Search PubMed⌕ Search

Biomedical subjects

M J Bronskill

Publications and source records attributed to M J Bronskill.

At least 19 recordsLinked to original sources

A robust method for extraction and automatic segmentation of brain images.

A new protocol is introduced for brain extraction and automatic tissue segmentation of MR images. For the brain extraction algorithm, proton density and T2-weighted images are used to generate a brain mask encompassing the full intracranial cavity. Segmentation of brain tissues into gray matter (GM), white matter (WM), and cerebral spinal fluid (CSF) is accomplished on a T1-weighted image after applying the brain mask. The fully automatic segmentation algorithm is histogram-based and uses the Expectation Maximization algorithm to model a four-Gaussian mixture for both global and local histograms. The means of the local Gaussians for GM, WM, and CSF are used to set local thresholds for tissue classification. Reproducibility of the extraction procedure was excellent, with average variation in intracranial capacity (TIC) of 0.13 and 0.66% TIC in 12 healthy normal and 33 Alzheimer brains, respectively. Repeatability of the segmentation algorithm, tested on healthy normal images, indicated scan-rescan differences in global tissue volumes of less than 0.30% TIC. Reproducibility at the regional level was established by comparing segmentation results within the 12 major Talairach subdivisions. Accuracy of the algorithm was tested on a digital brain phantom, and errors were less than 1% of the phantom volume. Maximal Type I and Type II classification errors were low, ranging between 2.2 and 4.3% of phantom volume. The algorithm was also insensitive to variation in parameter initialization values. The protocol is robust, fast, and its success in segmenting normal as well as diseased brains makes it an attractive clinical application.

Adult↗

Quantifying head motion associated with motor tasks used in fMRI.

In functional magnetic resonance imaging (fMRI) studies, long experiment times and small intensity changes associated with brain activation frequently lead to image artifacts due to head motion. Methods to minimize and correct for head motion by restraint, fast imaging, and retrospective image registration are typically combined but do not completely solve the problem, particularly for specific patient populations. As an initial step toward optimizing future designs of head restraints and improving motion correction techniques, the head motion characteristics of groups of stroke subjects, age-matched controls, and young adults were investigated with the aid of an MR simulator and a highly accurate position tracking system. Position measurements were recorded during motor tasks involving either the hand or the foot. Head motion was strongly dependent on the subject group and less upon the task conditions based on ANOVA calculations (P < 0.05). The stroke subjects exhibited approximately twice the head motion compared to that of age-matched controls, and the latter's head motion was about twice that of young adults. Moreover, the range of head motion in stroke subjects over all tasks was approximately 2 +/- 1 mm, with the motion occurring predominantly as translation in the superior-inferior direction and pitch rotation (nodding). These results lead to several recommendations on the design of fMRI motor experiments and suggest that improved motion correction strategies are required to examine such patient populations comprehensively.

Adult↗

Interstitial ultrasound heating applicator for MR-guided thermal therapy.

The ability to control the shape of thermal coagulation was investigated for various interstitial heating applicators incorporating planar transducers and device rotation. Magnetic-resonance-compatible interstitial ultrasound applicators were constructed and the effects of ultrasound power, frequency, scan rate and heating time on lesion radius were studied in heating experiments in excised liver tissue. Continuous thermal lesions were generated by scanning heating applicators over a 180 angular sector. The region of thermal coagulation was restricted to the prescribed sector. Lesion radius increased with acoustic power and heating time and decreased with increasing frequency. The relationship between the temperature distribution generated by the applicator and the resulting thermal lesion was assessed with MRI. Analysis of MR temperature maps revealed that the temperature distribution could be measured accurately within 2 mm from the surface of the applicator, and the boundary of thermal coagulation was defined by a temperature of 54 +/- 12 degrees C. Calculations of temperature distributions indicated that slower scan rates can overcome the tendency of perfusion to reduce the radius of thermal lesion. This applicator design and delivery strategy make conformal interstitial heating possible.

Hot Temperature↗

Comparison of thermal damage calculated using magnetic resonance thermometry, with magnetic resonance imaging post-treatment and histology, after interstitial microwave thermal therapy of rabbit brain.

