Search PubMed⌕ Search

Biomedical subjects

M E Lutman

Publications and source records attributed to M E Lutman.

At least 37 records · Page 2Linked to original sources

Automatic classification of transiently evoked otoacoustic emissions using an artificial neural network.

The increasing use of transiently evoked otoacoustic emissions (TEOAE) in large neonatal hearing screening programmes makes a standardized method of response classification desirable. Until now methods have been either subjective or based on arbitrary response characteristics. This study takes an expert system approach to standardize the subjective judgements of an experienced scorer. The method that is developed comprises three stages. First, it transforms TEOAEs from waveforms in the time domain into a simplified parameter set. Second, the parameter set is classified by an artificial neural network that has been taught on a large database TEOAE waveforms and corresponding expert scores. Third, additional fuzzy logic rules automatically detect probable artefacts in the waveforms and synchronized spontaneous emission components. In this way, the knowledge of the experienced scorer is encapsulated in the expert system software and thereafter can be accessed by non-experts. Teaching and evaluation of the neural network was based on TEOAEs from a database totalling 2190 neonatal hearing screening tests. The database was divided into learning and test groups with 820 and 1370 waveforms respectively. From each recorded waveform a set of 12 parameters was calculated, representing signal static and dynamic properties. The artifical network was taught with parameter sets of only the learning groups. Reproduction of the human scorer classification by the neural net in the learning group showed a sensitivity for detecting screen fails of 99.3% (299 from 301 failed results on subjective scoring) and a specificity for detecting screen passes of 81.1% (421 of 519 pass results). To quantify the post hoc performance of the net (generalization), the test group was then presented to the network input. Sensitivity was 99.4% (474 from 477) and specificity was 87.3% (780 from 893). To check the efficiency of the classification method, a second learning group was selected out of the previous test group, and the previous learning group was used as the test group. Repeating learning and test procedures yielded 99.3% sensitivity and 80.7% specificity for reproduction, and 99.4% sensitivity and 86.7% specificity for generalization. In all respects, performance was better than for a previously optimized method based simply on cross-correlation between replicate non-linear waveforms. It is concluded that classification methods based on neural networks show promise for application to large neonatal screening programmes utilizing TEOAEs.

Artificial Intelligence↗

Educational placement of deaf children following cochlear implantation.

This study examined the educational placements, before cochlear implantation, of 121 deaf children, and the educational placements, two years after implantation, of the 48 children who had reached that stage, looking at the influence of age at implantation and duration of deafness on the placement of these children. In addition, it compared the educational placements of those given implants prior to schooling, and those given implants when already in an educational setting. Categories used were pre-school, school for the deaf, unit or resource base within a mainstream school and full-time mainstream provision. Age at implantation and duration of deafness were found to be significant predictors of placement two years after implantation. The duration of deafness of children in schools for the deaf or units was twice that of children in mainstream education. Fifty-three per cent of children who were in pre-school at the time of implantation were in mainstream schools two years after implantation, whereas only 6% of those who were already in educational placements at the time of implantation were in mainstream education. This difference was statistically significant. The results indicate that children who are given implants early, before an educational decision has been made, are more likely to go to mainstream schools than those given implants when already in an educational setting.

Adolescent↗

Anomalous screening outcomes from click-evoked otoacoustic emissions and auditory brainstem response tests.

Transiently evoked otoacoustic emissions (TEOAE) and auditory brainstem response (ABR) tests were used in parallel to screen 862 neonates with risk factors for hearing loss. Seven neonates (0.81%) passed on TEOAE screen yet failed on ABR in one ear (six neonates) or both ears (one neonate). This combination of results has been termed 'anomalous'. Examination of audiometric results obtained on follow-up shows that in one ear of one neonate the result was consistent with the later confirmed audiogram shape. The explanation for the anomalous results in the remaining ears is unclear although neural maturation and the effects of hyperbilirubinaemia are possibilities. There were no instances of progressive or retrocochlear hearing loss identified. None of the seven neonates had better ear hearing loss of > or = 40 dB on long term follow-up.

Acoustic Stimulation↗

Field sensitivity of targeted neonatal hearing screening by transient-evoked otoacoustic emissions.

