Search PubMed⌕ Search

Biomedical subjects

M Grass

Publications and source records attributed to M Grass.

At least 19 recordsLinked to original sources

An X-ray-based method for the determination of the contrast agent propagation in 3-D vessel structures.

A method for the determination of the contrast-agent propagation in vessel trees is presented. A standard three-dimensional (3-D) rotational angiography procedure is performed to reconstruct the morphology of the contrast-filled vessel tree in a 3-D volume. An additional fluoroscopy projection series acquired with a fixed projection angle delivers the temporal information of the bolus propagating. The mapping of the propagation information from the two-dimensional projections to the 3-D image data set is the topic of this paper. A symbolic tree structure is built up that represents the vessel tree including bifurcations. Neighborhood relations between vessel pieces are given in three dimensions. This facilitates filtering procedures and plausibility controls of the resulting time dependent 3-D data set. The presented method proved to be accurate with phantom data and gives novel insight in the feeding structure of arterio-venous malformations and aneurysms.

Algorithms↗

Artifact analysis of approximate helical cone-beam CT reconstruction algorithms.

In this paper, four approximate cone-beam CT reconstruction algorithms are compared: Advanced single slice rebinning (ASSR) as a representative of algorithms employing a two dimensional approximation, PI, PI-SLANT, and 3-PI which all use a proper three dimensional back-projection. A detailed analysis of the image artifacts produced by these techniques shows that aliasing in the z-direction is the predominant source of artifacts for a 16-row scanner with 1.25 mm nominal slice thickness. For a detector with isotropic resolution of 0.5 mm, we found that ASSR and PI produce different kinds of artifacts which are almost at the same level, while PI-SLANT produces none of these artifacts. It is shown that the use of redundant data in the 3-PI method suppresses aliasing artifacts efficiently for both scanners.

Algorithms↗

Angular weighted hybrid cone-beam CT reconstruction for circular trajectories.

Hybrid reconstruction techniques have been introduced for the volume reconstruction of axially truncated cone-beam computed tomography projection data acquired along a circular source-detector trajectory. The introduction of weighted half-scan techniques into this framework is described in this paper. Due to the cone-beam geometry it is not possible to perform the weighting on the projections as is typically done in conventional single-line computed tomography. Hence, in this paper we present an efficient way to incorporate angular weighting functions, depending on the object point position, into the framework of hybrid cone-beam reconstruction. Four different angular weighting functions are introduced and discussed with respect to their cone-beam artefact behaviour and their influence on the signal-to-noise ratio. As a result, the most effective angular weighting function for hybrid circular cone-beam reconstruction is determined by means of a simulation study based on mathematical phantoms and clinical data sets. This distance-weighted angular weighting scheme yields the best results in terms of high image quality, low computational complexity and signal-to-noise variations in the reconstruction volume.

Computer Simulation↗

A fast and efficient method for sequential cone-beam tomography.

Sequential cone-beam tomography is a method that uses data of two or more parallel circular trajectories of a cone-beam scanner to reconstruct the object function. We propose a condition for the data acquisition that ensures that all object points between two successive circles are irradiated over an angular span of the x-ray source position of exactly 360 degrees in total as seen along the rotation axis. A fast and efficient approximative reconstruction method for the proposed acquisition is presented which uses data from exactly 360 degrees for every object point. It is based on the Tent-FDK method which was recently developed for single circular cone-beam CT. The measurement geometry does not provide sufficient data for exact reconstruction but it is shown that the proposed reconstruction method provides satisfying image quality for small cone angles.

Algorithms↗

3D cone-beam CT reconstruction for circular trajectories.

3D reconstruction from 2D projections obtained along a single circular source trajectory is most commonly done using an algorithm due to Feldkamp, Davis and Kress. In this paper we propose an alternative approach based on a cone-beam to parallel-beam rebinning step, a corresponding rebinning step into a rectangular virtual detector plane and a filtered backprojection. This approach yields an improved image quality reflected by a decreased low-intensity drop which is well known for 3D reconstruction from projection data obtained along circular trajectories. At the same time the computational complexity is lower than in Feldkamp's original approach. Based on this idea, a hybrid 3D cone-beam reconstruction method is formulated that enlarges the reconstruction volume in its dimension along the rotation axis of the cone-beam CT system. This enlargement is achieved by applying different reconstruction conditions for each voxel. An optimal ratio between the reconstructible and irradiated volume of the scanned object is achieved.

