Search PubMed⌕ Search

Biomedical subjects

M I Miga

Publications and source records attributed to M I Miga.

14 recordsLinked to original sources

Three-dimensional subzone-based reconstruction algorithm for MR elastography.

Accurate characterization of harmonic tissue motion for realistic tissue geometries and property distributions requires knowledge of the full three-dimensional displacement field because of the asymmetric nature of both the boundaries of the tissue domain and the location of internal mechanical heterogeneities. The implications of this for magnetic resonance elastography (MRE) are twofold. First, for MRE methods which require the measurement of a harmonic displacement field within the tissue region of interest, the presence of 3D motion effects reduces or eliminates the possibility that simpler, lower-dimensional motion field images will capture the true dynamics of the entire stimulated tissue. Second, MRE techniques that exploit model-based elastic property reconstruction methods will not be able to accurately match the observed displacements unless they are capable of accounting for 3D motion effects. These two factors are of key importance for MRE techniques based on linear elasticity models to reconstruct mechanical tissue property distributions in biological samples. This article demonstrates that 3D motion effects are present even in regular, symmetric phantom geometries and presents the development of a 3D reconstruction algorithm capable of discerning elastic property distributions in the presence of such effects. The algorithm allows for the accurate determination of tissue mechanical properties at resolutions equal to that of the MR displacement image in complex, asymmetric biological tissue geometries. Simulation studies in a realistic 3D breast geometry indicate that the process can accurately detect 1-cm diameter hard inclusions with 2.5x elasticity contrast to the surrounding tissue.

Algorithms↗

Modeling of retraction and resection for intraoperative updating of images.

OBJECTIVE: Intraoperative tissue deformation that occurs during the course of neurosurgical procedures may compromise patient-to-image registration, which is essential for image guidance. A new approach to account for brain shift, using computational methods driven by sparsely available operating room (OR) data, has been augmented with techniques for modeling tissue retraction and resection. METHODS: Modeling strategies to arbitrarily place and move an intracranial retractor and to excise designated tissue volumes have been implemented within a computationally tractable framework. To illustrate these developments, a surgical case example, which uses OR data and the preoperative neuroanatomic image volume of the patient to generate a highly resolved, heterogeneous, finite-element model, is presented. Surgical procedures involving the retraction of tissue and the resection of a left frontoparietal tumor were simulated computationally, and the simulations were used to update the preoperative image volume to represent the dynamic OR environment. RESULTS: Retraction and resection techniques are demonstrated to accurately reflect intraoperative events, thus providing an approach for near-real-time image-updating in the OR. Information regarding subsurface deformation and, in particular, changing tumor margins is presented. Some of the current limitations of the model, with respect to specific tissue mechanical responses, are highlighted. CONCLUSION: The results presented demonstrate that complex surgical events such as tissue retraction and resection can be incorporated intraoperatively into the model-updating process for brain shift compensation in high-resolution preoperative images.

Brain Neoplasms↗

Microwave image reconstruction utilizing log-magnitude and unwrapped phase to improve high-contrast object recovery.

Reconstructing images of large high-contrast objects with microwave methods has proved difficult. Successful images have generally been obtained by using a priori information to constrain the image reconstruction to recover the correct electromagnetic property distribution. In these situations, the measured electric field phases as a function of receiver position around the periphery of the imaging field-of-view vary rapidly often undergoing changes of greater than pi radians especially when the object contrast and illumination frequency increase. In this paper, we introduce a modified form of a Maxwell equation model-based image reconstruction algorithm which directly incorporates log-magnitude and phase of the measured electric field data. By doing so, measured phase variation can be unwrapped and distributed over more than one Rieman sheet in the complex plane. Simulation studies and microwave imaging experiments demonstrate that significant image quality enhancements occur with this approach for large high-contrast objects. Simple strategies for visualizing and unwrapping phase values as a function of the transmitter and receiver positions within our microwave imaging array are described. Metrics of the degree of phase variation expressed in terms of the amount and extent of phase wrapping are defined and found to be figures-of-merit which estimate when it is critical to deploy the new image reconstruction approach. In these cases, the new algorithm recovers high-quality images without resorting to the use of a priori information on object contrast and/or size as previously required.

Algorithms↗

Magnetic resonance elastography using 3D gradient echo measurements of steady-state motion.

Magnetic resonance elastography (MRE) is an important new method used to measure the elasticity or stiffness of tissues in vivo. While there are many possible applications of MRE, breast cancer detection and classification is currently the most common. Several groups have been developing methods based on MR and ultrasound (US). MR or US is used to estimate the displacements produced by either quasi-static compression or dynamic vibration of the tissue. An important advantage of MRE is the possibility of measuring displacements accurately in all three directions. The central problem in most versions of MRE is recovering elasticity information from the measured displacements. In previous work, we have presented simulation results in two and three dimensions that were promising. In this article, accurate reconstructions of elasticity images from 3D, steady-state experimental data are reported. These results are significant because they demonstrate that the process is truly three-dimensional even for relatively simple geometries and phantoms. Further, they show that the integration of displacement data acquisition and elastic property reconstruction has been successfully achieved in the experimental setting. This process involves acquiring volumetric MR phase images with prescribed phase offsets between the induced mechanical motion and the motion-encoding gradients, converting this information into a corresponding 3D displacement field and estimating the concomitant 3D elastic property distribution through model-based image reconstruction. Fully 3D displacement fields and resulting elasticity images are presented for single and multiple inclusion gel phantoms.

