Search PubMed⌕ Search

Biomedical subjects

M Iijima

Publications and source records attributed to M Iijima.

At least 37 records · Page 2Linked to original sources

Assembly of amelogenin proteolytic products and control of octacalcium phosphate crystal morphology.

The formation of enamel apatite crystals involves extracellular molecular events among which matrix assembly, interactions with growing crystals, and protein processing and removal are the subject of numerous investigations. Following the description of amelogenin nanospheres and the evidence for their presence in vivo as the principal structural component of developing dental enamel, we have focused our studies on investigating at the molecular level the process of nanosphere assembly and evaluating the effects of amelogenin on crystal growth and morphology. This paper is a short review of our recent studies with a focus on the assembly of amelogenin proteolytic products and their modulating effect on octacalcium phosphate (OCP) crystal morphology. In addition, we report that incorporation of amelogenins into 10% gelatin gel does not affect diffusion of calcium. This remarkable finding indicates that the observed modulation effect by amelogenin on OCP crystal morphology is not due to alteration of calcium diffusion into the gels but is the result of direct amelogenin-mineral interactions.

Amelogenin↗

Mechanical behavior at different temperatures and stresses for superelastic nickel-titanium orthodontic wires having different transformation temperatures.

OBJECTIVE: The purpose of this study was to investigate the mechanical properties of superelastic nickel-titanium orthodontic wires under controlled stress and temperature. METHODS: Three different superelastic nickel-titanium wires were examined using differential scanning calorimetry (DSC), three-point bending test and micro X-ray diffraction (micro-XRD). The three-point bending test was carried out at constant temperature (23, 37 and 60 degrees C) and stepwise temperature changes (37-60 degrees C and to 37 degrees C) (37-2 degrees C and to 37 degrees C). Five specimens of each wire were tested. Micro-XRD spectra were measured at the tension side of the wire when the temperature changed from 37 to 60 degrees C or 2 degrees C. RESULTS: The load during the stepwise temperature changes (37-2 degrees C and to 37 degrees C) was consistent with that measured at a corresponding constant temperature. The micro XRD spectrum clearly showed that the austenite phase was transformed to martensite phase when the temperature is decreased from 37 to 2 degrees C. In a stepwise temperature change (37-60 degrees C and to 37 degrees C), the load became higher than the original load at each corresponding constant temperature. However, there was no detectable change in the micro-XRD spectrum when the temperature was increased from 37 to 60 degrees C. SIGNIFICANCE: The superelastic nickel-titanium wires exhibited complicated and unexpected mechanical properties under stepwise temperature change. This study shows the possibility of qualitative analysis using micro-XRD to understand mechanical properties of these nickel-titanium wires.

Calorimetry, Differential Scanning↗

Micro X-ray diffraction study of superelastic nickel-titanium orthodontic wires at different temperatures and stresses.

The phase transformation behavior in three commercial nickel-titanium orthodontic wires having different transformation temperatures was studied by micro X-ray diffraction (micro-XRD). Micro-XRD spectra were obtained at three different included bending angles (135 degrees, 146 degrees and 157 degrees) and three different temperatures (25 degrees C, 37 degrees C and 60 degrees C). The regions analyzed by micro-XRD were within the separate areas of a given wire specimen that experienced only tensile or compressive strain. The intensity ratio (M002/A110) between the 002 peak for martensitic NiTi and the 110 peak for austenitic NiTi was employed as the index to the proportions of the martensite and austenite phases. The ratio of martensite to austenite increased in all three nickel-titanium wires with decreasing included bending angle (greater permanent bending deformation), and was lower within the compression area for all wires at all bending angles than within the tension area. Micro-XRD provides an effective method for quantitative evaluation of the proportions of these two phases in nickel-titanium orthodontic wires, even though considerable preferred crystallographic orientation exists because of the wire drawing process.

Alloys↗

Differential scanning calorimetric studies of nickel titanium rotary endodontic instruments.

