Search PubMed⌕ Search

Biomedical subjects

M Harvey

Publications and source records attributed to M Harvey.

At least 73 records · Page 4Linked to original sources

A "pre-satiety sequence" in rats drinking sucrose solutions.

Food-deprived rats were given intermittent access or, in a replication, continuous access to a 20% sucrose solution. Both drinking and nondrinking behaviors were recorded. During the ensuing drinking bout, latency of lapping after snout apposition, and duration of lapping bouts, did not change. Approaches to the sipper tube usually eventuated in lapping, though aborted approaches increased in frequency late in the session. Drinking was interrupted by nondrinking behaviors which appeared in a characteristic rostro-caudal sequence: partial head withdrawal from the drinking aperture, then full head withdrawal, then movements of the front paws, then movement of the hind paws with full-body locomotion. All these behavioral changes occurred before there was any appreciable reduction in rate of lapping.

Animals↗

Visual size processing in spatial neglect.

Evidence from the use of the landmark task and from two size-matching tasks shows that many patients with left-sided neglect systematically under-perceive visual extent in leftward parts of space. This perceptual distortion of size serves to explain the occurrence of rightward line-bisection errors in most neglect patients. One possibility is that attentional biases of a chronic nature might underlie these perceptual changes seen in neglect patients. But contrary to this idea, we have found that attentional cueing in the landmark task causes changes in neglect patients exactly opposite to those seen in healthy subjects. The distortions of size perception seen in neglect could instead be caused by a high-level alteration of visual processing rather than by an attentional bias. In order to explore which visual stream of cortical processing might be compromised in such a disorder, we have begun to examine neglect patients on visuomotor as well as perceptual tasks. We have found clear evidence in one patient for intact grip scaling for object size in the neglected half of space, despite gross perceptual underestimations of the same objects. This result suggests that neglect can occur without major disruption of the dorsal stream, and may result instead from damage to a cortical system whose predominant visual input comes from the ventral stream.

Attention↗

Influence of right ventricular site of stimulation and infarct location on the inducibility of ventricular tachycardia in patients with coronary artery disease.

No prior studies have evaluated the relationship between the site of right ventricular stimulation, the site of prior infarction, and the inducibility of ventricular tachycardia (VT). This study was performed to determine if the location of pathologic Q waves influences the inducibility of VT at various right ventricular sites in patients with coronary artery disease (CAD) and a history of myocardial infarction (MI). In 30 patients with a history of sustained, monomorphic VT, CAD, prior MI, and pathologic Q waves, programmed ventricular stimulation was performed at the right ventricular apex, septum, and outflow tract, in random order. There was electrocardiographic evidence of an MI that was inferior in 11 patients, anterior in 10 patients, and both inferior and anterior in 9 patients. Sustained, monomorphic VT was induced in 27 of 30 patients (90%). There were no significant differences among the three sites in the rate of inducibility of VT. The rate of inducible VT at each of the three right ventricular sites was not affected by the location of prior infarction. In conclusion, among patients with sustained, monomorphic VT, CAD, and a history of MI, the incidence of inducible sustained, monomorphic VT is not influenced by the location of prior infarction, regardless of whether programmed ventricular stimulation is performed at the right ventricular apex, septum, or outflow tract.

Cardiac Pacing, Artificial↗

A comparative study on the efficacy of CD8-positive cells in enhancing allogeneic bone marrow engraftment: cell sorting vs microbead selection.

We have used a superparamagnetic microbead selection system to positively select a murine bone marrow CD8+ cell population. The functional ability of these cells to enhance allogeneic bone marrow engraftment was compared with that of fluorescence activated cell sorter purified CD8+ cells. The CD8+ cell population prepared by the microbead selection procedure was as effective as cell sorter purified CD8+ cells in enhancing T cell-depleted allogeneic bone marrow engraftment in lethally irradiated mice. Phenotypic characterization of these cells shows that most of these CD8+ cells express CD3 and the T cell antigen receptor complex.

Animals↗

Characterization of the ABO blood group genes in macaques: evidence for convergent evolution.

