[Comparison of conventional and high resolution 2D RARE MRCP in diagnosis of pancreaticobiliary diseases].

PURPOSE: Evaluation of high-resolution 2D-RARE MRCP in the diagnosis of pancreaticobiliary diseases. MATERIALS AND METHODS: 23 patients with various pancreaticobiliary diseases were evaluated using conventional and high-resolution 2D-RARE sequences. RESULTS: High-resolution RARE MRCP allowed for improved delineation of biliary and pancreatic ducts at the expense of reduced signal-to-noise ratio. Pathological findings were significantly (p < 0.001) better demonstrated with high resolution RARE MRCP (score 1.65 +/- 0.54) as compared to the conventional RARE sequence (score 2.58 +/- 0.62). CONCLUSIONS: High-resolution 2D-RARE-MRCP improves the delineation of biliary and pancreatic ducts. This sequence should replace the conventional 2D-RARE sequence.

Adult↗

[The role of electron beam CT in the diagnosis of acute pulmonary embolism--presenting a new examination protocol].

PURPOSE: To evaluate electron beam tomography in the detection of acute pulmonary embolism using a new acquisition protocol. MATERIALS AND METHODS: 65 patients underwent electron beam tomography (EBT) and v./p. scintigraphy. According to the inclusion criteria 46 patients participated in the study. Contrast enhancement and detectability of pulmonary arteries were scored on a 4 step scale for image quality. The results of prospective detection of pulmonary embolism were compared for both modalities (blinded reading). "Embolism", "questionable embolism" and "no embolism" were used as categories. RESULTS: 22/46 patients (48%) showed acute pulmonary embolism. EBT and scintigraphy were discordant in 24% of patients. In EBT 1 false positive and 1 false negative case occurred, scintigraphy demonstrated 2 false negative and 3 false positive cases. 6/9 patients with questionable findings in scintigraphy were correctly classified by EBT to a category "embolism" or "no embolism" as "suspected embolism", EBT displayed a sensitivity of 96.3% and a specificity of 94.7%. Scintigraphy evidenced a sensitivity of 93.7% and a specificity of 84.4%. CONCLUSIONS: EBT shows better results than scintigraphy for the detection of acute pulmonary emboli. The evaluated new acquisition protocol for EBT seems to be well suited. High vessel contrast and thin slices allow a reliable detection of segmental and subsegmental pulmonary arteries.

Acute Disease↗

[1H-MR spectroscopy in anorexia nervosa: the characteristic differences between patients and healthy subjects].

PURPOSE: The neurophysiological and neuromorphological changes in patients with anorexia nervosa (AN) are well-known but the reason of both is still unknown. We have evaluated the usefulness of hydrogen (H1) magnetic resonance spectroscopy in anorexia nervosa. METHOD: We investigated 15 patients with clinically diagnosed AN (ICD F50.0) and 17 controls without eating disorders. The body mass index (BMI) was 15.8 and 21, respectively. The spectroscopy was recorded on two voxels in the parieto-occipital white matter or in the thalamus with a water-suppressed STEAM-sequence. The metabolites were recorded with respect to phosphocreatine (PCr). RESULTS: The ratio of NAA/PCr in both voxels were not significantly different when comparing patients vs. controls. Patients showed significantly higher ratios of choline-containing components (Cho) or, respectively Cho/PCr and NAA/PCr in the white matter. Distinct, but not significant differences were detected both for m-Ino and m-Ino/PCr in the parieto-occipital region and for the Cho- and m-Ino contained ratios in the thalamus. CONCLUSION: AN is not associated with neuronal damage. The ratio of Cho/PCr and NAA/Cho may reflect the disturbance of membrane-turnover. It is possible that the increase of membrane catabolism leads to a hyperosmolar state. The change of m-Ino/PCr ratio may reflect the regulation of osmolarity.

Anorexia Nervosa↗

[1H-MR spectroscopy in anorexia nervosa: reversible cerebral metabolic changes].