OBJECTIVE: Population ascertainment of children having bilateral moderate to profound hearing impairment was undertaken to find out how many had passed (false negatives) and how many had failed (true negatives) a neonatal screening test based on transient-evoked otoacoustic emissions (TEOAE). DESIGN: Neonatal screening using a purpose-built TEOAE instrument was undertaken in neonates, at eight hospitals in districts distributed around the United Kingdom starting in 1988. Screening was targeted on neonates at risk of hearing impairment. A total of 7500 babies had been tested by the end of 1995. Searching of audiological records in the districts completed at the end of 1995 ascertained 218 children born between January 1988 and December 1993 who had hearing threshold levels in both ears of 50 dB or more, averaged over the speech frequencies 0.5, 1, 2, and 4 kHz. Of those, 47 had completed the neonatal TEOAE screening test. Retrospective examination of their TEOAE records indicated whether they had passed or failed the screening test. RESULTS: Eleven of the 47 had passed the screening test, although two of those had documented acquired hearing impairment occurring after screening. Disregarding those two cases leaves nine false negatives out of 45, giving a sensitivity estimate of 80% (36 divided by 45). In two of the nine cases, there was documented evidence of progression, one of whom had a family history of progressive hearing loss. CONCLUSIONS: Targeted neonatal hearing screening programs based on TEOAE can expect to identify hearing impairment in approximately 80% of babies screened. The cause of false negatives is a matter for conjecture. There may be several reasons: the test may give an incorrect result, there may be a later acquired hearing impairment, or there may be a progressive hearing loss of unknown origin. Passing a neonatal screening test is not a valid reason to forego further surveillance, or to disregard parental suspicion of hearing impairment.

Acoustic Stimulation↗

The predictive value of measures of preverbal communicative behaviors in young deaf children with cochlear implants.

OBJECTIVE: To determine whether measures of early communicative behavior in young children obtained within the first year after implantation could predict speech and language skills measured 3 yr after implantation. DESIGN: An unselected sample of 17 children receiving multichannel cochlear implants under the age of 5 yr were monitored over a 3 yr period. During the first year after implantation, the development of early communicative behavior was measured at intervals using an established video analysis technique. Three years after implantation, four outcome measures were taken: the IOWA closed-set sentence test, a measure of continuous discourse tracking ability, a rating of ability to use the telephone and a global rating of auditory performance. RESULTS: There was a significant correlation between the video analysis measure taken at the 12 mo interval, specifically the extent of auditory and vocal behaviors, and three of the outcomes obtained at the 3 yr interval: both performance-based measures and the telephone rating. When the four outcomes were aggregated to form a composite measure, the correlation was highly significant. There was no significant correlation between the composite measure and the video analysis measures obtained earlier than the 12 mo interval. CONCLUSION: Development of a predominantly auditory and vocal style of early communicative behavior is predictive of relatively high levels of skill on speech and language tasks measured 2 yr later.

Child, Preschool↗

Are normal hearing thresholds a sufficient condition for click-evoked otoacoustic emissions?

Transiently evolked otoacoustic emissions (TEOAE) have been reported in several studies as absent in a small minority of normal ears. Other studies have reported TEOAEs in all normal ears. Differences between studies may arise directly from criteria for TEOAE identification, criteria for selection of normals, or statistically due to limited sample sizes. In order to understand and model cochlear processes involved in TEOAE generation, it needs to be known whether the presence of normal hearing leads automatically to generation of TEOAEs. The present study set out to establish in a large sample if any ears could be found that lacked TEOAEs despite normal hearing threshold levels (HTL). A total of 397 ears from highly cooperative adult subjects were examined under laboratory conditions. Using cross correlation between replicate nonlinear waveforms as the criterion, TEOAEs were present in 99.2% of the sample (lower CI 98.1%). However, careful visual assessment of the recorded waveforms for the remaining ears did not unequivocally show absence of TEOAE characteristics in any ear with normal HTLs. While TEOAE strength varies widely among ears, no clear evidence was found to show that TEOAEs can be absent when HTLs are normal.

Acoustic Stimulation↗

Self-rated hearing disability in candidates for cochlear implants.

A previous scheme for quantification of hearing disability based on self-rating required extrapolation towards the upper end of the range due to lack of data from severely and profoundly impaired subjects. Suitable data have become available more recently from the UK programme evaluating cochlear implantation, thereby providing self-ratings by 465 people with 1-2-3-kHz average hearing threshold levels of 95 dB or greater. The ratings obtained fit the previous extrapolation extremely well. The scheme, therefore, can be applied with confidence to people throughout the range of hearing impairment.

Auditory Threshold↗

Efficiency of tests used to screen for cerebello-pontine angle tumours: a prospective study.

