Search PubMed⌕ Search

Biomedical subjects

M H Picard

Publications and source records attributed to M H Picard.

At least 55 records · Page 3Linked to original sources

Factors influencing regional myocardial contractile response to inotropic stimulation. Analysis in humans with stable ischemic heart disease.

BACKGROUND: We hypothesized that the response of a myocardial segment to maximal dobutamine reflects not only maximal blood flow but also tethering, metabolic, and beta-blocker status. METHODS AND RESULTS: Patients with stable ischemic heart disease (n = 27) had positron emission tomographic measurement of blood flow at rest and with adenosine, and echocardiography at rest and with dobutamine. Positron emission tomographic measurement of [18F]fluorodeoxyglucose myocardial distribution also was made. Adenosine blood flow in segments that contracted normally at peak dobutamine was similar to that of segments that became hypokinetic (1.06 +/- 0.72 versus 1.02 +/- 0.77 mL.g-1.min-1). Segments that became akinetic failed to augment blood flow (0.68 +/- 0.30 mL.g-1.min-1). Fluorodeoxyglucose-blood flow mismatch was more common in segments with abnormal wall motion at peak dobutamine (24 of 59, 41%) versus those that contracted normally (63 of 269, 23%; chi 2, 7.40; P < .01). In patients off beta-blockers, segments that contracted normally at peak dobutamine increased blood flow with adenosine (0.70 +/- 0.31 to 0.86 +/- 0.46 mL.g-1.min-1; P < .05), whereas those that became abnormal did not (0.63 +/- 0.24 to 0.65 +/- 0.19 mL.g-1.min-1; P = NS). Segments of patients on beta-blockers that contracted normally at peak dobutamine increased blood flow with adenosine (0.78 +/- 0.31 to 1.10 +/- 0.70 mL.g-1.min-1; P < .05), as did segments that became abnormal (0.74 +/- 0.34 to 1.06 +/- 0.82 mL.g-1.min-1; P = NS). However, segments adjacent to ones with abnormal wall motion at rest had higher frequency of abnormal response at peak dobutamine in groups on (48% versus 16%; chi 2, 14.1; P < .001) and off (51% versus 21%; chi 2, 10.9; P < .01) beta-blockers. CONCLUSIONS: Augmented contraction at maximal dobutamine depends not only on increased myocardial blood flow but also on tethering, metabolic, and beta-blocker status. Furthermore, impaired flow reserve does not preclude a normal response to maximal dobutamine, since blood flow need not increase greatly to meet demand.

Adenosine↗

Biopsy-induced flail tricuspid leaflet and tricuspid regurgitation following orthotopic cardiac transplantation.

Damage to the tricuspid valve apparatus has been described after endomyocardial biopsy and may be associated with hemodynamically significant tricuspid regurgitation (TR). This study was performed to determine the prevalence of TR and flail tricuspid leaflet in cardiac transplant recipients and to evaluate the use of a 45 cm sheath placed directly in the right ventricle during endomyocardial biopsy to reduce the incidence of these complications. Echocardiograms and right heart catheterization data of 72 orthotopic cardiac transplant recipients were assessed for the presence of flail tricuspid leaflet, TR, and right-sided cardiac dysfunction 29 +/- 20 months (mean +/- SD) after transplantation. Moderate or severe TR was present in 23 patients (32%). Ten patients (14%) had flail tricuspid leaflet, with 7 of these having severe TR. Right atrial pressure (10 +/- 5 vs 6 +/- 5 mm Hg, p < 0.05) was higher, cardiac index (2.0 +/- 0.2 vs 2.5 +/- 0.7 L/min/m2, p < 0.05) was lower, and right-sided cardiac dimensions were greater in patients with flail leaflets than in those without flail leaflets. Both the prevalence of flail tricuspid leaflet (41% to 6%, p < 0.0001) and mean grade of TR (2 to 1, p < 0.0001) were reduced after the use of a 45 cm sheath. We conclude that TR secondary to biopsy-induced damage to the valve apparatus occurs in cardiac transplant recipients and is associated with signs of early right-sided heart failure. Use of a 45 cm sheath during endomyocardial biopsy reduces the prevalence of flail tricuspid leaflet and the severity of TR.

