A new hydrogen peroxide--based medical-device detergent with germicidal properties: comparison with enzymatic cleaners.

BACKGROUND: The objective of this study was to evaluate the efficacy of the cleaning and bacterial killing ability of a new non-enzyme-based formulation (killing detergent solution [KDS]) compared with commercially available enzymatic detergents that included Metrizyme (Metrex Research Division of Sybron Canada Ltd. Morrisburg, Ontario) and Gzyme (Germiphene Corp, Brantford, Ontario). KDS is a hydrogen peroxide-based detergent formulation that combines cleaning efficacy with the ability to kill microorganisms. The KDS formulation helps ensure the protection of the health care worker from infectious risk during the soaking and cleaning stages of medical device reprocessing and reduces the bioburden on devices before sterilization/disinfection. METHODS: Test organisms that included Enterococcus faecalis, Salmonella choleraesuis, Staphylococcus aureus, and Pseudomonas aeruginosa were suspended in artificial test soil (ATS-B; patent submitted), inoculated at 10(6) colonyforming units per carrier and dried overnight before detergent exposure. The ATS-B mimics the blood, protein, carbohydrate, and endotoxin levels of patient-used medical devices. Plastic lumen carriers and a flexible colonoscope were used for surface and simulated-use testing, respectively. RESULTS: The results for the microbial challenge dried onto polyvinyl chloride (PVC) carriers demonstrated that the ability of KDS to remove protein, blood, carbohydrate, and endotoxin from surface test carriers was as effective as the enzyme detergents that were evaluated. Furthermore, KDS was able to effect approximately a 5-Log(10) reduction in microbial loads with a 3-minute exposure at room temperature, whereas none of the other detergents were as effective. In simulated-use testing of a soiled colonoscope, KDS was significantly better at ensuring microbial killing compared with Gzyme and Metrizyme and was equivalent to the enzymatic detergents in cleaning ability. CONCLUSIONS: In summary the KDS has excellent microbial-killing ability in 3-minute exposures at room temperature and cleans as well as the existing enzymatic detergent formulations that were tested.

Detergents↗

Etiology of genital ulcer disease in Dakar, Senegal, and comparison of PCR and serologic assays for detection of Haemophilus ducreyi.

We used PCR assays to determine the etiology of genital ulcers in patients presenting to a sexually transmitted disease clinic in Dakar, Senegal, and evaluated the ability of two PCR tests (groEL and recD) and two serological tests (adsorption enzyme immunoassay [EIA] and lipooligosaccharide [LOS] EIA) to detect current Haemophilus ducreyi infection. We found that in this population, H. ducreyi, T. pallidum, and herpes simplex virus HSV DNA were detected in 56, 15, and 13% of 39 genital ulcer specimens, respectively, and H. ducreyi DNA was detected in 60% (3 of 5) of samples from ulcerated bubos. Among 40 consecutive patients with genital ulcer disease and with sufficient sample for both PCR assays, the recD and groEL H. ducreyi PCR assays were 83% concordant, with the recD PCR assay detecting six (15%) additional positive specimens and the groEL assay detecting one (3%) additional positive specimen. Compared to PCR, the adsorption EIA and LOS EIA tests had sensitivities of 71 and 59% and specificities of 57 and 90%, respectively, for the diagnosis of current H. ducreyi infection. While these differences in specificity could be due either to previous infection with H. ducreyi or to the detection of cross-reacting antibodies, only 6% of patients from a nearby family planning clinic gave a positive reaction in both the adsorption EIA and LOS EIA assays, indicating that cross-reacting antibodies are not prevalent among clinic attendees in this city. Our studies indicate that the adsorption EIA detects both current and past infection, while the LOS EIA assay is more specific for current infection with H. ducreyi in this population.

Adult↗

Characterization of a toxin A-negative, toxin B-positive strain of Clostridium difficile responsible for a nosocomial outbreak of Clostridium difficile-associated diarrhea.

