Search PubMed⌕ Search

Biomedical subjects

M Dauzat

Publications and source records attributed to M Dauzat.

At least 37 records · Page 2Linked to original sources

[Three-dimensional reconstruction calibrated with ultrasonographic images. Application to the measurement of clot volume in vitro].

OBJECTIVE: We used 3D ultrasonographic reconstruction with manual acquisition to study the volume of venous clots in vitro. MATERIAL AND METHODS: Native 2D ultrasound slices were acquired free hand for 3D reconstruction. The spatial coordinates of each slice were delivered in real time with an electromagnetic captor. We applied a standard ultrasound protocol to test the calibrated 3D reconstruction quantitatively. The volume of 5 clots of increasing size was quantified in vitro using manual segmentation in a double-blind manner by two independent operators. RESULTS: The comparison tests and the interoperator regression lines evidenced good agreement between real and measured volumes, confirming the coherence of the reconstruction protocol and the feasibility of this technique in a routine medical setting. Intraoperator variability was 7 to 11% and interoperator variability 16.9%. CONCLUSION: This calibrated 3D reconstruction is compatible with in vitro measurement of venous clots. This technique could be useful to follow the evolution of the head of proximal deep vein thrombi in vivo. It will be more reliable with semi-automatic or even automatic segmentation becomes available.

Calibration↗

Lower limb vein enlargement and spontaneous blood flow echogenicity are normal sonographic findings during pregnancy.

PURPOSE: We studied pregnancy-induced changes in lower limb venous function. METHODS: We used plethysmography and sonography to assess the changes in venous wall distensibility, saphenous vein diameters, and spontaneous blood flow echogenicity in the common femoral veins in 190 consecutive women during and after uncomplicated pregnancies (total of 409 examinations). RESULTS: The percentage of women with clinical symptoms and signs of venous insufficiency increased significantly during pregnancy. The mean diameters of the great and small saphenous veins also increased significantly, while occlusive venous plethysmography showed a decrease in parameters indicating vein distensibility. Spontaneous blood flow echogenicity in the common femoral veins was clearly visible or marked in 6% of cases during the first trimester of pregnancy, 63% during the second trimester, and 96% during the third trimester, versus 6% after delivery (p < 0.0001). The mean hematocrit decreased and the mean fibrinogen concentration increased during pregnancy. CONCLUSIONS: The increase in lower limb venous pressure seen during pregnancy leads to venous overdistention and worsens blood stasis. Decreased venous flow velocity and rheological alterations result in increased red cell aggregation, giving rise to spontaneous blood flow echogenicity. Spontaneous blood flow echogenicity is therefore a normal finding during pregnancy and should not be mistaken for venous thrombosis.

Adult↗

CO assessment by suprasternal Doppler in critically ill patients: comparison with thermodilution.

OBJECTIVE: Comparison of suprasternal Doppler (SST) and thermodilution (TD) for the measurement of cardiac output (CO) in critically ill patients. DESIGN: Prospective study. SETTING: Intensive care unit of a university hospital. PATIENTS AND PARTICIPANTS: 65 consecutive critically ill patients requiring a pulmonary artery catheter. INTERVENTIONS: Paired CO measurements were made simultaneously using SST and TD by two independent operators. The time to obtain a CO value by SST was measured. Correlation coefficients and the linear regression equation were determined. A Bland and Altman diagram was plotted. A Bland and Altman diagram was also plotted for the level of cardiac index (CI) values (low: CI < 2.5 l min(-1) m(-2); normal: 2.5 < or = CI < or = 4.5 l min(-1) m(-2); high: CI > 4.5 l min(-1) m(-2)). MEASUREMENTS AND RESULTS: In seven patients SST failed to measure CO. In the remaining 58 patients 314 paired CO measurements were performed. The mean time to measure CO by SST was 73 +/- 45 s. The equation of linear regression was: SST(CO) = 0.84 TD(CO) + 1.39. The correlation coefficient was 0.84. The bias between SST and TD was -0.2 +/- 1.4 l min(-1). Biases were -0.23 +/- 0.50, -0.20 +/- 0.68, and 0.25 +/- 0.92 l min(-1) m(-2) for low, normal, and high levels of CI, respectively. CONCLUSION: SST does not accurately measure CO but allows a rapid assessment of CI level in critically ill patients.

Adult↗

Comparison of the diagnostic value of cardiac troponin I and T determinations for detecting early myocardial damage and the relationship with histological findings after isoprenaline-induced cardiac injury in rats.

