stents to seal the dissection. Caution should be used when employing rigid sheathed stent systems through tortuous vessels.

Aged↗

Practical coronary physiology. Clinical application of the Doppler flow velocity guide wire.

Coronary angiography incompletely delineates the physiologic consequences of many epicardial stenoses. Intracoronary translesional flow velocity measurements using the Doppler flow wire during cardiac catheterization provide immediate data discriminating the physiologic significance of coronary stenoses. The validity and accuracy of the flow wire for analyzing lesion hemodynamic significance have been confirmed in multiple studies. Flow velocity analysis provides objective criteria for refining the selection of cases for revascularization, and prospective clinical data have confirmed the safety of deferring intervention on lesions with normal physiologic assessment. Translesional and distal coronary flow velocity dynamics during procedures also provide immediate data assessing the physiologic adequacy of intervention. Impaired postintervention distal coronary flow velocity and vasodilator reserve can predict subsequent clinical events, and comparisons of flow velocity indices prestenting and poststenting suggest that physiologically inadequate results of angioplasty may be improved by additional intervention. Flow velocity assessment may also have utility in profiling the adequacy of infarct artery reperfusion following acute myocardial infarction. Evidence has been accumulated to support use of Doppler flow velocity analysis as a clinically relevant technique for improving both diagnostic and therapeutic aspects of cardiovascular medicine.

Angioplasty↗

Role of coronary artery lumen enlargement in improving coronary blood flow after balloon angioplasty and stenting: a combined intravascular ultrasound Doppler flow and imaging study.

OBJECTIVES: This study sought to examine the mechanism of increasing coronary flow reserve after balloon angioplasty and stenting. BACKGROUND: Coronary vasodilatory reserve (CVR) does not improve after percutaneous transluminal coronary angioplasty in > or = 50% of patients, postulated to be due to impaired microvascular circulation or inadequate lumen expansion despite adequate angiographic results. METHODS: To demonstrate the role of coronary lumen expansion, serial coronary flow velocity (0.014-in. Doppler guide wire) was measured in 42 patients before and after balloon angioplasty and again after stent placement. A subset (n = 17) also underwent intravascular ultrasound (IVUS) imaging of the target sites after angioplasty and stenting. CVR (velocity) was computed as the ratio of adenosine-induced maximal hyperemic to basal average peak velocity. RESULTS: The percent diameter stenosis decreased from (mean +/- SD) 84 +/- 13% to 37 +/- 18% after angioplasty and to 8 +/- 8% after stenting (both p < 0.05). CVR was minimally changed from 1.70 +/- 0.79 at baseline to 1.89 +/- 0.56 (p = NS) after angioplasty but increased to 2.49 +/- 0.68 after stent placement (p < 0.01 vs. before and after angioplasty). IVUS lumen cross-sectional area was significantly larger after stenting than after angioplasty (8.39 +/- 2.09 vs. 5.10 +/- 2.03 mm2, p < 0.05). Anatomic variables were related to increasing coronary flow velocity reserve (CVR vs. IVUS lumen area: r = 0.47, p < 0.005; CVR vs. quantitative coronary angiographic percent area stenosis: r = 0.58, p < 0.0001). CONCLUSIONS: In most cases, increases in CVR were associated with increases in coronary lumen cross-sectional area. These data suggest that impaired CVR after angioplasty is often related to the degree of residual narrowing, which at times may not be appreciated by angiography. A physiologically complemented approach to balloon angioplasty may improve procedural outcome.

Angioplasty, Balloon, Coronary↗

From research to clinical practice: current role of intracoronary physiologically based decision making in the cardiac catheterization laboratory.

Decisions regarding coronary interventions should be combined with objective evidence of myocardial ischemia. The most common physiologic approach utilizes hospital facilities outside the catheterization laboratory, requiring additional time and cost. With the introduction of sensor-tipped angioplasty guide wires, distal coronary flow velocity and pressure can be obtained in the cardiac catheterization laboratory, facilitating physiologically based decisions regarding the need for intervention. In the catheterization laboratory, physiologically significant stenoses can be characterized as having impaired post-stenotic coronary flow reserve < 2.0 and pressure-derived fractional flow reserve < 0.75, both variables related strongly to positive ischemic perfusion imaging or stress testing results. Deferring coronary interventions on the basis of normal translesional physiology is safe and is associated with a low rate (< 10%) of lesion progression over a 10-month follow-up period. Preliminary data indicate that excellent physiologic and anatomic end points after balloon angioplasty are associated with low (< 20%) restenosis rates at 6-month follow-up. Clinically relevant relations of in-laboratory physiology support the insight that physiologic, as much as or more than anatomic variables, ultimately determine the functional status of a patient. Current data suggest that an intracoronary physiologic approach complements coronary lumenology and appears to have important clinical and economic implications for patients undergoing invasive evaluation and treatment of coronary artery disease.

