Search PubMed⌕ Search

Biomedical subjects

M H Du

Publications and source records attributed to M H Du.

4 recordsLinked to original sources

The recognition of three different epitopes for the H-type 2 human blood group determinant by lectins of Ulex europaeus, Galactia tenuiflora and Psophocarpus tetragonolobus (winged bean).

The chemical mapping of the regions of H-type 2 human blood group-related trisaccharide (Fuc alpha (1-2)Gal beta (1-4)GlcNAc beta Me) that are recognized by three different lectins, the so-called epitopes, are reviewed together with an account of how and why oligosaccharides form specific complexes with proteins as presently viewed in this laboratory. The occasion is used to report the synthesis of the various mono-O-methyl derivatives of the above trisaccharide that were used in these investigations. Also, Fuc alpha (1-2)Gal beta (1-4)Xyl beta Me was synthesized in order to examine whether or not the hydroxymethyl group of the GlcNAc residue participates in the binding reaction.

ABO Blood-Group System↗

Measurement of human BAERs by the maximum length sequence technique.

The traditional brainstem auditory evoked response (BAER) measurement technique (ensemble averaging) is time-consuming and is not acceptable for some time-critical clinical applications. In the paper the application of a pseudorandom binary sequence, the maximum length sequence, to human BAER measurements is examined. This technique permits a faster click rate to stimulate the test subject, and obtains a higher signal-to-noise ratio (SNR) response through deconvolution. When compared with conventional averaging, the method can result in an improved SNR or in faster measurement of BAER. The theory of the technique and the experimental setup are presented, and theoretical analysis on the SNR improvement by this technique against averaging is also given. Actual measurements of BAER on both humans and cats indicate that this technique is effective, especially when the measurement time is not too long, or the number of trials is not too large.

Algorithms↗

Visual evoked potential measurement by maximum length sequence technique.

The maximum length sequence (MLS) technique is applied to improve data collection of a clinically important long latency visual potential. Given a limited time for measuring the response and with low number of stimulus presentation, the MLS technique exceeded the conventional method of ensemble averaging in attaining a higher signal-to-noise ratio (SNR). The theoretical consideration of such improvement is developed along with the system implementation. Typical examples of the results obtained in a human subject are presented.

Algorithms↗