With increasing use of imaging in the investigation of cerebello-pontine angle (CPA) tumours, the role of audio-vestibular and electrophysiological testing has changed. Field performance data on the efficiencies of these tests to screen for CPA tumours are lacking, but must be known to choose an appropriate testing strategy. A prospective observational study of 237 patients attending a neuro-otology clinic for audio-vestibular investigation was carried out. The aim was to provide field performance data on which to base an effective protocol to screen for CPA tumours. All patients presenting at the ENT department and meeting any of the following criteria were referred to the neuro-otology clinic and included in the study: (1) asymmetrical sensorineural hearing loss, (2) unexplained asymmetrical tinnitus with normal bearing thresholds, (3) unilateral bearing difficulties with normal hearing thresholds and (4) other neurological indications. In addition to audio-vestibular and auditory brainstem response (ABR) investigation, every patient underwent computed tomography (CT), with magnetic resonance imaging (MRI) in cases having marginal results on CT, to exclude or confirm the presence of a tumour. Pass or fail on each test was based on a priori criteria from other studies. Eighteen patients were found to have CPA tumours. ABR testing was the only effective procedure for screening, but had some limitations. A contingent protocol using ABR in all cases except those with asymmetrical tinnitus and normal bearing thresholds, those with severe hearing loss, and those with neurological signs, was retrospectively defined: the exceptions would go straight to CT. This protocol would have missed two of the 18 tumour patients. CT scanning alone would have missed one small intra-canalicular tumour, which was picked up on MRI triggered by abnormal ABR. Based on the results from the present study we conclude there is no effective screening protocol for detecting CPA tumours, as MRI scanning with gadolinium enhancement will identify virtually all tumours. Where MRI is available but waiting lists are long, the described strategy using ABR to select priority referrals for MRI scanning is recommended.

Adult↗

Categories of Auditory Performance.

Categories of Auditory Performance (CAP) is an index consisting of eight performance categories arranged in order of increasing difficulty. It has been used to categorize 53 children who had been deafened below the age of 3. The children were assessed by means of the CAP before implantation, and over the following 3 years. Before implantation, only 2 of the children showed awareness of environmental sounds; immediately after initial tuning, all children showed awareness of environmental sounds, and 50% showed awareness of speech sounds. Their auditory receptive abilities gradually developed over the 3-year period, and by the 3-year assessment interval, 80% were understanding phrases without lipreading, and 40% were understanding conversation. Using these data, we predict that 90% of such children will understand conversation without lipreading 5 years after initial tuning.

Auditory Perception↗

Early communicative behavior in young children receiving cochlear implants: factor analysis of turn-taking and gaze orientation.

Early communicative behaviors in young children can be analyzed quantitatively from recordings of interactions between the child and a known adult. Our previous work has shown that the development of such behaviors differs markedly between profoundly deaf young children 1) able to make proficient use of hearing aids or having cochlear implants and 2) unable to make proficient use of hearing aids. The former take turns mainly by vocalization, whereas the latter take turns mainly by gesture. The present study set out to examine whether these contrasts in behavior demonstrated between groups are also observable within a group of young children having cochlear implants, and to examine their development over the first year of implantation. In the 20 children with complete data at the 12-month interval, two clear factors were identified that explained 72% of the variance. These can be labeled as 1) vocal-auditory turn-taking and 2) gaze orientation. All measures of communicative behavior, other than autonomy, showed significant development over the 12 months following implantation, although the observed increase in eye contact was small. No differences could be demonstrated between children with congenital and acquired deafness. It is concluded that the technique based on video analysis is sensitive to changes in early communicative behavior in the year after implantation. Deviations from the expected pattern may indicate inappropriate processor adjustment, device malfunction, or inadequate support.

Child↗

Comparison of early communicative behavior in young children with cochlear implants and with hearing aids.

Analysis of preverbal behaviors, which are the natural precursors of language development, was performed in three groups of young children with severe/profound hearing impairments, based on video recordings of interactions with a known adult. All groups were matched for age at assessment. One group of nine children had Nucleus multichannel cochlear implants with the MSP sound processor, whereas the other two groups of nine children each used conventional hearing aids. The first hearing aid group had unaided hearing threshold levels averaging 101 dB and were proficient users; the second aided group had hearing threshold levels averaging 114 dB and were poor users. Over the assessment period lasting 12 mo, starting at implantation or entry to nursery school according to group, implantees and proficient hearing aid users developed a strongly vocal/auditory style of communicative behavior, especially the implantees. This contrasted with a strongly visual/gestural style developed by the poor hearing aid users. It is concluded that implantees develop their early communicative behavior along lines that are similar to proficient hearing aid users, but more rapidly and more strongly in the vocal/auditory direction.

Auditory Perception↗

Transiently evoked otoacoustic emissions in patients with cerebellopontine angle tumors.

Transiently evoked otoacoustic emissions (TEOAE) are generally present in ears with normal hearing, but absent in ears with cochlear hearing losses greater than 25-30 dB; they have been demonstrated previously in a few ears with retrocochlear hearing losses greater than 30 dB across the frequency range 0.25-8 kHz. To assess the potential of TEOAEs in the diagnosis of retrocochlear hearing losses, measurements were made in 45 patients with retrocochler disorder attributable to confirmed cerebellopontine angle (CPA) tumors. Transiently evoked OAEs elicited by click stimuli were recordable in 21 (47%) of the ears with tumor. Nine of these had normal hearing at two or more octave frequencies across the range 0.5-4 kHz and so might be expected to have TEOAEs regardless of the type of disorder. The other 12 ears had recordable TEOAEs despite hearing threshold levels greater than 25 dB between 0.5 and 4 kHz. The absence of TEOAEs in the remaining 24 ears (53%) indicated a significant outer hair cell component to the hearing loss. Neither age nor sex were significant factors in the occurrence of TEOAEs. The TEOAE test gives useful differential diagnostic information when emissions are recorded in ears having hearing threshold levels greater than 25 dB at all frequencies. In such ears there is relatively normal cochlear function at the level of the outer hair cells, at least at some frequencies, and hence, by inference, there must be a retrocochlear disorder.