Cardiac troponins I (cTnI) and T (cTnT) have been shown to be highly sensitive and specific markers of myocardial cell injury. The purpose of this study was to investigate the diagnostic value of cTnI and cTnT with regard to creatine kinase (CK) and lactate dehydrogenase (LD) and to determine whether they can be used for early diagnosis of myocardial damage in rats, and to examine the relationship between cTnl and cTnT release with histological examinations, using isoprenaline-induced cardiac muscle damage as an experimental model in the rat. Eighteen Wistar rats per group were treated with a single dose of either isoprenaline (iso) or with normal saline as a control group. The anti-cTnI and cTnT monoclonal antibodies (mAbs) employed in the cTnI (Access) and cTnT (Elecsys) assays cross-react with cTnI and cTnT of the rat. A highly significant rise of cTnl or cTnT was found already 2 h after iso. The time-courses of cTnI and cTnT were monophasic in form. The highest cTnI (mean+/-S.D., 1.1+/-2.3 ng/ml) and cTnT (mean+/-S.D. 3.6+/-30 ng/ml) were found 4 h after iso. cTnI and cTnT significantly increased in iso-treated rats in comparison with controls whether the differences between 2-, 4- and 6-h levels and basal levels were considered or not. The areas under cTnl and cTnT curves (AUC) (0-6 h) and the maximal cTnI and cTnT (0-6 h) after iso were significantly different from the controls. For CK and LD, no elevation in comparison with controls could be detected (except a trend for LD whether or not the difference between 6-h levels and basal levels were considered (P=0.08) and for LD AUC (0-6 h) (P=0. 059)). Correlations between maximal cTnI and cTnT and AUC were 0.69 (P=0.0001) and 0.60 (P=0.0066), respectively. Histological examinations of iso-treated rats revealed acute focal or multifocal myofibrillar degeneration of the myocardial tissue in ten out of 14 rats and showed the earliest alterations 4 h after iso in one treated rat. Only four of the controls exhibited evidence of mild changes and slight mononuclear cell infiltration. cTnl and cTnT peak values to at least 0.35 and 1.3 ng/ml, respectively, were necessary to detect histological myocardial cell injury after iso. cTnI and cTnT were found to be early markers for diagnosing iso-induced myocardial damage in comparison with CK and LD. Elevations of cTnI and cTnT appeared to relate to the severity of histologic changes after myocardial injury. Although there was a difference in the absolute concentration of results between cTnI and cTnT assays, due to a lack of standardization and heterogeneity in the cross-reactivities of mAbs to various troponin I and T forms, cTnI and cTnT can be used as easily measurable target parameters for detection of cardiotoxic and/or cardiodegenerative effects in rats.

Animals↗

Acute changes in aortic wall mechanical properties after stent placement in rabbits.

PURPOSE: To evaluate mechanical property changes after endovascular stent placement in small-diameter arteries. MATERIALS AND METHODS: Self-expanding stents (Wallstent) were placed in the infrarenal aorta of five New Zealand White rabbits via a surgical right femoral approach. Blood pressure changes (deltaP) were monitored in the aorta. Blood flow velocity was measured with a 20-MHz, pulsed Doppler probe (n = 4) to calculate the pulsatility index. Aortic diameter (dA) and diameter changes (delta(d)) were measured with a 20-MHz probe in echo-tracking mode. Diameter compliance (Cd) and distensibility coefficient (DC) were calculated as Cd = 2(delta)d/(delta)P and DC = 2delta(d)/delta(P)/dA. RESULTS: Aortic diameter increased from 3.360 +/- 0.4033 mm to 4.020 +/- 0.3033 mm after stent placement at the stent level only. Compliance decreased from 77.644 +/- 24.306 mm kPa(-1) to 31.150 +/-8.245 x 10(-3) mm kPa(-1) at the stent level, and was then significantly lower than upstream (98.500 +/- 53.196 mm kPa(-1)) and down-stream (59.047 +/- 13.833 mm kPa(-1)). There was no significant change in pulsatility index. CONCLUSIONS: Endovascular stent placement produces a significant decrease in arterial wall compliance of the rabbit abdominal aorta.

Acute-Phase Reaction↗

Antiphospholipid and antiprotein syndromes in non-thrombotic, non-autoimmune women with unexplained recurrent primary early foetal loss. The Nîmes Obstetricians and Haematologists Study--NOHA.