Algorithms↗

In vivo quantification of a homogeneous brain deformation model for updating preoperative images during surgery.

Clinicians using image-guidance for neurosurgical procedures have recently recognized that intraoperative deformation from surgical loading can compromise the accuracy of patient registration in the operating room. While whole brain intraoperative imaging is conceptually appealing it presents significant practical limitations. Alternatively, a promising approach may be to combine incomplete intraoperatively acquired data with a computational model of brain deformation to update high resolution preoperative images during surgery. The success of such an approach is critically dependent on identifying a valid model of brain deformation physics. Towards this end, we evaluate a three-dimensional finite element consolidation theory model for predicting brain deformation in vivo through a series of controlled repeat-experiments. This database is used to construct an interstitial pressure boundary condition calibration curve which is prospectively tested in a fourth validation experiment. The computational model is found to recover 75%-85% of brain motion occurring under loads comparable to clinical conditions. Additionally, the updating of preoperative images using the model calculations is presented and demonstrates that model-updated image-guided neurosurgery may be a viable option for addressing registration errors related to intraoperative tissue motion.

Animals↗

In vivo modeling of interstitial pressure in the brain under surgical load using finite elements.

Current brain deformation models have predominantly reflected solid constitutive relationships generated from empirical ex vivo data and have largely overlooked interstitial hydrodynamic effects. In the context of a technique to update images intraoperatively for image-guided neuronavigation, we have developed and quantified the deformation characteristics of a three-dimensional porous media finite element model of brain deformation in vivo. Results have demonstrated at least 75-85 percent predictive capability, but have also indicated that interstitial hydrodynamics are important. In this paper we investigate interstitial pressure transient behavior in brain tissue when subjected to an acute surgical load consistent with neurosurgical events. Data are presented from three in vivo porcine experiments where subsurface tissue deformation and interhemispheric pressure gradients were measured under conditions of an applied mechanical deformation and then compared to calculations with our three-dimensional brain model. Results demonstrate that porous-media consolidation captures the hydraulic behavior of brain tissue subjected to comparable surgical loads and that the experimental protocol causes minimal trauma to porcine brain tissue. Working values for hydraulic conductivity of white and gray matter are also reported and an assessment of transient pressure gradient effects with respect to deformation is provided.

Animals↗

Elasticity reconstruction from experimental MR displacement data: initial experience with an overlapping subzone finite element inversion process.

The determination of the elastic property distribution in heterogeneous gel samples with a finite element based reconstruction scheme is considered. The algorithm operates on small overlapping subzones of the total field to allow for a high degree of spatial discretization while maintaining computational tractability. By including a Maxwellian-type viscoelastic property in the model physics and optimizing the spatial distribution of this property in the same manner as elasticity, a Young's modulus image is obtained which reasonably reflects the true distribution within the gel. However, the image lacks the clarity and accuracy expected based on simulation experience. Preliminary investigations suggest that transient effects in the data are the cause of a significant mismatch between the inversion model, which assumes steady-state conditions, and the actual displacements as measured by a phase contrast MR technique.

Algorithms↗

An overlapping subzone technique for MR-based elastic property reconstruction.

A finite element-based nonlinear inversion scheme for magnetic resonance (MR) elastography is detailed. The algorithm operates on small overlapping subzones of the total region of interest, processed in a hierarchical order as determined by progressive error minimization. This zoned approach allows for a high degree of spatial discretization, taking advantage of the data-rich environment afforded by the MR. The inversion technique is tested in simulation under high-noise conditions (15% random noise applied to the displacement data) with both complicated user-defined stiffness distributions and realistic tissue geometries obtained by thresholding MR image slices. In both cases the process has proved successful and has been capable of discerning small inclusions near 4 mm in diameter. Magn Reson Med 42:779-786, 1999.

Algorithms↗

A computational model for tracking subsurface tissue deformation during stereotactic neurosurgery.

Recent advances in the field of stereotactic neurosurgery have made it possible to coregister preoperative computed tomography (CT) and magnetic resonance (MR) images with instrument locations in the operating field. However, accounting for intraoperative movement of brain tissue remains a challenging problem. While intraoperative CT and MR scanners record concurrent tissue motion, there is motivation to develop methodologies which would be significantly lower in cost and more widely available. The approach we present is a computational model of brain tissue deformation that could be used in conjunction with a limited amount of concurrently obtained operative data to estimate subsurface tissue motion. Specifically, we report on the initial development of a finite element model of brain tissue adapted from consolidation theory. Validations of the computational mathematics in two and three dimensions are shown with errors of 1%-2% for the discretizations used. Experience with the computational strategy for estimating surgically induced brain tissue motion in vivo is also presented. While the predicted tissue displacements differ from measured values by about 15%, they suggest that exploiting a physics-based computational framework for updating preoperative imaging databases during the course of surgery has considerable merit. However, additional model and computational developments are needed before this approach can become a clinical reality.