Blood Flow Velocity↗

[To surpass coronary luminology with interventional physiology].

Interventional physiology, as much as anatomic parameters, ultimately determine the functional status and well being of a patient. Although technical improvements in equipment and more clinical studies are needed, the current experience indicates that interventional physiology has moved from a research tool to clinical adjunct. A physiologic approach complements coronary interventions and has important clinical and economic implications for patients undergoing invasive treatment of coronary artery disease.

Adult↗

Assessment of blood flow distal to coronary artery stenoses. Correlations between myocardial positron emission tomography and poststenotic intracoronary Doppler flow reserve.

BACKGROUND: Previous studies have correlated quantitative coronary angiographic stenosis severity with positron emission tomography (PET) myocardial perfusion and proximal measurements of intracoronary flow velocities in normal and diseased coronary arteries. The aim of this study was to correlate regional myocardial blood flow (RMBF) derived from [15O]H2O PET with directly measured poststenotic intracoronary Doppler flow velocity data acquired under basal conditions and dipyridamole-induced hyperemia. METHODS AND RESULTS: Eleven consecutive patients 53 +/- 13 years old with ischemic chest pain and isolated proximal left coronary artery stenoses (left anterior descending, 9; left circumflex, 2; mean, 59 +/- 23% diameter stenosis) underwent [15O]H2O myocardial PET and intracoronary Doppler flow velocity studies within 1 week. PET RMBF (mL.g-1.min-1) and myocardial perfusion reserve (MPR) were calculated in poststenotic and normal reference vascular beds. Poststenotic Doppler average peak flow velocities (APV; cm/s) and coronary flow velocity reserve (CFR) were compared with corresponding PET data and quantitative angiographic lesional parameters. PET RMBF and Doppler APV were linearly correlated (r = .60; P < .001), as were poststenotic PET MPR and Doppler CFR (r = .76; P < .0002). Relative coronary flow velocity and MPR ratios between poststenotic and angiographically normal vascular beds were comparably reduced (0.83 +/- 0.25 versus 0.86 +/- 0.21, respectively; P = NS). CONCLUSIONS: Intracoronary Doppler flow velocities acquired distal to isolated left coronary artery stenoses correlated with [15O]H2O PET regional myocardial perfusion and are useful for assessment of the physiological significance of coronary stenoses in humans.

Adult↗

Variations in normal coronary vasodilatory reserve stratified by artery, gender, heart transplantation and coronary artery disease.

OBJECTIVES: The purpose of the study was to assess the spectrum of coronary vasodilatory reserve values in patients with angiographically normal arteries who had atypical chest pain syndromes or remote coronary artery disease or were heart transplant recipients. BACKGROUND: The measurement of post-stenotic coronary vasodilatory reserve, now possible in a large number of patients in the cardiac catheterization laboratory, is increasingly used for decision making. Controversy exists regarding the range of normal values obtained in angiographically normal coronary arteries in patients with different clinical presentations. METHODS: Quantitative coronary arteriography was performed in 214 patients classified into three groups: 85 patients with chest pain syndromes and angiographically normal arteries (group 1); 21 patients with one normal vessel and at least one vessel with > 50% diameter lumen narrowing (group 2); and 108 heart transplant recipients (group 3). Coronary vasodilatory reserve (the ratio of maximal to basal average coronary flow velocity) was measured in 416 arteries using a 0.018-in. (0.04 cm) Doppler-tipped angioplasty guide wire. Intracoronary adenosine (8 to 18 micrograms) was used to produce maximal hyperemia. RESULTS: Coronary vasodilatory reserve was higher in angiographically normal arteries in patients with chest pain syndromes (group 1:2.80 +/- 0.6 [group mean +/- SD]) than in normal vessels in patients with remote coronary artery disease (group 2: 2.5 +/- 0.95, p = 0.04); both values were significantly higher than those in the post-stenotic segment of the diseased artery (1.8 +/- 0.6, p < 0.007). Coronary vasodilatory reserve in transplant recipients (group 3) was higher than that in the other groups (3.1 +/- 0.9, p < 0.05 vs. groups 1 and 2) as a group and for individual arteries. When stratified by vessel, coronary vasodilatory reserve was similar among the left anterior descending, left circumflex and right coronary arteries. There were no differences between coronary vasodilatory reserve values on the basis of gender for patients with coronary artery disease and transplant recipients. In group 1 (chest pain), there was a trend toward higher coronary vasodilatory reserve in men than in women (2.9 +/- 0.6 vs 2.7 +/- 0.6, p = 0.07). CONCLUSIONS: These findings identify a normal reference range for studies assessing the coronary circulation and post-stenotic coronary vasodilatory reserve in patients with and without coronary artery disease encountered in the cardiac catheterization laboratory.