Clinical application of high-temperature thermal therapy as a treatment for solid tumours requires an accurate and close to real-time method for assessing tissue damage. Imaging methods that detect structural changes during heating may underestimate the extent of thermal damage. This is due to the occurrence of delayed damage manifested at tissue locations exposed to temperatures lower than those required to cause immediate structural changes. An alternative approach is to measure temperature and then calculate the expected damage based on the temperature history at each tissue location. Magnetic resonance (MR) imaging methods now allow temperature maps of the target and surrounding tissues to be generated in almost real-time. The aim of this work was to evaluate whether thermal damage zones calculated on the basis of MR thermometry maps measured during heating correspond to actual tissue damage as measured after treatment by histological methods and MR imaging. Four male rabbits were treated with high-temperature thermal therapy delivered in the brain by a single microwave antenna operating at 915 MHz. MR scanning was performed before, during and after treatment in a 1.5 T whole-body scanner. Temperature maps were produced using the proton resonance frequency (PRF) shift method of MR thermometry. In addition, conventional T1-weighted and T2-weighted spin-echo images were acquired after treatment. Thermal damage zones corresponding to cell death, microvascular blood flow stasis and protein coagulation were calculated using an Arrhenius analysis of the MR temperature/time course data. The calculated zones were compared with the lesions seen on histopathological examination of the brains which were removed within 6-8 h of treatment. The results showed that calculated damage zones based on MR thermometry agreed well with areas of damage as assessed using histology after heating was completed. The data suggest that real-time calculations of final expected thermal damage based on an Arrhenius analysis of MR temperature data may provide a useful method of real-time monitoring of thermal therapy when combined with conventional T2-weighted images taken after treatment.

Animals↗

Magnetic resonance imaging of thermal coagulation effects in a phantom for calibrating thermal therapy devices.

A material has been developed and tested that permanently records thermal response patterns from heating devices. The material consists of a mixture of polyacrylamide and 18% w/w bovine serum albumin. Thermal denaturation is complete when the local temperature exceeds 70 degrees C, causing a large reduction in the T2 of the material. Three-dimensional distributions of "thermal damage" can be assessed using standard magnetic resonance imaging sequences. The material works well with microwave heating devices and is adaptable for use with ultrasound, radio-frequency, or laser heating devices. Suggested uses include characterizing heating devices prior to treatment and developing new clinical applications for thermal therapies.

Acrylic Resins↗

Feasibility of linear arrays for interstitial ultrasound thermal therapy.

The feasibility of linear array transducers for interstitial ultrasound thermal therapy was evaluated. Theoretical acoustic power distributions were used to calculate spatial heating patterns using the bioheat transfer equation. The spatial heating patterns of linear array and single element planar rectangular transducers were compared. Scanned heating with both transducer geometries produced asymmetric heating volumes; however, a more uniform radial temperature profile with a sharper margin was achieved with linear arrays. Single element transducers produced excessive heating near the probe surface. Homogeneous blood flow is predicted to reduce the mean temperature within the heated region, with little effect on the spatial pattern.

Biophysical Phenomena↗

Quantifying tissue damage due to focused ultrasound heating observed by MRI.

Focused ultrasound heating of ex vivo bovine kidney and liver was monitored using magnetic resonance imaging (MRI) to investigate the quantitative relationship between time-dependent temperature elevations and altered contrast in MR images due to thermal coagulation. Proton resonance frequency shift MR thermometry was performed during heating at 10 sec intervals (single-slice fast spoiled GRASS [FSPGR], theta/TE/TR 30 degrees/11/39 msec, field of view 8 cm, 256 x 256, 3 mm slice thickness, 1 NEX); post-heating MR images were T1-weighted (3D-FSPGR, theta/TE/TR 60 degrees/25/200 msec, 1 mm slice thickness, 3 NEX). Analysis of the resulting temperature versus time data using the Arrhenius relationship and a simple binary discrimination model showed that thermal coagulation occurred with heating at approximately 54 degrees C for 10 sec in both tissues and could be predicted with approximately 625 microm spatial resolution. These results suggest that quantitative MR guidance of thermal coagulation therapy is feasible, and they provide information useful for designing future investigations in vivo.

