Significance of precordial T-wave increase during treadmill stress testing.

It appears that a T-wave amplitude increase of > or = 2.5 mm in lead V2 during a treadmill stress test may be specific (95%), even though this finding only occurs occasionally. Therefore, a T-wave amplitude increase during an exercise test may aid in the diagnosis of the few patients who develop this abnormality, especially if there is no ST depression, as has occurred during several recent exercise tests.

Coronary Disease↗

Diagnostic accuracy of predicting coronary artery disease related to patients' characteristics.

Patients' demographic and clinical characteristics may affect diagnostic accuracy of cardiologists. We asked a group of experienced cardiologists from three institutions to estimate the pretest probability of coronary artery disease in 257 patients referred for diagnostic coronary angiography and with no history of previous myocardial infarction nor valvular heart disease. Physicians pretest estimates were compared with the diagnostic findings of coronary angiography. We tested the influence of five variables on the accuracy of the pretest estimates: age, sex, chest pain characteristics, rest electrocardiogram and electrocardiographic exercise test result. Cardiologists tended to overestimate the presence of coronary artery disease and this tendency was particularly remarkable in the group of patients showing a negative exercise test. Pretest diagnostic accuracy was 0.72 when the test result was negative and 0.85 when the test result was positive (95% confidence interval of the difference 0.03 to 0.23; p < 0.001). The diagnosis of coronary artery disease was also more accurate for male than for female patients (0.81 vs 0.70; 95% confidence interval of the difference 0.02 to 0.21; p < 0.02). Characteristics of chest pain, age and rest electrocardiogram did not affect the level of pretest diagnostic accuracy. Cardiologists should be cognizant of correctly interpreting a negative exercise test and the clinical data of female patients; in both cases, they should move circumspect of the diagnosis of coronary artery disease.

Age Factors↗

A basic approach to the interpretation of the exercise test.

For primary care physicians, exercise testing is a cost-effective tool to evaluate patients presenting with symptoms. It helps to stratify those with probable coronary artery disease into a high-risk group needing referral and a low-risk group that can be observed. Each of the five main responses--the presence of myocardial ischemia, the heart rate and blood pressure response, the symptoms, any dysrhythmias, and the maximal aerobic capacity--should be mentioned in the final report. A suggested format for the exercise test report is shown in Table 4. Using the tools of pretest and post-test probability, the severity of disease, and the exercise treadmill scores greatly aids the primary care physician in the management of the patient evaluated with an exercise test.

Aerobiosis↗

Exercise testing in special situations.

This article discusses exercise testing in valvular heart disease, hypertension, and the evaluation of patients for surgery. It also provides information on the effects of drugs on the exercise test and the clinical significance of block patterns and arrhythmias encountered during exercise.

Arrhythmias, Cardiac↗

Analysis of the signal-averaged P-wave duration in patients with percutaneous coronary angioplasty-induced myocardial ischemia.

To assess the impact of angioplasty-induced myocardial ischemia on the duration of the surface P wave, patients undergoing elective angioplasty of isolated lesion in the left anterior descending, circumflex or right coronary arteries were monitored with a 3-channel electrocardiographic Holter system. The leads used were modified bipolar chest leads V5, aVF and V2 (CM-V5, CS-aVF and CM-V2). After echocardiographic signal-averaging, the earliest onset and the latest offset of the P wave were identified in all of the above time-aligned signal-averaged leads, and the composite maximal P duration was measured under 10 x magnification. The maximal ST-segment shift during balloon inflation was also measured in all of the above leads at 60 ms after the J point. In the study group comprising 47 patients, the mean signal-averaged P-wave duration was 125.0 +/- 16 ms at baseline versus 130.0 +/- 15 ms during balloon inflation, p less than 0.005. In the left anterior descending coronary artery group (n = 23), the mean signal-averaged P-wave duration was 122.4 +/- 17 ms and 131.3 +/- 16 ms during balloon inflation, p less than 0.005). In the group with a right coronary artery lesion (n = 18), the values were 127.3 +/- 14 ms and 128.4 +/- 13 ms respectively (p = not significant). Significant increases in the P-wave duration were found to occur in groups both with (n = 34) and without (n = 13) ST-segment shift greater than or equal to 1 mm (both p less than 0.05).(ABSTRACT TRUNCATED AT 250 WORDS)

Algorithms↗

Efficacy of three-channel ambulatory electrocardiographic monitoring for the detection of myocardial ischemia.