Biopsy↗

Determination of aortic valve area in valvular aortic stenosis by direct measurement using intracardiac echocardiography: a comparison with the Gorlin and continuity equations.

OBJECTIVES: This study sought to 1) show that intracardiac echocardiography can allow direct measurement of the aortic valve area, and 2) compare the directly measured aortic valve area from intracardiac echocardiography with the calculated aortic valve area from the Gorlin and continuity equations. BACKGROUND: Intracardiac echocardiography has been used in the descriptive evaluation of the aortic valve; however, direct measurement of the aortic valve area using this technique in a clinical setting has not been documented. Despite their theoretical and practical limitations, the Gorlin and continuity equations remain the current standard methods for determining the aortic valve orifice area. METHODS: Seventeen patients underwent intracardiac echocardiography for direct measurement of the aortic valve area, including four patients studied both before and after valvuloplasty, for a total of 21 studies. Immediately after intracardiac echocardiography, hemodynamic data were obtained from transthoracic echocardiography and cardiac catheterization. RESULTS: Adequate intracardiac echocardiographic images were obtained in 17 (81%) of 21 studies. The average aortic valve area (mean +/- SD) determined by intracardiac echocardiography for the 13 studies in the Gorlin analysis group was 0.59 +/- 0.18 cm2 (range 0.37 to 1.01), and the average aortic valve area determined by the Gorlin equation was 0.62 +/- 0.18 cm2 (range 0.31 to 0.88). The average aortic valve area determined by intracardiac echocardiography for the 17 studies in the continuity analysis group was 0.66 +/- 0.23 cm2 (range 0.37 to 1.01), and that for the continuity equation was 0.62 +/- 0.22 cm2 (range 0.34 to 1.06). There was a significant correlation between the aortic valve area determined by intracardiac echocardiography and the aortic valve area calculated by the Gorlin (r = 0.78, p = 0.002) and continuity equations (r = 0.82, p < 0.0001). CONCLUSIONS: In the clinical setting, intracardiac echocardiography can directly measure the aortic valve area with an accuracy similar to the invasive and noninvasive methods currently used. This study demonstrates a new, quantitative use for intracardiac echocardiographic imaging with many potential clinical applications.

Aged↗

Absence of Q waves after thrombolysis predicts more rapid improvement of regional left ventricular dysfunction.

Although the natural history of regional left ventricular (LV) dysfunction after Q-wave and non-Q-wave myocardial infarction (MI) was well defined in the prethrombolytic era, the functional and structural implications of the absence of Q waves after thrombolysis are less clear. Echocardiography was performed within 48 hours of admission (entry) in 86 patients treated with thrombolysis for their first MI. The extent of abnormal wall motion (AWM; square centimeters) and LV endocardial surface area index (ESA; square centimeters per square meters) were quantified by using a previously validated echocardiographic endocardial surface-mapping technique. Electrocardiography (ECG) performed at 48 hours after thrombolysis was used to classify patients into groups with (Q; n=70) and without (non-Q; n=16) Q waves. All patients in the Q group had regional LV dysfunction on initial echocardiogram compared with 69 percent of those in the non-Q group (p<0.001). When the patients in the non-Q group without AWM were excluded from analysis, there was no significant difference in the extent of AWM between the Q and non-Q groups. Among those patients with AWM on entry, follow-up echocardiography at 6 to 12 weeks demonstrated a significant reduction in extent of AWM for both the Q and non-Q groups. However, the fractional change in AWM was significantly greater in the non-Q than in the Q group (-0.74 +/- 0.28 vs -0.29 +/- 0.44; p<0.02), with a trend toward less AWM at follow-up in the non-Q than in the Q group. The mean ESAi was not significantly different between the two groups at entry or at follow-up. In conclusion, failure to develop Q waves after thrombolysis predicts a lower likelihood of developing regional LV dysfunction and, when such dysfunction is present, predicts a greater degree of recovery.

Aged↗

Effect of beta-blockade on dobutamine stress echocardiography.