Clostridium difficile-associated diarrhea (CAD) is a very common nosocomial infection that contributes significantly to patient morbidity and mortality as well as to the cost of hospitalization. Previously, strains of toxin A-negative, toxin B-positive C. difficile were not thought to be associated with clinically significant disease. This study reports the characterization of a toxin A-negative, toxin B-positive strain of C. difficile that was responsible for a recently described nosocomial outbreak of CAD. Analysis of the seven patient isolates from the outbreak by pulsed-field gel electrophoresis indicated that this outbreak was due to transmission of a single strain of C. difficile. Our characterization of this strain (HSC98) has demonstrated that the toxin A gene lacks 1.8 kb from the carboxy repetitive oligopeptide (CROP) region but apparently has no other major deletions from other regions of the toxin A or toxin B gene. The remaining 1.3-kb fragment of the toxin A CROP region from strain HSC98 showed 98% sequence homology with strain 1470, previously reported by M. Weidmann in 1997 (GenBank accession number Y12616), suggesting that HSC98 is toxinotype VIII. The HSC98 strain infecting patients involved in this outbreak produced the full spectrum of clinical illness usually associated with C. difficile-associated disease. This pathogenic spectrum was manifest despite the inability of this strain to alter tight junctions as determined by using in vitro tissue culture testing, which suggested that no functional toxin A was produced by this strain.

Adolescent↗

Methodology of reprocessing reusable accessories.

Accessory devices used for gastrointestinal endoscopy are often complex and because they enter sterile body cavities, or contact blood because of invasive procedures, they should be sterile before being used for a patient procedure. The complexity of such reusable accessory devices is reviewed, and the critical aspects of cleaning, sterilization, and quality assurance are discussed. The effectiveness of adequate reprocessing between patient use is critical to prevent transmission of infectious diseases from one patient to another.

Endoscopes, Gastrointestinal↗

Worst-case soiling levels for patient-used flexible endoscopes before and after cleaning.

BACKGROUND: The soiling levels of patient-used narrow-lumened flexible endoscopes were assessed for bronchoscopes, duodenoscopes, and colonoscopes. The effect of cleaning on the soil composition and concentration was evaluated. DESIGN: Suction channels from 10 each of bronchoscopes, duodenoscopes used for endoscopic retrograde cholangiopancreatography, and colonoscopes were assessed immediately after patient use for the levels of bilirubin, hemoglobin, protein, sodium ion, carbohydrate, endotoxin, and viable bacteria. Another 10 suction channels of each type of endoscope were evaluated for the same components after routine cleaning but before processing by high-level disinfection or sterilization for subsequent clinical use. RESULTS: Recognizing that only soluble components could be quantified, the worst-case soil levels in the suction channels (the average surface area of these channels was 45.6 cm(2), 149.8 cm,(2) and 192.0 cm(2) for bronchoscopes, duodenoscopes, and colonoscopes, respectively) were protein 115 microg/cm(2), sodium ion 7.4 micromol/cm(2), hemoglobin 85 microg/cm(2), bilirubin 299 nmol/cm(2), carbohydrate 29.1 microg/cm(2), endotoxin 9852 endotoxin units/cm(2), and bacteria 7.1 (log(10)) colony-forming units (CFU)/cm(2). Colonoscopes had 4 to 5 times greater soiling on average compared with the other endoscope types. Routine cleaning reduced the levels of bilirubin to below the limits of detection for all endoscopes evaluated (limits of detection were <1 nmol/mL). After cleaning, residual hemoglobin was detectable in bronchoscopes only. After cleaning, the levels of protein, endotoxin, and sodium ion all were reduced fivefold to tenfold for all types of endoscopes. Carbohydrate was reduced to lower than the limit of detection for all endoscopes after cleaning, except the duodenoscopes. The average load of viable bacteria was reduced from 3 log(10) to 5 log(10) CFU/cm(2) (which represents 5.9-9.5 log(10) CFU/endoscope channel) after patient use to approximately 2 log(10) CFU/cm(2) (which represents 3.2-5.3 log(10) CFU/endoscope channel) after cleaning. CONCLUSIONS: These data demonstrated that cleaning effectively reduced or eliminated many components of soil, but a substantial amount of viable bacteria and protein remained. Hemoglobin levels in before samples indicated that blood was not present in high concentrations in the suction channels of the majority of flexible endoscope samples. Soil that mimics the worst-case composition from patient-used endoscopes would be ideal for simulated-use studies for such medical devices.