Adolescent↗

Reliable identification of click-evoked otoacoustic emissions using signal-processing techniques.

As neonatal hearing screening programmes based on click-evolved otoacoustic emissions (CEOAEs) become more common, there is a need for automatic scoring methods to classify responses systematically. Such methods must guard rigorously against errors that would pass a baby who would otherwise fail and be referred for further diagnostic testing. Preliminary analysis of a wide range of CEOAE waveform characteristics from adult and neonatal ears suggested that the most reliable measure on which to base an automatic method was the cross-correlation coefficient between replicate non-linear components. Further analysis of recordings from 2049 ears of 1102 neonates in neonatal intensive care units indicated that a cross-correlation coefficient greater than 0.5 was an appropriate criterion to distinguish a pass from a fail, with the following two provisos. The waveforms should be high-pass filtered to remove random low-frequency components before calculating the cross-correlation coefficient. The cross-correlation coefficient should relate to the time period from 6-16 ms after click onset. Using this method, 90% of recordings were automatically classified in agreement with a proven method of visual scoring. Only one ear without evidence of otoacoustic emission was passed by the automatic scoring method.

Acoustic Stimulation↗

Late partial recovery from meningitic deafness after cochlear implantation: a case study.

A child with well-documented total bilateral deafness as a result of meningitis contracted at the age of 2 years and 8 months demonstrated remarkably delayed recovery of hearing 14 months later. In the meantime cochlear implantation had been performed. Hearing returned partially in the nonimplanted ear and also in the ear implanted with a long multi-electrode intracochlear array, giving unaided thresholds at frequencies from 0.5 to 4 kHz of 60-80 dB and 90-105 dB, respectively. Despite this rare occurrence, it is concluded that a delay until 6 months after meningitis before implantation is appropriate to detect most cases of spontaneous recovery of hearing.

Auditory Threshold↗

Lack of association between otoacoustic emissions and hearing difficulty in subjects with normal hearing thresholds.

Evoked otoacoustic emissions (EOAE) are a sensitive indicator of subtle cochlear damage and hence might explain why some people complain of excessive difficulty understanding speech in a background of noise, despite having normal hearing thresholds. This phenomenon has been termed "Obscure Auditory Dysfunction" (OAD). Recorded EOAE waveforms from a group of 50 OAD patients were compared with those from a group of 50 matched controls. No significant difference could be found between the two groups across a range of objective and subjective descriptors of the EOAEs. Any cochlear component of OAD does not appear to affect the function of the outer hair cells sufficiently to modify EOAEs materially.

Auditory Threshold↗

The feasibility of using oto-acoustic emissions to monitor cochlear function during acoustic neuroma surgery.

The feasibility of using evoked oto-acoustic emission (EOAE) measurement for intra-operative monitoring of cochlear function was assessed during removal of an acoustic neuroma in a 53-year-old woman with normal hearing on the operated side prior to surgery. The high level of noise in the operating theatre was the only material problem encountered and this was not sufficient to prevent recording of identifiable waveforms. During manipulation of the brainstem, damage to the cochlea was indicated by an increase in EOAE latency and its eventual disappearance. A total hearing loss in the operated ear was revealed after surgery. Monitoring cochlear function with EOAEs is probably best considered at present as an adjunct to auditory brainstem response monitoring of the composite cochlea and eighth nerve, thus providing differential information.

Cochlea↗

Quantification of hearing disability for medicolegal purposes based on self-rating.

Current practice for medicolegal assessment of individuals entails the use of an impairment measure obtained from average hearing threshold levels as a surrogate for hearing disability, and conversion of the surrogate to disability via a formula. Several different formulae are in use, but none is based explicitly on experimental data. To address this lack of empirical foundation in the assessment process, numerical self-ratings of hearing ability by 2058 subjects with a wide range of hearing threshold levels who had taken part in the National Study of Hearing in the UK were analysed to examine their relation to average hearing threshold level. The relation between self-rated hearing disability (the complement of self-rated hearing ability) and hearing threshold level was found to be sigmoid in form, and could be closely modelled by a modified Gompertz function. Functions for the median, upper quartile and lower quartile disability ratings with hearing threshold level are presented in graphical, parametric and tabular form. The median function gives a quantitative foundation for medicolegal assessments.

Adolescent↗