M Drangova

Publications and source records attributed to M Drangova.

At least 19 recordsLinked to original sources

Application of dynamic computed tomography for measurements of local aortic elastic modulus.

A novel computed tomographic (CT) technique used for the instantaneous measurement of the dynamic elastic modulus of intact excised porcine aortic vessels subjected to physiological pressure waveforms is described. This system was comprised of a high resolution X-ray image intensifier based computed tomographic system with limiting spatial resolution of 3.2 mm-1 (for a 40 mm field of view) and a computer-controlled flow simulator. Utilising cardiac gating and computer control, a time-resolved sequence of 1 mm thick axial tomographic slices was obtained for porcine aortic specimens during one simulated cardiac cycle. With an image acquisition sampling interval of 16.5 ms, the time sequences of CT slices were able to quantify the expansion and contraction of the aortic wall during each phase of the cardiac cycle. Through superficial tagging of the adventitial surface of the specimens with wire markers, measurement of wall strain in specific circumferential sectors and subsequent calculations of localised dynamic elastic modulus were possible. The precision of circumferential measurements made from the CT images utilising a cluster-growing segmentation technique was approximately +/- 0.25 mm and allowed determination of the dynamic elastic modulus E(dyn) with a precision of +/- 8 kPa. Dynamic elastic modulus was resolved as a function of the harmonics of the physiological pressure waveform and as a function of the angular position around the vessel circumference. Application of this dynamic CT (DCT) technique to seven porcine thoracic aortic specimens produced a circumferential average (over all frequency components) E(dyn) of 373 +/- 29 kPa. This value was not statistically different (p < 0.05) from the values of 430 +/- 77 and 390 +/- 47 kPa obtained by uniaxial tensile testing and volumetric measurements respectively.

Animals

Quantitative angiographic blood-flow measurement using pulsed intra-arterial injection.

A technique for quantitative blood-flow measurement using a novel pulsed injection of radiographic contrast agent is reported. A pressurized source of contrast agent is interrupted by a rotary valve at rates ranging from 1 to 30 Hz, producing well-defined boli at the end of a catheter. The position of these boli can be recorded by a digital radiographic system and analyzed by one of several previously reported techniques, to produce quantitative measurements of blood velocity and flow rate throughout the cardiac cycle. The contrast-agent flow wave form produced by the pulsed injector has been measured with an electromagnetic flow meter, for driving pressures ranging from 600 to 1500 kPa. Excellent modulation of the contrast agent is observed for injection frequencies up to 20 Hz, through catheters up to 100 cm in length. Preliminary in vitro angiographic flow measurements have been performed using an x-ray image intensifier, coupled to a linear photodiode array as the digital detector. Both constant flow and pulsatile human blood-flow wave forms were simulated within a 6.4-mm-diam straight tube and monitored with an electromagnetic flow meter. These experiments indicate that the pulsed injector can be used to provide estimates of arterial blood flow over the entire cardiac cycle (including reverse flow), to within about +/-11%, following injection of less than 10 ml of iodinated contrast agent.

Angiography, Digital Subtraction

In vitro verification of myocardial motion tracking from phase-contrast velocity data.

The ability to track motion from cine phase-contrast (PC) magnetic resonance (MR) velocity measurements was investigated using an in vitro model. A computer-controlled deformable phantom was used for the characterization of the accuracy and precision of the forward-backward and the compensated Fourier integration techniques. Trajectory accuracy is limited by temporal resolution when the forward-backward technique is used. With this technique the extent of the calculated trajectories is underestimated by an amount related to the motion period and the sequence repetition time, because of the band-limiting caused in the cine interpolation step. When the compensated Fourier integration technique is used, trajectory accuracy is independent of temporal resolution and is better than 1 mm for excursions of less than 15 mm, which are comparable to those observed in the myocardium. Measurement precision is dominated by the artifact level in the phase-contrast images. If no artifacts are present precision is limited by the inherent signal-to-noise ratio of the images. In the presence of artifacts, similar in magnitude to those observed in vivo, the reproducibility of tracking a 2.2 x 2.2 mm2 region of interest is better than 0.5 mm. When the Fourier integration technique is used, the improved accuracy is accompanied by a reduction in precision. We verified that tracking three-dimensional (3D) motion from velocity measurements of a single slice can lead to underestimations of the trajectory if there is a through-plane component of the motion that is not truly represented by the measured velocities. This underestimation can be overcome if volumetric cine phase-contrast velocity data are acquired and full three-dimensional analysis is performed.

Artifacts

Estimation of deformation gradient and strain from cine-PC velocity data.