Various antiphospholipid and/or antiprotein antibodies have been suspected to be associated with recurrent early foetal loss in absence of any habitual aetiology. We conducted a hospital-based case control study on women with no antecedent of thromboembolic or autoimmune disease. We studied 3 groups of 518 women: patients with unexplained primary recurrent early foetal loss, patients with explained episodes and mothers with no previous obstetrical accident. Matching the 3 groups was carried out on the basis of age, number or pregnancies and time elapsed since the end of the last pregnancy. Significant biological markers were then prospectively tested. The various antibodies were shown to be dependent on parity and on the presence of previous foetal loss: cut-off values were thus calculated using data obtained from the group of explained accidents, and adjusted for parity. Only anti-phosphatidylethanolamine IgM [odds ratio: 6.0, 95% confidence interval (2.3-15.7), p = 0.0003], anti-beta2-glycoprotein I IgG [4.4, (1.6-11.7), p = 0.0035] anti-annexin V IgG antibodies [3.2 (1.2-8.1), p = 0.015] and lupus anticoagulant [3.0, (1.3-6.8), p = 0.009], were found to be independent retrospective risk factors for unexplained early foetal loss. These four markers were subsequently found to be, during the following pregnancy, associated with a significant risk of foetal loss despite a low-dose aspirin treatment. In non-thrombotic, non-auto-immune women with unexplained primary recurrent early foetal loss, subgroups of patients with positive anti-phosphatidylethanolamine IgM antibodies, or positive anti-beta2-glycoprotein-I IgG antibodies, or positive anti-annexin V IgG antibodies or lupus anticoagulant must be particularised. This should allow therapeutic trials to be carried in well-defined patients.

Abortion, Spontaneous↗

Time-course of cardiac troponin I release from isolated perfused rat hearts during hypoxia/reoxygenation and ischemia/reperfusion.

The study was designed to determine the time-course of cardiac troponin I (cTn-I) release in isolated and Langendorff-perfused rat hearts during hypoxia and reoxygenation (H/Reox), and after various durations of total ischemia and subsequent reperfusion (I/R). For this purpose, in H/Reox, cTn-I was measured with the conventional Access immunoassay (ng/ml) and a new immunoassay which operates at pg/ml, and compared with creatine kinase (CK), lactate dehydrogenase (LD) and cardiac troponin T (cTn-T). In I/R, cTn-I was compared with CK and LD. The anti-Tn-I mAbs used in cTn-I assays cross-react with cTn-I of the rat. A clear difference between time-courses and concentration levels of cTn-I in I/R and H/Reox models was found. In I/R, maximum release of cTn-I, CK and LD similarly occurred within minutes following reperfusion; however cTn-I did not return to baseline values. cTn-I levels were not linked to the duration of ischemia. In I/R, we were only able to detect small cTn-I concentrations. In H/Reox experiments, cTn-I, CK and LD increased time-dependently. We found higher cTn-I maximal peak levels detected with the Access immunoassay than with the new assay (median, 0.346 ng/ml per min/g dry wt vs 132 pg/ml per min/g dry wt). cTn-T maximal concentrations were lower than maximal cTn-I levels (median, 0.117 ng/ml per min/g dry wt). Time-courses of cTn-I release were roughly similar with both assays in the H/Reox model (r = 0.90). These data indicate that the cTn-I time-course is related to experimental model (I/R or H/Reox), but also likely depends on the sensitivity of cTn-I assays in such experimental conditions.

Animals↗

Release kinetics of cardiac troponin I and cardiac troponin T in effluents from isolated perfused rabbit hearts after graded experimental myocardial contusion.

BACKGROUND: Few experimental studies report effects of direct contusion on cardiac enzyme release. Cardiac troponins I (cTnI) and T (cTnT) have been shown to be highly sensitive and specific markers of myocardial cell injury. This investigation was designed to determine and compare the acute effects of quantified magnitudes of blunt cardiac trauma upon release of cTnI and cTnT in comparison with creatine kinase (CK) and lactate dehydrogenase (LD). METHODS: In 24 rabbit hearts prepared on a standard Langendorff apparatus, myocardial contusion (MC) was produced by a single blow with a ball falling from a predefined height, delivered directly to the surface of the heart. Hearts were divided into control (n = 6) and various quantified impacts: 75 mJoules (mJ) (n = 6), 100 mJ (n = 6), 200 mJ (n = 6). Coronary effluent samples for cTnI, cTnT, CK, and LD were collected at baseline, immediately after MC and 5, 15, 30, 45, and 60 minutes after MC. At the end of experiment, histologic condition was evaluated. RESULTS: The anti-cTnI and cTnT MAbs used in the cTnI (Access) and cTnT (Elecsys) assays cross-react with cTnI and cTnT of the rabbit. The time-courses of cTnI, cTnT, CK, and LD were monophasic in form. After MC, all parameters rose significantly compared with baseline and with control group. The maximal release occurred immediately after MC. The area under the cTnI curve and the maximal cTnI concentration were linked to the contusion energy when increased at 200 mJ. Maximal concentrations and areas under cTnT, CK, LD time activity curve were not linked to the contusion energy level and showed no between-energy group differences. The correlation found between maximal cTnI and maximal cTnT concentrations was 0.70 (p = 0.0001). Histologic examination showed cellular disruption and after the more severe impact, the extent of pathologic changes was more extensive. CONCLUSION: After graded experimental MC, maximal cTnI concentration and area under cTnI curve increase with the power of impact kinetic energy. Levels of cTnI allow a much higher accuracy in detecting the extent of myocardial injury postMC in comparison with cTnT, CK, and LD in this experimental study. These results should be consistent with the more extensive cTnI release with more severe impact in patients with blunt chest trauma. Furthermore, because specificity and time-course of release, both cTnI and cTnT should have a role in the diagnosis and evaluation of such patients.

