Search PubMed⌕ Search

Biomedical subjects

M Goyen

Publications and source records attributed to M Goyen.

At least 19 recordsLinked to original sources

[Whole body MRI--diagnostic strategy of the future?].

Whole body magnetic resonance imaging (MRI) opens new opportunities in diagnostic radiology as systemic disease entities can be examined with high sensitivity. This can lead to a change of paradigm, so that not only organ-related but rather disease-specific MRI examination protocols can be applied which focus on the underlying pathophysiology of the disease. Whole body MRI has already been successfully used for several oncological and non-oncological indications. In addition, whole body MRI has broadened the discussion regarding its use for secondary prevention. Compared to computed tomography, MRI does not use radiation. Although whole body MRI is still in an early stage, the enormous medical and economical potential can be envisioned.

Forecasting↗

Dark lumen MR colonography: can high spatial resolution VIBE imaging improve the detection of colorectal masses?

PURPOSE: To assess whether the detection of colorectal lesions can be improved using high spatial resolution VIBE imaging. MATERIALS AND METHODS: 48 patients underwent same-day dark lumen MR colonography (MRC) and conventional colonoscopy (CC) as the standard for the detection of colorectal masses. MRC was performed using contrast-enhanced standard and high spatial resolution T1-weighted 3D VIBE sequences. The findings and the image quality of the standard and high spatial resolution VIBE sequences were compared qualitatively and quantitatively. The findings of both sequences regarding colorectal lesions were compared to those of a subsequently performed colonoscopy. RESULTS: The high spatial resolution VIBE sequence significantly improved the quantitative image quality (CNR 54.0 vs. 36.8). However, high spatial resolution VIBE imaging did not detect more colorectal lesions than the standard VIBE sequence. In addition, none of the sequences employed was able to detect lesions with a diameter of less than 5 mm (CC 40 lesions). However, 13 colorectal lesions with a diameter of greater than 5 mm were detected by both sequences (CC 15). CONCLUSION: High spatial resolution VIBE imaging did not improve the detection of colorectal masses and MRC fails to detect colorectal lesions with a diameter of less than 5 mm.

Adult↗

Measuring tongue volumes and visualizing the chewing and swallowing process using real-time TrueFISP imaging--initial clinical experience in healthy volunteers and patients with acromegaly.

This study assessed both two-dimensional (2D) TrueFISP imaging for quantifying tongue volume and real-time TrueFISP imaging for evaluating chewing and swallowing in healthy volunteers and patients with acromegaly. In 50 healthy volunteers, tongue volumes were measured using a 2D TrueFISP sequence. Chewing and swallowing were visualized using a real-time TrueFISP sequence. Ten patients with acromegaly were examined twice with the same magnetic resonance imaging protocol: once prior to therapy and a second time 6 months after therapy. Prior to therapy, healthy volunteers had an average tongue volume of 140 ml for men and 90 ml for women, and patients with acromegaly had an average tongue volume of 180 ml for men and 145 ml for women. However, 6 months after therapy the mean tongue volumes in patients with acromegaly had decreased to 154 ml in the men and to 125 ml in the women. The chewing and swallowing process was normal in all volunteers. Prior to therapy, just two patients showed a chewing and swallowing pathology, which disappeared after therapy. Patients with acromegaly had larger tongue volumes than healthy volunteers, and TrueFISP imaging proved feasible for visualizing chewing and swallowing in real time and is capable of detecting possible pathologies. Furthermore, TrueFISP imaging can be used to monitor therapeutic approaches in patients with acromegaly.

Acromegaly↗

[Cardiovascular whole-body MRI: possibilities and limitations in prevention].

Cardiovascular disease is a major challenge to the healthcare with increasing prevalence in western societies. Hence, early detection of cardiovascular pathologies and preventative strategies will experience growing relevance in the future. Magnetic resonance imaging (MRI) nowadays allows a comprehensive analysis of the cardiovascular system. By combining separate examinations of brain, arterial vasculature, and heart the technique permits early detection of pathological changes with high diagnostic accuracy void of adverse events. Such a protocol has been proven feasible and technically robust and can be performed within 45 min. Inherent limitations are low spatial resolution of whole-body MR angiography and lack of functional stress testing of the heart. However, while being suitable as a fast and comprehensive imaging technique for cardiovascular screening purposes, medical consequences and socioeconomic relevance must further be elucidated.

Adult↗

[New techniques in computed tomography. Significance for urology].

