Search PubMed⌕ Search

Biomedical subjects

M Galanski

Publications and source records attributed to M Galanski.

At least 19 recordsLinked to original sources

[Diagnostic imaging of liver tumours. Current status].

Nowadays, contrast enhanced ultrasound (CEUS) is an imaging technique equivalent to multidetector computed tomography (MDCT) and magnetic resonance imaging (MRI) for the detection and characterization of focal liver lesions. These methods have comparable sensitivity and specificity in differentiating a liver lesion as "benign" or "malignant". For benign lesions, CEUS is the recommended method of the choice. In unclear cases, or if CEUS is not available, MRI or CT are the methods of the second choice. If a benign tumor remains unclear, then a needle biopsy is recommended. In the case of a malignant tumor, it is necessary to use a second imaging technique besides CEUS. In addition to the detection and characterization of a liver tumor, CT and MRI provide information on the extrahepatic spread of a tumor, particularly into the lung or retroperitoneum. The rapid development of surgical and interventional approaches requires accurate information on the character and number of malignant liver lesions. Therefore, the combined use of CEUS and MDCT or MRI currently represents the most modern and optimal standard of imaging. The standardization of CT and MRI protocols has increased the general diagnostic level of these images. Adequate training and a certificate for the use of CEUS is recommended in order to maintain the high diagnostic level of this method (EFSUMB guide lines). An optimal interdisciplinary imaging strategy for focal liver lesions minimises unnecessary invasive or potentially harmful imaging and reduces health costs.

Contrast Media↗

[MDCT classification of osseous ankle and foot injuries].

Conventional radiography plays an essential role in the primary evaluation of acute ankle and foot trauma. In the case of complex injuries, however, subsequent computed tomography (CT) is nowadays recommended. In this connection, multidetector computed tomography (MDCT) allows better temporal, spatial, and contrast resolution compared with the conventional single-slice spiral CT. Multiplanar reformation and three-dimensional reconstruction of the acquired data sets are also helpful tools for critical assessment of therapeutic intervention. This report reviews the potential of the MDCT technique for accurate fracture classification, precise illustration of displaced components, and postoperative control of arrangement of typical lesions.

Ankle Injuries↗

[Pelvic and perineal trauma. Diagnosis and interventional radiotherapy].

The integration of multislice CT (MSCT) in the imaging of emergency trauma has led to a paradigm shift in trauma management. In case of hemodynamically instable patients, initial imaging is limited to a small set of standardized radiographs. Computed tomography is the imaging modality of choice for further diagnostic work-up. Consequently it should be used at an early stage and in a less restricted manner for complete assessment of the pelvic injury and to determine therapeutic management. The MSCT allows full assessment of bone, parenchymal, and vascular injuries in a single examination in the shortest time possible. High-resolution 3D imaging provides additional options. There is increasing support for primary use of MSCT in critically ill patients due to the comprehensive imaging it allows while maintaining a fast scan time. The potential and limitations of diagnostic imaging in pelvic ring fracture and associated injuries are explained. Indications for vascular interventions in arterial bleeding are discussed.

Acetabulum↗

[Partial k-space sampling with zero filling used with phase-contrast flow measurements: in vivo and in vitro validation].

PURPOSE: To validate the technique of partial k-space sampling and zero filling with phase-contrast flow measurements as compared to measurements with full k-space sampling. MATERIALS AND METHODS: In vitro: A laminar flow phantom was utilized to evaluate the effect of partial k-space sampling on the accuracy, precision and signal-to-noise ratio of phase-contrast flow measurements. In vivo: The effect of partial k-space sampling on the quantification of cardiac output (n = 40 patients) and the duration of the scan were evaluated in the ascending aorta (n = 37) and pulmonary trunk (n = 34) in a prospective study. RESULTS: Partial k-space sampling resulted in an increase in the SNR by 2 % in vitro. The precision was altered by less than 1 %. Flow volumes were systematically overestimated by 3.5 %. No significant differences were found in the in vivo measurements of cardiac output. The scan duration was reduced by 34 % by utilizing partial k-space sampling. CONCLUSION: Partial k-space sampling can be used to reduce scan time without a significant decrease in the accuracy or precision of phase-contrast flow measurements in large arteries.

Arteries↗

[Clinical evaluation of a new tonometer on the basis of international standard ISO 8612].