Bronchoscopes↗

E test versus agar dilution for antimicrobial susceptibility testing of viridans group streptococci.

Viridans group streptococci (VGS) are commonly isolated from the blood of hospitalized patients. The E test represents a convenient method for determining the MICs for VGS, but for this purpose it has not been well validated against reference methods. In this study, 180 unselected VGS isolates were identified to a species level, and the MICs of penicillin, cefuroxime, cefotaxime, and vancomycin were determined by both agar dilution and the E test. Available data regarding demographic and laboratory variables for each VGS bacteremic episode were collected, the significance of each VGS isolate was assessed, and the associations between and among laboratory and clinical variables were investigated. Among all VGS isolates, 68.3% (median of three runs) were found to be fully susceptible to penicillin by agar dilution. The E test and agar dilution showed average agreements (within +/-1 dilution) of 92.2% for penicillin, 95.7% for cefuroxime 91.3% for cefotaxime, and 86.7% for vancomycin. Agreements over serial E tests and serial agar dilutions were excellent for beta-lactam agents (intraclass correlation coefficients, >0.9) but less impressive for vancomycin. Very major error rates for the E test were </=0.7%, and combined major and minor error rates were within acceptable limits for all antimicrobial agents tested. Lysis-centrifugation culture methods were more often associated with clinically insignificant VGS isolates; otherwise, no associations between clinical and laboratory variables were noted.

Anti-Bacterial Agents↗

Comparison of liquid chemical sterilization with peracetic acid and ethylene oxide sterilization for long narrow lumens.

The aim of this study was to determine how well peracetic acid liquid chemical sterilization (LCPAS) killed test organisms in the presence of 10% fetal bovine serum and 0.65% salt challenge (RPMI-S) compared with a 100% ethylene oxide (ETO) sterilizer and an ETO hydrochlorofluorocarbon (ETO-HCFC) sterilization method with long (125 cm), narrow (3-mm internal diameter) flexible lumens as the test carrier. The inoculated lumens were dried overnight before processing. The test organisms included Mycobacterium chelonei, Enterococcus faecalis, and Bacillus subtilis. For all 3 organisms tested, the LCPAS process resulted in a 6 log10 reduction in bacterial load compared with a 2.5 log10 to 6 log10 reduction for the 100% ETO and ETO-HCFC sterilizers. Sterilization was achieved for 100%, 61%, and 67% of the lumen test carriers for the LCPAS, 100% ETO, and ETO-HCFC sterilizers, respectively. The data indicate that of the sterilization methods evaluated, LCPAS was the most effective for sterilizing narrow flexible lumens in the presence of residual inorganic and organic soil. This effectiveness was achieved through a combination of organism wash-off and peracetic acid sterilant killing of organisms. Salt was the major compounding factor for effective ETO gas sterilization, because carriers inoculated with organisms in 10% fetal bovine serum alone all were sterilized by both 100% ETO and ETO-HCFC sterilization methods. Our data support the critical need to ensure adequate precleaning of narrow flexible lumen endoscopes before any sterilization method.

Bacillus subtilis↗

Survey of incidence of Clostridium difficile infection in Canadian hospitals and diagnostic approaches.

A questionnaire relating to Clostridium difficile disease incidence and diagnostic practices was sent to 380 Canadian hospitals (all with > 50 beds). The national questionnaire response rate was 63%. In-house testing was performed in 17.6, 61.5, and 74.2% of the hospitals with < 300, 300 to 500, and > 500 beds, respectively. The average test positivity rates were 17.2, 15.3, and 13.2% for hospitals with < 300, 300 to 500, and > 500 beds, respectively. The average disease incidences were 23.5, 30.8, and 40.3 cases per 100,000 patient days in the hospitals with < 300, 300 to 500, and > 500 beds, respectively. In the 81 hospitals where in-house testing was performed, cytotoxin testing utilizing tissue culture was most common (44.4%), followed by enzyme-linked immunosorbent assay (38.3%), culture for toxigenic C. difficile (32.1%), and latex agglutination (13.6%). The clinical criteria for C. difficile testing were variable, with 85% of hospitals indicating that a test was done automatically if ordered by a doctor. Our results show that C. difficile-associated diarrhea is a major problem in hospitals with > or = 200 beds. Despite a lower disease incidence in smaller hospitals, there was a higher diagnostic test positivity rate. This may reflect the preference of smaller hospitals for culture and latex agglutination tests.