Algorithms↗

The n-PI-method for helical cone-beam CT.

A new class of acquisition schemes for helical cone-beam computed tomography (CB-CT) scanning is introduced, and their effect on the reconstruction methods is analyzed. These acquisition schemes are based on a new detector shape that is bounded by the helix. It will be shown that the data acquired with these schemes are compatible with exact reconstruction methods, and the adaptation of exact reconstruction algorithms to the new acquisition geometry is described. At the same time, the so-called PI-sufficiency condition is fulfilled. Moreover, a good fit to the acquisition requirements of the various medical applications of cone-beam CT is achieved. In contrast to other helical cone-beam acquisition and reconstruction methods, the n-PI-method introduced in this publication allows for variable pitches of the acquisition helix. This additional feature will introduce a higher flexibility into the acquisition protocols of future medical cone-beam scanners. An approximative n-PI-filtered backprojection (n-PI-FBP) reconstruction method is presented and verified. It yields convincing image quality.

Image Processing, Computer-Assisted↗

[Angiosarcoma of the right atrium: local control via low radiation doses and razoxane. A case report].

BACKGROUND: Angiosarcomas of the heart are rare neoplasms bearing an unfavorable prognosis. In recent series, the median survival is about 5 months. The response to radiation therapy is uncertain. CASE REPORT: A 65-year-old copper smith with an angiosarcoma of the right atrium and metastases of the liver received a partial resection of the primary tumor in January 1992. This was followed by a polychemotherapy including ifosfamide, epirubicin and dacarbacin (DTIC). In April 1992, after 5 cycles of this treatment a large regrowth of the primary and multiple pulmonary metastases were observed. After a 4-day pretreatment with the radiosensitizer razoxane, the large tumor of the right heart was irradiated with 25 MV photons of a linear accelerator. Single doses of 200 cGy were given via parallel opposed fields. The total radiation dose at the tumor was 30 Gy. Concomitantly, razoxane was given at a dose of 125 mg twice daily during the radiation days until the end of the radiotherapy. The treatment was well tolerated and the patient went into a subtotal remission. Chest X-rays from September 1992 revealed a progression of the metastases in the lung and the liver, the recurrent tumor of the right atrium remained in a subtotal remission. The patient was retreated with ifosfamide, epirubicin and DTIC. No substantial remission of the metastases occurred and the patient died at the end of January 1993. At autopsy, the recurrent primary and the lung metastases within the region of the former radiation field remained locally controlled. CONCLUSION: Reviewing the literature and considering this case, irradiation seems to be a valid treatment option for the local control of cardiac angiosarcomas. The combination of radiotherapy with razoxane eventually allows a considerable reduction of the radiation dose.

Aged↗

Loss of heterozygosity of BRCA1, TP53 and TCRD markers analysed in sporadic endometrial cancer.

Genetic alterations of tumour suppressor genes, for which loss of heterozygosity (LOH) is one mechanism of gene inactivation, are important steps in the development of endometrial cancer. To investigate the clinical relevance of LOH of BRCA1 (17q21), TP53 (17p13) and TCRD (14q11) in endometrial cancer, polymerase chain reaction (PCR)-based fluorescent DNA technology for the detection of microsatellite polymorphisms was applied. One hundred and thirteen archival endometrial cancer samples with matched normal tissues were examined. Allele loss at three loci were correlated with age, tumour size, lymph node status, metastases, stage, histological types, grade, expression of oestrogen receptor (ER) and progesterone receptor (PgR), family history of cancer, previous history of cancer or precursor lesions, and previous history of hormone replacement therapy (HRT). LOH for BRCA1 was detected in 18.1%, of TP53 in 26.9%, and of TCRD in 26.3% of informative cases. LOH of BRCA1 correlated with medium grade, positive ER status, and family history of cancer; LOH of TP53 correlated with younger age, high grade, positive PgR status, and with tumours from patients without HRT; LOH of TCRD correlated only with family history of cancer. LOH at all three loci correlated only with grade and positive family history. Allele loss of one of the three tumour suppressor loci did not correlate with disease-free survival (DFS), but LOH of BRCA1 correlated significantly with decreased overall survival (OS). The latter, together with the correlation of LOH of BRCA1 locus with steroid hormone receptor expression, might give a hint to the potential involvement of the co-localised 17 beta-hydroxysteroid dehydrogenase (HSD) gene in the development of endometrial cancer.

Adult↗