Search PubMed⌕ Search

Biomedical subjects

M Hoppe

Publications and source records attributed to M Hoppe.

At least 37 records · Page 2Linked to original sources

EEG predicts surgical outcome in lesional frontal lobe epilepsy.

BACKGROUND: Because of the relatively poor results of frontal lobe epilepsy (FLE) surgery, identification of prognostic factors for surgical outcome is of great importance. METHODS: To identify predictive factors for FLE surgery, we analyzed the data of 61 patients (mean age at surgery 19.2) who had undergone presurgical evaluation and resective surgery in the frontal lobe. Postoperative follow-up ranged from 0.5 to 5 years (mean 1.78). Fifty-nine patients had MRI-detectable lesions. Histopathologic examination showed dysplasia (57.4%), tumor (16.4%), or other lesions (26.2%). Thirty postoperatively seizure-free patients were compared with 31 non-seizure-free patients with respect to clinical history, seizure semiology, EEG and neuroimaging data, resected area, and postoperative data including histopathology. RESULTS: Three preoperative and two postoperative variables were related to poor outcome: generalized epileptiform discharges, generalized slowing, use of intracranial electrodes, incomplete resection detected by MRI, and postoperative epileptiform discharges. The only preoperative factor associated with seizure-free outcome was the absence of generalized EEG signs. Multivariate analysis showed that only the absence of generalized EEG signs predicts the outcome independently. Moreover, the occurrence of a somatosensory aura, secondarily generalized seizures, and negative MRI was identified as additional independent risk factors for poor surgical results. CONCLUSIONS: The absence of generalized EEG signs is the most predictive variable for a seizure-free outcome in FLE surgery. Furthermore, nonlesional MRI, somatosensory aura, and secondarily generalized seizures are risk factors for poor surgical results.

Adolescent↗

Tracheal rupture caused by blunt chest trauma: radiological and clinical features.

The aim of this study was to assess radiomorphologic and clinical features of tracheal rupture due to blunt chest trauma. From 1992 until 1998 the radiomorphologic and clinical key findings of all consecutive tracheal ruptures were retrospectively analyzed. The study included ten patients (7 men and 3 women; mean age 35 years); all had pneumothoraces which were persistent despite suction drainage. Seven patients developed a pneumomediastinum as well as a subcutaneous emphysema on conventional chest X-rays. In five patients, one major hint leading to the diagnosis was a cervical emphysema, discovered on the lateral cervical spine view. Contrast-media-enhanced thoracic CT was obtained in all ten cases and showed additional injuries (atelectasis n = 5; lung contusion n = 4; lung laceration n = 2; hematothorax n = 2 and hematomediastinum n = 4). The definite diagnosis of tracheal rupture was made by bronchoscopy, which was obtained in all patients. Tracheal rupture due to blunt chest trauma occurs rarely. Key findings were all provided by conventional chest X-ray. Tracheal rupture is suspected in front of a pneumothorax, a pneumomediastinum, or a subcutaneous emphysema on lateral cervical spine and chest films. Routine thoracic CT could also demonstrate these findings but could not confirm the definite diagnosis of an tracheal rupture except in one case; in the other 9 cases this was done by bronchoscopy. Thus, bronchoscopy should be mandatory in all suspicious cases of tracheal rupture and remains the gold standard.

Adult↗

Interictal EEG and ictal scalp EEG propagation are highly predictive of surgical outcome in mesial temporal lobe epilepsy.

PURPOSE: Surgical outcome in patients with mesial temporal lobe sclerosis (MTS) is worse than that in patients with temporal lobe activity (TLE) with tumors. Previous studies of the ictal EEG focused on ictal EEG onset in scalp EEG or ictal EEG propagation in invasive recordings. Ictal EEG propagation with scalp electrodes has not been reported. METHODS: Ictal scalp EEG propagation patterns were studied in 347 seizures of 58 patients with MTS or nonlesional TLE. Interictal epileptiform discharges (IEDs) and the presence of unilateral mesial temporal lobe atrophy in magnetic resonance imaging (MRI) also were studied in these 58 patients. Forty-nine patients were operated on (minimal follow-up of 1 year). RESULTS: Postoperatively, seizure-free outcome was seen in (a) 82.8% of patients with regionalized EEG seizure without contralateral propagation, but in only 45.5% of patients with contralateral propagation (p = 0.007); (b) 84.6% of patients with 100% IED lateralized to one temporal lobe, but in only 52.2% with <100% unitemporal IED (p = 0.015); (c) 88.9% with 100% unitemporal IED and regionalized ictal EEG combined, 73.7% with one of both variables, and only 33.3% with <100% ipsitemporal IED combined with contralateral ictal EEG propagation (p = 0.007). CONCLUSIONS: Switch of lateralization or bitemporal asynchrony in the ictal scalp EEG and bitemporal IED are most probably an index of bitemporal epileptogenicity in MTS and are associated with a worse outcome.