Phase contrast magnetic resonance imaging (MRI) can provide in vivo myocardial velocity field measurements. These data allow densely spaced material points to be tracked throughout the whole heart cycle using, for example, the Fourier tracking algorithm. To process the tracking results for myocardial deformation and strain quantification, we developed a method that is based on fitting the tracking results to an appropriate local deformation model. We further analyzed the accuracy and precision of the method and provided performance predictions for several local models. In order to validate the method and the theoretical performance analysis, we conducted controlled computer simulations and a phantom study. The results agreed well with expectations. Human heart data were also acquired and analyzed, and provided encouraging results. At the signal-to-noise ratio (SNR) level and spatial resolution expected in clinical settings, the study predicts strain quantification accuracy and precision that may allow the technique to become a practical and powerful noninvasive approach for the study of cardiac function, although clinically acceptable data acquisition strategies for three-dimensional (3-D) data are still a challenge.

Aortic Stenosis, Subvalvular

Artifacts and signal loss due to flow in the presence of B(o) inhomogeneity.

An in vitro study was performed to investigate the effects of B(o) inhomogeneity on magnetic resonance images of flow. Controlled inhomogeneity gradients (Gi) were applied and the magnitude of the artifacts produced was quantified for different echo delay times (TE). Both steady and pulsatile flows were examined. In the presence of an inhomogeneity gradient, signal loss is apparent if the flow is pulsatile and/or if the slice thickness is large. The signal loss increases with increasing TE and Gi. With pulsatile flow, ghosting artifacts are also generated. These increase in intensity with increasing TE and Gi. In vivo, field inhomogeneity due to susceptibility variations is large enough to produce these effects. Representative time-of-flight images obtained of a normal volunteer with two different TEs demonstrate the effect in vivo. Flow-related signal loss and artifacts, therefore, increase with increasing TE independent of the moments of the applied gradients.

Artifacts

Decomposition of inflow and blood oxygen level-dependent (BOLD) effects with dual-echo spiral gradient-recalled echo (GRE) fMRI.

Image contrast with gradient-recalled echo sequences (GRE) used for fMRI can have both blood oxygen level-dependent (BOLD) and inflow components, and the latter is often undesirable. A dual-echo technique can be used to differentiate these mechanisms, because modulation of signal from inflow is common to both echoes, whereas susceptibility and diffusion-related signal losses are larger in the second echo. An efficient dual-echo interleaved spiral sequence was developed for use with a conventional scanner. It uses a k-space trajectory that spirals out from the origin while the first echo is collected, then spirals back in while collecting the second echo. Decomposition of the data provides separate images of the inflow and T2-weighted components. Results demonstrate the decomposition with phantom experiments and with photic stimulation in normal volunteers.

Brain Mapping

Fourier tracking of myocardial motion using cine-PC data.

A closed-form integration method is derived and analyzed for computing motion trajectories from velocity field data, particularly as measured by phase contrast (PC) cine MR imaging. By modeling periodic motion as composed of Fourier harmonics and integrating the material velocity of the tracked point in the frequency domain, this method gives an unbiased trajectory estimate in the presence of white measurement noise and eddy current effects. When applied to cine PC data, the method can incorporate compensation for the frequency response of the cine interpolation, offering a further improvement on the tracking accuracy. In simulation and phantom studies, the estimated trajectories were in excellent agreement with the true trajectories. Encouraging results have also been obtained on data from volunteers.

Algorithms

A laboratory CT scanner for dynamic imaging.

A high-resolution laboratory CT scanner has been developed for imaging objects undergoing periodic motion. The scanner comprises an x-ray image intensifier, optically coupled to a linear photodiode array. Gated time-evolved projections of a single slice of the moving object are acquired, reformatted, and reconstructed. The resulting series of CT images shows the object at different phases of its motion cycle. The scanner has an adjustable field of view (FOV) and the resolution can be as high as 3.2 mm-1 (for the 40-mm FOV). The spatial resolution depends on the inherent resolution of the scanner and on the object's velocity. For objects moving at 1 cm s-1, the spatial resolution is reduced by 9% in the direction of motion. The signal intensity in the reconstructed image is linear for materials with attenuation coefficients as high as 1.5 cm-1 (for a 90-kVp x-ray beam), with an average accuracy of +/- 0.02 cm-1. The average accuracy of circumference measurements made from the CT images is +/- 0.3 mm. Lastly, an application of this dynamic CT scanner to imaging excised human arterial specimens under simulated physiological pressure conditions is presented as an example.

Aged

Elasticity and geometry measurements of vascular specimens using a high-resolution laboratory CT scanner.