Differential scanning calorimetric (DSC) analyses were performed between -130 degrees and 100 degrees C on specimens prepared from nickel-titanium (NiTi) rotary endodontic instruments: ProFile (n = 5), Lightspeed (n = 4), and Quantec (n = 3). The ProFile and Lightspeed instruments were in the as-received condition, whereas the Quantec instruments were randomly selected from a dental clinic and had unknown history. The DSC plots showed that the ProFile and Lightspeed instruments analyzed had the superelastic NiTi property, with an austenite-finish (Af) temperature of approximately 25 degrees C. Differences in DSC plots for the ProFile instruments and the starting wire blanks (n = 2) were attributed to the manufacturing process. The phase transformation behavior when the specimens were heated and cooled between -130 degrees and 100 degrees C, the temperature ranges for the phase transformations, and the resulting enthalpy changes were similar to those previously reported for nickel-titanium orthodontic wires having superelastic characteristics or shape memory behavior in the oral environment. The experiments demonstrated that DSC is a powerful tool for materials characterization of these rotary instruments, providing direct information not readily available from other analytical techniques about the NiTi phases present, which are fundamentally responsible for their clinical behavior.

Calorimetry, Differential Scanning↗

Differential scanning calorimetric studies of nickel-titanium rotary endodontic instruments after simulated clinical use.

Differential scanning calorimetric (DSC) analyses have been performed between -130 degrees and 100 degrees C on single-segment specimens obtained from ProFile and Lightspeed nickel-titanium rotary endodontic instruments in the as-received condition and after one, three, and six periods of simulated clinical use in extracted teeth. The DSC analyses showed that both brands of instruments were always in the superelastic condition, although the enthalpy values for the transformation from martensitic NiTi to austenitic NiTi were much smaller for the Lightspeed instruments. Simulated clinical use had no evident effect upon this transformation for both brands, which is attributed to insufficient mechanical deformation of the instruments. There were substantial differences in the enthalpy change associated with the transformation from martensitic NiTi to austenitic NiTi for test segments from different positions along the shafts of the instruments and for as-received instruments from two different batches that were analyzed in this study and a previous study. These differences are attributed to variations in work hardening along the shaft during instrument fabrication and to processing differences during production of the two batches of each instrument brand.

Calorimetry, Differential Scanning↗

Elongated growth of octacalcium phosphate crystals in recombinant amelogenin gels under controlled ionic flow.

Amelogenin proteins constitute the primary structural entity of the extracellular protein framework of the developing enamel matrix. Recent data on the interactions of amelogenin with calcium phosphate crystals support the hypothesis that amelogenins control the oriented and elongated growth of enamel carbonate apatite crystals. To exploit further the molecular mechanisms involved in amelogenin-calcium phosphate mineral interactions, we conducted in vitro experiments to examine the effect of amelogenin on synthetic octacalcium phosphate (OCP) crystals. A 10% (wt/vol) recombinant murine amelogenin (rM179, rM166) gel was constructed with nanospheres of about 10- to 20-nm diameter, as observed by atomic force microscopy. The growth of OCP was modulated uniquely in 10% rM179 and rM166 amelogenin gels, regardless of the presence of the hydrophilic C-terminal residues. Fibrous crystals grew with large length-to-width ratio and small width-to-thickness ratio. Both rM179 and rM166 enhanced the growth of elongated OCP crystals, suggesting a relationship to the initial elongated growth of enamel crystals.

Amelogenin↗

Citrin and aralar1 are Ca(2+)-stimulated aspartate/glutamate transporters in mitochondria.