Dobutamine is an effective pharmacologic stress used in conjunction with echocardiography because of its beta-agonist properties. Concurrent beta-blockade might alter this effectiveness; however, current clinical experience has been variable. The purpose of this study is to determine whether concurrent beta-blockade alters the ability of a dobutamine stress echocardiogram to detect a fixed coronary stenosis by preventing the onset of a wall motion abnormality or by altering the dose at which the wall motion abnormality appears. Paired dobutamine stress tests with and without beta-blockade (esmolol 500 microgram/kg initial bolus, 100 microg/kg/min infusion) were performed in a canine model (n = 8) with a fixed single-vessel coronary stenosis. Heart rate, systolic pressure, proximal left anterior descending coronary flow, myocardial thickening (by sonomicrometry), and left ventricular area change (by epicardial echocardiography) were monitored. Simultaneous beta-blockade resulted in (1) a delayed and diminished increase in hemodynamic parameters (peak heart rate 164.1 +/- 22.3 without beta-blockade vs 110.1 +/- 28.9 beats/min with beta-blockade, p < 0.001, and peak systolic blood pressure 137.9 +/- 26.8 mm Hg without beta-blockade vs 107.3 +/- 15.3 mm Hg with beta-blockade, p = 0.01), (2) an elimination of the physiologic effects of low-dose (5 and 10 microg/kg/min) dobutamine (-0.7 percent +/- 16.7 percent change in myocardial thickening from baseline with beta-blockade, p = NS), and (3) an elimination or alteration in timing of inducible wall motion abnormalities caused by severe coronary artery stenoses (mean termination dose 28.8 +/- 9.9 with beta-blockade vs 15.6 +/- 6.1 microg/kg/min without beta-blocker, p < 0.01). The findings in this canine model suggest that the competitive antagonist markedly attenuates the ability of dobutamine stress echocardiography to detect a significant coronary lesion and may alter its ability to detect viable myocardium at low-dose testing. Further clinical studies to determine the sensitivity of dobutamine stress echocardiography in the presence of beta-blockers and to establish protocol standards are necessary.

Adrenergic beta-Agonists↗

Quantitative three-dimensional reconstruction of left ventricular volume with complete borders detected by acoustic quantification underestimates volume.

Recently a new acoustic-quantification (AQ) technique has been developed to provide on-line automated border detection with an integrated backscatter analysis. Prior studies have largely correlated AQ areas with volumes without direct comparison of volumes for agreement. By using complete AQ-detected borders as the input to a validated method for three-dimensional echocardiographic (3DE) reconstruction, we can compare an entire cavity volume measured with the aid of AQ against a directly measured volume. This would also explore the possibility of applying AQ to 3DE reconstruction to reduce tracing time and enhance routine applicability. To compare reconstructed volumes with actual values in a stable standard allowing direct volume measurement, the left ventricles of 13 excised animal hearts were studied with a 3DE system that automatically combines two-dimensional (2D) images and their locations. Intersecting 2D views were obtained with conventional scanning and AQ imaging, with gains optimized to permit 3D reconstruction by detecting the most continuous AQ borders for each view, with maximal cavity size. Reconstruction was performed with manually traced central endocardial reflections and AQ-detected borders visually reproduced the left ventricular shapes; the AQ reconstructions, however, were consistently smaller. The reconstructed left ventricular (LV) volumes correlated well with actual values by both manual and AQ techniques (r = 0.93 and 0.88, with standard errors of 2.3 cc and 2.0 cc, p = not significant [NS]). Agreement with actual values was relatively close for the manually traced borders (y = 0.93x + 0.68, mean difference = -0.8 +/-2.2 cc). AQ-derived reconstructions consistently underestimated LV volume by 39 +/- 10% (y = 0.62x-0.09, mean difference = -7.8 +/- 3.0 cc, different from manually traced and actual volumes by analysis of variance [ANOVA], F = 69, p<0.00001). The AQ-detected threshold signal was displaced into the cavity, and volume between walls and false tendons was excluded, leading to underestimation, which increased with increasing cavity volume (r = 0.76). The AQ technique can therefore be applied to 3DE reconstruction, providing volumes that correlate well with directly measured values in a stable in vitro standard, minimizing observer decisions regarding manual border placement after image acquisition. However, when the complete borders needed for 3D reconstruction are used, absolute volumes are underestimated with current algorithms that integrate backscatter and displace the detected threshold into the ventricular cavity.

Animals↗

Prevalence and timing of regional myocardial dysfunction after rotational coronary atherectomy.

