Search PubMed⌕ Search

Biomedical subjects

M E Houghton

Publications and source records attributed to M E Houghton.

5 recordsLinked to original sources

Increased lipophilicity and subsequent cell partitioning decrease passive transcellular diffusion of novel, highly lipophilic antioxidants.

Oxidative stress is considered a cause or propagator of acute and chronic disorders of the central nervous system. Novel 2, 4-diamino-pyrrolo[2,3-d]pyrimidines are potent inhibitors of iron-dependent lipid peroxidation, are cytoprotective in cell culture models of oxidative injury, and are neuroprotective in brain injury and ischemia models. The selection of lead candidates from this series required that they reach target cells deep within brain tissue in efficacious amounts after oral dosing. A homologous series of 26 highly lipophilic pyrrolopyrimidines was examined using cultured cell monolayers to understand the structure-permeability relationship and to use this information to predict brain penetration and residence time. Pyrrolopyrimidines were shown to be a more permeable structural class of membrane-interactive antioxidants where transepithelial permeability was inversely related to lipophilicity or to cell partitioning. Pyrrole substitutions influence cell partitioning where bulky hydrophobic groups increased partitioning and decreased permeability and smaller hydrophobic groups and more hydrophilic groups, especially those capable of weak hydrogen bonding, decreased partitioning, and increased permeability. Transmonolayer diffusion for these membrane-interactive antioxidants was limited mostly by desorption from the receiver-side membrane into the buffer. Thus, in this case, these in vitro cell monolayer models do not adequately mimic the in vivo situation by underestimating in vivo bioavailability of highly lipophilic compounds unless acceptors, such as serum proteins, are added to the receiving buffer.

Animals↗

The effect of moisture on the mechanical and powder flow properties of microcrystalline cellulose.

PURPOSE: This study determined the effects of moisture on the mechanical and powder flow properties of microcrystalline cellulose. METHODS: A variety of mechanical properties were determined as a function of solid fraction at moisture levels ranging from 0 to 12.2% and included: compaction pressure required to form a compact, dynamic indentation hardness, quasi-static indentation hardness, tensile strength, best case and worst case Bonding Index, Brittle Fracture Index, Strain Index, Compressibility Index and shear cell index. RESULTS: Significant changes were observed as the moisture level of microcrystalline cellulose increased. The compaction pressure required to produce a compact at a solid fraction of 0.6 decreased with increasing moisture content. The permanent deformation pressure and tensile strength of compacts were observed to be relatively independent of moisture content below about 5% moisture and then decrease as the moisture content increased further. The "best case" Bonding Index was also observed to be independent of moisture content below 5% and then increase with increasing moisture. The Brittle Fracture Index and "worst case" Bonding Index, however, did not appear to be affected by changes in moisture content. Powder flow was shown to decrease with increasing moisture content. CONCLUSIONS: These mechanical property data are consistent with the hypothesis that water acts as a plasticizer and influences the mechanical properties of microcrystalline cellulose. At moisture levels above about 5%, the material exhibits significant changes consistent with a transition from the glassy state to the rubbery state.

Cellulose↗

Microscopic characterization of particle size and shape: an inexpensive and versatile method.

A variety of methods exists for measuring individual particle dimensions as a means of characterizing particle size, size distribution, and shape. The equipment described in this report belongs to the class of semiautomatic non-TV-interfaced analyzers. Unlike many existing image analysis systems, three-dimensional form measurements and texture data for the calculation of particle size and shape parameters can be determined easily and directly from each particle profile using this system. Essentially all data are collected directly from the particle and recorded by the computer with no intermediate steps. Much of the system consists of general-purpose and relatively inexpensive, commercially available hardware and software. Using this method, particle size, size distribution, and qualitative or quantitative shape information can easily and rapidly be obtained simultaneously. Particle length and width characterization, for example, can take less than 15 min. The equipment is versatile and flexible in measurements and calculations. The size and shape parameters to be measured are determined by the researcher and not the instrument. The ease with which this information can be obtained from small samples early in the development process makes it a valuable tool for the formulator.

Chemistry, Pharmaceutical↗

Scanning electron microscopy of chronically stimulated platinum intracochlear electrodes.

Platinum electrodes were examined for evidence of corrosion using a scanning electron microscope (SEM). In vivo electrodes, stimulated using charge-balanced biphasic pulses for periods of up to 2000 h at charge densities of 0.18-0.32 microC mm-2 geom. per phase, were compared with in vitro electrodes stimulated in inorganic saline using similar stimulus parameters, and with in vivo control electrodes. The in vitro stimulated electrodes showed evidence of platinum corrosion at high charge density and aggregate charge injection. Significantly, the in vivo stimulated electrodes showed no evidence of stimulus induced corrosion. Indeed, their surfaces were similar to the in vivo control electrodes. In vitro electrochemical studies have demonstrated that proteins play a significant role in the inhibition of platinum dissolution: the present study has demonstrated an inhibitory effect in vivo. This may be due to the presence of proteins.

Animals↗

Implanted material tolerance studies for a multiple-channel cochlear prosthesis.

We have performed a number of temporal bone and animal studies in order to evaluate the histopathological effects of intracochlear electrode implantation and chronic electrical stimulation. Our results indicate that (a) the insertion of a free-fit scala tympani array results in minimal damage to the membranous labyrinth; (b) the materials used in the electrode array evoke mild tissue reactions when implanted subcutaneously, in muscle, or within the scala tympani; (c) intracochlear electrical stimulation for periods of 500 to 2000 hours, using carefully controlled biphasic pulses, does not adversely affect the population or neural activity of the primary auditory neurones; (d) labyrinthine infection severely reduces the number of viable spiral ganglion cells; (e) an adequate fibrous tissue seal of the round window can prevent the spread of infection from the bulla to the implanted cochlea in cats, following inoculation of the bulla cavity with bacteria; (f) bone growth is not associated with electrical stimulation per se; (g) the electrode arrays show minimal platinum dissolution and no apparent degradation of the Silastic carrier following periods of long-term intracochlear electrical stimulation.