Vascular diseases are frequently associated with changes in the mechanical properties of the arterial wall. Existing techniques for studying arterial geometry and mechanical properties in vitro are often destructive, since they involve sectioning of the specimen into strips, or provide average measurements of the mechanical properties over the volume of intact specimens. We developed a high-resolution computed tomography (CT) scanner for in vitro studies of arterial geometry and static elastic properties. The x-ray image intensifier based system can acquire single transverse images, or a volume image, with 2 mm-1 resolution. Images were obtained through an intact abdominal aortic aneurysm at five pressures. The incremental circumferential Young's modulus E(inc) was calculated from the internal and external circumferences, and at physiological pressures E(inc) of the aneurysm was found to be 275 times greater than that of the normal aorta proximal to it. A volume image of the specimen provided landmarks that allowed histological sections to be obtained at locations coincident with those where the elasticity was measured. The histological analysis revealed a sixfold decrease in elastin content in the aneurysm, compared to the normal aorta. We have demonstrated that the static mechanical properties and geometry of vascular specimens can be quantified in vitro with the new high-resolution CT scanner and can be compared subsequently with histological analysis to provide further insight into the understanding of atherogenesis.

Aged

Computer-controlled positive displacement pump for physiological flow simulation.

A computer-controlled pump for use both in the study of vascular haemodynamics and in the calibration of clinical devices which measure blood flow is designed. The novel design of this pump incorporates two rack-mounted pistons, driven into opposing cylinders by a micro-stepping motor. This approach allows the production of nearly uninterrupted steady flow, as well as a variety of pulsatile waveforms, including waveforms with reverse flow. The capabilities of this pump to produce steady flow from 0.1 to 60 ml s-1, as well as sinusoidal flow and physiological flow, such as that found in the common femoral and common carotid arteries are demonstrated. Cycle-to-cycle reproducibility is very good, with an average variation of 0.1 ml s-1 over thousands of cycles.

Arteries

Stereotactic surgical planning with magnetic resonance imaging, digital subtraction angiography and computed tomography.

Over the past 2 years at the Montreal Neurological Institute and Hospital, we have evolved an integrated environment for the planning of stereotactic procedures, based on images from magnetic resonance imaging, digital subtraction angiography and computed tomography modalities. These procedures rely on fiducial marker sets which are attached to our 'OBT' stereotactic frame, and which may be recognized in the images. The software package is modular and operates in both minicomputer (PDP-11 and VAX) and IBM personal computer environments. In addition to routine tasks for stereotactic planning, the package also supports dosimetry planning for stereotactic radiosurgery.

Brain

Computer-controlled flow simulator for MR flow studies.

A novel computer-controlled flow simulator for use in magnetic resonance (MR) flow experiments was evaluated. The accuracy in constant-flow mode was better than 1%. The accuracy in pulsatile-flow mode was found to be dependent on the interconnecting tubing. The short-term and long-term reproducibilities of pulsatile waveforms were less than or equal to 0.4 mL/sec (1 standard deviation). Increased response times due to the lengths of tubing required in MR flow experiments were surmounted by using a modified tubing configuration and precompensated waveforms. Piston reversal was found not to cause major difficulties in MR flow experiments.

Blood Circulation

Tracking of cyclic motion with phase-contrast cine MR velocity data.

A method of computing trajectories of objects by using velocity data, particularly as acquired with phase-contrast magnetic resonance (MR) imaging, is presented. Starting from a specified location at one time point, the method recursively estimates the trajectory. The effects of measurement noise and eddy current-induced velocity offsets are analyzed. When the motion is periodic, trajectories can be computed by integrating in both the forward and backward temporal directions, and a linear combination of these trajectories minimizes the effect of velocity offsets and maximizes the precision of the combined trajectory. For representative acquisition parameters and signal-to-noise ratios, the limitations due to measurement noise are acceptable. In a phantom with reciprocal rotation, the measured and true trajectories agreed to within 3.3%. Sample trajectory estimates of human myocardial regions are encouraging.

Heart

Physiologic motion phantom for MRI applications.

To address the need for a complex physiologic motion phantom for use in MR applications, such as the verification of techniques for measuring myocardial motion dynamics and motion insensitive pulse sequences, a computer-controlled motion phantom has been designed. The phantom, which consists of a deformable silicone gel annulus mounted on a translation stage, can undergo a range of bulk motions and deformations. Available motions include bulk rotation and translation, rotational shear, axial shear, and combinations of some or all of these motions. In this paper, the capability of the phantom to produce accurate constant and time-varying waveforms is demonstrated. In the current implementation, peak linear translation and rotation rates are 175 mm s-1 and 10 rad s-1, respectively. Cycle-to-cycle reproducibility is excellent, with variations of less than .003 radians over the period of hours while undergoing rotational shear. The phantom has been designed in a flexible fashion so that various test objects can be scanned while undergoing bulk translation and can be adapted to produce different deformations.