The ABO blood group system is known to act as a major transplantation barrier in primates. Different primate species share the presence of A and B antigens. The polymorphism of the macaque ABO blood group genes was analyzed by cloning and sequencing the exon 7 region. In the case of the rhesus macaque (Macaca mulatta) and cynomolgus monkey (Macaca fascicularis) we were able to identify ABO blood group gene segments which cluster into two lineages, namely: *A/*O1 and *B. In addition allelic variation was observed. The 2 amino acid replacements at positions 266 and 268, which are thought to be crucial for A or B transferase activity, could be confirmed for both macaque species. Comparison of primate sequences shows that A and B reactivity was generated independently from each other in the hominoids and Old World monkey lineages. Hence, the primate A and B blood group genes are subject to convergent evolution.

ABO Blood-Group System↗

Making changes to improve the intensive care unit experience for patients and their families.

With the technology explosion and scientific advances in the field of critical care in the past three decades came an era in which ICUs were referred to as an arena for punitive survivalists. Although clinicians have developed an increased ability to improve the quality and quantity of life for patients in the long term post discharge, patients and their families often suffered more than is necessary in the short term, during the critical care phase of the illness. It is well documented that physiologic and psychologic stress impacts negatively on both short-term and long-term patient outcomes. In the last 10 yrs, the attention of individual caregivers, units, organizations, and researchers has turned to improving the ICU experience for patients and families. This article reviews the relevant literature and also reports the experience of those who have created and applied unique strategies that address the patient and family needs, thus promoting their comfort and relieving their distress. Although more outcome studies are needed in this area of care, applying some of the lessons already learned can significantly improve the ICU experience for most patients and families.

Communication↗

Grip force scaling after hemispatial neglect.

Spatial neglect has been explained as an impairment in the representation of extrapersonal space. One account suggests that representations of extrapersonal space are spatially compressed following neglect. In support of this view it has been demonstrated that neglect patients systematically underestimate the size of stimuli presented in their left hemifield. In the current study we investigated this phenomena by obtaining an indirect measure of perceived object size - the scaling of grip force during prehension. We demonstrate for the first time that neglect patients show increased levels of grip force for objects presented in their left hemifield. This finding is discussed with reference to a proposed distinction between visual processing used for object recognition, and visual processing used to guide action.

Aged↗

Isolation, cloning and characterisation of the abiI gene from Lactococcus lactis subsp. lactis M138 encoding abortive phage infection.

Plasmid pND852 (56 kb) encodes nisin resistance and was isolated from Lactococcus lactis ssp lactis (L. lactis) M138 by conjugation to L. lactis LM0230. It conferred strong resistance to the isometric-headed phage phi 712 and partial resistance to the prolate-headed phage phi c2. A 2.6 kb HpaII fragment encoding phage resistance was cloned into the streptococcal/Bacillus hybrid vector pGB301 to generate pND817. The mechanism of phage resistance encoded by pND817 involved abortive infection and this was illustrated by a reduction in burst size from 166 to 6 at 30 degrees C and from 160 to 90 at 37 degrees C. Partial resistance was therefore retained at 37 degrees C. DNA sequencing revealed that the abortive infection was encoded by a single open reading frame (ORF), designated abiI, encoding a 332 amino acid protein. Neither abiI nor the predicted product showed significant homology to any existing sequence in the GenBank database. Frame shift mutation at the unique EcoRI site within the ORF resulted in loss of the Abi+ phenotype, confirming that the ORF is responsible for the encoded phage resistance.

Amino Acid Sequence↗

Comparison of effective and ineffective target sites that demonstrate concealed entrainment in patients with coronary artery disease undergoing radiofrequency ablation of ventricular tachycardia.

BACKGROUND: Concealed entrainment has been useful in guiding catheter ablation of monomorphic ventricular tachycardia in patients with coronary artery disease. However, not all sites with concealed entrainment result in successful ablation of the targeted ventricular tachycardia. The purpose of this prospective study was to identify factors at sites that demonstrate concealed entrainment that differentiate effective from ineffective target sites. METHODS AND RESULTS: In 14 consecutive patients with hemodynamically stable monomorphic ventricular tachycardia and coronary artery disease, radiofrequency ablation of 26 ventricular tachycardias was performed. Ablation was attempted at 46 sites that demonstrated concealed entrainment. Twenty-five of the targeted ventricular tachycardias (96%) were successfully ablated. The positive predictive value of concealed entrainment for successful ablation was 54%; it increased to 72% in the presence of a stimulus-QRS interval/ventricular tachycardia cycle length ratio of < or = 70%, to 82% in the presence of a match of the stimulus-QRS and electrogram-QRS interval, and to 89% in the presence of isolated mid diastolic potentials that could not be dissociated from ventricular tachycardia during entrainment. CONCLUSIONS: The positive predictive value of concealed entrainment for identification of successful ablation sites in patients with sustained ventricular tachycardia and coronary artery disease can be significantly enhanced by the presence of associated mapping criteria, particularly an isolated mid diastolic potential that cannot be dissociated from the tachycardia.

