[The effect of local anesthetics on blood coagulation].
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to M Hübler.
Explore the source record for details and available documents.
A 45-year-old man with cryptorchism, who was known to suffer from generalized myasthenia gravis, was admitted to hospital for surgical treatment using laparoscopy. Such minimally invasive surgery requires good muscle relaxation. However, the use of neuromuscular blocking agents in patients with myasthenia gravis may lead to prolonged apnoea after operation, thus necessitating mechanical ventilation of the lungs. We used a combination of general anaesthesia (with desflurane), and epidural anaesthesia (with the amide local anaesthetic ropivacaine) to obtain excellent abdominal relaxation during surgery. Tracheal extubation was possible immediately after the operation and no adverse effects were observed. The patient was discharged from hospital on the second day after operation. The combination of regional and general anaesthesia for minimally invasive surgery in this patient permitted safe anaesthetic management.
The aim of this study was to evaluate the relationship between the kinetic patterns of the protein S-100beta, an astroglial cell marker, and its immunohistochemical expression in the brain in rabbits that underwent cardiopulmonary bypass with deep hypothermic circulatory arrest. Fourteen New Zealand rabbits (weight, 3.1+/-0.25 kg) were anaesthetised, intubated and mechanically ventilated. Four animals were not connected to the cardiopulmonary bypass and served as controls. Ten animals were perfused according to a uniform protocol. After systemic cooling, deep hypothermic circulatory arrest was induced for 60 minutes. After reperfusion and rewarming, the animals were weaned from bypass and sacrificed. In the brain, astrocyte reactivity for S-100beta was evaluated immunocytochemically (DPC Immustain) and the serum concentrations of S-100beta were analysed using a commercially available immunoluminometric kit (Byk-Sangtec, Dietzenbach, Germany). In all experimental animals a significant increase of the serum concentration of the protein S-100beta was found immediately after reperfusion and the termination of cardiopulmonary bypass. In comparison with the control animals, increased staining of S-100beta was found in the astroglial cells and swollen astrocytic end-feet in the perivascular regions. There were fewer signs of neuronal cell injury of neurones in the hippocampus structure. In conclusion, astrocytic activation and S-100beta overexpression seems to precede the neurodegeneration following deep hypothermic circulatory arrest. The marked perivascular cell swelling may support the assumption of reperfusion injury of the astroglial cell complex that forms the blood-brain barrier, which may be indicative of the source of the released S-100beta into the blood stream.
BACKGROUND AND AIM OF THE STUDY: Annular stability is not guaranteed after mitral repair without a prosthetic ring. We introduce a newly developed plication technique and detail its stabilizing effect on the mitral annulus after Gerbode plasty. METHODS: Patients suffered degenerative mitral valve prolapse with chordal rupture restricted to the middle scallop of the posterior leaflet. Between 1986 and 1997, 102 patients underwent Gerbode plasty with or without annular reinforcement with a pericardial strip or modified Paneth plasty (group C). The mean (+/- SD) follow up was 70.4 +/- 41.1 months. Since 1996, 32 patients have undergone a newly developed annuloplasty technique (group N), where a pericardial strip was tightly anchored to the bilateral trigones and posterior annulus, which was folded by Gerbode plasty. With the final anchoring suture the intention was to prevent plication breakdown of this portion. Mean follow up for this group was 17.6 +/- 7.1 months. Progression of mitral regurgitation after surgery in both groups was studied. RESULTS: In group C, postoperative progression of mitral valve regurgitation occurred in 41.1% of patients (5.9% to grade 1, 17.6% to grade 2, 17.6% to grade 3). Among these patients, reoperation was due to plication breakdown of the Gerbode plasty in six cases (5.9%), and to either chordal rupture or annular dilatation in 10 cases each (9.8%). In contrast, no reoperation due to recurrent severe mitral regurgitation was needed in group N. Progression of mitral regurgitation after surgery was seen in six patients (two to grade 1; four to grade 2). CONCLUSION: The newly developed annuloplasty technique may be useful in stabilizing the mitral annulus after Gerbode plasty.