PURPOSE: By using localized 1H-MR spectroscopy in the brain of patients with anorexia nervosa we wanted to verify our preliminary results and to look for a reversibility of the metabolic changes under therapy. METHODS: In 22 patients and 17 healthy volunteers (11 follow-up examinations) single voxel 1H-MR spectroscopy (TE = 50 ms, TM = 30 ms, TR = 1500 ms, voxel (2 cm)3, acq.: 256) was used in two different localizations (thalamus and parieto-occipital region). The first examination of the patients was performed before therapy, the follow-up examination at the end of therapy. RESULTS: In both regions of the brain we found a statistically significant elevation of the Cho/Cr-ratio in comparison to normal controls. The follow-up examinations revealed reversibility of the metabolic changes under successful therapy. CONCLUSIONS: 1H-MR spectroscopy reveals metabolic changes in the brain of patients with anorexia nervosa, which are reversible under successful therapy. These metabolic changes can be conclusively explained using a biochemical model.

Adolescent↗

[The value of magnetic resonance tomography (MRT), magnetic resonance cholangiopancreatography (MRCP) and endoscopic retrograde cholangiopancreatography (ERCP) in the diagnosis of pancreatic tumors].

PURPOSE: To prospectively evaluate the role of MRI including MR cholangiopancreatography (MRCP) compared to endoscopic retrograde cholangiopancreatography (ERCP) in the diagnosis of pancreatic cancer. MATERIAL AND METHODS: ERCP and MRI including MRCP were performed in 52 patients with suspected pancreatic cancer. MRCP was obtained using a single-shot RARE technique. The results of axial images and MRCP were compared to concurrently performed ERCP examinations. The standards of reference were the surgical and pathological findings, respectively. Image quality of MRCP was assessed using a three-step-score (1 = good, 2 = fair, 3 = nondiagnostic). RESULTS: In 88% of the cases the MRCP was of good quality. Only in 4% was MRCP non-diagnostic. The combination of MRI and MRCP showed an overall accuracy of 88%, whereas the overall accuracies of MRCP alone and ERCP were 80%, and 85%, respectively. The positive predictive values of MRI/MRCP, MRCP alone, and ERCP were 91%, 85%, and 88%, respectively. CONCLUSION: For the detection of pancreatic cancer MRI including MRCP is comparable to ERCP and can be regarded as the method of choice in patients with suspected pancreatic cancer. ERCP is the procedure of choice in patients with contraindications to MRI and in patients in whom additional therapeutic procedures are performed.

Adenocarcinoma↗

[Combined use of MRI and MR cholangiopancreatography and contrast enhanced dual phase 3-D MR angiography in diagnosis of pancreatic tumors: initial clinical results].

PURPOSE: To evaluate the accuracy of a non-invasive "all-in-one" staging MR method in patients with pancreatic tumors. MATERIAL AND METHODS: 46 patients were prospectively evaluated by a combined MR imaging protocol including breath-hold T1- and T2-weighted pulse sequence, MRCP using a breath-hold 2D-RARE sequence, and breath-hold gadolinium-enhanced dual-phase 3D-MR angiography. RESULTS: All pancreatic tumors were detected by the combination of cross-sectional imaging and MRCP. In spite of the use of MRCP, definitive differentiation between pancreatic carcinoma and chronic pancreatitis was not possible in 3 (6.5%) out of 46 cases. High quality 3D-MR angiograms were obtained in 43 (93.5%) cases. In 6 (13%) patients 3D-MRA showed an aberrant right hepatic artery. The overall accuracy of MRI in assessing extrapancreatic tumor spread, lymph node metastases, liver metastases, and vascular involvement was 95.7%, 80.4%, 93.5%, and 89.1%, respectively. CONCLUSION: Due to its high accuracy, the "all-in-one" MR protocol may become the most important modality after clinical examination and ultrasound in the diagnostic work-up for most patients with suspicion of pancreatic tumors.

Arteries↗

Dose and image quality of electron-beam CT compared with spiral CT.