OBJECTIVES: This study aimed to evaluate the prevalence and time course of wall motion abnormalities associated with rotational coronary atherectomy. BACKGROUND: Although initial clinical studies found evidence of transient wall motion abnormalities after rotational coronary atherectomy, the prevalence and duration of these wall motion abnormalities are unknown. METHODS: Using simultaneous echocardiography, we prospectively evaluated 22 patients undergoing rotational atherectomy and compared their wall motion abnormalities with those of 10 patients undergoing coronary angioplasty alone. The extent of wall motion abnormality was quantified and plotted against time to produce curves of abnormal wall motion development and recovery for the two groups. RESULTS: The cumulative ischemic time was similar for the two groups ([mean +/- SD] 10.3 +/- 6 min for rotational atherectomy vs. 9.6 +/- 4.2 min for coronary angioplasty, p = 0.73). The rate of return to baseline function was significantly lower in the rotational atherectomy group than in the coronary angioplasty group (rotational atherectomy rate constant 0.069 +/- 0.079/min vs. coronary angioplasty rate constant 1.250 +/- 0.47/min, p = 0.0001). The mean time to recovery of baseline wall motion in the rotational atherectomy group (153 min, 95% confidence interval [CI] 6.5 to 3,600) was significantly longer than in the coronary angioplasty group (2.6 min, 95% CI 1.3 to 5.5, p = 0.0001). Rotational atherectomy burr time was longer in the patients who developed myocardial infarction than in those without myocardial infarction (4.7 +/- 2.4 vs. 3 +/- 1.4 min, p = 0.045). CONCLUSIONS: Transient wall motion abnormalities are common after rotational coronary atherectomy and have a longer duration than those observed after coronary angioplasty. This disparity may be a consequence of differences in the mechanisms by which rotational coronary atherectomy and coronary angioplasty produce their effect.

Aged↗

Percutaneous transvenous intracardiac ultrasound imaging in dogs: a new approach to monitor left ventricular function.

OBJECTIVE: To evaluate the feasibility and ability of percutaneous transvenous intracardiac echocardiography (ICE) to image the left ventricle (LV) and monitor its function from the right ventricular (RV) cavity. METHODS: A 10 MHz catheter was advanced into the RV from the jugular vein and positioned along the septum at the LV papillary muscle level in five dogs. The catheter was manipulated until a stable catheter position along the septum, which provided on-axis images of LV, was obtained. Different states of LV size and systolic function (n = 80) were created with dobutamine or esmolol, both in the presence and absence of coronary stenoses. LV stroke area (cm2) obtained by ICE was measured at the mid-ventricular level and compared with stroke volume (cm3) obtained simultaneously with a transaortic flow probe. LV end diastolic, end systolic, and stroke areas obtained by ICE were also compared with those obtained by short-axis epicardial echocardiography. RESULTS: In 96% of the stages, short axis images of the LV could be obtained and measured by ICE. LV end diastolic, end systolic, and stroke areas measured by ICE were not significantly different from epicardial echocardiographic values. Stroke area correlated with stroke volume in each dog (mean correlation coefficient 0.79 (SEE 0.19) cm2) (P < 0.001). CONCLUSIONS: Percutaneous intracardiac ultrasound imaging allows monitoring of LV function from the RV with an accuracy comparable to a short-axis epicardial echocardiogram. The present device can be used in closed chest experimental studies. With the development of lower frequency devices, this technique may be valuable for continuous monitoring of LV function in patients in the intensive care unit or operating room.

Animals↗

LEW-to-F344 carotid artery allografts: analysis of a rat model of posttransplant vascular injury involving cell-mediated and humoral responses.