The recognition of silent myocardial ischemia (SMI) has been demonstrated to have important clinical relevance. Two-channel ambulatory (Holter) electrocardiographic recording is a commonly utilized method for detecting transient electrocardiographic ST segment changes representative of SMI. It has been suggested that the analysis of two channels alone may not adequately detect SMI. We therefore evaluated the diagnostic yield of three channels using a three-channel electrocardiographic monitoring device in 46 consecutive patients (age 61 +/- 9 years) undergoing percutaneous transluminal coronary angioplasty of an isolated single-vessel stenosis. Modified bipolar chest leads V2, V5, and AVF (CM-V2, CM-V5, and CS-AVF) were utilized for analysis. The percent detection of ST segment changes from various combinations of two-lead recordings were compared to the total three leads, and an absolute transient ST segment shift (STSS) of greater than or equal to 1 mm during balloon inflation was considered as evidence of myocardial ischemia. One patient was excluded because of the need for ventricular pacing during balloon inflation. A total of 33 of 45 patients had STSS in all three leads (percent detection = 73%), while 32 (71%) had STSS in the two-lead grouping with the highest diagnostic yield (CM-V2/CM-V5; p = ns). Of the various two-lead combinations studied, leads CM-V2 and CM-V5 provided the best lead set overall for the detection of ischemic STSS. Three-channel ambulatory electrocardiographic recording only marginally improves upon the detection of ischemia when compared with standard (CM-V2/CM-V5 or CM-V5/CS-AVF) two-channel ambulatory electrocardiographic recordings.

Angioplasty, Balloon, Coronary↗

The predictive value of the time course of ST segment depression during exercise testing in patients referred for coronary angiograms.

We studied the time course of ST segment depression during and after exercise testing in 462 subjects who also had coronary angiograms. Sixty-three percent of patients with late onset-early offset ST depression, previously reported to be likely to have false positive tests, had significant coronary artery disease, and 32% had three-vessel disease. Those with early onset and late offset ST depression and those with resting ST depression that was accentuated with exercise had a high prevalence of significant coronary artery disease and three-vessel disease. We found that observation of the time course of ST depression during and after exercise adds significantly to the information gained during exercise testing.

Aged↗

Computer probability estimates of angiographic coronary artery disease: transportability and comparison with cardiologists' estimates.

A computer algorithm for estimating probabilities of any significant coronary obstruction and triple vessel/left main obstructions was derived, validated, and compared with the assessments of cardiac clinician angiographers. The algorithm performed at least as well as the clinicians when the latter knew the identity of the patients whose angiograms they had decided to perform. The clinicians were more accurate when they did not know the identity of the subjects but worked from tabulated objective data. Referral and value induced bias may affect physician judgment in assessing disease probability. Application of computer aids or consultation with cardiologists not directly involved with patient management may assist in more rational assessments and decision making.

Adult↗

The significance of lead strength on ST changes during treadmill stress tests.

The contribution of relative lead strengths to ST depression during exercise was evaluated in 334 patients who had both a treadmill stress test and an angiogram. Patients were referred for exercise testing for the evaluation of suspected or known coronary artery disease. This was accomplished by comparing the magnitude of ST-segment depression to a constructed ST/R ratio. Using a cutoff of 0.1 for the ST/R ratio, the data were compared to the sensitivity and specificity of the 1 mm criteria for ST depression. There was only a slight increase in sensitivity (59% vs 63%) and specificity (60% vs 78%) for the ST/R ratio in comparison to the standard ST depression. However, when these two criteria were reevaluated for patients with less than or equal to 10.0 mm of R wave amplitude, the 0.1 ST/R ratio had a small decrease in specificity (94% vs 80%) when compared to 1 mm of ST depression and a marked increase in sensitivity with 31% for the standard ST depression and 82% using the ST/R ratio. In those with an R wave greater than 20 mm, 1 mm of ST depression was much more sensitive than the ST/HR ratio (95% vs 59%), but the ratio was more specific than the conventional ST depression (78% vs 59%). It is concluded that ST depression should be corrected for R wave amplitude in patients with R waves less than 10 mm and over 20 mm.