Bacterial Proteins↗

Attachment of Haemophilus ducreyi to human foreskin fibroblasts involves LOS and fibronectin.

Haemophilus ducreyi is the causative agent of the genital ulcer disease Chancroid. Chancroid has been shown to increase the risk of heterosexual transmission of HIV. Little is known regarding the attachment or localization of this organism to human cells in either the dermal or epidermal layer. In this study the attachment of H. ducreyi to human foreskin fibroblast (HFF) cells was further characterized. Attachment was mediated by more than one mechanism. Proteinase K treatment but not trypsinization of H. ducreyi significantly reduced attachment suggesting protein involvement. In addition, purified lipooligosaccharide (LOS) was able to inhibit attachment in a dose dependent manner. It appeared that the organism binds to fibronectin in the extracellular matrix of HFF cells, since competition studies using fibronectin showed that it was able to significantly reduce attachment in a dose dependent manner whereas collagen did not. We hypothesize that the attachment of H. ducreyi involves both a protein mediator of attachment (likely pili) as well as LOS and that one or both of these bacterial components interacts with fibronectin in the extracellular matrix to mediate attachment to HFF cells.

Antibodies, Monoclonal↗

Bacterial killing ability of 10% ethylene oxide plus 90% hydrochlorofluorocarbon sterilizing gas.

OBJECTIVES: To use a serum and salt challenge in narrow-lumen carriers to evaluate a 10% ethylene oxide plus 90% hydrochlorofluorocarbon (EO-HCFC) sterilant mixture in a retrofitted 12/88 sterilizer as an alternative to the banned chlorofluorocarbon-ethylene oxide (EO) sterilant mixture. DESIGN: An EO-HCFC sterilizing gas mixture in a retrofitted 12/88 sterilizer was compared to 100% ethylene oxide (100% EO) sterilizing gas to determine its relative ability to kill seven different bacteria (Escherichia coli, Pseudomonas aeruginosa, Enterococcus faecalis, Bacillus subtilis spores, Bacillus stearothermophilus spores, Bacillus circulans spores, and Mycobacterium chelonei) in the presence or absence of a combined 10% serum and 0.65% salt challenge using both penicylinders (PC) and long narrow-lumen (LU) carriers. RESULTS: The EO-HCFC sterilant mixture (96% sterile carriers) was equivalent to the 100% EO sterilant (98% sterile carriers) for killing vegetative organisms, as well as spore suspensions, on the 27 PC and 27 LU carriers in the absence of serum and salt. In the presence of serum and salt, the EO-HCFC sterilant mixture was markedly better than the 100% EO sterilant at reducing the bacterial load on the 63 PC carriers (95% vs 62% sterile PC carriers, respectively), whereas both sterilizers were equivalent for the 63 LU carriers (49% vs 40% sterile LU carriers, respectively). Of the seven test organisms, E faecalis, B subtilis, B stearothermophilus, and B circulans were the most difficult to kill for both PC and LU carriers when serum and salt were present. CONCLUSIONS: The data presented in this report indicate that the EO-HCFC sterilant mixture is an effective alternative for gas sterilization. Indeed, the efficiency of bacterial killing for the EO-HCFC sterilant mixture was similar to that achieved by the 12/88 EO-CFC sterilant mixture.

Bacteria↗

Improved detection of bacterial growth in continuous ambulatory peritoneal dialysis effluent by use of BacT/Alert FAN bottles.