Computed tomographic (CT) imaging has become the modality of choice for the assessment of patients with urological malignancies. Recently, multi-slice CT imaging was introduced, providing faster acquisition times and higher resolution leading to improved image quality. Several studies show that thin-slice, high-resolution acquisition strategies lead to an improved accuracy for T-staging, especially of renal cell carcinomas. Three-dimensional post-processing techniques for the visualization of the vascular supply as well as the ureter (CT-angiography and CT-urography) are helpful for surgical planning. Compared to conventional imaging strategies unenhanced CT images render higher sensitivities and specificities for detecting stone disease in patients with acute flank pain. In the USA unenhanced CT imaging has almost replaced conventional urography, as no contrast agent is administered and the examination time is shorter. PET/CT examinations provide information on the morphology and function of tumors in one examination. However, there are only few data available for the assessment of urologic tumors.

Algorithms↗

Gadobenate dimeglumine (MultiHance) for magnetic resonance angiography: review of the literature.

Although limited in number, reports describing the use of Gd-BOPTA for 3D CE-MRA reveal that this agent is safe, well tolerated and effective for CE-MRA at doses up to 0.3 mmol/kg bodyweight. The use of Gd-BOPTA leads to additional diagnostically relevant information comparable to that attainable with conventional DSA and superior to that on non-enhanced MRA in most arterial territories. In studies in which Gd-BOPTA is compared at equal dose with other gadolinium-based MR contrast agents, Gd-BOPTA has consistently shown significantly better quantitative and qualitative performance. Thus, Gd-BOPTA can be considered to have a very favorable risk/benefit ratio for MRA. In summary, it is likely the documented superiority of Gd-BOPTA for MR angiography will lead to its broad usage for this indication wherever the agent becomes available.

Carotid Stenosis↗

[Prevention without radiation--a strategy for comprehensive early detection using magnetic resonance tomography].

Recent advances in hardware technology, noninvasiveness, lack of radiation and high diagnostic accuracy combine to allow the usage of magnetic resonance imaging (MRI) for disease screening in asymptomatic people. 175 volunteers were examined by means of a comprehensive 60-minute MR-screening-protocol covering four organ systems: the brain, the arterial vasculature, the heart and the colon. In 28% of the cases vascular pathology (cerebral, peripheral or cardiovascular) was detected. In up to 17% of the single examination parts relevant incidental findings were seen. The outlined comprehensive MR-protocol is an accurate and patient-friendly imaging tool for the detection of vascular pathology as well as colonic polyps. The socio-economic relevance of this screening exam has to be further investigated in larger patient cohorts.

Adult↗

Recurrent exercise induced subclavian vein thrombosis in a conductor.

We present a case of a young male patient with recurrent subclavian vein thrombosis due to conducting after prior successful thrombolytic therapy. Musculoskeletal problems are common among musicians. A thoracic outlet syndrome associated to a profession induced thrombosis in a musician has not been described before. Surgical removal of the first rip can prevent recurrent thrombotic occlusion of the subclavian vein, but was not performed in this patient. Considering the specific situation of a young musician there is no information whether surgical or conservative treatment is suitable to allow a successful career as an active musician.

Adult↗

Value of transesophageal echocardiography, esophago-gastroduodenoscopy and retinoscopy prior to intra-arterial fibrinolytic therapy in patients with peripheral arterial disease.

BACKGROUND: We prospectively investigated the need for esophagogastroduodenoscopy (EGD), transesophageal echocardiography (TEE) and retinoscopy for pre-interventional screening in patients with peripheral arterial occlusive disease (PAD) prior to intraarterial fibrinolytic therapy. PATIENTS AND METHODS: 212 consecutive patients suffering from PAD (164 male and 48 female, mean age: 64 +/- 11 years, 161 patients stage II of Fontaine's classification, 10 patients at stage III and 41 patients at stage IV) referred for interventional treatment were included. 173 EGDs, 169 TEEs and 188 retinoscopies were performed within one week prior to fibrinolysis. 114 patients had all three examinations. RESULTS: Pathologic findings were detected in 56 (49%) of the 114 patients: 23 erosions, 12 ulcers, 2 esophagites, 1 gastric carcinomata, 3 intracardiac thrombi, 5 aortic thrombi, 11 diabetic and 5 hypertensive retinopathies and 1 with retinal aneurysms. 30 patients (25%) received fibrinolytic therapy, despite a contraindication: The one patient with ventricular thrombus was treated as an ultimate therapy, and amputation was prevented. Two patients showing plaques covered by large thrombi in the descending thoracic aorta were treated because cranial embolism should not occur. Four diabetic patients with multilevel disease, severe claudication and prior retinal bleeding were treated. Fibrinolytic therapy was started on 23 patients after complete healing of the mucosal lesions. CONCLUSION: TEE revealed potential sources of embolization in 4% of the patients and is justified to reduce the individual risk. Retinoscopy should be done in patients with diabetes mellitus and hypertension, and if prior bleeding is present fibrinolysis should be done only if other treatment-regimes are not available.

