Search PubMed⌕ Search

Biomedical subjects

M Francaux

Publications and source records attributed to M Francaux.

21 records · Page 2Linked to original sources

A new procedure to determine external power output during handrim wheelchair propulsion on a roller ergometer: a reliability study.

This study presents a mathematical model by which power output (PO) delivered to the rear wheel during handrim wheelchair propulsion on a roller ergometer can be determined for individual wheelchair-user combinations. PO is calculated from the torque applied to the wheel and its angular velocity. The torque applied is a function of one total internal torque of the wheelchair-ergometer system, the rotational moment of inertia of the rear wheel, the one of the roller and its angular acceleration. The total internal torque reflects all internal friction forces and is determined with a deceleration test. To assess the reliability of this approach, 11 able-bodied subjects underwent progressively increasing exercise tests on two different occasions. PO values ranged from 12 to 63 W and were highly reliable (r2 > 0.95). Peak physiological responses were never different from test 1 and 2 (repeated measures ANOVA; p: N.S.) and correlations were 0.90, 0.72, 0.88, 0.82, 0.70 and 0.85 for PO, oxygen uptake (VO2), heart rate, minute ventilation, carbon dioxide production and blood lactate concentration, respectively. After an initial increase, gross mechanical efficiency dropped at higher velocities, with values ranging from 4.64 to 11.26%. In conclusion, the roller ergometer, the mathematical model to determine PO and the protocol used seem to be adequate to exercise test people in a handrim wheelchair. It is feasible to apply the theoretical procedure to other roller ergometers which would allow for comparisons of exercise intensities and protocols between different devices used in exercise physiology and rehabilitation.

Adult↗

A study of lactate metabolism without tracer during passive and active postexercise recovery in humans.

Tracers have been used extensively to study lactate metabolism in humans during rest and exercise. Nevertheless, quantification of in vivo lactate kinetics as measured by lactate tracers remains controversial and new data are necessary to clarify the issue. The present study has developed a simple kinetic model which does not require labelled molecules and which yields proportional and quantitative information on lactate metabolism in humans during postexercise recovery performed at different levels of intensity. Five subjects took part in six experiments each of which began with the same strenuous exercise (StrEx; 1 min, 385 W, 110 rpm). The StrEx of each session was followed by a different intensity of recovery: passive recovery (PR) and active recoveries (AR) with power outputs of 60, 90, 120, 150 and 180 W, respectively. Blood lactate concentration was measured prior to and immediately after StrEX and regularly during the 1st h of recovery. Oxygen uptake (VO2) was measured every 30 s during the whole session. The results showed that the disappearance rate constant (ke) increases abruptly from PR [0.080 (SEM 0.004) min-1] to moderate AR [60 W: 0.189 (SEM 0.039) min-1] and decreases slowly during more intense AR [180 W: 0.125 (SEM 0.027) min-1]. The lactate apparent clearance (Cl.F-1) was calculated from the area under the lactate concentration-time curve. The Cl.F-1 increased 1.81 (SEM 0.17) fold from PR to moderate AR (60 W) and only 1.31 (SEM 0.14) from PR to the most intense AR (180 W). Using the model, the apparent lactate production (F"K0) was also calculated. The F"K0 increased regularly following a slightly curvilinear function of VO2 and was 2.61 (SEM 0.53) fold greater during the most intense AR (180 W) than during PR. Because of the lack of data concerning the size of apparent lactate distribution volume (Vd), the apparent turnover rate (Rbl) has been presented here related to Vd. The Rbl.Vd-1 increased also following a slightly curvilinear function of VO2. The Rbl.Vd-1 was 85.90 (SEM 14.42) mumol.min-1.l-1 during PR and reached 314.09 (SEM 153.95) mumol.min-1.l-1 during the most intense AR (180 W). In conclusion the model presented here does not require labelled molecules and firstly makes it possible to follow the proportional change of apparent lactate clearance and apparent lactate production during active postexercise recovery in comparison with passive recovery conditions and secondly to estimate the blood lactate turnover.

Adult↗