Search PubMed⌕ Search

Biomedical subjects

M J Greco

Publications and source records attributed to M J Greco.

4 recordsLinked to original sources

Polymer of proline analogue with sustained antifibrotic activity in lung fibrosis.

Inhibitors of collagen such as cis-4-hydroxy-L-proline (cHyp) may ameliorate bleomycin (bleo)-induced pulmonary fibrosis. An alternating polymer of poly(ethylene glycol) (PEG)-lysine (PEG-Lys) with cHyp attached as a pendant side chain was prepared for intratracheal delivery with bioinactive trans-Hyp (tHyp) polymer as control. To test whether the cHyp polymer has prolonged lung retention and sustained antifibrotic activity, we first instilled 3H- and 14C-labeled cHyp polymer in normal rats. Lung retention was 86 +/- 9% at 6 h and 29 +/- 3% at 7 d (n = 5). Next, rats were instilled intratracheally with either saline (sal) or 1.2 U bleo, and the following treatment groups were studied: Bleo/sal; Bleo/cHyp polymer; Bleo/tHyp polymer; and Bleo/PEG-Lys + cHyp. The dose of the test agents was 150 mg/kg polymer containing 8.5 mg/kg cHyp or tHyp instilled intratracheally at 7 and 14 d after bleo. At 21 d, hydroxyproline content (mg/lung) was: Control, 1.8 +/- 0.1; Bleo/sal 4.0 +/- 0.1*; Bleo/cHyp polymer, 2.8 +/- 0.3*+; Bleo/tHyp polymer, 4.4 +/- 0.2*; and Bleo/PEG-Lys + cHyp, 4.0 +/- 0.1* (*p < 0.05 versus Control; +p < 0.05 versus Bleo/sal; n = 5/group). The cHyp polymer also reduced lung total protein content, but the decrease was not significant. The dose required to produce 50% inhibition of lung collagen was approximately 700-fold less than monomeric cHyp. Thus, the cHyp polymer is a potent, long-acting antifibrotic agent which may be useful in treating lung fibrosis.

Animals↗

Utilising patient feedback in the RACGP training program. An exploratory study.

The doctor-patient relationship is the hub of general practice. Today, there is an increasing use of patients in the evaluation of doctors' interpersonal skills. This paper reports on the findings of an exploratory study designed to investigate the feasibility of using patient feedback as an educational tool for GP trainees.

Adult↗

Nebulizer function during mechanical ventilation.

In the setting of mechanical ventilation, recent studies have cast doubt on the ability of nebulizer systems to deliver adequate amounts of medication. We therefore studied ventilator-related and nebulizer-related factors that could potentially affect the amount of aerosol inhaled by an intubated subject. Utilizing two separate protocols, we used a bench model of a ventilator circuit, radiolabeled (technetium pertechnetate, 99mTc) saline droplets and a filter technique to measure the percentage of radioaerosol delivered. First, we compared four commercially available jet nebulizers and found that there were significant differences in rate of aerosol production between systems, ranging from 3 to 37%. Delivered aerosol was measured at different ventilator settings, and it was found that the duty cycle can potentially influence output by sevenfold. Some nebulizers were also sensitive to changes in the initial volume of solution placed in the nebulizer. The inclusion of a humidification device significantly reduced output by a mean of 41 +/- 3.5%, but it did not affect particle distribution. Endotracheal tube diameter was not an important variable. Then, with the effects of the above variables established, a separate series of experiments was performed to test whether the use of different radiolabeling compounds can confound the measurement of inhaled drugs. Two nebulizers (AeroTech II and Twin Jet) and pentamidine as the test drug were studied with fixed ventilator settings, treatment time, endotracheal tube size, and volume fill. No humidification was used. The nebulizer solution was labeled with 99mTc, which was bound to either human serum albumin (HSA) or sulfur colloid (SC).(ABSTRACT TRUNCATED AT 250 WORDS)

Aerosols↗