Aged↗

[MR Angiography: First choice for diagnosis of the arterial vascular system].

Contrast medium-enhanced, 3D MR angiography enables an extensive and diagnostically accurate evaluation of arterial vessels in the neck, thorax, abdomen, and limbs. Advances in the field of MR apparatus technology and the introduction of contrast-medium enhanced MR angiographic techniques have made this development possible. Contrast medium-enhanced MR angiography combines the intravenous bolus administration of a paramagnetic contrast medium with the rapid acquisition of 3D datasets. The possibilities for obtaining data in the thorax and abdomen within one breath-hold, the resulting high contrast between vessel lumen and surrounding soft tissue as well as the inherent 3D nature of the images allow for diagnostically relevant image quality. In many centers contrast-enhanced 3D MR angiography has widely replaced the conventional digital subtraction roentgenography for the clarification of pathologies in arterial vessels. This review presents a survey of the technical background of contrast medium eýnhanced 3D MRA. In addition, the spectrum of indications is given and discussed on the basis of clinical examples.

Arteries↗

Rapid magnetic resonance angiography for detection of atherosclerosis.

BACKGROUND: Choice of treatment for atherosclerosis depends on various clinical factors and radiological techniques. We aimed to assess the diagnostic accuracy of a new three-dimensional magnetic resonance angiography (3D MRA) strategy for the display of arterial vasculature from supra-aortic arteries to distal runoff vessels in 72 s. METHODS: We examined five healthy volunteers and six patients over 6 weeks. Conventional digital subtraction angiography (DSA) was available as reference standard in all six patients. Magnetic resonance imaging was done on a commercially available 1.5 Tesla scanner. The imaging technique was based on the acquisition of five 3D data sets in rapid succession with an optimum single injection protocol. FINDINGS: Compared with conventional catheter angiography, according to the findings of two independent and masked readers, whole-body MRA had overall sensitivities of 91% (95% CI 0.76-0.98) and 94% (0.8-0.99), and specificities of 93% (0.85-0.97) and 90% (0.82-0.96) for the detection of substantial vascular disease (luminal narrowing >50%), interobserver agreement for assessment of whole-body magnetic angiograms was very good (kappa=0.94; 95% CI 0.9-0.98). INTERPRETATION: The technique provides a comprehensive non-invasive approach for morphological screening assessment of the arterial vasculature from supra-aortic arteries to the distal runoff arteries.

Adult↗

Dynamic 3D MR angiography of the pulmonary arteries in under four seconds.

Although 3D MRA has been shown to provide excellent depiction of the pulmonary arterial tree, its clinical use has been limited due to lengthy breath-holding requirements. Employing the newest gradient generation (1.5 T MR system, amplitude of 40 mT/m and a slew rate of 200 mT/m/msec), we evaluated a technique permitting the dynamic acquisition of 3D data sets of the entire pulmonary tree in under 4 seconds. Coronal image sets were collected using a repetition time of 1.64 msec and an echo time of 0.6 msec, resulting in an acquisition time of 3.74 seconds. Three volunteers and eight dyspneic patients with known or suspected pulmonary embolism underwent MRI of the pulmonary arteries. The pulmonary arterial tree was visible to a subsegmental level in all examined subjects. Regarding the presence of pulmonary emboli in four patients, there was complete concordance between MR angiographic findings and those of corroborative studies. We conclude that diagnostic MRA of the pulmonary vasculature can be obtained even in patients with severe respiratory distress.

Dyspnea↗

Pulmonary arteriovenous malformation: Characterization with time-resolved ultrafast 3D MR angiography.

To avoid potentially deadly consequences from paradoxical emboli, early detection and accurate characterization of pulmonary arteriovenous malformations (AVMs) is highly desirable. We report on a patient with a suspected pulmonary AVM who underwent ultrafast time-resolved 3D MR angiography of the pulmonary arteries. The case documents the suitability of the MRA technique as a noninvasive alternative to computed tomographic angiography and digital subtraction angiography for accurate pre-therapeutic characterization of pulmonary AVMs.

Arteriovenous Malformations↗

Improved multi-station peripheral MR angiography with a dedicated vascular coil.

Delineation of small branch vessels can be crucial for assessing the peripheral arterial system of patients requiring surgical grafting. Thus signal-to-noise needs to be maximized. We evaluated the performance of a dedicated peripheral vascular coil in four subjects by comparing it to the body coil using DSA as the standard of reference. SNR and CNR values of the dedicated peripheral coil exceeded those obtained with the body coil by a mean of 398%, thus permitting improved delineation of the infrapopliteal arterial morphology.