Adult↗

Long-term follow-up after radiofrequency modification of the atrioventricular node in patients with atrial fibrillation.

OBJECTIVES: The purpose of this study was to describe the long-term follow-up results in 62 patients with atrial fibrillation and an uncontrolled ventricular rate, who underwent radiofrequency modification of the atrioventricular (AV) node. BACKGROUND: Previous studies in small numbers of patients have suggested that radiofrequency modification may be effective in controlling the ventricular rate in patients with atrial fibrillation, but long-term follow-up data have been lacking. METHODS: The subjects of this study were 62 consecutive patients (mean age +/- SD 65 +/- 14 years; 43 with structural heart disease) who underwent an attempt at radiofrequency modification of the AV node because of symptomatic, drug-refractory atrial fibrillation with an uncontrolled ventricular rate. The atrial fibrillation was chronic in 46 patients and paroxysmal in 16. Radiofrequency energy was applied to the posteroseptal or mid-septal right atrium to lower the ventricular rate in atrial fibrillation to 120 to 130 beats/min during an infusion of 4 micrograms/min of isoproterenol. RESULTS: Short-term control of the ventricular rate was successfully achieved without the induction of pathologic AV block in 50 (81%) of 62 patients. Inadvertent high degree AV block occurred in 10 (16%) of 62 patients, with the AV block occurring at the time of the procedure in 6 patients and 36 to 72 h after the procedure in 4. During 19 +/- 8 months of follow-up (range 4 to 33), 5 (10%) of 50 patients had a symptomatic recurrence of an uncontrolled rate during atrial fibrillation. Overall, adequate rate control at rest and during exertion, without pathologic AV block, was achieved long term in 45 (73%) of 62 patients. Among 37 patients with a successful outcome, left ventricular ejection fraction increased from (mean +/- SD) 0.44 +/- 0.14 to 0.51 +/- 0.10 one year later (p < 0.001). Complications other than AV block included polymorphic ventricular tachycardia 10 to 24 h after the procedure in two patients who had a predisposing factor for ventricular tachycardia and sudden death 1 to 5 months after the procedure in two patients with idiopathic dilated cardiomyopathy, one of whom had a pacemaker for AV block. CONCLUSIONS: In approximately 70% of properly selected patients with atrial fibrillation and an uncontrolled ventricular rate, radiofrequency modification of the AV node results in excellent long-term control of the ventricular rate at rest and during exertion.

Aged↗

Effect of an irregular ventricular rhythm on cardiac output.

Impairment of cardiac function in atrial fibrillation has been attributed to loss of atrial contraction and to a rapid ventricular rate. The results of this study suggest that irregularity of the ventricular rhythm, independent of the ventricular rate, may also contribute to impairment of cardiac function during atrial fibrillation.

Atrial Fibrillation↗

Effect of coupling interval and pacing cycle length on morphology of paced ventricular complexes. Implications for pace mapping.

BACKGROUND: Ventricular pace mapping is performed by comparing the QRS morphology of ventricular paced complexes to that of a template arrhythmia, either a premature ventricular depolarization or a QRS complex during ventricular tachycardia. The objective of this study was to evaluate the effect of coupling interval and pacing cycle length on QRS morphology. METHODS AND RESULTS: The study population consisted of 20 patients (mean age, 38 +/- 16 years) undergoing a clinically indicated electrophysiology procedure. In the first 10 patients, the effect of coupling interval on the morphology of single paced ventricular complexes was evaluated visually and by signal processing techniques. Visually apparent differences in QRS morphology occurred in a mean of 4/12 electrocardiographic leads with a change in coupling interval of > or = 100 ms. In the next 10 patients, the QRS complex morphology during ventricular overdrive pacing at cycle lengths of 600 and 300 ms was found to differ significantly in a mean of 4/12 leads. The QRS morphology during overdrive pacing differed significantly from that of a single paced complex whenever the pacing cycle length differed from the coupling interval of the single paced complex by > 80 ms. CONCLUSIONS: The morphology of single paced QRS complexes may vary, depending on coupling interval, and the QRS morphology during overdrive pacing is affected by the pacing cycle length. During ventricular pace mapping, the coupling interval or cycle length of the template arrhythmia should be matched during pacing. If not, rate-dependent changes in QRS morphology that are independent of the pacing site may confound the results of pace mapping.

