Search PubMed⌕ Search

Biomedical subjects

M J Hagmann

Publications and source records attributed to M J Hagmann.

22 records · Page 2Linked to original sources

Experimental characterization of the miniannular phased array as a hyperthermia applicator.

A series of experiments has been carried out in order to characterize a miniannular phased array applicator prior to possible clinical implementation. The energy deposition patterns over the frequency range of 100 to 200 MHz were determined in several human limb models of different complexities by measuring the electric field strength patterns. The point of maximum energy deposition within a homogeneous, muscle-equivalent cylindrical phantom positioned coaxially within the MAPA was found to be at the center of the applicator. The energy deposition patterns seem to be more uniform at the lower frequencies. Inclusion of a cylindrical bone-equivalent phantom positioned coaxially with this muscle-equivalent phantom does not seem to significantly alter the energy deposition patterns in the muscle-equivalent region. For more realistically shaped, homogeneous muscle-equivalent limb models, the resulting energy deposition patterns appear to be confined mostly to the intended treatment region. However, the point of maximum energy deposition was not at the middle of the applicator as with the cylindrical model, but shifted towards a smaller cross-sectional region. This shift in location of the point of maximum energy deposition varies with the location of the MAPA on the limb. A secondary region of high-field strength was also observed at the ankle for a MAPA centered about the knee. In this study, the energy deposition patterns appear to be significantly dependent on the shape of the model. Therefore, this factor must be taken into consideration for the proper prediction and control of the heating patterns resulting from the use of this type of applicator for clinical hyperthermia treatment.

Humans↗

Interstitial microwave hyperthermia applicators having submillimetre diameters.

Using microscopic techniques we have fabricated interstitial hyperthermia applicators having diameters of 0.20, 0.33 and 0.58 mm, which will fit through catheters of 30, 26 and 22 gauge, respectively. Existing commercial applicators having a diameter of 1.1 mm required 17 gauge (or larger) catheters. Our new applicators, which operate at 915 MHz, are a smaller version of a design used by others. We have characterized our applicators by determining the energy deposition patterns (SAR) in muscle-simulating phantoms. These patterns were determined by measuring the electric field intensity using a miniature implantable isotropic probe having a diameter of 3 mm. Contours of the SAR data for our applicators, as well as a larger commercial applicator, show that all of these applicators exhibit similar heating patterns. Test results suggest that the durability and power handling capability of our submillimetre applicators are adequate for use in patients. Our new applicators should be useful in the percutaneous treatment of deep-seated tumours, intraoperative treatments, and also permit intraluminal or intravascular access to tumours.

Biomedical Engineering↗

Evaluation of heating patterns of microwave interstitial applicators using miniature electric field and fluoroptic temperature probes.

The SAR patterns were determined for four commercially available microwave (915 MHz) interstitial applicators. Values of SAR were determined using a miniature (3 mm diameter) implantable isotropic electric field probe or a custom 0.25 mm diameter fluoroptic temperature probe. These are the smallest such probes that are currently available. Similar radial variation of SAR was found at the axial position of the gap in the outer conductor for each applicator. Electric field probe measurements are much faster and avoid some of the errors caused by the rapid spatial variation of SAR with interstitial applicators. The major limitation on the electric field probe is its size; it is larger than the applicators being tested.

Electronics, Medical↗