Coronary Angiography↗

Significance of signal-averaged P-wave changes during exercise in patients with coronary artery disease and correlation with angiographic findings.

The maximal P-wave duration in all time-aligned leads, and the maximal P-wave amplitude in leads V5 and V6 were measured on a 12-lead, signal-averaged electrocardiogram during the recovery period of an exercise stress test (EST). The study group consisted of 75 patients with coronary artery disease (CAD) documented by greater than or equal to 50% diameter stenosis in 1 or more arteries and a control group of 47 subjects, 15 of them young volunteers and 32 with no or minimal coronary atherosclerosis and normal left ventricular function. All subjects underwent a symptom limited EST, with use of the Ellestad protocol. Signal-averaged P waves recorded before exercise, and for the first 6 minutes in recovery were measured using a 5x magnifier. The mean P duration before exercise in the control group was 107 +/- 16 ms (+/- 1 standard deviation) and 111 +/- 15 ms at the third minute of recovery, (p less than 0.001). In patients with CAD it was 112 +/- 12 and 129 +/- 19 ms (+/- 1 standard deviation), p less than 0.001, respectively. Differences in P-wave duration were found to be statistically significant (p less than 0.001) throughout recovery in the group with CAD when compared with control and maximal values at the third minute. The increase in P-wave duration (greater than or equal to 20 ms) was used as an additional parameter to exercise-induced ST-segment depression, ST elevation, or anginal pain for the test interpretation. The sensitivity increased from 57 to 75% and the specificity decreased from 85 to 77%.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Dacron-woven pacemaker pouch. Influence on long-term pacemaker mobility.

Pacemaker migration can interfere with correct pacing system function and patient comfort. A Dacron pouch has been developed which may prevent these problems. To assess the efficacy of the pouch, we measured various factors of pacemaker mobility in 100 patients after long-term follow-up. The patients were divided into three groups on the basis of their dictated operative reports: group 1, no pouch or anchoring stitch; group 2, pouch only; group 3, anchoring stitch to pacemaker header or pouch. The average age of the study population was 74.3 +/- 11 years. Total follow-up time was 42 +/- 28 months (group I, 53 +/- 32 months; group 2, 36 +/- 23 months; group 3, 34 +/- 25 months). There were no significant differences when pacemakers were measured for movement in the inferosuperior and lateromedial directions, nor was there any difference in the distance between the incision scar and the pacemaker header in any group. There was a significant difference between group 1 and groups 2 and 3 when the degree of tilt of the pacemaker off the chest wall was compared. This was 46 degrees +/- 34 degrees for group 1 and 27 degrees +/- 26 degrees and 26 degrees +/- 27 degrees for groups 2 and 3, respectively (p less than 0.02 for both). These data suggest that the Dacron pouch does not restrict pacemaker mobility parallel to the chest wall during long-term follow-up but does reduce the angle to which the pacemaker can be tilted relative to the chest wall.

Aged↗

Impaired activity rate responsiveness of an atrial activity-triggered pacemaker: the role of differential atrial sensing in its prevention.

The physiological benefit of rate responsive, single-chamber cardiac pacing is well documented. We studied the activity response of nine atrially placed Activitrax II pacemakers. Seven patients were noted to have an inadequate activity-rate response with maximal pacing rates of 85 to 101 beats/min. Marker Channel analysis revealed that the upper rate timeout was reset by far-field R wave sensing, even when sensing occurred in the atrial refractory period. These 9 pacemakers were tested by atrial sensitivity adjustment for ability to exclude far-field R wave sensing, while preserving P wave sensing. Unipolar implantation data were then examined for predictors of this differential far-R and P-wave sensing. Differential atrial sensing occurred in 4/9 pacemakers (2/2 bipolar in the right atrial appendage; 0/1 bipolar in the coronary sinus; and 4/9 unipolar). An empirically developed index utilizing unipolar implant parameters discriminated outcomes for 8/9 unipolar pacemakers. We conclude that: (1) the rate responsiveness of the atrial Activitrax II pacemaker is limited by far-field R wave sensing even when this occurs during atrial channel refractoriness; (2) reprogramming atrial sensitivity to differentially sensed P and far-field R waves may restore appropriate rate responsiveness; and (3) although a unipolar implant discriminant index may correctly identify adequacy of future rate responsiveness, the atrial application of the Activitrax II pacemaker is cautioned until further validation is forthcoming, particularly when used in unipolar and coronary sinus applications.

