Search PubMed⌕ Search

Biomedical subjects

M Günthner

Publications and source records attributed to M Günthner.

2 recordsLinked to original sources

Stereotactic biopsies guided by an optical navigation system: technique and clinical experience.

Frame-based stereotactic biopsies are time-consuming procedures making necessary head fixation in a ring, explicit coordinate calculation and setting of the parameters. Frameless systems make many of these intermediate steps unnecessary, impose less mechanical restrictions regarding access to the lesions, and with slight modifications can be used to perform stereotactic biopsies. A special adaptation designed to fix the holder and the biopsy instrument is described. The neuronavigation optical tracking system of Radionics was used. CT scans were performed with 6 skin markers. Calibration was performed after head fixation in the Mayfield clamp. Mean calibration error was 2.19 +/- 0.81 mm. The light-emitting diode holder of the pointer was fixed into 2 Leila arms and moved under visual control based on CT images. The target point was selected, Leila arms fixed and a burr hole performed. The cannula was introduced to the target, being fitted with a depth stop in a length identical to that of the pointer on the screen. If necessary a second trajectory was easily selected. 49 patients underwent a frameless stereotactic biopsy. All targets except seven were superficial or in the white matter. In selected cases the biopsies were taken from deep-seated lesions. A histological diagnosis was obtained in 100 % of the cases. Four cases deteriorated postoperatively, two of these related to intratumoral bleeding. Navigation is a simple and effective method to perform biopsies of superficial and relatively large lesions. Frame-based procedures are restricted to brainstem tumors and lesions less than 1.5 cm in diameter.

Adolescent↗

Cavernous malformations: from frame-based to frameless stereotactic localization.

An exact surgical approach to cavernous malformations, in particular those located in areas of critical brain function, is important for their microsurgical resection without putting too much strain on the patient. During a two-year period, 29 cavernoma resections were performed. Stereotactic guidance was performed in 16 cases (55.2%). Nine cavernomas located in the supratentorial region were resected using the stereotactic operating microscope "MKM", which represents 21.6% of a total of 51 MKM-navigated operations; in one further case system referencing failed. The experience gathered with this frameless stereotactic system is compared to a retrospective analysis of 5 frame-based stereotactic cavernoma localizations. Frameless stereotactic localization has been shown to be sufficiently accurate but more advantageous than frame-based techniques in terms of utility, ease of integration, and detailed image-guided anatomical information. Software improvements have resulted in a high stability of the frameless stereotactic system.

Adult↗