Adolescent↗

[Epiphyseal injuries of the distal tibia. Does MRI provide useful additional information?].

Plain film radiography often underestimates the extent of injury in children with epiphyseal fracture. Especially Salter-Harris V fractures (crush fracture of the epiphyseal plate) are often primarily not detected. MRI of the ankle was performed in 10 children aged 9-17 (mean 14) years with suspected epiphyseal injury using 1.0-T Magnetom Expert. The fractures were classified according to the Salter-Harris-Rang-Odgen classification and compared with the results of plain radiography. In one case MRI could exclude epiphyseal injury; in four cases the MRI findings changed the therapeutic management. The visualisation of the fracture in three orthogonal planes and the possibility of detection of cartilage and ligamentous injury in MR imaging makes this method superior to conventional radiography and CT. With respect to radiation exposure MRI instead of CT should be used for the diagnosis of epiphyseal injuries in children.

Adolescent↗

Effects of nitinol Strecker stent placement on vascular response in normal and stenotic porcine iliac arteries.

PURPOSE: This experimental study was conducted to evaluate neointimal thickness, lumen diameters, and histologic changes in normal and stenotic porcine iliac arteries following placement of self-expanding nitinol Strecker stents. MATERIALS AND METHODS: Neointimal trauma causing slight vascular stenosis was induced unilaterally within external iliac arteries of 12 swines by means of endothelial abrasion and high cholesterol diet. Nitinol Strecker stents were placed within the stenotic and the normal contralateral vascular segments. For histopathologic evaluation, the pigs were killed 12 or 24 weeks after stent placement and luminal diamters were evaluated angiographically. RESULTS: Excluding one occlusion, 15% narrowing of the lumen diameter was induced unilaterally (P = .002). Initial luminal gain after stent placement was greater for stenotic than for normal arteries. The amount of neointima thickness was not different between stenotic and normal vessels (P > .05). Comparing vascular diameters before stent placement and at follow-up, luminal loss due to neointima proliferation was 22% within normal arteries (P = .0002), while a luminal gain by 15% was found within the stenotic arteries (P = .008). Maturation of neointima and endothelial coverage were complete after 24 weeks. CONCLUSIONS: Even though nitinol Strecker stents induce excessive neointimal proliferation, stenotic arteries seem to profit from great early luminal gain resulting in 15% of vascular expansion at follow-up while slight stenosis is induced within normal iliac arteries.

Alloys↗

Metastatic RCC arising in a transplant kidney.

We report a case of metastatic renal cell carcinoma arising in a cadaver transplant kidney 6 years after transplantation. Due to molecular analysis of the tumor tissue we could prove that the carcinoma originated from the male donor. After tumor resection and interruption of immunotherapy, the concomitant bone and lymph node metastases resolved with alpha-interferon and interleukin-2-based immunotherapy.

Antineoplastic Agents↗

[Postoperative imaging of synthetic coronary artery bypass graft patency by means of CT angiography].

PURPOSE: CT angiography was performed in 12 patients with insufficient autologous graft situations to evaluate postoperative patency and situation of the proximal, distal and coronary artery anastomoses of synthetic Perma-Flow coronary artery bypass grafts. METHODS: Bypass grafts were evaluated postoperatively with spiral CT of the mediastinum. At a flow rate of 3 ml/s, 120 ml of contrast material were applied over a cubital vein. Slice thickness was 3 mm, maximum pitch factor 2 and image reconstruction was performed at 2 mm increment. Shaded surface displays were analysed together with axial scans for bypass evaluation. RESULTS: 8 out of 12 synthetic bypasses proved to be patent. One bypass was completely occluded and in three patients the distal portions of the grafts were occluded. Coronary angiography performed in one case confirmed complete bypass occlusion. Due to the occlusions, 8 distal and 12 proximal anastomoses were visible. Only 8 out of 19 side-to-side coronary artery anastomoses could be sufficiently well imaged with this technique. CONCLUSIONS: CT angiography is suitable for postoperative screening of synthetic coronary bypasses to determine the patency and anastomotic situations. Coronary artery anastomoses however are not sufficiently imaged and coronary angiography continues to be required.

