Search PubMed⌕ Search

Biomedical subjects

M E de Siqueira

Publications and source records attributed to M E de Siqueira.

6 recordsLinked to original sources

Urinary nickel as bioindicator of workers' Ni exposure in a galvanizing plant in Brazil.

OBJECTIVES: We measured urinary nickel (U-Ni) in ten workers (97 samples) from a galvanizing plant that uses nickel sulfate, and in ten control subjects (55 samples) to examine the association between occupational exposure to airborne Ni and Ni absorption. METHODS: Samples from the exposed group were taken before and after the work shift on 5 successive workdays. At the same time airborne Ni (A-Ni) was measured using personal samplers. Ni levels in biological material and in the airborne were determined by a graphite furnace atomic absorption spectrometry validated method. In the control group the urine samples were collected twice a day, in the before and after the work shift, on 3 successive days. RESULTS: Ni exposure low to moderate was detected in all the examined places in the plant, the airborne levels varying between 2.8 and 116.7 micrograms/m3 and the urine levels, from samples taken postshift, between 4.5 and 43.2 micrograms/g creatinine (mean 14.7 micrograms/g creatinine). Significant differences in U-Ni creatinine were seen between the exposed and control groups (Student's t test, P < or = 0.01). A significant correlation between U-Ni and A-Ni (r = 0.96; P < or = 0.001) was detected. No statistical difference was observed in U-Ni collected from exposed workers in the 5 successive days, but significant difference was observed between pre- and postshift samples. CONCLUSIONS: Urinary nickel may be used as a reliable internal dose bioindicator in biological monitoring of workers exposed to Ni sulfate in galvanizing plants regardless of the day of the workweek on which the samples are collected.

Air Pollutants, Occupational↗

[Nitrates and nitrites in homemade and industrial cheeses commercialized in the Southern region of Minas Gerais, Brazil].

The evaluation of nitrate and nitrite in homemade and industrialized cheeses commercialized in the southern region of Minas Gerais State, was the aim of this work. In Brazil, the use of these additives is permitted at maximum levels of 50 mg/kg. The basis of the previously validated method is the quantitative reduction of nitrate to nitrite through cadmium column and spectrophotometric determination after nitrite diazotation with sulphanilic acid/alpha-naphtol reagent. From all samples analyzed, 38 (88.37%) showed neither a nitrate nor nitrite detectable content; 5 samples (11.63%) presented nitrate, 4 of them being above the tolerated level and only one (2.33%) showed detectable nitrite, however below the permissible limit. The majority of samples did not show nitrate or nitrite at detectable levels. However, though probably safe from a toxicological point of view, the results can implicate an increased risk of bacteriological contamination.

Brazil↗

[Reference values for carboxyhemoglobin].

INTRODUCTION: The reference values (RV) of biological indicators are used in the interpretation of the results of such indicators in individuals occupationally exposed to chemical agents. The Brazilian Group for the Establishment of Reference Values has worked on these definitions for the purpose of establishing RVs for several bioindicators in various regions of the country. In the present study, the RV for carboxyhemoglobin (COHb) was determined for the South of Minas Gerais. MATERIAL AND METHOD: The COHb was analyzed by the Beutler and West (1984) spectrophotometric method, optimized in our laboratory. In all the samples, analyses of some biochemical and hematological parameters were made to evaluate the health condition of a population of 200 volunteer non-smokers occupationally not exposed to CO. Each individual answered a questionnaire to obtain data pertinent to the interpretation of the results. The reference values were expressed as mean values +/- standard deviation, with a 95% confidence interval, and an upper reference value. The statistical distribution of the results was made so as to enable comparisons between the results of groups of workers, rather than individual evaluations, to be made. RESULTS AND CONCLUSIONS: The mean value +/- standard deviation was 1.0% +/- 0.75; the 95% confidence interval was 0.9-1.1% and the upper reference value was 2.5%. By the t Student test (p < or = 0.05), no difference was detected between the values related to sex, age or ingestion of alcoholic beverages. The reference values obtained were close to those reported for others countries.

Adolescent↗

[Glue solvents: abuse and adverse effects on health].

In Brazil, glue sniffing has been of growing concern due to the increasing number of abusers, most of them children and teen-agers of low socio-economic level. This review article presents some aspects of this kind of abuse, with special emphasis on the deleterious effects of acute and/or chronic solvent inhalation (glue-sniffing).

Adhesives↗

Derivatization methodology for the analysis of butorphanol by gas chromatography-mass spectrometry.

Butorphanol is an opioid used as analgesic in humans and other species. In horses, it can cause locomotor stimulation at low doses. This drug is not well chromatographed by GC and so, it is necessary to transform it into a more suitable compound, which can be done by derivatization. The derivatization of a drug is used to impart volatility, masking polar groups to improve the results in gas chromatographic analysis. We have evaluated N,O-bis(trimethylsilyl)- trifluoracetamide (BSTFA)+ 1% trimethylchlorsilane (TMCS) and N-methyl-N-trimethylsilil-trifluoroacetamide (MSTFA) as derivatizing reagents for butorphanol at 30, 60 and 80 degrees C during 15, 30 and 60 min. The effects of dilution of these reagents with toluene and the evaporation before the derivatization were tested. Both reagents can be used for butorphanol derivatization and analysis and the dilution and evaporation steps did not alter the final results. The best derivatization conditions were 15 min at 80 degrees C, although 60 degrees C, although 60 degrees C during 60 min were also suitable.

Acetamides↗