Hemodynamics

Effect of artifacts due to flowing blood on the reproducibility of phase-contrast measurements of myocardial motion.

The reproducibility of myocardial motion trajectories calculated from cine phase-contrast (PC) velocity data is reduced by artifacts due to the inconsistent motion of intracardiac blood. Spatial presaturation reduces these artifacts but requires a longer sequence TR, with a potentially negative effect on trajectory accuracy and reproducibility. We investigated the effect of spatial presaturation on trajectory reproducibility. A mid-ventricular transaxial slice was imaged in five normal volunteers. The same slice was imaged three times each with sequences using spatial presaturation or not. Because the most serious artifacts originate in the heart chambers and propagate in the phase-encoded direction, myocardial regions that were in line with the heart chambers (in the phase-encode direction) had the highest artifact level in the scans without spatial presaturation. The reproducibility of trajectories for regions placed in these areas (the anterior wall, septum and posterior wall in the transaxial scans with phase encoding in the anterior-posterior direction) improved by a factor of two when presaturation was used (P < .001). In areas that were not in line with the heart chambers (eg, the anterior aspect of the lateral wall in the transaxial scans), the effect of presaturation was not significant. These results correlate well with the measured reduction in artifact level. The reproducibility of myocardial motion trajectories over large areas of the heart is improved to approximately 1 mm when presaturation is used. Therefore, use of presaturation is recommended for myocardial motion studies using cine PC velocity data.

Adult

Optical factors affecting the detective quantum efficiency of radiographic screens.

Parameters related to the detective quantum efficiency (DQE) of several representative screens of different thicknesses, phosphor grain sizes, and optical properties were measured by the scintillation spectrum method, using monoenergetic x rays produced from x-ray fluorescence. The experimental results, including those for spectral shape and average light energies (EA) emitted, are compared with conventional theories of the operation of screens. It was hoped that this would vindicate the theory of the effect of optical properties and so permit the simple calculation of all parameters related to DQE from standard x-ray attenuation tables. Rather more substantial energy-dependent deviations of EA are found than was previously realized, which preliminary analysis suggests are due to both optical effects and photoelectron escape. We conclude that although DQE for a single energy can be calculated by simplified methods to within +/- 10%, the effective DQE when polyenergetic beams are used is much less accurately estimated and requires a fuller theoretical treatment.

Filtration

Measurement of the spatial Wiener spectrum of nonstorage imaging devices.

All previous methods for measuring image noise spectra require a noise realization, a static image, typified as a photograph which can be scanned to create the Wiener spectrum. We wished to analyze the spatial noise power spectrum at the output phosphor of a continuously irradiated imaging device, an x-ray image intensifier (XRII), which is incapable of image storage and thus the image is continually changing as a function of both time and space. Our new method utilizes a pair of slits to measure the relative Wiener spectrum of the temporally changing components of the image (i.e., x-ray quantum and XRII gain noises). By measuring the modulation transfer function and the Wiener spectrum of the same XRII on the same apparatus it was possible to demonstrate the spatial frequency dependence of the detective quantum efficiency. Adaptations of the method should permit the measurement of Wiener spectra of fluoroscopic television systems directly from the TV monitor.

Fourier Analysis

A modified x-ray image intensifier with continuously variable field of view: resolution considerations.

A conventional x-ray image intensifier (XRII) has been modified to enable the field of view (FOV) to be varied continuously, by adjusting the potentials at the focusing electrodes. The benefit, to system resolution, from decreasing the FOV has been characterized by measuring the modulation transfer function (MTF) of the XRII coupled to a high-resolution photo-diode array (PDA), at a number of different FOVs achieved either by electronic or optical zooming. Electronic zooming of the XRII from FOV = 24 cm to FOV = 10 cm led to an increase in f0.1 (the frequency at which MTF = 0.1) from 1.41 to 3.05 mm-1, while optical zooming increased f0.1 from 1.41 mm-1 only to 1.88 mm-1. It is proposed that the advantage, with respect to resolution gain, of electronic zooming over optical zooming was realized only when the XRII limits system resolution. The MTF of the XRII coupled to a video camera, with lower resolving power than the PDA, was measured at different FOVs to show that using electronic zooming is only marginally beneficial when the optical detector and the XRII contribute equally to the resolution degradation. However, when a higher-resolution optical detector is used, electronic zooming always yields a greater gain in resolution.

Fluoroscopy