RATIONALE AND OBJECTIVES: To examine dose and image quality of electron-beam CT (EBCT) with continuous volume scan versus spiral CT. METHODS: An EBCT scanner was compared with a spiral CT (SCT) scanner. Three phantoms were used to measure low-contrast resolution, high-contrast resolution, slice width, and dose. RESULTS: The EBCT scans showed 30% lower high-contrast resolution for most settings. The dose was comparable to that of spiral CT with 3 mm collimation and 76%/106% higher with EBCT for 1.5 mm/6 mm collimation. Low-contrast resolution was comparable to that of spiral CT using 3 mm collimation, slightly worse for 1.5 mm, and bad for 6 mm EBCT collimation (four times higher dose to reach comparable contrast-to-noise ratio). CONCLUSIONS: Significant restrictions were found using EBCT with continuous volume scan. The authors found that 3 mm collimation can yield acceptable high-contrast resolution and good low-contrast resolution compared with spiral CT. The use of 6 mm or 1.5 mm collimation needs to be restricted to selected cases.

Evaluation Studies as Topic↗

MR imaging of pancreatic lesions. Comparison of manganese-DPDP and gadolinium chelate.

RATIONALE AND OBJECTIVES: To compare manganese-DPDP-enhanced and gadolinium-DTPA-enhanced MR imaging in patients suspected of having pancreatic cancer. METHODS: Fifteen patients who underwent MR imaging for suspected pancreatic cancer and received gadolinium-DTPA took part in a clinical phase III trial in which the efficacy of manganese-DPDP for detection of pancreatic cancer was evaluated. T1-weighted gradient-echo (GRE) images with and without fat suppression were used. Signal-to-noise ratio and contrast-to-noise ratio were calculated before and after the administration of each contrast agent. Image quality was assessed using a four-step score; delineation of the normal pancreas was assessed by two readers in consensus. RESULTS: In terms of pancreatic signal-to-noise ratio, only gadolinium-DTPA-enhanced fat-suppressed and non-fat-suppressed GRE imaging showed a significant (P < 0.001) increase (72% and 61%, respectively). In the patients with a focal pancreatic lesion (n = 14), a significant increase in contrast-to-noise ratio was found only in manganese-DPDP-enhanced GRE imaging without (106%) and with (82%) fat saturation. Qualitative image analysis demonstrated a significant improvement of manganese-DPDP-enhanced fat-suppressed MR images in delineating the pancreatic parenchyma (P < 0.01) as well as pancreatic tumors (P < 0.01). CONCLUSIONS: T1-weighted manganese-DPDP-enhanced GRE imaging with fat saturation should be regarded as the most suitable combination for detecting a pancreatic lesion.

Adult↗

[Lymph node imaging with ultra-rapid 3D MR angiography].

PURPOSE: A report on observations of lymph node images obtained by gadolinium-enhanced 3D MR angiography (MRA). METHODS: Ultrarapid MRA (TR, TE, FA-5 or 6.4 ms, 1.9 or 2.8 ms, 30-40 degrees) with 0.2 mmol/kg BW Gd-DTPA and 20 ml physiological saline. Start after completion of injection. Single series of the pelvis-thigh as well as head-neck regions by use of a phased array coil with a 1.5 T Magnetom Vision or a 1.0 T Magnetom Harmony (Siemens, Erlangen). We report on lymph node imaging in 4 patients, 2 of whom exhibited benign changes and 2 further metastases. In 1 patient with extensive lymph node metastases of a malignant melanoma, color-Doppler sonography as color-flow angiography (CFA) was used as a comparative method. RESULTS: Lymph node imaging by contrast medium-enhanced ultrarapid 3D MRA apparently resulted from their vessels. Thus, arterially-supplied metastases and inflammatory enlarged lymph nodes were well visualized while those with a.v. shunts or poor vascular supply in tumor necroses were poorly imaged. CONCLUSIONS: Further investigations are required with regard to the visualization of lymph nodes in other parts of the body as well as a possible differentiation between benign and malignant lesions.

Adult↗

Economic analysis of teleradiology applications with KAMEDIN.

The teleradiology system KAMEDIN (German Telekom), installed on HP-Unix- and NT-Workstations, was evaluated in different scenarios and a cost-benefit-analysis was performed. CT examinations were transferred from a PACS workstation (GE) to KAMEDIN using DICOM-3 protocol. Teleconferences were realized with an intensive care unit by LAN, with a radiology department at 5 km. distance by ISDN, and with an on duty radiologist 22 km. away by ISDN. On average, 36 CT slices per patient were transferred. Overall costs (costs for hardware, software, support, ISDN-fees, and staff) were compared to possible cost reduction, mainly concerning transportation and films. These three scenarios could be realized during daily routine work. Differing in their amount of transportation cost reduction, two applications (intensive care unit, radiologist on duty) showed a break-even at 1817, respectively 528 teleconferences/year. Improvement of cost-effectiveness can be obtained on the conditions that existing hardware will be used and that the automatic data transfer will be improved. Combining all optimisation factors, the break-even decreased to a minimum of 167, respectively 77 teleconferences/year. The optimisation of patient management is an additional--but in this study, not yet counted--advantage of teleradiology.