BACKGROUND: The continual shortage of hearts for transplantation (HTx) led to the expansion of the donor pool by accepting older donors. We compared the medium-term follow-up of patients after HTx with older hearts (over the age of 63 years) with those of patients after HTx with younger hearts. PATIENTS AND METHODS: Since April 1994 we have used hearts for HTx from donors older than the age of 63 years. Until November 1998, 309 HTx and 9 re-HTx were performed in 309 adults with a mean age of 50.7+/-10.9 years (range 17-68 years). There were 252 men and 57 women. The patients were divided into two groups: group I--donor age under 63 years (296 patients, mean age 50.4+/-11 years; mean donor age 38.1+/-13 years; mean follow-up 1.7+/-1.6 years); group II-donor age of more than 63 years (13 patients, mean age 57.4+/-5.6 years; mean donor age 65.1+/-2.1; mean follow-up 2.2+/-1.6 years). There were no differences in the etiology of heart failure, gender, or ischemia time between the groups. The patients in group II were significantly older (P = 0.008). Multiple factors were analyzed in the groups, which included changes in the left/right ventricle ejection fraction, early postoperative mortality (up to 30 days), cumulative survival rates and cardiac-dependent morbidity [myocardial infarction, malignant arrhythmias, coronary stenosis (>50% in one of the main coronary arteries) and transplant vasculopathy]. Additionally, freedom from cytomegalovirus infection (rise of titer or seroconversion) and freedom of acute rejection episodes grade > or =2 (International Society of Heart & Lung Transplantation [ISHLT]) were analyzed. RESULTS: After 1 year mean left and right ventricle ejection fraction were good in both groups and did not significantly change for up to 2 years. No Re-HTx was performed in group II. The early postoperative mortality was similar in both groups (P = 0.8). Also, the cumulative survival rates were similar in both groups (P = 0.87). Long-term cardiac morbidity was lower in group I (P = 0.03). The long-term freedom from cytomegalovirus infection in group I was significantly higher when compared with group II (P = 0.0002). The long-term freedom from severe rejection episodes was similar in both groups (P = 0.3) CONCLUSION: The study found a significant increase in long-term cardiac morbidity due to more focal coronary stenosis in group II, and freedom from cytomegalovirus infection, but did not find significant differences in the long-term survival between patients who received hearts from donors of up to 63 years of age and from those more than 63 years. The acceptance of donors older than 63 years old for HTx does not worsen the outcome of the recipients. The careful selection of older donors, with close monitoring of the coronary situation after HTx and expanded indications for revascularization of older hearts, could make HTx with older hearts, even in older recipients, a safe option.
BACKGROUND: Perfluorocarbon liquids are being used experimentally and in clinical trials for the treatment of acute lung injury. Their resemblance to inhaled anesthetic agents suggests the possibility of application by vaporization. The authors' aim was to develop the technical means for perfluorocarbon vaporization and to investigate its effects on gas exchange and lung function in an ovine model of oleic acid-induced lung injury. METHODS: Two vaporizers were calibrated for perfluorohexane and connected sequentially in the inspiratory limb of a conventional anesthetic machine. Twenty sheep were ventilated in a volume controlled mode at an inspired oxygen fraction of 1.0. Lung injury was induced by intravenous injection of 0.1 ml oleic acid per kilogram body weight. Ten sheep were treated with vaporized perfluorohexane for 30 min and followed for 2 h; 10 sheep served as controls. Measurements of blood gases and respiratory and hemodynamic parameters were obtained at regular intervals. RESULTS: Vaporization of perfluorohexane significantly increased arterial oxygen tension 30 min after the end of treatment (P < 0.01). At 2 h after treatment the oxygen tension was 376+/-182 mmHg (mean +/- SD). Peak inspiratory pressures (P < 0.01) and compliance (P < 0.01) were significantly reduced from the end of the treatment interval onward. CONCLUSION: Vaporization is a new application technique for perfluorocarbon that significantly improved oxygenation and pulmonary function in oleic acid-induced lung injury.