BACKGROUND: There is a continuous process of development of new tonometer types following different measurement principles on the tonometer market. A new tonometer working on the dynamic contour measurement principle is currently available for ophthalmologists. This device has special properties, since it determines the intraocular pressure as well as the ocular pulse amplitude. So far, clinical comparison measurements exist between the new tonometer Pascal and the applanation tonometer by Goldmann albeit without any reference to a standard. Besides, these measurements cover only a small pressure range between 7 mmHg and 23 mmHg which is not sufficient for medical diagnosis. PATIENTS AND METHODS: This new tonometer was investigated by clinical comparison measurements according to the currently valid international standard for human eye tonometers (ISO 8612). The tested tonometer determines the intraocular pressure without fluorescein. In an ophthalmogical hospital in Berlin the clinical comparison measurements were carried out by ophthalmologists on 127 patients according to the methods and criteria of the above-mentioned standard. A calibrated AT 870 from the Haag-Streit company served as reference tonometer. RESULTS: The different cornea surface geometries of individual eyes, the variation of tear liquid volume, and also the different elastic properties of the human eye due to a large variation in rigidity led to measurements of intraocular pressure by this tonometer with an excessively high number of outliers p (i) (i = 1, ..., 3) per group (p (1) = 16.28 %, p (2) = 8.85 %, p (3) = 15.69 %, 5.0 % outliers per group only are permitted for the differences method), which do not correspond to the requirements of the international standard for tonometers ISO 8612. This is also shown by application of total method of least squares of regression line (slope a = 0.964, interception b = 2.868 mmHg, standard deviation s (y) = 2.628 mmHg). CONCLUSIONS: The test of conformity of results of clinical comparison measurements to the international standard for tonometers ISO 8612 is the target of this work. The measurement results of the investigated tonometer are analysed and discussed according to this standard. Statements about the medical application of this medical measurement device for ophthalmologists are presented. According to the presented investigations the requirements of this international standard are not fulfilled by the tonometer Pascal.

Equipment Design↗

Chemoocclusion vs chemoperfusion for treatment of advanced hepatocellular carcinoma: a randomised trial.

AIMS: Transarterial chemoembolization (TACE) can be associated with considerable toxicity and treatment-associated mortality. Transient transarterial chemoocclusion (TACO) using degradable starch microspheres (DSM) has been proposed as a potentially safer alternative while maintaining anti-tumour efficiency. In a randomised phase II trial TACO was compared to transarterial chemoperfusion without DSM (TACP). METHODS: Seventy-four patients with advanced HCC were randomised to two treatment arms: (i) TACO (600-1200 mg DSM) and (ii) TACP. In both arms regional chemotherapy consisted of cisplatin (100 mg/m2) and doxorubicin (60 mg/m2). Both arms were corresponding in terms of age, gender, liver performance state, and tumour-stage. A maximum of six treatment cycles was applied in monthly intervals. Follow-up was performed in terms of tumour response, time to progression, survival and quality of life. RESULTS: Tumour response rates did not differ significantly between the two treatment arms, however, there was a tendency towards higher response rates in the TACO arm (TACO vs TACP): partial response: 26 vs 9%, stable disease: 41 vs 55%, progressive disease: 33 vs 36%. Time to tumour progression (32 vs 27 weeks), and overall survival (60 vs 69 weeks) were not significantly different. Grade 4 adverse events were rare in both arms and treatment-associated mortality was not observed. In addition, there was no significant difference in terms of quality of life under therapy (EORTC). CONCLUSION: TACO with DSM did not improve response or survival significantly compared to TACP in advanced non-resectable HCC.

Aged↗

Survival rate in patients with hepatocellular carcinoma: a retrospective analysis of 389 patients.

Hepatocellular carcinoma (HCC) is the fifth most common cancer worldwide. However, treatment options are limited and often inefficient. The aim of this study was to determine current survival rates for patients diagnosed with HCC and to identify prognostic factors, which will help in choosing optimal therapies for individual patients. A retrospective analysis of medical records was performed on 389 patients who were identified through the central tumour registry at our institution from 1998 to 2003. Clinical parameters, treatments received and survival curves from time of diagnosis were analysed. Overall median survival was 11 months. Liver cirrhosis was diagnosed in 80.5% of all patients. A total of 170 patients received transarterial chemoembolisation (TACE) and/or percutaneous ethanol injections (PEI) with a median survival rate of 16 months for patients receiving TACE, 11 months for patients receiving PEI and 24 months for patients receiving TACE followed by PEI. Independent negative prognostic parameters for survival were the presence of portal vein thrombosis, advanced liver cirrhosis (Child-Pugh score B or C) and a score of >2. This study will help to estimate survival rates for patients with HCC according to their clinical status at diagnosis and the treatments received.