Adult↗

0.5 M Gd chelate (Magnevist) versus 1.0 M Gd chelate (Gadovist): dose-independent effect on image quality of pelvic three-dimensional MR-angiography.

To compare the effect on image quality of a 1.0 M gadolinium (Gd) chelate to that of a conventional 0.5 M Gd chelate, five healthy volunteers and seven patients with angiographically documented aorto-iliac disease underwent a mono-station three-dimensional magnetic resonance angiography (MRA) exam (Siemens SONATA, Erlangen, Germany) twice, once using Gadovist 1.0 and the other time using Magnevist as the contrast agent. All subjects received a fixed volume of Gadovist 1.0, corresponding to a dose between 0.1 and 0.15 mmol/kg body weight followed by a saline flush. For the Magnevist exam, the contrast agent volumes and flow rates were doubled. For both quantitative and qualitative analysis of the angiographic data sets, the arterial tree was divided into nine segments. 1 M Gadovist 1.0-enhanced three-dimensional MRA data sets were characterized by significantly higher signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) values compared to 0.5 M Magnevist-enhanced images. The data revealed mean SNR/CNR increases exceeding 70% (P < 0.01). Although there was no statistically significant difference in the rating of image quality (P > 0.05), the Gadovist 1.0 exam led to better delineation of the arterial morphology, especially of small vessels.

Adult↗

[Modern diagnostic concepts in dissection and aortic occlusion].

For the diagnostic work-up of the aorta, non-invasive cross-sectional imaging techniques have almost replaced invasive catheter angiography. CT- and MR-angiography are supplemented by sonography which is used predominantly for the assessment of abdominal aortic aneurysm and dissections of the thoracic aorta. This review deals with the diagnostic approach to two disease entities involving the aorta: aortic dissection and aortic occlusion. Transoesophageal echocardiography (TEE), CT- and MR-angiography (MRA) are used in the assessment of aortic dissection. Published sensitivity and specificity values regarding the detection and classification of dissections into Stanford A and Stanford B range between 96-100% for all three modalities. Results for multislice CTA have not yet been reported, but can be expected to be at least as good. The ability to delineate additional information regarding the precise morphology of true and false lumen, entry and reentry-sites, the development of thrombus or paraaortic hematomas, as well as the assessment of aortic regurgitation or involvement of coronary arteries depend on the chosen technique. Reflecting the ability to collect functional imaging data, both TEE and MRA are superior to CTA in the assessment of aortic valve involvement, while TEE is the modality of choice for evaluation of coronary arteries. Sonography is of limited use in the assessment of abdominal dissections. For the evaluation of patients with suspected aortic occlusion both CTA and MRA represent the imaging modalities of choice. Both provide for a comprehensive and precise depiction of the underlying aortic morphology, the extent of collateral flow as well as delineation of distal run-off vessels. MRA should be employed in patients with impaired renal function as paramagnetic contrast agents are not nephrotoxic.

Aged↗

[Contrast-enhanced 3D MR venography of central thoracic veins: preliminary experience].

PURPOSE: To evaluate the usefulness of three-dimensional (3D) gadolinium-enhanced magnetic resonance (MR) venography for evaluation of thoracic central veins. MATERIALS AND METHODS: Over a 4-month period, 14 patients with suspected central venous abnormalities were examined on a 1.5 T scanner (Magnetom Sonata, SIEMENS, Germany) by means of MR venography. A FLASH-3D sequence using the following parameters was employed: TR 1.6 ms, TE 0.6 ms, TA 3.74 s, flip: 15 degrees, slab thickness 110 mm, effective slice thickness: 2.75 mm, 40 partitions, FOV 360 mm, matrix 140 x 256. 10 s prior to imaging 20 ml of Gd-DOPTA (Multihance, BRACCO, Italy) were automatically injected (MEDRAD, Pittsburgh, USA) flushed by 20 ml of normal saline (flow 4 ml/s). Six 3D data sets were acquired in immediate succession in under 24 s. Results were corroborated with findings from duplex sonography. RESULTS: MR venograms were of diagnostic quality for all 14 patients. Compared to duplex sonography thromboses, post-thrombotic changes as well as functional compressions were reliably detected. Unsuspected findings were found in two patients. CONCLUSION: The outlined strategy allows for dynamic diagnostic imaging of central thoracic veins. Gadolinium-enhanced breath-hold 3D MR venography is easy to perform, well tolerated and highly accurate in assessing central venous pathology.

Adult↗