The aim of the study was to validate a nonradioactive method for relative blood flow measurements in severely injured lungs that avoids labor-intensive tissue processing. The use of fluorescent-labeled microspheres was compared with the standard radiolabeled-microsphere method. In seven sheep, lung injury was established by using oleic acid. Five pairs of radio- and fluorescent-labeled microspheres were injected before and after established lung injury. Across all animals, 175 pieces were selected randomly. The radioactivity of each piece was determined by using a scintillation counter. The fluorescent dye was extracted from each piece with a solvent without digestion or filtering. The fluorescence was determined with an automated fluorescent spectrophotometer. Perfusion was calculated for each piece from both the radioactivity and fluorescence and volume normalized. Correlations between flow determined by the two methods were in the range from 0.987 +/- 0.007 (SD) to 0.991 +/- 0.002 (SD) after 9 days of soaking. Thus the fluorescent microsphere technique is a valuable tool for investigating regional perfusion in severely injured lungs and can replace radioactivity.
Explore the source record for details and available documents.
The mechanism of left ventricular outflow tract (LVOT) obstruction in the patient after mitral valve replacement or repair was examined with the aid of 2D echocardiography. For the interpretation of the spatial relationship between the aortic root and mitral annulus, however, the 2D display is sometimes inadequate since it may not simultaneously capture these structures in each center. We developed a method to clarify this relationship in 3D based on magnetic resonance images. We defined the office of the left ventricular outflow tract (LVOT orifice), consisting of, in turn, a muscular region, i.e., edge of the interventricular septum, and an annular region, i.e., the annulus of the anterior mitral leaflet. In this paper we present image data obtained from one of eight normal subjects examined and compare this with data of one of two patients who preoperatively suffered degenerative mitral regurgitation and subsequently underwent chordal-preserving mitral valve replacement, in which anterior chordae were reattached to the anterior annulus. In the normal subject, the mitral annulus exhibited a flexible change in shape during the systole, maintaining sufficient LVOT orifice size. In the patient, the prosthetic valve exhibited translational motion during systole, resulting in dynamic LVOT obstruction. This phenomenon was also observed in one other case. Furthermore, the lateral view of the LVOT orifice revealed a projection of the prosthetic valve into the LVOT, causing mechanical LVOT obstruction. The finding that translational motion of the prosthetic valve with an inflexible mitral annulus results in dynamic LVOT obstruction may support the hypothesis that annular rigidity causes dynamic LVOT obstruction after mitral valve repair with a rigid prosthetic ring.
We compared the left ventricular Tei index measured by tissue Doppler imaging (TDI) to that obtained by pulsed Doppler (PW) in patients with congenital heart disease. In 40 consecutive patients with a variety of congenital and acquired heart diseases, the left ventricular (LV) PW Doppler-derived Tei index was assessed on-line as previously described. TDI-derived anatomic curved M-mode and the unprocessed velocity trace from the basal septum were used to time the opening and closure of the mitral and aortic valves in one cardiac cycle, respectively. The TDI Tei index was calculated off-line according to the equation (isovolumetric relaxation time + isovolumetric contraction time)/ ejection time. The Tei index calculated from TDI correlated significantly with that measured by pulsed Doppler (r = 0.92, p = 0.001). The mean difference (range) between pulsed Doppler-derived Tei index and TDI-derived Tei index was 0.005 (-0.07-0.06), which was within the limits of agreements. Interobserver variability for the TDI-derived Tei index was 5 +/- 3%. The TDI Tei index can be used to assess the global LV function in patients with congenital heart disease. In contrast to the PW Doppler-derived Tei index, the TDI-derived Tei index obtained from the same cardiac cycle may help to differentiate systolic from diastolic dysfunction by providing specific information on the isovolumetric intervals.