The mitochondrial aspartate/glutamate carrier catalyzes an important step in both the urea cycle and the aspartate/malate NADH shuttle. Citrin and aralar1 are homologous proteins belonging to the mitochondrial carrier family with EF-hand Ca(2+)-binding motifs in their N-terminal domains. Both proteins and their C-terminal domains were overexpressed in Escherichia coli, reconstituted into liposomes and shown to catalyze the electrogenic exchange of aspartate for glutamate and a H(+). Overexpression of the carriers in transfected human cells increased the activity of the malate/aspartate NADH shuttle. These results demonstrate that citrin and aralar1 are isoforms of the hitherto unidentified aspartate/glutamate carrier and explain why mutations in citrin cause type II citrullinemia in humans. The activity of citrin and aralar1 as aspartate/glutamate exchangers was stimulated by Ca(2+) on the external side of the inner mitochondrial membrane, where the Ca(2+)-binding domains of these proteins are localized. These results show that the aspartate/glutamate carrier is regulated by Ca(2+) through a mechanism independent of Ca(2+) entry into mitochondria, and suggest a novel mechanism of Ca(2+) regulation of the aspartate/malate shuttle.

Amino Acid Transport Systems, Acidic↗

Sex differences in children's free drawings: a study on girls with congenital adrenal hyperplasia.

Sex differences are recognized in children's free drawings with respect to motifs, colors, figure compositions, and expression. Boys tend to draw mobile objects and mechanical objects with dark or cold colors and often use bird's-eye-view composition when they draw pictures, whereas girls like to draw human motifs (especially girls and women), flowers, and butterflies with light and warm colors and tend to arrange motifs in a row on the ground. Analyses were made on the drawings of girls with congenital adrenal hyperplasia (CAH) and unaffected boys and girls, using masculine and feminine indexes. Sex difference in masculine and feminine indexes was clear in the drawings by unaffected boys and girls. Their drawings do not or mostly do not contain characteristics typical of the opposite sex. Compared with those of unaffected girls, the pictures of CAH girls more strongly showed masculine characteristics. The feminine index for the pictures of CAH girls was significantly lower than that for unaffected girls, while the masculine index for CAH girls was significantly higher than that for unaffected girls. Furthermore, the masculine index for CAH girls was not significantly different from that of unaffected boys. These results suggest that androgen exposure during fetal life may contribute to shaping masculine characteristics in children's free drawings.

Adrenal Hyperplasia, Congenital↗

Adverse effect of dentine bonding agent on the oral mucosa of guinea pigs.

The purpose of present study was to determine the possibility of nebulous discoloration of the oral mucosa of guinea pigs as a result of the application of dentine bonding agents. The materials used were the Clearfil Photo Bond (CPB) system's mixture agent, universal agent and catalyst agent. Four types of experimental catalysts were used. In male albino guinea pigs weighing 300-500 g, oral mucosa irritation tests were performed in accordance with the guidelines of the Cosmetic, Toiletry and Fragrance Association (CTFA). Macroscopical findings on the oral mucosa showed that there was strong nebulous discoloration immediately after application of CPB mix and CPB catalyst and throughout the experimental periods. However, CPB without 10-methacryloxdecyl dihydrogen phosphate (MDP) did not produce noticeable nebulous discoloration and inflammation. The CPB mix caused pathological changes, such as paraketosis and hyperkeratosis on the endepidermis of the mucosa, immediately after its application.

Animals↗

Photocontact dermatitis to ketoprofen.

A case of photocontact dermatitis from ketoprofen is described in a 19-year-old woman with a 3-day history of pruritic lesions on the right forearm. Physical examination revealed a 105 x 46 mm, dark reddish lesion consisting of edematous erythema and papules on the extensor aspect of the right forearm. In photopatch testing, positive reactions to as-is (Mohrus compress [Hisamitsu Pharmaceutical Co, Inc, Tosu, Japan]), ketorofen 1% in petrolatum (pet.), suprofen 1% pet., and tiaprofenic acid 1% pet. were seen. We must consider the anatomic sites on which nonsteroidal anti-inflammation medicaments are applied, as well as their effects.

Adult↗

Changes in Ca2+ signaling and contractile protein isoforms in smooth muscle cells from guinea pig ileum during culture.