Animals↗

Short- and medium-term duplex sonography follow-up of deep venous thrombosis of the lower limbs.

PURPOSE: We conducted this study to assess the progression or regression of venous thrombi during and after treatment and to search for criteria of embolism risk. METHODS: We prospectively studied 75 patients with lower limb deep venous thrombosis. We used B-mode sonography for the diagnosis and follow-up of these thrombi. Pulmonary scintigraphy was performed at days 1 and 10. We evaluated the topography, echogenicity, and structure of the thrombus; the location and wall attachment of its head; and the vein diameter. Each venous segment was semiquantitatively scored as follows: 0, no thrombosis; 1, partially obstructive thrombosis; or 2, complete thrombosis. RESULTS: The decreases in the total thrombosis score were 4%, 11%, 51%, 72%, and 84% on days 5, 10, 30, 90, and 365 (1 year), respectively. Pulmonary embolism occurred in 27 patients, of whom 16 were asymptomatic. Thrombi in iliac veins exhibited a slower regression rate than those in calf and femoral veins. Pulmonary embolism occurred in 54% of patients with versus 24% of patients without a floating thrombus head. CONCLUSIONS: Sonography is useful for the early detection of thrombus progression and the evaluation of embolism risk, which seems to be greater in patients with a floating thrombus head.

Disease Progression↗

Doppler study of mesenteric, hepatic, and portal circulation in alcoholic cirrhosis: relationship between quantitative Doppler measurements and the severity of portal hypertension and hepatic failure.

To determine the relationship between quantitative Doppler parameters of portal, hepatic, and splanchnic circulation and hepatic venous pressure gradient (HVPG), variceal size, and Child-Pugh class in patients with alcoholic cirrhosis, we studied forty patients with proved alcoholic cirrhosis who underwent Doppler ultrasonography, hepatic vein catheterization, and esophagoscopy. The following Doppler parameters were recorded: time-averaged mean blood velocity, volume flow of the main portal vein flow, and resistance index (RI) of the hepatic and of the superior mesenteric artery. Doppler findings were compared with HVPG, presence and size of esophageal varices, and Child-Pugh class. There was a significant inverse correlation between portal velocity and HVPG (r = -.69), as well as between portal vein flow and HVPG (r = -.58). No correlation was found between RI in the hepatic artery or superior mesenteric artery and HVPG. No correlation was found between portal vein measurements and presence and size of varices. Severe liver failure was associated with lower portal velocity and flow. In patients with alcoholic cirrhosis, only portal vein blood velocity and flow, but neither hepatic nor mesenteric artery RI, are correlated to the severity of portal hypertension and to the severity of liver failure.

Adult↗

Training is required to improve the reliability of esophageal Doppler to measure cardiac output in critically ill patients.

OBJECTIVES: Assessment of and effect of training on reliability of esophageal Doppler (ED) versus thermodilution (TD) for cardiac output (CO) measurement. DESIGN: Prospective study. SETTING: Intensive care unit of a university hospital. PATIENTS: 64 consecutive critically ill patients requiring a pulmonary artery catheter, sedation, and mechanical ventilation. INTERVENTIONS: Esophageal Doppler CO measurements were performed by the same operator, whereas TD CO measurements were carried out by other independent operators. A training period involving the first 12 patients made the operator self-confident. In the remaining patients, the reliability of ED was assessed (evaluation period), using correlation coefficients and the Bland and Altman diagram. Between training and evaluation periods, correlation coefficients, biases, and limits of agreement were compared. MEASUREMENTS AND RESULTS: During training and evaluation periods, 107 and 320 CO measurements were performed in 11 out of 12 patients and in 49 out of 52 patients, respectively. Continuous CO monitoring was achieved in 6 out of 11 patients and in 38 out of 49 patients during training and evaluation periods, respectively. Between the two periods, correlation coefficients increased from 0.53 to 0.89 (p < 0.001), bias decreased from 1.2 to 0.1 l x min(-1) (p < 0.001), and limits of agreement decreased from 3.2 to 2.2 l x min(-1) (p < 0.001). CONCLUSION: A period of training involving no more than 12 patients is probably required to ensure reliability of CO measurement by ED.