Although chordal preserving mitral valve replacement is beneficial to cardiac function, the loss of flexibility of the annulus and consequent translational motion of the valve prosthesis during systole may cause potential left ventricular outflow tract (LVOT) obstruction after surgery. The extent of the flexibility of the mitral valve annulus (MVA) necessary for the prosthetic valve to prevent potential LVOT obstruction was determined. The three dimensional images of the MVA at 0, 100, 200, and 300 msec delay from the electrocardiogram R wave were reconstructed from cine-mode magnetic resonance images in eight normal subjects. In the lateral view of the MVA, the dorsal flexion angle (DFA) was defined. This angle implies the extent of the flexion of the anterior half of the MVA in relation to the posterior half. The data (mean +/- SD) for the DFA were 31.7 +/- 5.4 degrees (0 msec), 36.4 +/- 4.5 degrees (100 msec), 39.0 +/- 3.8 degrees (200 msec), and 43.6 +/- 2.6 degrees (300 msec), whereas the systolic increase in DFA was 11.9 +/- 3.2 degrees. The flexibility observed in normal mitral annuli is relevant to prosthetic mitral valves.
Mitral annular inflexibility due to rigid prostheses (ring or valve) has long been considered to contribute to the mechanism of dynamic left ventricular outflow tract (LVOT) obstruction after mitral repair or replacement. In clarifying the geometric relationship between LVOT orifice and mitral valve annulus (MVA) in eight normal subjects, the authors have endeavored to show how that a rigid mitral prosthesis might obstruct the LVOT based on the assumption that any rigid prosthesis necessarily follows the motion of the posterior half of the MVA (MVApost) in the course of every heart beat. During systole, the relationship between the MVApost and the approximated plane of the LVOT orifice was constant. However, with the respect to the relationship between the LVOT orifice and the approximated plane of the MVApost (PI-MVApost), the intersection between the two shifted toward the apex during systole. Assuming the prosthesis is aligned on the MVApost with the same orientation as the PI-MvApost, this shift implies a reduction in the effective size of the LVOT orifice due to the prosthesis. The calculated obstruction rate was 24.9% (0 ms), 30.9% (100 ms), 35.5% (200 ms), and 45.4% (300 ms). These results indicate the importance of maintaining the flexibility of the MVA after mitral valve surgery.
An analysis of three-dimensional movement of the mitral valve annulus (MVA) may address the question of geometrical change after mitral valve repair to preserve mitral annular function. Conventionally, annular contraction has been studied for this purpose. We investigated this geometrical change occurring in the anterior half of the MVA and discuss its clinical significance. Three-dimensional images of the MVA during systole were reconstructed from magnetic resonance images of eight normal subjects. The posterior half of the MVA exhibited translational motion. We assume that this portion, exhibiting translational motion as well as contraction, purely follows the motion of the left ventricular contraction. Compensating for the discrepancy between the motion of the aortic root and that of the posterior half of the MVA, the anterior half exhibited a flexible change in shape during systole, thus maintaining a sufficient left ventricular outflow tract (LVOT). The increase in the extent of displacement of the anterior MVA from the posterior half of the MVA during systole, which was 3.6 +/- 1.0 mm (mean +/- SD), indicates the annular flexibility. The preservation of annular flexibility may prevent LVOT obstruction. Further geometrical analysis of patients after mitral repair will clarify annular function as presented in this article.
To evaluate the narrowing of the left ventricular outflow tract (LVOT) during systole caused by a rigid mitral prosthesis, the geometric relationship between the prosthesis (or the mitral annulus) and the left ventricular base (LVB) was studied in five patients with mechanical mitral valve prostheses and eight normal subjects. The images of the mitral valve annulus (MVA) and the LVOT orifice reconstructed in three dimensions were projected on the plane of the LV base. Calculating the areas of these projected images (i.e., those for MVA [Sm], LVOT orifice [So], the LVB [Sb; Sb = Sm + So]), the MVA-LVB ratio (Sm/Sb) was determined. In the normal subject, the MVA-LVB ratio was nearly constant during systole (59 +/- 5% at 0 msec and 62 +/- 7% at 300 msec, respectively), whereas in the patients with prostheses, the ratio increased from 61 +/- 4% (0 msec) to 69 +/- 4% (300 msec). The increase in MVA-LVB ratio reduces the proportionate share of LVOT orifice in relation to the total LVB. The ideal mitral valve prosthesis should be flexible at the annulus to attain good performance in LVB dynamics.