Animals↗

Analysis of changes in MR properties of tissues after heat treatment.

To characterize changes in the MR parameters of tissues due to thermal coagulation, a series of T(1), T(2), diffusion, and magnetization transfer measurements were performed on a variety of ex vivo tissues: murine slow twitch skeletal muscle, murine cardiac muscle, murine cerebral hemisphere, bovine white matter, murine liver tissue, bovine retroperitoneal adipose tissue, hen egg white, human prostate and human blood. Standardized heat treatments were performed for each tissue type, over the temperature range from 37 degrees C to 90 degrees C. For all tissues, changes in each MR measurement resulting from thermal coagulation were observed above a threshold temperature of approximately 60 degrees C. These changes are explained based on biophysical knowledge of thermal damage mechanisms and the MR properties of normal tissues, and are particularly relevant for interpreting the changes in image contrast that are observed when MRI is used to guide and monitor thermal coagulation therapy procedures. Magn Reson Med 42:1061-1071, 1999.

Adipose Tissue↗

Characterizing white matter with magnetization transfer and T(2).

A magnetization-transfer (MT) CPMG hybrid experiment was performed to analyze T(2) relaxation and MT characteristics in bovine optic nerve. Two exchanging liquid pools with their own, independent MT characteristics were necessary to model both the T(2) relaxation and the MT data. The model agrees well with the experimental data and yields physically realistic parameters. The MT effect for myelin water is approximately nine time larger than that for intra/intercellular water, indicating that the MT characteristics observed for white matter are mainly related to myelin. The model can be used to probe parameters that would be difficult to achieve experimentally. The exchange process between the two tissue compartments does not drastically affect the amplitudes and relaxation rates of the T(2) components, but is fast enough to significantly influence their MT characteristics. Although, both the MT and T(2) experiments described in this paper are too time consuming to be applied in routine clinical work, presented results can be useful in interpreting clinical pulse sequences that are sensitive to myelin. Magn Reson Med 42:1128-1136, 1999.

Animals↗

Time and temperature dependence of MR parameters during thermal coagulation of ex vivo rabbit muscle.

Detailed measurements of the T1-weighted, T2-weighted, and MT-weighted signal were performed for ex vivo muscle samples heated to various temperatures for different times. Consistent, monotonic increases in signal intensity were observed with progressive thermal coagulation, corresponding to an increase in T2 relaxation time and an increase in MT-weighted signal for temperatures above 60 degrees C. The relationship for T1 relaxation was more complex, showing a decrease in T1 relaxation from 40 to 60 degrees C and an increase above 60 degrees C. These techniques provide a more direct measure of tissue thermal coagulation than that provided by MR thermometry and suggest MR imaging strategies for the optimization and monitoring of thermal coagulation therapy protocols that create thermal damage in target tissues.

Animals↗

Memory impairments associated with hippocampal versus parahippocampal-gyrus atrophy: an MR volumetry study in Alzheimer's disease.

Delayed memory impairments and medial temporal-lobe atrophy are considered to be cardinal features of Alzheimer's disease (AD). The goal of the present magnetic resonance (MR) volumetry study was to investigate the relationship between both features. We determined MR-derived estimates of hippocampal and parahippocampal volume in a sample of 27 AD patients and in a group of 26 healthy control subjects (NCs) of comparable age and education. We examined the performance of the two groups on immediate and delayed recall trials of an auditory-verbal list-learning task (CVLT), a visual non-verbal memory task (Visual Reproduction of the WMS-R), and a screening procedure that provides an estimate of overall cognitive functioning (DRS). Volumes of the hippocampus and the parahippocampal gyrus were significantly smaller in AD patients than in NCs. AD patients were impaired in their overall level of cognitive functioning and showed memory deficits under immediate and delayed recall conditions. The association between medial temporal-lobe atrophy and cognitive impairments in AD was found to be highly specific: Hippocampal volume correlated positively with delayed but not immediate recall of the verbal auditory list learning task. In contrast, parahippocampal gyrus volume, specifically in the right hemisphere, was positively related to delayed but not immediate recall of the non-verbal visual memory task. In NCs, there was a trend towards a negative association between hippocampal volumes and delayed verbal recall. Our results suggest that hippocampal and parahippocampal gyrus atrophy in AD are related to distinct aspects of the patients' memory impairments. Our findings have implications for current discussions regarding contributions of the hippocampus and the parahippocampal gyrus to memory in the intact human brain.

