Search PubMed⌕ Search

Biomedical subjects

M Gottwik

Publications and source records attributed to M Gottwik.

60 records · Page 4Linked to original sources

Development of collaterals. Application of external subcritical fixed constrictors in a canine model.

A canine model for a standardized induction of collaterals is presented with a fixed external constrictor that is not designed to induce an occlusion of the coronary artery and at least over the timespan of 6 weeks does not impair perfusion under resting conditions in the myocardium-at-risk. The coronary constriction was standardized by a reduction of the postocclusive reactive hyperemia of 50%. Flow measurements were performed by flowmeter and by radioactive microspheres acutely and after an interval of 6 weeks of constriction. The results showed an increase of the collateral flow from 21.2 +/- 11.8 ml/100 g/min-1 to 42.8 +/- 16.2 ml/100 g/min-1 (p less than 0.05). The regional perfusion exhibited a transmyocardial gradient in favour of the subepicardial layers with 49.3 +/- 25 ml/100 g/min-1 as compared to 33.1 +/- 17.3 ml/100 g/min-1 (p less than 0.05) of the endocardial layers. Reactive hyperemia, as determined by flowmeter, was decreased by 21% after 6 weeks on account of slow progression of the coronary constriction due to intimal reactions, whereas reactive hyperemia, as determined by the microsphere method, increased by 9% due to additional collateral channels.

Animals↗

The relationship between the perfusion deficit, infarct size and time after experimental coronary artery occlusion.

It is well known that coronary occlusions of short duration do not produce infarcts in the dog heart, but permanent occlusions always do. The aim of this paper was to investigate with quantitative direct measurements the determinants of infarct size within these two extremes. We measured left ventricular MV2, coronary and collateral blood flow and infarct size after occlusion times varying between 45 minutes and 24 hours. MVO2 was kept low in one group by establishing low heart rates with a synthetic opiate. In another group, MV2 was kept elevated by giving synthetic catecholamines (dobutamine) that stimulated contractility and heart rate. Under the described experimental conditions LV-coronary blood flow reflected the true demand for blood and oxygen. The ratio of collateral blood flow over coronary blood flow (both measured with tracer microspheres) was therefore a good approximation of the supply-demand ratio (SD). Since collateral flow was inhomogeneously distributed across the left ventricular wall, the SD-ratio showed similar variations. As the collateral blood flow increased with elapsed time after coronary occlusion, the SD-ratio improved. Since high LV-O2-demand increased coronary flow but exerted practically no influence on collateral flow, this situation influenced the SD-ratio in a negative way. Decreased O2-demand had the opposite effect. The SD-ratio is thus a valid expression of the relative and absolute blood flow deficit as influenced by the local and general O2-demand. We found significant and characteristic correlations between the SD-ratio and infarct which was only influenced by time. A blood flow deficit of 90% (i.e., collateral flow = 10% of required flow) produced a 50%-infarct (relative to the risk-region) with a 45-min occlusion but a 90%-infarct with occlusion times of 3 hrs and longer. If the perfusion deficit is only 0.5 (collateral flow = 50% of required flow), no infarct is detectable at occlusion times shorter than 3 hrs. Small perfusion deficits of only 20% below required flow caused infarctions at 24 hrs and longer. In the group where the SD-ratio was closer to unity because of a low overall LV-O2-consumption (bradycardia), infarcts at t = 24 hrs were significantly smaller than in the group with a high LV-MVO2.

Animals↗

Experimental myocardial infarction in a closed-chest canine model. Observations of temporal and spatial evolution over 24 hours.

Myocardial infarction was induced in 7 mongrel dogs by transfemoral intraluminal occlusion of the left anterior descending coronary artery. Perfusion area at risk was determined by post-mortem coronarography and infarct size by macrohistological staining with para-nitrophenoltetrazolium. Regional flow was determined by injection of radioactive microspheres 0.2 hours, 12 hours, and 24 hours post occlusion. Infarct size as determined by planimetry of post-mortem angiograms and macrohistological stains at identical magnification revealed 74.5 +/- 12.1% infarcted tissue of the perfusion area at risk. The flow of the necrotic tissue was below 13 Ml/100 g min without exception, indicating a threshold perfusion for maintenance of myocardial viability. Accordingly, a flow of less than or equal to 10 ml/100 g min identified 93% of the entire infarcted myocardium, resulting in 71 +/0 20% as compared to the perfusion area at risk. Based on the good agreement of macrohistological and flow data, the evolution of myocardial injury was determined by flow measurements. The results indicated a different progression of the borders of critical flow in the subendocardial and subepicardial layers, whereas in the subendocardium 85% of the tissue at risk was identified by the critical flow at 0.2 hours and 97% at 12 hours, the subepicardial flow changed at a different pace: only 53% showed subcritical perfusion at 0.2 hours, 61% at 12 hours with a final increase of 39% from 12 to 24 hours.

Animals↗

Heart valve replacement with the new all-pyrolytic bi-leaflet St. Jude medical prosthesis.

Since February 1978, seventy-nine St. Jude medical prostheses have been implanted in seventy-two patients with an overall mortality of 8.5%. Clinical, hemodynamic and hematological findings are presented. Twenty-two patients have been catheterized postoperatively, and findings are presented. In vitro comparisons have made between the St. Jude and other prostheses.

Adolescent↗