Computer Communication Networks↗

Proton magnetic resonance spectroscopy in acute, juvenile anorexia nervosa.

Anorexia nervosa is usually associated with a shrinkage of the brain that is at least partially reversible with weight gain. The pathogenesis of this brain abnormality is unclear. The purpose of this study was to investigate potential alterations in localized proton magnetic resonance (1H MR) spectra of anorectic patients immediately after an interval of excessive weight loss. Twelve patients and seventeen control subjects were examined. Water suppressed 1H MR spectra were recorded from two voxels placed in the thalamus and in the parieto-occipital white matter. The spectra of ten patients could be evaluated. Comparing patients and control subjects, significantly higher signal intensity ratios of choline containing compounds (Cho) relative to total creatine (Cr) as well as significantly lower ratios of N-acetyl-aspartate (NAA) relative to Cho were found in the white matter region. We hypothesize that these results indicate an abnormal starvation, associated membrane turnover, which predominantly takes place in the white matter. No evidence for neuronal degeneration was found in the thalamus or in the white matter region.

Adolescent↗

[Performance of electron-beam CT: continuous-volume-scan compared to spiral CT].

To compare patient dose and image quality of electron-beam-CT vs. spiral-CT by means of phantom measurements. An EBCT scanner (C-150 XP) and a spiral-CT scanner (GE HiSpeed Advantage) were used to scan three different phantoms. Administered dose, high contrast (HC) resolution, low contrast (LC) lesion detectability and the width of the radiation beams were measured. EBCT showed 25-35% lower HC resolution in comparison to spiral-CT. LC lesion detectability showed equivalent results for S/N vs. patient dose using 3 mm collimation with EBCT and spiral-CT, whereas spiral-CT was superior for 1.5 and 6 mm collimation. Dose measurements revealed a 2 fold higher patient dose using EBCT with 1.5 mm or 6 mm collimation compared to spiral-CT using equivalent scan parameters. No differences were seen using 3 mm collimation. Differences were due to insufficient beamside collimation of the EBCT. The use of EBCT with 6 mm collimation should be avoided, because of impaired performance. Using 3 mm collimation, EBCT showed comparable performance like state of the art spiral-CT despite lower HC resolution.

Algorithms↗

[Electron-beam CT-angiography in abdominal aortic aneurysms. Initial results].

PURPOSE: To evaluate the suitability of ultrafast electron-beam tomography (EBT) for the investigation of abdominal aortic aneurysms using CTA. METHODS: Thirty-one patients with suspected abdominal aortic aneurysm were investigated with EBT using an Evolution XP scanner (Siemens, Erlangen) with the newest software version 12.34 with continuous volume scanning of 140 images in 17 s. Collimation was 3 mm, table increment 4 mm with overlapping image reconstruction every 2 mm, exposure time 200 ms (124 mAs), resulting in a scan-range of 28 cm. A quantity of 80 ml contrast material was administered (flow 4 ml/s). Visualization of the abdominal aorta and its branches was performed with MIPs and shaded surface display. Evaluation of image quality was based on a four-step classification scale (1 = good, 4 = insufficient) for the demonstration of the abdominal aorta and the visceral, renal and iliac arteries. RESULTS: All EBT examinations demonstrated high and homogeneous density values along the whole vessel course with a mean density value of 258.7 +/- 47.3 HU for the abdominal aorta and the iliac arteries. Quality evaluation for the vessel demonstration showed mean values between 1.22 and 1.57 for the abdominal aorta and the visceral, renal and iliac arteries. CONCLUSIONS: EBT with 140 slices and slice reconstruction every 2 mm offers a high z-axis resolution resulting in high-quality CT angiographies of the whole abdominal aorta and its branches.

Aged↗