A key manifestation of chronic rejection is an obliterative arteriosclerosis. Myointimal thickening in the vessel is preceded by an endothelialitis involving accumulation of host mononuclear cells in the perivascular and intimal spaces. We report a paratopic LEW-to-F344 rat carotid artery transplantation model developed to study the cells, cytokines, and inflammatory response associated with this early phase of vascular immune injury. Compared with contralateral control arteries and isografts, LEW-to-F344 carotid allografts develop intimal thickening with mononuclear cell infiltration that persists (days 20, 45, 75, 90, and 120). Allografted vessels had dense collections of intimal and adventitial leukocytes (CD45+) consisting of equal numbers of T cells and macrophages. There were small but variable numbers of intimal smooth muscle cells. Intimal cells showed dense staining for tumor necrosis factor-alpha, interleukin-8, platelet-derived growth factor, iNOS, and ICAM and weaker labeling for interleukin-1 beta and interleukin-6. There was also prominent staining for interleukin-4 and interleukin-7 with no detectable interferon-gamma or interleukin-2 staining and high titer labeling for IgG1 (but not IgG2). The predominance of the T cell infiltrate coupled with interleukin-4 and IgG1 expression in carotid allografts is consistent with a TH2 response. This contrasts with balloon-injured rat carotids, which evoke a macrophage-dependent proliferative response. These findings demonstrate that there are distinct as well as common activation pathways in various forms of vascular injury and the LEW-to-F344 carotid model provides the opportunity to gain insight into molecular mechanisms regulating alloimmune injury in the vessel.

Animals↗

Optimal stage duration in dobutamine stress echocardiography.

OBJECTIVES: This study attempted to determine the benefit of a 5-min dobutamine stress echocardiographic stage versus a 3-min stage in a canine model. BACKGROUND: Dobutamine stress echocardiography, as currently performed, uses a variety of different protocols. Among the many aspects of dobutamine stress echocardiographic protocols that vary is stage duration. Because dobutamine has specific pharmacodynamics, it is possible that stages of different durations may have different cardiovascular effects. METHODS: Paired dobutamine stress echocardiograms were obtained in 10 open chest instrumented dogs. The stage duration for the initial dobutamine stress echocardiogram was randomly allocated to either 3 or 5 min, and all hemodynamic and echocardiographic variables were allowed to return to baseline before the second dobutamine stress echocardiogram was obtained using the alternative stage duration. At each stage, heart rate, systolic blood pressure, coronary flow, myocardial wall thickness and left ventricular cavity area were recorded. Cavity obliteration, hypotension, ventricular tachycardia or a maximal dose of 40 micrograms/kg body weight per min served as the dobutamine stress echocardiographic end point. RESULTS: At baseline, no difference was detected between the 3- or 5-min protocols for heart rate, systolic blood pressure, rate-pressure product, coronary blood flow, wall thickness or percent area change. Heart rate, systolic blood pressure and coronary flow increased more by the 10-micrograms/kg per min dose with the 5-min protocol than with the 3-min protocol. The dobutamine stress echocardiographic end points were achieved at a lower dobutamine dose (15.0 +/- 4.1 vs. 11.0 +/- 2.1 micrograms/kg per min [mean +/- SD], p = 0.01) with the longer stage duration. CONCLUSIONS: In this canine model, a longer stage produced a greater hemodynamic effect at a lower peak dose. Thus, extending stage duration in clinical dobutamine stress echocardiography may achieve equivalent physiologic stress at lower doses and contribute to the optimization of dobutamine stress echocardiographic protocols.

Animals↗

Quantitative three-dimensional reconstruction of aneurysmal left ventricles. In vitro and in vivo validation.