Adult↗

Iliac vein approach to permanent pacemaker implantation.

Since July 1980, 90 patients have had 95 permanent pacemakers implanted via an iliac vein approach. An incision is made superior to the inguinal ligament and the iliac vein is cannulated with a single lead for the ventricle or two leads for the atrium and ventricle. The pulse generator is placed in the subcutaneous tissue of the abdomen lateral to the umbilicus via a second incision. Overall 28 pacemaker implants were for atrial pacing, 53 for ventricular pacing and 14 were dual chamber. Nine (21%) of the atrial leads displaced and required repositioning and 5 (7%) of the ventricular leads dislodged and required revision. Lead dislodgement, especially in the atrium, remains a major weakness of the approach, and decreases its utility. Eleven percent of the last 19 atrial leads have dislodged. Nevertheless, the method is simple to perform and is presented as an alternative to the usual pectoral implantation site.

Follow-Up Studies↗

Experiences with atrial pacing.

The records of 187 patients with permanent atrial pacemakers implanted between 1970 and 1980 were studied retrospectively to define the indications, outcome and short- and long-term complications of single-chamber atrial pacing. Pacemakers were implanted in 145 (77%) patients with tachybrady syndrome, 35 (19%) with sinus bradycardia and 7 (4%) with ventricular arrhythmia. Intact atrioventricular (AV) conduction was defined as absence of second- or third-degree heart block with incremental atrial pacing to a heart rate of 120 beats/min before implantation. The average follow-up was 30 months, including 87 patients (46%) who were followed an average of 48 months. Four patients developed significant conduction disease requiring placement of a ventricular lead. Complications included 4 lead fractures (all coronary sinus leads), 10 dislodgments (9 coronary sinus, 1 tined atrial "J") and 6 threshold rises requiring repositioning of the lead. Eight dislodgments occurred within an average of 5.6 days. The average increase in threshold that required repositioning occurred at 14 days. The average lead fracture occurred at 25 months. Atrial pacing is safe and effective for patients with sinoatrial node disorder (sick sinus syndrome) and intact AV conduction. Progression to clinically significant AV block is uncommon. Complications occur early with coronary sinus leads and are less common with newer leads.

Aged↗

Autonomic responses in chest pain syndromes as compared to normal subjects.

The heart rate response to standing, cough, hand grip, and deep breathing were examined in normal subjects and coronary artery disease patients (greater than 70% diameter narrowing). The heart rate responses to these maneuvers were reduced in coronary patients and in anginal patients with normal coronary angiograms, as compared to normals. Detection (with the heart rate response to standing) was determined by using an RR interval cutoff of 140 ms for males and 120 ms for females discriminated between normals and CAD patients. In men sensitivity was 0.58, specificity 0.87 and CCR 0.75, and in women sensitivity was 0.67, specificity 0.79 and CCR 0.75. These values are similar to those reported for ST segment depression in similar populations. When separating normals from those with 2 and 3 vessel disease--sensitivity is 0.67, specificity 0.87, predictive value 0.71 and CCR 0.80. The response to cough, hand grip, and deep breathing showed similar trends but had less specificity than the response to standing. Thus, the heart rate response to most autonomic maneuvers is blunted in subjects with coronary disease and in those with pain syndromes sent for coronary angiography. These findings need testing in larger populations but autonomic maneuvers fail to discriminate patients with coronary disease from those with normal angiograms presenting with chest pain syndromes.

Adult↗