Animals↗

Model-updated image guidance: initial clinical experiences with gravity-induced brain deformation.

Image-guided neurosurgery relies on accurate registration of the patient, the preoperative image series, and the surgical instruments in the same coordinate space. Recent clinical reports have documented the magnitude of gravity-induced brain deformation in the operating room and suggest these levels of tissue motion may compromise the integrity of such systems. We are investigating a model-based strategy which exploits the wealth of readily-available preoperative information in conjunction with intraoperatively acquired data to construct and drive a three dimensional (3-D) computational model which estimates volumetric displacements in order to update the neuronavigational image set. Using model calculations, the preoperative image database can be deformed to generate a more accurate representation of the surgical focus during an operation. In this paper, we present a preliminary study of four patients that experienced substantial brain deformation from gravity and correlate cortical shift measurements with model predictions. Additionally, we illustrate our image deforming algorithm and demonstrate that preoperative image resolution is maintained. Results over the four cases show that the brain shifted, on average, 5.7 mm in the direction of gravity and that model predictions could reduce this misregistration error to an average of 1.2 mm.

Adolescent↗

Updated neuroimaging using intraoperative brain modeling and sparse data.

A strategy to update preoperative imaging for image-guided surgery using readily available intraoperative information has been developed and implemented. A patient-specific three-dimensional finite element model of the brain is generated from preoperative MRI and used to simulate deformation resulting from multiple surgical processes. Intraoperatively obtained sparse imaging data, such as from digital cameras or ultrasonography, is then used to prescribe the displacement of selected points within the model. Interpolation to the resolution of preoperative imaging may then be performed based upon the model. The algorithms for generation of the finite element model and for its subsequent deformation have been successfully validated using a pig brain model, and preliminary clinical application in the operating room has demonstrated feasibility.

Algorithms↗

Coregistered ultrasound as a neurosurgical guide.

INTRODUCTION: The dynamic nature and three dimensionality of ultrasound data can be utilized to enhance the capabilities of image guidance systems. METHODS: Coregistration of ultrasound data was done using an electromagnetic digitizer, and subsequent ultrasound images were correlated with preoperative MRI studies. Thirty-two patients undergoing craniotomy were investigated in this manner. RESULTS: Phantom testing done with a rigid stylus and 3D ultrasound tracker demonstrated an accuracy of 1.36 +/- 1.67 mm in determining the location of a point. Thirty-two clinical cases were coregistered without difficulty. CONCLUSION: Coregistered ultrasound is a useful methodology that can aid in neuronavigation.

Brain↗

Intraoperatively updated neuroimaging using brain modeling and sparse data.

OBJECTIVE: Image-guided neurosurgery incorporating preoperatively obtained imaging information is subject to spatial error resulting from intraoperative brain displacement and deformation. A strategy to update preoperative imaging using readily available intraoperative information has been developed and implemented. METHODS: Preoperative magnetic resonance imaging is used to generate a patient-specific three-dimensional finite element model of the brain by which deformation resulting from multiple surgical processes may be simulated. Sparse imaging data obtained subsequently, such as from digital cameras or ultrasound, are then used to prescribe the displacement of selected points within the model. Based on the model, interpolation to the resolution of preoperative imaging may then be performed. RESULTS: The algorithms for generation of the finite element model and for its subsequent deformation were successfully validated using a pig brain model. In these experiments, the method recovered 84% of the intraoperative shift resulting from surgically induced tissue motion. Preliminary clinical application in the operating room has demonstrated feasibility. CONCLUSION: A strategy by which intraoperative brain deformation may be accounted for has been developed, validated in an animal model, and demonstrated clinically.

Adult↗

Intraoperative brain shift and deformation: a quantitative analysis of cortical displacement in 28 cases.

OBJECTIVE: A quantitative analysis of intraoperative cortical shift and deformation was performed to gain a better understanding of the nature and extent of this problem and the resultant loss of spatial accuracy in surgical procedures coregistered to preoperative imaging studies. METHODS: Three-dimensional feature tracking and two-dimensional image analysis of the cortical surface were used to quantify the observed motion. Data acquisition was facilitated by a ceiling-mounted robotic platform, which provided a number of precision tracking capabilities. The patient's head position and the size and orientation of the craniotomy were recorded at the start of surgery. Error analysis demonstrated that the surface displacement measuring methodology was accurate to 1 to 2 mm. Statistical tests were performed to examine correlations between the amount of displacement and the type of surgery, the nature of the cranial opening, the region of the brain involved, the duration of surgery, and the degree of invasiveness. RESULTS: The results showed that a displacement of an average of 1 cm occurred, with the dominant directional component being associated with gravity. The mean displacement was determined to be independent of the size and orientation of the cranial opening. CONCLUSION: These data suggest that loss of spatial registration with preoperative images is gravity-dominated and of sufficient extent that attention to errors resulting from misregistration during the course of surgery is warranted.

Adult↗