BACKGROUND: Current two-dimensional (2D) echocardiographic measures of left ventricular (LV) volume are most limited by aneurysmal distortion, which restricts application of simple geometric models that assume symmetrical shape. 2D methods also fail to provide separate volumes of the aneurysm and nonaneurysmal residual LV cavity, which could help assess the stroke volume wasted by dyskinesis and the potential residual LV body to guide surgical approaches and predict their outcome. Three-dimensional (3D) echocardiographic reconstruction has potential advantages for assessing aneurysmal left ventricles because it is not dependent on geometric assumptions, does not require standardized views that may exclude portions of the aneurysm, and can potentially measure separate aneurysm and nonaneurysm cavity volumes of any shape. The purpose of this study was first, to validate the accuracy of 3D echocardiographic reconstruction for quantifying total LV and separate LV body and aneurysm volumes in vitro so as to provide direct standards for the separate volumes; and second, to determine the feasibility and accuracy of 3D echocardiographic reconstruction for quantifying the total volume and function of aneurysmal left ventricles in an animal model, providing a reference standard for instantaneous LV volume. METHODS AND RESULTS: A recently developed 3D system that automatically combines 2D images and their locations was applied (1) to reconstruct 10 aneurysmal ventricular phantoms and 12 gel-filled autopsied human hearts with aneurysms, comparing cavity volumes (total and aneurysm) to those measured by fluid displacement; and (2) to reconstruct the left ventricle during 19 hemodynamic stages in four dogs with surgically created LV aneurysms, comparing total volumes with actual instantaneous values measured by an intracavitary balloon attached to an external column for validation and also calculating the stroke volume wasted by aneurysmal dyskinesis. 3D reconstruction reproduced the distorted aneurysmal LV shapes. In vitro, calculated volumes (aneurysm, nonaneurysm, and total) agreed well with actual values, with correlation coefficients of .99 and SEEs of 3.2 to 6.1 cm3 for phantoms and 3.4 to 4.2 cm3 for autopsied hearts (mean error, < 4% for both). In vivo, LV end-diastolic, end-systolic, and stroke volumes as well as ejection fraction calculated by 3D echocardiography correlated well with actual values (r = .99, .99, .95, and .99, respectively) and agreed closely with them (SEE = 4.3 cm3, 3.5 cm3, 1.7 cm3, and 2%, respectively). The stroke volumes wasted by the aneurysm were -20.1 +/- 19.3% of LV body (nonaneurysm) stroke volume. CONCLUSIONS: Despite distorted ventricular shapes, a recently developed 3D echocardiographic system and surfacing algorithm can accurately reconstruct aneurysmal left ventricles and quantify total LV volume (validated in vivo and in vitro) as well as the separate volumes of the aneurysm and residual LV body (validated in vitro). This should improve our ability to evaluate such ventricles and guide surgical approaches.

Algorithms↗

Effect of hydration on cavity obliteration during dobutamine stress echocardiography.

The purpose of this study was to determine whether it is possible to prevent or delay the onset of midventricular cavity obliteration during a dobutamine stress test with standard hydration. Left ventricular (LV) intracavitary obstruction has been reported as the mechanism for hypotension seen in approximately 20% of patients undergoing dobutamine stress echocardiography. In addition, it has been proposed that administration of a normal saline bolus prior to dobutamine infusion may avert the dynamic ventricular obstruction. We performed a standard graded dobutamine stress echocardiogram before and after fluid loading with 10 ml/kg of normal saline in 10 mongrel dogs. Measurements were made of left atrial pressure, aortic pressure, and the area of the LV cavity at the papillary muscle level throughout each infusion. Although hydration produced an increase in baseline left atrial pressure (5.7 +/- 3.2 to 8.1 +/- 2.7 mmHg, p < 0.01) and systolic blood pressure (128 +/- 18 to 139 +/- 22 mmHg, p = 0.03), there was no significant change in pre-dobutamine heart rate or systolic area. With dobutamine infusion, there was a similar change in heart rate, systolic blood pressure, diastolic area, and systolic area (SA) at each dose of dobutamine regardless of hydration status. In addition, the dose at which cavity obliteration occurred was not altered by hydration (p = NS). Although all dogs developed cavity obliteration (SA < 1.0 cm2) with dobutamine infusion, none experienced hypotension. In this canine model, cavity obliteration does not lead to systemic hypotension and cannot be prevented or delayed by volume loading.

Animals↗

Three-dimensional echocardiography improves noninvasive assessment of left ventricular volume and performance.

To calculate left ventricular (LV) volume by two-dimensional echocardiography (2DE), assumptions must be made about ventricular symmetry and geometry. Three-dimensional echocardiography (3DE) can quantitate LV volume without these limitations, yet its incremental value over 2DE is unknown. The purpose of this study was to compare the accuracy of LV volume determination by 3DE to standard 2DE methods. To compare the accuracy of 3DE with standard 2DE algorithms for quantitating LV volume, 28 excised canine ventricles of known volume and varying shapes (15 symmetric and 13 aneurysmal) and 10 instrumented dogs prepared so that instantaneous ventricular volume could be measured were examined by 2DE (bullet and biplane Simpson's formulas) and again by 3DE. In both excised and beating hearts, 3DE was more accurate in quantitating volume than either 2DE method (excised: error = 0.6 +/- 3.2, 2.5 +/- 10.7, and 4.0 +/- 8.5 ml by 3D, bullet, and Simpson's, respectively; beating: error = -0.5 +/- 3.5, -0.3 +/- 9.6, and -7.6 +/- 8.0 ml by 3DE, bullet, and Simpson's, respectively). This difference in accuracy between 3DE and 2DE methods was especially apparent in asymmetric ventricles distorted by ischemia or right ventricular volume overload. Stroke volume and ejection fraction calculated by 3DE also demonstrated better agreement with actual values than the bullet or Simpson methods with less variability (ejection fraction: error = -2.0% +/- 5.1%, 7.7% +/- 8.5%, and 6.8% +/- 12.3% by 3DE, bullet, and Simpson's, respectively). In both in vitro and in vivo settings, 3DE provides improved accuracy for LV volume and performance than current 2DE algorithms.