Adult↗

Effect of atrial fibrillation on atrial refractoriness in humans.

BACKGROUND: The acute effect of atrial fibrillation (AF) on the atrial effective refractory period (ERP) in humans is unknown. METHODS AND RESULTS: In 20 patients without structural heart disease, the atrial ERP was measured before and after pacing-induced AF at drive cycle lengths of 350 and 500 ms. Immediately after spontaneous AF conversion, the post-AF ERP was measured. The pre-AF ERPs at 350 and 500 ms were 206 +/- 23 and 216 +/- 17 ms, respectively. The time to spontaneous conversion of AF was 7.3 +/- 1.9 minutes. The first post-AF ERPs at drive cycle lengths of 350 and 500 ms were 175 +/- 30 ms (P < .0001 versus pre-AF) and 191 +/- 30 ms (P < .0001 versus pre-AF), respectively. The post-AF ERP returned to the pre-AF ERP value after a mean of 8.4 +/- 0.3 minutes. In 15 patients, during the determination of the post-AF ERP, secondary episodes of AF lasting 1 +/- 1.5 minutes were reinduced 6 +/- 3 times per patient. There was a significant inverse logarithmic relationship between the time to reinduction of AF and the duration of secondary episodes of AF (P < .0001, r = 5). CONCLUSIONS: In humans, several minutes of induced AF is sufficient to shorten the ERP for up to approximately 8 minutes. The temporal recovery of the ERP is reflected in progressively shorter episodes of reinduced AF. These data imply that AF transiently shortens the atrial wavelength and suggest a mechanism by which AF may perpetuate itself.

Adult↗

Spatial resolution of atrial pace mapping as determined by unipolar atrial pacing at adjacent sites.

BACKGROUND: The purpose of this study was to examine the spatial resolution of unipolar atrial pace mapping by pacing at adjacent sites within the coronary sinus and the right atrium. METHODS AND RESULTS: Unipolar pacing from each pole of a quadripolar catheter was performed in the coronary sinus (n = 29) and in the right atrium (n = 10). Pacing from the distal electrode was used to simulate the site of origin of an atrial tachycardia. These P waves were compared with the P waves generated by unipolar pacing from each of the three proximal electrodes. The P waves were analyzed for changes in amplitude, duration, and configuration. Pacing within the coronary sinus resulted in significant changes in amplitude and duration at distances of 17 and 21 mm from the distal pole, respectively. Similarly, pacing in the right atrium resulted in significant changes in amplitude and duration at distances of 17 and 32 mm from the distal pole, respectively. No significant changes in configuration were noted in the coronary sinus in any lead at packing sites < or = 32 mm from the distal pole. Configurational changes were noted in the right atrium at pacing sites 17 mm from the distal pole. CONCLUSIONS: The spatial resolution of unipolar atrial pace mapping is approximately 17 mm. These findings indicate that mapping techniques that depend on the accurate discrimination of P-wave morphology, such as pace mapping or concealed entertainment, are likely to be imprecise when used in the atria.

Adult↗

Response of type I atrial fibrillation to atrial pacing in humans.

BACKGROUND: High-density mapping studies of atrial fibrillation (AF) have suggested the presence of an excitable gap. The purpose of this study was to assess the local and left atrial response to pacing at the high right atrium during type I AF in humans. METHODS AND RESULTS: Pacing was performed at the high right atrium during type I AF in 24 patients in the electrophysiology laboratory. The response to pacing was assessed at cycle lengths 10, 20, 30, 40, and 50 ms less than the mean baseline atrial cycle length. Digitized tracings of the baseline tachycardia and the response to pacing were recorded from the high right atrium and from the distal coronary sinus. Computer analysis of these signals was used to calculate a left atrial electrogram density before, during, and after pacing. Two hundred eight-eight segments of AF with a duration of 3.9 +/- 0.5 seconds (mean +/- SD) were analyzed. Local capture of the right atrium during AF was demonstrated for at least one pacing cycle length in each patient. The left atrial electrogram density was significantly greater than baseline at each pacing cycle length that resulted in local capture, except when pacing at 50 ms less than the mean AF cycle length. There was no significant change in the baseline left atrial electrogram density compared with baseline when pacing did not result in local capture of AF. CONCLUSIONS: Local right atrial capture is often possible by pacing during type I AF and consistently influences the left atrial electrograms recorded in the coronary sinus. These results confirm the presence of excitable tissue in the right and left atria in type I AF.