Aged↗

Determination of angiographic (TIMI grade) blood flow by intracoronary Doppler flow velocity during acute myocardial infarction.

BACKGROUND: This study compared angiographically graded coronary blood flow with intracoronary Doppler flow velocity in patients during percutaneous transluminal coronary angioplasty (PTCA) for acute myocardial infarction. Different TIMI angiographic flow grades (flow grades based on results of the Thrombolysis in Myocardial Infarction trial) have been associated with different clinical results after reperfusion for acute myocardial infarction. However, intracoronary blood flow velocity has not been compared with the angiographic method of determining flow grade in patients. METHODS AND RESULTS: Coronary flow velocity (measured by use of a Doppler guidewire) during primary or rescue PTCA in 41 acute myocardial infarction patients was compared with TIMI grade and cineframes-to-opacification count. Before PTCA, 34 patients had TIMI grade 0 or 1, 5 had TIMI grade 2, and 2 had TIMI grade 3 flow in the infarct artery. Flow velocity was similar among patients with TIMI grades 0, 1, or 2 but was lower than in those with TIMI grade 3 flow (9.4 +/- 5.4 versus 16.0 +/- 5.4 cm/s for TIMI grades < or = 2 versus TIMI grade 3, respectively; P < .05). After PTCA, 1 patient had TIMI grade 1, 5 had TIMI 2, and 35 had TIMI 3 flow. Poststenotic flow velocity increased from 6.6 +/- 6.1 to 20.0 +/- 11.1 cm/s (P < .01). TIMI grade 3 flow increased to 21.8 +/- 10.9 cm/s (P < .05 versus before PTCA). Although post-PTCA flow velocity correlated with angiographic cineframes-to-opacification count (r = .45; P < .02) for TIMI grade 3, there was a large overlap with TIMI grades < or = 2 that had low flow velocity (< 20 cm/s). Nine of 11 clinical events (unstable angina and coronary artery bypass graft surgery) occurred in patients with low coronary flow velocity. CONCLUSIONS: Determination of flow velocity after reperfusion may enhance patient characterization and provide the physiological rationale for clinical variations after reperfusion therapy.

Adult↗

Correlation of poststenotic hyperemic coronary flow velocity and pressure with abnormal stress myocardial perfusion imaging in coronary artery disease.

The functional significance of coronary stenoses is frequently determined by adjunctive noninvasive myocardial perfusion imaging. Poststenotic coronary flow velocity and pressure can be measured directly during routine cardiac catheterization. The aim of this study was to correlate poststenotic (distal) flow velocity and pressure with stress perfusion imaging in patients. Quantitative angiography, basal and hyperemic transstenotic coronary flow velocities, and pressure gradients were measured in 50 patients within 1 week of exercise (n = 29) or of pharmacologic (n = 21) stress perfusion imaging. Twenty-two of 25 patients (88%) with reversible perfusion abnormalities had diminished distal coronary flow velocity reserves (CFVR) of < or = 2.0 x baseline, whereas 22 of 25 (88%) with normal perfusion imaging studies had a normal distal CFVR of > 2.0 (p = 0.000 1). Thirteen of 25 patients (52%) with reversible perfusion abnormalities had transstenotic gradients > or = 20 mm Hg, whereas 20 of 25 (80%) with normal perfusion studies had gradients <20 mm Hg (p = 0.01). Quantitative angiography did not differentiate patients with normal versus abnormal myocardial perfusion imaging. Distal CFVR was correlated more significantly with myocardial perfusion imaging results (kappa = 0.76) than with pressure gradients (kappa = 0.32). Exercise and pharmacologic stress myocardial perfusion imaging abnormalities reflect diminished post-stenotic coronary flow to a greater degree than transstenotic pressure gradients.

Adult↗

Translesional pressure and flow responses in a patient with a vasoactive and atherosclerotic coronary artery.

Sympathetic stimulation produces characteristic changes in systemic and coronary hemodynamics which can be detected by pressure and flow velocity measurements in patients with coronary artery disease. In this particular patient with a highly reactive coronary vasculature in association with a fixed obstructive lesion, marked vasoreactivity produced striking differences in the resting translesional pressure gradient and flow velocity. Intracoronary nitroglycerin was immediately effective in relieving adverse vasoconstrictor tone. Studies of coronary hemodynamics during sympathetic stimulation in such patients will lead to improved understanding of the therapeutic modalities and associated interventional techniques to treat ischemic producing vasoreactive coronary arteries.

Adult↗