Adult↗

[Pitfalls when using a contrast media injector in MRI].

PURPOSE: Using a power injector to applicate Gd-DTPA we found a contrast enhancement of the pyelo-caliceal system even in the native studies, and hence we analysed pitfalls when using power injectors in MRI. MATERIAL AND METHODS: We used a power injector Spectris (MedRad, Maastricht, Netherlands). In vitro artifacts were achieved by the mixture of contrast media and saline solution. We substituted contrast media by red water, NaCl by clear water. RESULTS: Using power injectors in MRI, some pitfalls must be avoided, which can render investigations useless, especially dynamic contrast-enhanced investigations. CONCLUSION: In our study we showed an easy way to overcome some pitfalls and use a power injector in MRI in a diagnostically helpful way. The simple use of valves inhibits the mixture of contrast media and saline solution.

Contrast Media↗

[Mortality and morbidity conference in radiology].

PURPOSE: To establish a morbidity and mortality conference in a radiology department as an instrument of quality assurance. METHODS: Since April 1995 a monthly conference is held in the radiology department. Complications of invasive diagnostic procedures (angiography and biopsy) and minimal invasive interventions are presented. Cases of morbidity (major complications) and mortality (deceased patients, who were examined or treated in the radiology department before) are discussed. The identification of cases was possible due to a data base that included all such procedures prospectively. RESULTS: Twenty cases of major complications were identified and discussed during 18 morbidity and mortality conferences in 1996 and 1997. Out of the 9 patients who died in our hospital and previously had an interventional procedure in the radiology department, one case was identified as being procedure-related. An analysis of this case was performed. CONCLUSION: With a formalised structure of case detection, the morbidity and mortality conference becomes a tool of a complete analysis of complications and a meaningful instrument for the solution of problems concerning procedure-related complications.

Aged↗

Correlation of flow velocity measurements by magnetic resonance phase contrast imaging and intravascular Doppler ultrasound.

RATIONALE AND OBJECTIVES: The authors compare the magnetic resonance (MR) phase contrast flow velocity measurements in varying concentric stenoses with invasive measurements obtained with a Doppler guidewire. METHODS: Flow velocity measurements were obtained using a calibrated 0.018 inch 12 MHz Doppler guidewire and a 1.0 T MR imaging system in a pulsatile hydraulic model with variable arterial stenoses. Velocity measurements were performed proximal, intrastenotic, and distal to the stenoses. The cross-sectional area of stenosis was calculated from the data of both methods. For MR imaging measurements, fast low-angle shot two-dimensional phase contrast sequences with different velocity encodings were used. RESULTS: Phase contrast flow measurements correlated well (r = 0.95, Pearson) with Doppler guidewire-based flow velocity data. Generally, flow velocities obtained with MR imaging were lower when compared with the Doppler-based data (P < or = 0.001, Wilcoxon matched pairs test). However, the ratios and the calculated cross-sectional area of stenoses showed a high correlation (r = 0.96) with the predefined area of stenoses. CONCLUSIONS: The assessment of flow alterations in vitro due to variable stenoses using MR phase contrast flow measurements is very well correlated with the Doppler guidewire. Consequently, these results required in vivo measurements of atherosclerotic lesions to evaluate the clinical impact.

Blood Flow Velocity↗

[Must the patient fast before intravascular injection of a non-ionic contrast medium? Results of a controlled study].

PURPOSE: Prospective evaluation of food and fluid restriction before the intravascular injection of a non-ionic contrast medium. MATERIAL AND METHODS: 1000 patients (657 men, 343 women; average age 59 +/- 1/4 5 years) undergoing intravascular contrast injections (CT, phlebography, angiography, urography) were randomly allocated to two groups. Group A had no fluid or solids for at least four hours before the injection (499 cases); group B were allowed unlimited food and fluid (501 cases). Both groups were comparable in all other respects and all were given the non-ionic contrast medium iopamidol (300 mg l/ml). RESULTS: The incidence of acute complications was 3.5%. There was, however, no statistically significant difference between the two groups (p = 0.29). Late adverse reactions were seen in 3.9% patients. There was again no difference between the two groups (p = 0.33). No serious or life threatening complications occurred. CONCLUSION: Restriction of food and fluid before intravascular injection of contrast medium does not reduce the number of adverse side effects. For reasons of patient comfort and compliance, and to achieve adequate hydration, the patient should not fast before injection of contrast.

Adult↗

[In vitro evaluation of the intravasal Doppler guide wire: determination of hemodynamic effects of stenoses in a flow model].