Adult↗

Reasons for prolonged or failed attempts at radiofrequency catheter ablation of accessory pathways.

OBJECTIVES: The purpose of this study was to categorize the reasons for a prolonged or failed procedure in a series of patients undergoing catheter ablation of an accessory pathway. BACKGROUND: Radiofrequency ablation of accessory pathways at times requires a lengthy procedure or a second ablation session, or both, and not prior studies have systematically investigated the reasons for this. METHODS: In a consecutive series of 619 patients undergoing catheter ablation of an accessory pathway, the mean ablation time +/- SD was 68 +/- 64 min. The subjects of this study were 14 patients who had an ablation time >2 SD greater than the mean (>196 min) and 51 patients who required a second ablation session for a successful outcome. The accessory pathway in the 65 patients in this study was located in the right free wall in 19 patients (29%), septum in 14 (22%) and left free wall in 32 (49%). RESULTS: The primary reasons for a lengthy or failed ablation attempt were 1) inability to position the ablation catheter at the effective target site (16 patients, 25%); 2) instability of the ablation catheter or inadequate tissue contact at the target site, or both (15 patients, 23%); 3) mapping error due to an oblique course of the accessory pathway (7 patients, 11%); 4) failure to recognize a posteroseptal accessory pathway as being left-sided instead of right-sided (4 patients, 6%); 5) other errors in accessory pathway localization (6 patients, 9%); 6) epicardial location of the accessory pathway (5 patients, 8%); 7) recurrent atrial fibrillation (2 patients, 3%); 8) occurrence of a complication (2 patients, 3%); 9) unusual right-sided accessory pathway that inserted in the anterior right ventricle, 2 cm away from the lateral tricuspid annulus (1 patient, 1.5%); and 10) unexplained factors (7 patients, 11%). The most common effective strategies employed to achieve a successful outcome in these patients were 1) substitution of a more experienced operator; 2) use of ablation catheters of varying configurations; 3) switching from a retrograde aortic to a trans-septal approach; 4) switching from an inferior to a superior vena caval approach; 5) use of a 60-cm guiding sheath; 6) detailed mapping of the atrial or ventricular insertion of the accessory pathway; and 7) searching within the coronary sinus for a presumed accessory pathway potential. CONCLUSIONS: A lengthy or failed attempt at catheter ablation of an accessory pathway may be due to a variety of reasons, the most common of which are problems related to some aspect of catheter manipulation and errors in accessory pathway localization. Knowledge of the most common reasons for a lengthy or ineffective procedure may facilitate successful outcome of accessory pathway ablation.

Adult↗

QT dispersion in nonsustained ventricular tachycardia and coronary artery disease.

This study examines the relation between QT dispersion and the inducibility of ventricular tachycardia (VT) in 35 consecutive patients with coronary artery disease who underwent electrophysiologic testing for evaluation of nonsustained VT. The mean age of the patients was 66 +/- 9 years (+/- SD) and the mean left ventricular ejection fraction was 0.36 +/- 0.14. In 6 patients in whom sustained, monomorphic VT was inducible by programmed ventricular stimulation, QT dispersion was significantly greater than in the 29 patients in whom VT was not inducible (126 +/- 35 vs 67 +/- 25 ms, p < 0.001). All patients who had a QT dispersion > 120 ms had inducible sustained monomorphic VT, and no patient who had a QT dispersion < 90 ms had inducible VT. The patients who had inducible VT dis not differ significantly from those who did not with regard to age, gender, ejection fraction, RR interval, or mean QT. In conclusion, in patients with coronary artery disease who have nonsustained VT, inducibility of monomorphic VT is associated with an increase in QT dispersion. QT dispersion may be helpful in predicting which patients with nonsustained VT are and are not likely to have inducible VT by programmed stimulation.

Aged↗