Animals↗

Quantitation of myocardial dysfunction in ischemic heart disease by echocardiographic endocardial surface mapping: correlation with hemodynamic status.

Autopsy studies have suggested that infarction of > 35% of the myocardium is associated with cardiogenic shock. However, the relation between the extent of myocardial dysfunction and hemodynamic status has not been defined in patients in vivo. This study investigated, in patients with short-term and chronic left ventricular dysfunction, the relation between hemodynamic status and the extent of regional dyssynergia measured by two-dimensional echocardiography with quantitative endocardial surface mapping. Sixty patients were classified into hemodynamic groups by pulmonary capillary wedge pressure and cardiac index. Two-dimensional echocardiograms were used to calculate left ventricular endocardial surface area index (ESAi), abnormal wall motion index (AWMi), percentage myocardial dysfunction (%MD), and number of wall motion abnormalities. All patients in class 4 (high pulmonary capillary wedge pressure and low cardiac index had > or = 60% MD. With univariate analysis, hemodynamic class correlated with ESAi, AWMi, %MD, the number of wall motion abnormalities, and two clinical variables (number of infarctions and use of diuretic agents). By stepwise linear regression, only AWMi and the number of infarctions were independently predictive of hemodynamic status.

Aged↗

Effect of beta-adrenergic receptor blockade on the physiologic response to dobutamine stress echocardiography.

Dobutamine is an effective pharmacologic stress agent because of its beta-adrenergic receptor agonist properties. Theoretically, concurrent beta-adrenergic receptor blockade might alter this effectiveness, but clinical experience has been variable. Before assessing the relative effectiveness and implications of dobutamine stress echocardiography (DSE) to detect myocardial ischemia in the presence of beta-blockade the physiologic and hemodynamic effects of dobutamine with simultaneous beta-blockade must be understood in a controlled setting. Therefore the purpose of this study was to determine if beta-blocking agents alter the timing and magnitude of the physiologic response to graded doses of dobutamine during a standard DSE. Paired DSEs were performed in seven instrumented open-chest dogs with and without beta-blockade (esmolol 500 micrograms/kg initial bolus and 100 micrograms/kg/min infusion). Heart rate, systolic pressure, proximal left anterior descending coronary artery flow, myocardial thickening, and percentage left ventricular area change (% AC) were monitored. The data for each parameter were fit to linear or exponential functions. With graded doses of dobutamine, the rate of increase in coronary flow was greater than that in %AC, which in turn was greater than that in heart rate (p < 0.05).(ABSTRACT TRUNCATED AT 250 WORDS)

Adrenergic beta-Antagonists↗

Improvement of transthoracic pulmonary venous flow Doppler signal with intravenous injection of sonicated albumin.