PURPOSE: In a pulsatile hydraulic model, haemodynamic changes caused by stenoses were assessed using an intravascular Doppler guide wire. MATERIAL AND METHODS: In defined stenoses (25, 50, 75 and 87.5% diameter ratio), and with and without collateral flow, a 0.018 inch (0.46 mm) 12 MHz Doppler guide wire was assessed. Flow velocity measurements were taken 20 mm proximal, in, and 20 mm distal to the stenoses. Average peak velocity (APV) and ratios of pre-/poststenotic velocities and pre-/intrastenotic velocities of APV were compared with the grade of stenosis. The degree of the stenosis calculated by the ratio of the cross-sectional area, using the pre- and intrastenotic APV, was correlated with the actual stenosis. RESULTS: The intrastenotic APV increased significantly (APV proximal to the stenosis 15.15 +/- 4.5 cm/s, intrastenotic APV 134.8 +/- 130.9, p < 0.01, Wilcoxon-Mann-Whitney test). The difference between APV pre- and poststenotic was not significant (p > 0.5). Concerning the grade of stenosis the ratio APV pre-/intrastenotic and the consecutively calculated cross-sectional area stenoses was the best predictor (correlation with the known cross-sectional area stenosis r = 0.94 Pearson). CONCLUSION: Using the Doppler guide wire, APV measurements pre- and intrastenotic enable a reliable quantification of the grade of stenosis. The stenosis calculated via the cross-sectional area correlates significantly with the actual stenosis.

Arterial Occlusive Diseases↗

[CT quantification of pleuropulmonary lesions in severe thoracic trauma].

PURPOSE: Computed quantification of the extent of pleuropulmonary trauma by CT and comparison with conventional chest x-ray--Impact on therapy and correlation with mechanical ventilation support and clinical outcome. METHOD: In a prospective trial, 50 patients with clinically suspicious blunt chest trauma were evaluated using CT and conventional chest x-ray. The computed quantification of ventilated lung provided by CT volumetry was correlated with the consecutive artificial respiration parameters and the clinical outcome. RESULTS: We found a high correlation between CT volumetry and artificial ventilation concerning maximal pressures and inspiratory oxygen concentration (FiO2, Goris-Score) (r = 0.89, Pearson). The graduation of thoracic trauma correlated highly with the duration of mechanical ventilation (r = 0.98, Pearson). Especially with regard to atelectases and lung contusions CT is superior compared to conventional chest x-ray; only 32% and 43%, respectively, were identified by conventional chest x-ray. CONCLUSION: CT allows rapid classification and quantification of pulmonary lesions after thoracic trauma and provides higher sensitivity and reliability. Because of the great correlation with the extent of artificial respiration in respect of duration and pressure, prognosis of the individual patient, as well as a differential therapy, appear possible.

Adolescent↗

Localization of epileptic auras induced on stimulation by subdural electrodes.

PURPOSE: This study evaluates the localization of stimulation-induced auras (SIA) and tries to determine whether the SIA can help to define the boundaries of resection in epilepsy surgery. METHODS: Using subdural grid electrodes, 31 patients with drug resistant focal epilepsy were examined in a retrospective and prospective study lasting 2 years. RESULTS: On stimulation by subdural electrodes, we elicited habitual auras in 16 patients (52%). The zone of SIA overlapped the epileptogenic lesion in 12 patients (75%), the EEG seizure onset zone in 12 patients (75%), and the irritative zone of interictal spikes in eight patients (50%). Postoperative results showed a significant correlation with the complete removal of the epileptogenic lesion (p < 0.001). Because the number of patients in the study was small, we could not find a significant correlation with the complete removal of the SIA zone, EEG seizure onset zone, and irritative zone. CONCLUSIONS: Our study confirms previous analyses which indicate that complete resection of the epileptogenic lesion is essential to achieve a good outcome. Frequent overlap of the SIA zone with the epileptogenic lesion and the EEG seizure onset zone indicates proximity of the SIA with the epileptogenic zone. Nevertheless, this study does not support the concept that the SIA zone and the EEG seizure onset zone have additional value in defining the boundaries of resection in epilepsy surgery. Three case presentations suggest that SIA result from facilitated pathways between the stimulated cortex, the epileptogenic zone around the lesion, and the symptomatogenic zone. Functional reorganization in the vicinity of the cortical lesion cannot be ruled out but was not seen in our patients. Thus, SIA often do not reflect the normal function of the stimulated underlying cortex.

Adolescent↗