Adolescent↗

Use of 2D histograms for volume rendering of multidetector CT data: development of a graphical user interface.

RATIONALE AND OBJECTIVES: Direct volume rendering reveals 3D information on anatomic structures without preprocessing the data. This increases the interest in this technique as a diagnostic tool. A fast and simple method for setting transfer functions is crucial for clinical routine work. However, this is still a complex task. Present commercial workstations are usually limited to design galleries and window/level functionality. MATERIALS AND METHODS: We present a graphical user interface for volume rendering of multidetector row CT data that permits a much more flexible specification of rendering parameters. A 2D histogram of CT density versus gradient magnitude facilitates the understanding of the spatial connections of different tissues. The incorporation of gradient magnitude into the transfer function domain allows discrimination of features of interest that are not distinguishable on CT density alone. Penetration length, color, and gradient magnitude are depicted on a stack of 2D slices according to the settings of the opacity transfer function and the viewing direction. A gallery of thumbnails with presets of transfer functions is interactively adapted if the volume is rotated or cropped. RESULTS: This allows for fast evaluation of numerous rendering protocols at once. The interface was evaluated with CT data covering skeletal trauma, pathologies of the thorax/abdomen, and CT angiography. CONCLUSION: We observed that high-quality visualizations could be obtained with reasonable interaction times. The 2D histogram and penetration length displays provided valuable insight into the dataset that made the specification of transfer functions a goal-oriented process.

Humans↗

Erdheim-Chester disease versus multifocal fibrosis and Ormond's disease: a diagnostic dilemma.

AIM: The aim of the study was to evaluate the effectiveness of different imaging techniques with respect to diagnosis and differential diagnosis between Erdheim-Chester disease (ECD) and multifocal fibrosis (MF)/Ormond's disease (OD). METHOD: Three cases of ECD were included, two of which were misdiagnosed as MF/OD. Findings in different imaging techniques [plain radiography, skeletal scintigraphy, computed tomography (CT) and magnetic resonance imaging (MRI)] of the lower extremities, chest MRI, craniofacial MRI, abdominal CT and MRI) were compared and ranked with regard to diagnostic efficacy. RESULTS: Differentiation between ECD and MF/OD is only possible by imaging the long bones. Bone roentgenograms and skeletal scintigraphy, followed by MRI and CT of the lower extremities are the most effective imaging techniques. CONCLUSION: A low threshold for carrying out plain radiography of the lower limbs in case of RF/MF will increase the number of ECD-cases.

Bone and Bones↗

[5 years of "concerted action dose reduction in CT" -- what has been achieved and what remains to be done?].

In May 1998, the German "Concerted Action Dose Reduction in CT" was founded by all parties involved in CT. Its intention was to achieve a significant reduction of the radiation exposure caused by CT, a matter that has increasingly been considered a major challenge since the early nineties. As a result of a number of joint efforts, the essential preconditions have been established by now. The fifth anniversary of the Concerted Action gave rise for both retrospection and outlook on the tasks that have already been accomplished and those that still need to be done. For this purpose, a one-day symposium took place in Berlin on November 4, 2003. The contents of a total of 18 contributions will be outlined here in brief.

Adult↗

[CT-based liver volumetry in a porcine model: impact on clinical volumetry prior to living donated liver transplantation].

PURPOSE: Exact preoperative determination of the liver volume is of great importance prior to hepatobiliary surgery, especially in living donated liver transplantation (LDLT). In the current literature, a strong correlation between preoperatively calculated and intraoperatively measured liver volumes has been described. Such accuracy seems questionable, primarily due to a difference in the perfusion state of the liver in situ versus after explantation. Purpose of the study was to asses the influence of the perfusion state on liver volume and the validity of the preoperative liver volumetry prior to LDLT. METHODS: In an experimental study, 20 porcine livers were examined. The livers were weighted and their volumes were determined by water displacement prior and after fluid infusion to achieve a pressure physiologically found in the liver veins. The liver volumes in the different perfusion states were calculated based on CT-data. The calculated values were compared with the volume measured by water displacement and the weight of the livers. RESULTS: Assessment of calculated CT volumes and water displacements at identical perfusion states showed a tight correlation and differed on average by 4 +/- 5 %. However, livers before and after fluid infusion showed a 33 +/- 8 % (350 +/- 150 ml) difference in volume. CONCLUSION: CT-volumetry acquires highly accurate data as confirmed by water displacement studies. However, the perfusion state has major impact on liver volume, which has to be accounted for in clinical use.

Animals↗

Radiation exposure in multi-slice versus single-slice spiral CT: results of a nationwide survey.