Single smooth muscle cells (SMCs) isolated from guinea pig ileum using collagenase and papain were cultured on laminin-coated dishes in MEM containing fetal calf serum. Temporal changes in intracellular calcium ion concentration in response to carbachol and to ATP were investigated using fluo-3/AM and fluorescence microscopy. It was observed that carbachol caused an increased intracellular calcium ion in freshly isolated single SMCs but a reduced or negative response of cultured SMCs before confluence. On the other hand, ATP was observed to cause an increase in the calcium ion content of SMCs throughout the culture. SDS-PAGE and Western blot analyses revealed changes in the expression of contractile proteins as follows. l-Caldesmon and non-muscle type myosin heavy chain (NMHC) (considered to be marker molecules for dedifferentiation in smooth muscle cells) and non-muscle type tropomyosin were not observed in freshly isolated single SMCs. l-Caldesmon and NMHC appeared in the cultured SMCs within 2 days and the tropomyosin isoform was observed 6 days following seeding. Simultaneously, smooth muscle type myosin heavy chain (SMHC) decreased strikingly and the 41 kDa tropomyosin monomer was lost. The content of alpha-actin decreased gradually to a minimum on day 6 when non-muscle type tropomyosin appeared, and the cells began to proliferate rapidly. These results suggest that the loss of contractility in cultured smooth muscle cells is more closely related to changes in contractile protein profiles than to receptor-mediated signal transduction and that in addition to NMHC and l-caldesmon, non-muscle type tropomyosin may be useful as a marker molecule for de-differentiation of smooth muscle cells.

Actins↗

Deep rooting in winter wheat: rooting nodes of deep roots in two cultivars with deep and shallow root systems.

Deep rooting of wheat has been suggested that it influences the tolerance to various environmental stresses. In this study, the nodes from which the deepest penetrated roots had emerged were examined in winter wheat. The wheat was grown in long tubes with or without mechanical stress and in large root boxes. The length and growth angle of each axile root were examined to analyze the difference in the vertical distribution of the roots between the two wheat cultivars, one with a deep and one with a shallow root system. In Shiroganekomugi, a Japanese winter wheat cultivar with a shallow root system, the rooting depths of the seminal and nodal roots decreased as the rooting nodes advanced acropetally. Six out of nine deepest roots were seminal root in the non-mechanical stress conditions. In Mutsubenkei, a Japanese winter wheat cultivar with a deep root system, grown in root boxes, not only the seminal roots but also the coleoptilar and the first nodal roots penetrated to a depth of more than 1.3 m in the root box, and became the deepest roots. In both cultivars, the seminal roots became the deepest roots under the mechanical stress conditions. There were no clear tendencies in the root growth angles among the rooting nodes in the wheat root system. This indicates that the length of the axile roots can explain the differences in the rooting depths among axile roots in a wheat root system. On the other hand, the axile roots of Mutsubenkei elongated significantly more vertically than those of Shiroganekomugi. This suggests that not only seminal but also nodal roots exhibit strong positive gravitropism and penetrate deeply in a cultivar with a deep root system. In wheat cultivars, it is likely that the extent of its Root Depth Index results partly from the gravitropic responses of both seminal and nodal roots.

Acclimatization↗

Corrosion behavior and surface structure of orthodontic Ni-Ti alloy wires.

The corrosion behaviors of a commercial Ni-Ti alloy orthodontic wire and a polished plate with same composition in 0.9% NaCl and 1% lactic acid solutions were examined using an electrochemical technique, an analysis of released ions, and a surface analysis by X-ray photoelectron spectroscopy (XPS). The effect of polishing the wire on the corrosion was also examined. The XPS analysis demonstrated the presence of a thick oxide film mainly composed of TiO2 with trace amounts of Ni hydroxide, which had formed on the wire surface during the heat treatment and subsequent pickling processes. This oxide layer contributed to the higher resistance of the as-received wire to both general and localized corrosion in 0.9% NaCl solution, compared with that of the polished plate and the polished wire. The thick oxide layer, however, was not stable and did not protect the orthodontic wire from corrosion in 0.1% lactic acid solution.

Corrosion↗