OBJECTIVES: This study was performed to determine whether intravenous injection of a sonicated albumin echocardiographic contrast agent (Albunex) improved the quality of the transthoracic pulmonary venous flow Doppler signal. BACKGROUND: Previous studies have shown that transesophageal echocardiography provides pulmonary venous flow Doppler signals superior in quality to those seen with transthoracic echocardiography, which are of limited quality in up to 25% of patients. METHODS: Twenty-one patients underwent transthoracic pulsed wave Doppler examination of pulmonary venous flow before, during and after two doses of Albunex ranging from 0.08 ml/kg (low dose) to 0.22 ml/kg (high dose). In addition, five patients underwent transesophageal examination of pulmonary venous flow before and after a 0.08-ml/kg dose of Albunex. The efficacy of the contrast injection was determined using a score that graded the quality of the three components of the pulmonary venous Doppler signal from 0 to 3 (0 = no visible signal; 3 = optimal signal). RESULTS: Albunex enhanced the quality of the pulmonary venous Doppler signal from baseline (score 3.9 +/- 1.8 [mean +/- SD]) and at both low (score 5.1 +/- 2.2, p < 0.05) and high doses (score 5.6 +/- 2, p < 0.001). Transthoracic pulmonary venous flow velocities were increased, and peak flow velocity ratios were unchanged, after injection of contrast agent. The contrast-enhanced variables showed good agreement with transesophageal flow velocities. CONCLUSIONS: Albunex improves the quality of the transthoracic pulmonary venous Doppler signal, thus allowing improved accuracy of measurement. This approach appears to be effective for increasing the quality of data obtained from the transthoracic examination.

Adult↗

Spatial and temporal variability in the pattern of recovery of ventricular geometry and function after acute occlusion and reperfusion.

Myocardial ischemia and infarction are known to cause changes in both ventricular shape and function. Little is known about the recovery of ventricular geometry after transient myocardial ischemia and its relationship to recovery of function. To examine the pattern of recovery of ventricular geometry following transient coronary artery occlusion and to assess the relationship of this to the return of systolic function, we used echocardiography to study 13 dogs following 15-minute occlusion of the left anterior descending coronary artery. During ischemia, total endocardial surface area (ESA) increased from 32.55 +/- 1.77 to 45.36 +/- 3.18 cm2 (p = 0.001). The most striking increase was at the apex, where circumference increased from 5.04 +/- 0.24 at baseline to 7.86 +/- 0.43 cm at the end of occlusion (p = 0.0001), an increase of 58%. During reperfusion, ventricular geometry rapidly returned toward normal (baseline), with recovery of 80% of the increase in ESA evident by 15 minutes of reperfusion. Recovery of systolic function was substantially slower (p < 0.005 for all periods of observation during the 2 hours of reperfusion). During reperfusion, recovery of ventricular geometry and function was not uniform throughout the ischemic bed. The apex recovered most slowly, with the centroid of the area of abnormal contraction progressively moving along the long axis of the left ventricle toward the apex. There was also a progressive decrease in the radius of the area of dysfunction, from 2.0 +/- 0.15 at end occlusion to 0.13 +/- 0.07 cm at 120 minutes of reperfusion (p = 0.0001). There was no difference in blood flow between the apical and anterior segments during ischemia or reperfusion. Reperfusion favorably reduced the ischemic zone dilation before recovery of active systolic function and geometric recovery thus may be important in determining ultimate functional recovery. In addition, recovery of function proceeded inward towards the center of the ischemic territory and in a wavefront from the base to apex. This heterogeneous and asymmetric recovery suggests that sampling at one point within the ischemic zone may not reflect the true temporal pattern of recovery.

Acute Disease↗

Right ventricular dysfunction: an independent predictor of adverse outcome in patients with myocarditis.

To assess the predictive value of right ventricular systolic function in patients with active myocarditis, the echocardiograms of 23 patients with biopsy-confirmed myocarditis were reviewed. Right ventricular systolic function was evaluated qualitatively and quantitatively by descent of the right ventricular base. Patients were divided into those with normal right ventricular function, in whom right ventricular descent was 1.9 +/- 0.1 cm, and those with abnormal right ventricular function, in whom right ventricular descent was 0.8 +/- 0.1 cm (p < 0.001). There were no differences between the two groups in age, duration of symptoms, baseline hemodynamics, or histologic assessment. Initial left ventricular ejection fraction was significantly lower in patients with depressed right ventricular function (27.5 +/- 4.9%) compared with that in patients with normal right ventricular function (47.5 +/- 6.3%) (p = 0.01). The likelihood of an adverse outcome, defined as death or need for cardiac transplantation, was greater in patients with abnormal right ventricular function (right ventricular descent < or = 1.7 cm) than in patients with normal right ventricular function (right ventricular descent > 1.7 cm) (p < 0.03). Multivariate analysis revealed that right ventricular dysfunction as quantified by right ventricular descent was the most powerful predictor of adverse outcome.

Female↗