Culture-negative peritonitis is a major complication for patients on continuous ambulatory peritoneal dialysis (CAPD) and precludes organism-specific therapy. The aim of the present study was to compare inoculation of 10 ml of CAPD effluent into BacT/Alert blood culture bottles (FAN [fastidious antimicrobic neutralizing], BacTAlert aerobic [BTA], and BacT/Alert anaerobic [BTAn] bottles) to our conventional method of using 50 ml of concentrated CAPD effluent to inoculate peptone broth bottles (BD bottles) and MacConkey agar and blood agar medium (BA-MAC). The FAN, BTA, and BTAn bottles were monitored automatically in the BacT/Alert blood culture instrument. A total of 207 CAPD effluents were studied, and in 97 bacteria were detected by at least one method. Compared to BTA bottles (79 of 97; 81.4%), BTAn bottles (78 of 97; 80.4%), and BD bottles (88 of 97; 90.7%), the single best broth medium for detecting bacterial growth in CAPD effluents was the FAN bottle (90 of 97 effluents; 92.8%). A total of 125 bacterial species were detected by any method, and the majority (91.8%) of CAPD effluents were infected with a single species. A combination of FAN and BTAn bottles detected 111 of 125 (88.8%) of all organisms, whereas a combination of BD bottles and BA-MAC detected 107 of 125 (85.6%) of all organisms. One or more organisms that would have been completely missed by the conventional method with BD bottles and BA-MAC were detected in 18 CAPD effluents. Of these 18 CAPD effluents, 6 showed no growth by the conventional method with BD bottles and BA-MAC. On the basis of our data, the most sensitive and least labor intensive method was direct inoculation of 10 ml of CAPD effluent into a FAN bottle and a BTAn bottle, which could be automatically monitored by the BacT/Alert blood culture instrument. On the basis of case definitions for peritonitis, the sensitivities and specificities of the methods with FAN and BTAn bottles and with BD bottles and BA-MAC were 81.1 and 98.8% and 74.5 and 96.5%, respectively.

Bacteria↗

Comparison of ion plasma, vaporized hydrogen peroxide, and 100% ethylene oxide sterilizers to the 12/88 ethylene oxide gas sterilizer.

OBJECTIVE: The performance of a standard gas sterilizer, which uses a mixture of 12% ethylene oxide (EtO) and 88% chlorofluorocarbon as the sterilizing gas (12/88), was compared to selected gas, ion plasma, and vaporized hydrogen peroxide (H2O2) sterilizers that do not use chlorofluorocarbons. The effect of serum and salt on sterilizer performance was evaluated. DESIGN: Test carriers (porcelain and stainless steel penicylinders, or 125-cm lengths of plastic tubing [internal diameter of 3.2 mm]) were inoculated with Escherichia coli, Enterococcus faecalis, Pseudomonas aeruginosa, Mycobacterium chelonei, Bacillus stearothermophilus spores, Bacillus subtilis spores, and Bacillus circulans spores and then subjected to sterilization using 12/88, 100% EtO, ion plasma, or vaporized H2O2. The bacterial inoculum was prepared with and without 10% serum and 0.65% salt, and the residual bacterial load after sterilization as determined using viable counts. RESULTS: All of the sterilizers tested effected a six-log10 reduction of the bacterial inoculum on penicylinders, unless 10% serum and 0.65% salt were present, in which case the 100% EtO, vaporized H2O2, and ion plasma sterilizers were not as effective as the 12/88 sterilizer. None of the sterilizers could eradicate 10(6) CFU of all of the bacteria in 10% serum and 0.65% salt when inoculated inside a narrow lumen. CONCLUSIONS: The margin of safety for the 100% EtO, vaporized H2O2, and ion plasma sterilizers is less than that of the 12/88 sterilizer. The inability of all sterilizers, including the 12/88, to kill organisms in narrow lumens reliably when serum and salt were present raises concern about the current practice of gas sterilization of flexible endoscopes.

Analysis of Variance↗

Mycobacterium abscessus infection of a Norplant contraceptive implant site.

The authors report a case of Mycobacterium abscessus infection of a subdermal levonogestrel implant (Norplant) site. The infection lasted 12 weeks and was indolent, skin manifestations were low grade and difficult to detect. Culture of exudate samples showed that M. abscessus was the only causative agent. After the implant was removed the patient's arm healed uneventfully without antimycobacterial therapy. The authors recommend that if Gram staining of apparently infected material from an implant site does not reveal a causative organism, then cultures should be done for mycobacteria and fungi. Kinyoun staining for acid-fast bacteria and calcoflour-white staining for fungi should also be performed. The implant should be removed and the patient given antimicrobial therapy as indicated. The authors emphasize the need to be aware of the potential for M. abscessus infection of implant sites and stress that appropriate microbiologic culture procedures are essential for accurate diagnosis.

Adult↗