Non-invasive measurement of pulmonary arterial pressure: I. A haemodynamic modelling approach.

In order to monitor pulmonary arterial pressure (P) by any non-invasive imaging technique, a haemodynamic model of blood flow kinetics and wall mechanics has been developed. It is a one-dimensional model of pulsatile flow in an elastic pulmonary arterial trunk, assuming that blood is an incompressible fluid and viscous effects are negligible. The equations are P(t)-Pd = rho c2lnS(t)/Sd-1/2pw-2(t) Pd = (Sd/Ss)1/2Pp where, at any time of the ejection phase of systole, P(t), S(t) and w(t) are the pulmonary arterial pressure, cross-sectional area of the pulmonary artery and blood velocity averaged on the cross section S, respectively, PP is the pulse pressure, the difference between the peak systolic pressure and the diastolic pressure Pd; rho is blood density, c pulse wave velocity, and Ss and Sd are maximum (systolic) and minimum (diastolic) values of the cross-sectional area S. Using these equations, P(t) can be calculated if the three parameters, i.e. c, S(t) and w(t) are measured. So far, it has been impossible to measure the pulse wave velocity c non-invasively. We have investigated the calculation of c from S(t) and w(t) using the equation of continuity in the absence and presence of reflected pressure waves. The hypotheses of the haemodynamic model are discussed.

Blood Flow Velocity↗

Non-invasive measurement of pulmonary arterial pressure: II. A radionuclide method.

Pulmonary artery pulse pressure (PP) and diastolic pressure (Pd) may be obtained by applying a haemodynamic model of blood flow kinetics and wall mechanics to the pulmonary artery: Pp = rho(ws/(Ss/Sd-1))2log(Ss/Sd)-1/2 rho w2s Pd = (Sd/Ss)1/2Pp where rho is blood density, ws is peak ejection velocity, and Ss and Sd are peak maximal and end diastolic cross-sectional areas of the main pulmonary artery. The different parameters of the equations were measured from radionuclide first pass and equilibrium studies. Radionuclide first pass studies were performed in 24 patients with intravenous injection of 20 mCi of 99Tcm red blood cells with a gamma camera in a 20 degrees right anterior oblique position: data were collected in list mode, i.e. a continuous sequence of spatial and temporal coordinates of each photon. Pulmonary arterial pressure was recorded simultaneously with a microtip catheter during the first pass study. Gated first pass images of the right side of the heart were reconstructed, regions of interest drawn over the right ventricle and the main pulmonary artery (MPA) and time-activity curves generated. Peak systolic (Cs) and end diastolic (Cd) counts obtained from the MPA curve were proportional to the cross sections Ss and Sd of the MPA and Ss/Sd = Cs/Cd. The diameter (D) of the pulmonary artery was calculated as the distance between the two zeros of the second derivative of a cross-sectional profile. The averaged cross-sectional area was S = pi D2/4. ECG gated blood pool studies were performed in a LAO 40 degrees position when the tracer was at equilibrium; they were processed automatically and the right ventricular end diastolic counts (EDC) converted into volume (EDV) using an aortic volume/count ratio. Right ventricular peak ejection rate (PER) was obtained from the RV time-activity curve and the instantaneous peak ejection velocity was calculated, ws = PER X EDV/S X EDC. PP and Pd were calculated in mmHg and the radionuclide method yielded pressure values that correlated reasonably with catheterisation values: PP(rad) = 0.99 PP(cath)-0.55, r = 0.84 and Pd(rad) = 0.67 Pd(cath) + 4.91, r = 0.74. We conclude that radionuclide techniques can provide a non-invasive method based on a haemodynamic model for measuring pulmonary arterial pressure.

Adult↗

Accuracy of gated equilibrium radioventriculography in measuring left ventricular function in dogs.

To assess the precision of gated equilibrium radioventriculography in measuring changes in left ventricular stroke volume (LVSV), we studied five dogs each with a chronically implanted electromagnetic flowmeter on the ascending aorta. Per cent changes in left ventricular stroke counts (LVSC) were compared to those in LVSV following acute changes induced by positive end respiratory pressure. We have compared LVSCs calculated in five different ways: (1) Manual outlining of LV region of interest (LVROI), either single fixed enddiastolic (ED) ROI or ED and endsystolic (ES) ROIs with the aid of functional images (first harmonic of Fourier analysis); (2-5) automatic outlining of LV ROI (the algorithm generated 30 profiles on which the maximum of second derivative delineated the LV edges) was performed either on ED image or both ED and ES images. For these four methods a crescent-shaped ROI for background correction was manually drawn at the border of the LV ROI. The fifth method used an automatically drawn single fixed LVED ROI with interpolative background substraction (IBS) between LV and RV edges. LVSC changes, calculated with the IBS method correlated better with LVSV changes than the other four methods. Thus assessment of small LVSC changes is highly processing-dependent.

Animals↗

Evaluation of 3 dimensional space and time filtering on ECG gated 201Tl myocardial images.

Stress 201Tl myocardial images were obtained using a standard ECG gated acquisition protocol for 10 min per view. These images were filtered using a three dimensional space and time filter. The effects of filtering were evaluated by sectorial analysis. Comparing raw and filtered dynamic images, quantification demonstrated that filtering did not produce artefacts. A conventional static image was also obtained as the sum of the series of unfiltered dynamic images. Comparison of raw static and filtered diastolic images indicated that the latter demonstrated myocardial abnormalities more clearly (P less than 0.01) in 33 patients. Improvement in the signal to noise ratio produced by filtering made cinematic display and visual analysis possible which was not feasible with raw gated images. Clinical evaluation is in progress.

Diastole↗

Quantification of left to right cardiac shunts by multiple deconvolution analysis.

A new method for quantification of left to right cardiac shunts was studied in 17 patients scheduled for cardiac catheterization who had also undergone radionuclide angiocardiography. The observed pulmonary transit curve was deconvoluted in two different ways: (1) by the superior vena caval ("bolus") time-activity curve, to yield the deconvoluted pulmonary transit curve, which represented the theoretical pulmonary transit curve with a perfect bolus injection, and (2) by the right ventricular time-activity curve, to yield the pulmonary transfer function, which represented the theoretical pulmonary transit curve with a perfect bolus injection an with no intracardiac shunts. The pulmonary transfer function was superimposed on the deconvoluted pulmonary transit curve, and the area A under it obtained. The pulmonary transfer function was then subtracted from the deconvoluted pulmonary transit curve. The pulmonary transfer function was scaled to fit the resulting shunt recirculation peak in the difference curve, and the area B under this scaled pulmonary transfer function obtained. Shunt size was quantified as the pulmonary (QP) to systemic (QS) flow ration QP/QS = A/(A-B). The method correlated closely with oximetry (r = 0.93). Use of this multiple deconvolution analysis technique provides accurate shunt quantification and reduces subjective operator decisions.