Aged↗

Magnetic resonance properties of ex vivo breast tissue at 1.5 T.

The magnetic resonance absorption spectrum, T1 and T2 relaxation time distributions, and magnetization transfer properties of ex vivo breast tissue have been characterized at 1.5 T and 37 degrees C. The fraction of fibroglandular tissue within individual tissue samples (n = 31) was inferred from the tissue volumetric water content obtained by integration of resolvable broad-line fat and water resonances. The spectroscopically estimated water content was strongly correlated with that extracted enzymatically (Pearson correlation coefficient 0.98, P < < 0.01), which enabled the assignment of principal relaxation components for fibroglandular tissue (T2=0.04+/-0.01, T1=1.33+/-0.24 s), and for adipose tissue (T2=0.13+/-0.01, T1=0.23+/-0.01 s, and T2=0.38+/-0.03, T1=0.62+/-0.16 s). Th e relaxation components for fibroglandular tissue exhibited strong magnetization transfer, whereas those for adipose tissue showed little magnetization transfer effect. These results ultimately have applicability to the optimization of clinical magnetic resonance imaging and research investigations of the breast.

Breast↗

Spatial- and object-based attentional deficits in Alzheimer's disease. Relationship to HMPAO-SPECT measures of parietal perfusion.

The purpose of this study was to investigate the ability of patients with Alzheimer's disease to shift attention between spatial locations and between objects, and to examine the brain regions involved in these cognitive operations using single photon emission computed tomography (SPECT) imaging. A recent study of patients with focal lesions provided evidence that the right and left parietal lobes are differentially involved in shifting selective attention from invalidly cued spatial locations and objects, respectively (Egly et al. J Exp Psychol Gen 1994; 123: 161-77). Accordingly, in Alzheimer's disease patients, we hypothesized that right parietal hypoperfusion on SPECT would be associated with deficits on the spatial-based component of a cued reaction time task, and left parietal hypoperfusion would be associated with the deficits on the object-based component. Attentional performance of Alzheimer's disease patients (n = 29) was compared with aged-matched normal controls (n = 17) using a cued reaction time task based on Egly et. al. (1994). Regions of interest were defined semi-automatically on SPECT, and were anatomically localized with the aid of co-registered MRI. As hypothesized, in Alzheimer's disease patients, reaction time costs of invalid targets eliciting shifts of attention between spatial locations were selectively correlated with SPECT hypoperfusion in the right superior parietal lobe; while reaction time costs of between-object shifts of attention were correlated with hypoperfusion in the left inferior parietal lobe. These results provide evidence for the specialized roles of the right and left parietal regions in the spatial and object components of attentional shifting respectively, and suggest that the cognitive profile associated with Alzheimer's disease includes both spatial- and object-based attentional impairments.

Aged↗

Magnetic resonance imaging of temperature changes during interstitial microwave heating: a phantom study.

Changes in magnetic resonance (MR) signals during interstitial microwave heating are reported, and correlated with simultaneously acquired temperature readings from three fiber-optic probes implanted in a polyacrylamide gel phantom. The heating by a MR-compatible microwave antenna did not interfere with simultaneous MR image data acquisition. MR phase-difference images were obtained using a fast two-dimensional-gradient echo sequence. From these images the temperature-sensitive resonant frequency of the 1H nuclei was found to decrease approximately by 0.008 ppm/ degree C. The method and results presented here demonstrate that noninvasive MR-temperature imaging can be performed simultaneously with interstitial microwave thermal treatment.

Biophysical Phenomena↗

Quantitative MR volumetry in Alzheimer's disease. Topographic markers and the effects of sex and education.