Multi-slice (MS) technology increases the efficacy of CT procedures and offers new promising applications. The expanding use of MSCT, however, may result in an increase in both frequency of procedures and levels of patient exposure. It was, therefore, the aim of this study to gain an overview of MSCT examinations conducted in Germany in 2001. All MSCT facilities were requested to provide information about 14 standard examinations with respect to scan parameters and frequency. Based on this data, dosimetric quantities were estimated using an experimentally validated formalism. Results are compared with those of a previous survey for single-slice (SS) spiral CT scanners. According to the data provided for 39 dual- and 73 quad-slice systems, the average annual number of patients examined at MSCT is markedly higher than that examined at SSCT scanners (5500 vs 3500). The average effective dose to patients was changed from 7.4 mSv at single-slice to 5.5 mSv and 8.1 mSv at dual- and quad-slice scanners, respectively. There is a considerable potential for dose reduction at quad-slice systems by an optimisation of scan protocols and better education of the personnel. To avoid an increase in the collective effective dose from CT procedures, a clear medical justification is required in each case.

Data Collection↗

[Intraarterial calcium stimulation (ASVS) for pancreatic insulinoma: comparison of preoperative localization procedures].

PURPOSE: Evaluation of clinical relevance of the arterial stimulation procedure with venous sampling (ASVS) in the preoperative localization of insulinoma. METHODS: Thirteen patients with endogenous hyperinsulinism underwent preoperative transabdominal ultrasound (US), helical CT (CT), MRI, endoscopic ultrasound (EUS), and angiography (DSA) in conjunction with the ASVS-test for the detection of insulinoma. The results were compared with intraoperative findings, intraoperative ultrasound (IOUS) and histology. RESULTS: Sensitivity was as follows: US 8%, MRI 27%, CT 46%, EUS 50%,DSA 69%,and ASVS 92%. Intraoperative palpation and IOUS yielded a sensitivity of 77%. In 3 patients the tumors were neither palpable nor detectable by IOUS, the mode of resection was based on preoperative diagnostics. The ASVS procedure as a functional test was superior to all other modalities for the preoperative tumor detection. CONCLUSION: The ASVS was the most sensitive diagnostic modality. It should especially be considered in terms of health economical aspects when CT or MRI do not yield conclusive results.

Adolescent↗

Ureteric reconstruction.

Although the ureter is functionally simply a tube to transport urine, ureteric surgery requires detailed anatomical knowledge and advanced surgical skills, because the ureter has a delicate blood supply. Therefore, the urological surgeon must have distinct strategies available to bridge ureteric defects of various sites and lengths. Furthermore, handling during and after surgery should be individualized to the patient's pre- and intraoperative situation. In this review, the indications for reconstruction of a specific ureteric defect, the required techniques and postoperative recommendations are discussed.

Humans↗

[Indicators for longterm survival after the transjugular portosystemic intrahepatic shunt procedure].

INTRODUCTION: Complications of portal hypertension can be treated effectively by the transjugular intrahepatic portosystemic shunt procedure (TIPS). Indicators for long time survival after TIPS implantation are presented. PATIENTS AND METHODS: From September 1992 until May 1995 forty-two consecutive patients (26 male, 16 female) with liver cirrhosis complicated by variceal bleeding (n = 27) or refractory ascites (n = 15) were treated by TIPS implantation and followed up clinically in a prospective, open study. The follow up period range was 5-3278 days. Univariate and multivariate regression analyses were applied to determine the correlation between patient characteristics and long term survival after TIPS implantation. The indicators were dichotomized at the median. The outcome variable was dichotomized. Positive outcome was defined as survival longer than three years without liver transplantation, all other outcomes were regarded as negative. Survival rates were determined for all patients and for subgroups according to results of the regression analyses. RESULTS: During follow-up liver transplantation was performed in 8 of the 42 patients. 29 patients died. Mean survival was 1440 (+/-1060) days. Survival after one, two, three and six years was 76% (n = 32), 69%(n = 29), 62% (n = 26) and 38% (n = 16), respectively. The multivariate regression analysis revealed a significant better survival related to a prothrombine time >70%, MEGX synthesis >30 microgram/l, and ICG clearance <13 min. Patients with high ICG clearance (OR = 1.9), high MEGX synthesis (OR = 5.0) or high prothrombine time scores (OR = 5.2) had a significantly longer survival. This survival advantage increased with follow up time. CONCLUSION: Longterm survival after TIPS implantation is influenced by the initial liver function. This survival advantage increases during follow up and is most pronounced after 6 years.

Adult↗