We determined topographic selectivity and diagnostic utility of brain atrophy in probable Alzheimer's disease (AD) and correlations with demographic factors such as age, sex, and education. Computerized imaging analysis techniques were applied to MR images in 32 patients with probable AD and 20 age- and sex-matched normal control subjects using tissue segmentation and three-dimensional surface rendering to obtain individualized lobar volumes, corrected for head size by a residualization technique. Group differences emerged in gray and white matter compartments particularly in parietal and temporal lobes. Logistic regression demonstrated that larger parietal and temporal ventricular CSF compartments and smaller temporal gray matter predicted AD group membership with an area under the receiver operating characteristic curve of 0.92. On multiple regression analysis using age, sex, education, duration, and severity of cognitive decline to predict regional atrophy in the AD subjects, sex consistently entered the model for the frontal, temporal, and parietal ventricular compartments. In the parietal region, for example, sex accounted for 27% of the variance in the parietal CSF compartment and years of education accounted for an additional 15%, with women showing less ventricular enlargement and individuals with more years of education showing more ventricular enlargement in this region. Topographic selectivity of atrophic changes can be detected using quantitative volumetry and can differentiate AD from normal aging. Differential effects of sex and years of education can also be detected by these methods. Quantification of tissue volumes in vulnerable regions offers the potential for monitoring longitudinal change in response to treatment.

Aged↗

Criteria for analysis of multicomponent tissue T2 relaxation data.

Monte Carlo simulations were performed to determine whether the multicomponent T2 distribution of tissue can be estimated accurately from T2 decay data acquired in vivo. Simulated data were generated for white matter, fast twitch muscle, and breast tissue. The signal-to-noise ratio, number of data samples, and minimum echo time were varied from the experimental conditions currently achievable with MRI to those achievable for in vitro experiments. Data were fitted by a distribution of T2 values using the T2NNLS algorithm, and statistics characterizing the estimated T2 components were determined. Current MRI techniques were found to provide conditions insufficient for accurate multicomponent T2 analysis on a pixel-by-pixel basis. However, volume localization methods that measure T2 decay from a large volume of interest have potential for this analysis. These results illustrate a general framework for development of new techniques to measure T2 decay accurately in vivo.

Brain Chemistry↗

MR measurement of relative water content and multicomponent T2 relaxation in human breast.

MR techniques providing accurate measurement of relative volumetric water content and multicomponent T2 relaxation times from a large volume of interest, have been implemented for characterization of breast tissue in vivo. In a sequence of 20-s breath-holds, data are obtained from much of the breast volume while suppressing signal from the chest wall and torso. Relative water content of each breast is calculated from one-dimensional fat and water profiles obtained using a hybrid two-point Dixon method (TE/TR = 17/5000 ms). Multicomponent T2 relaxation measurements are calculated from T2 decay curves obtained using a CPMG train of rectangular pulses (TE/TR = 8/5000 ms, 140 echoes) preceded by saturation pulses to localize longitudinal magnetization spatially. These techniques, validated in phantoms and human volunteers, are suitable for quantitative study of breast tissue in vivo, and in particular to investigate the potential role of MR for assessment of breast cancer risk.

Body Water↗

Quantitative correlation of breast tissue parameters using magnetic resonance and X-ray mammography.

Previous investigators have shown that there is a strong association between the fraction of fibroglandular tissue within the breast as determined by X-ray mammography (per cent density) and breast cancer risk. In this study, the quantitative correlation between per cent density and two objective magnetic resonance (MR) parameters of breast tissue, relative water content and mean T2 relaxation time, as investigated for 42 asymptomatic subjects. Using newly developed, rapid techniques MR measurements were performed on a volume-of-interest incorporating equal, representative portions of both breasts. X-ray mammograms of each subject were digitised and analysed semiautomatically to determine per cent density. Relative water content showed a strong positive correlation with per cent density (Pearson correlation coefficient rp = 0.79, P < 0.0001) and mean T2 value showed a strong negative correlation with per cent density (rp = -0.61, P < 0.0001). The MR and X-ray parameters were also associated with sociodemographic and anthropometric risk factors for breast cancer (P < 0.05). The potential use of MR parameters to assess risk of breast cancer and to provide a frequent, non-hazardous monitor of breast parenchyma is discussed.

Adipose Tissue↗