Aged↗

Can cerebrovascular microemboli induce cognitive impairment in patients with prosthetic heart valves?

Doppler ultrasonography can be used to detect the presence of emboli in the cerebral arterial circulation. Emboli can be produced by different sources and can be of different nature: solid elements as thrombi, platelet aggregates or atheromatous material, or gaseous when they are produced during the decompression phase of diving or during extracorporeal circulation (ECC) procedures. A more recent source of emboli has been found in the mechanical prostheic heart valves (MHV). The emboli generated by MHV are likely of gaseous nature and are found in the middle cerebral artery blood flow at a variable rate, where they are detected by transcranial Doppler sonography. The mechanism of production of these microbubbles may be related to the rapid leaflet motion especially at closure when very high local pressure gradients appear, which may be able to provoke a release of the disolved blood gas. Solid element emboli constitute a major cause of cerebrovascular disease and particularly stroke. Conversely, gaseous emboli coming from ECC or MHV are considered as clinically silent. Nevertheless, cognitive alterations have been reported after ECC. As the MHV carriers are chronically submitted to embolic events, it can be assumed that cognitive impairments may occur also in these patients. A preliminary study was designed to inpatients attention and memory in patients with normally functioning MHV and microemboli, with biological prosthesis and in normal subjects. In the two groups of patients, episodic memory was significantly altered relatively to the control group. In the MHV carriers group, a significant decrease in working memory performance was observed relatively to the two other groups. These results confirm a long term effect of the microembolization occuring during ECC and point out the effect of the chronic exposition to microemboli.

Bioprosthesis↗

Pulsed Doppler ultrasonography guidance for catheterization of the subclavian vein: a randomized study.

BACKGROUND: Catheterization of the subclavian vein may lead to severe complications. The current randomized study compared a technique of pulsed Doppler ultrasonography guidance and the standard method for subclavian vein catheterization. METHODS: Standard and Doppler ultrasonography guidance methods were performed by the same physician in 286 patients, 143 in each group. Primary end points were immediate complications (arterial puncture, pneumothorax, wrong position of catheter tip), failures, the number of subclavian vein catheterizations with immediate complication or failure, the number of skin punctures per catheterization, and the time to placement of the guide wire. The secondary end points were the determination of predicting factors of successful cannulation in each group. RESULTS: Both groups were similar according to morphologic parameters of the patients. A greater number of subclavian vein catheterizations were performed on the right side using Doppler guidance (105 vs. 73, P < 0.01). Doppler guidance decreased complications (5.6% vs. 16.8%, P < 0.01), largely because of a smaller number of catheters for which the tip was defined to be in incorrect position (0.7% vs. 7.7%, P < 0.01). The time to catheterization was longer with Doppler guidance (300 vs. 27 s, P < 0.001). Failures, catheterizations of the subclavian vein with immediate complications or failure, and the total number of skin punctures per catheterization were similar in both groups. Using Doppler guidance, the presence of a good Doppler signal (124 of 143) was predictive of successful catheterization (123 successful cannulations, P < 0.001). CONCLUSIONS: Doppler guidance reduces the incidence of inappropriately positioned subclavian catheters.

Adult↗

Diagnosis of acute lower limb deep venous thrombosis with ultrasound: trends and controversies.

Acute deep venous thrombosis of the lower limb is a common and threatening condition whose clinical diagnosis is known to be unreliable. Sonography has gradually superseded venography as the primary diagnostic procedure. A review of the medical literature shows that sonography offers a high level of sensitivity and specificity in symptomatic patients but suffers from a lack of sensitivity at the calf level and in asymptomatic patients. Technologic progress, as well as increased operator experience, may improve sensitivity. Nevertheless, several critical issues remain unresolved, such as the significance of free-floating thrombi, the usefulness of calf and bilateral examination, the criteria that are essential to the diagnosis, the risk of compression sonography, and sonography's role in the direct detection of venous emboli.

Acute Disease↗

Non-invasive quantification of diaphragm kinetics using m-mode sonography.

PURPOSE: The standard conditions of spirometry (i.e., wearing a noseclip and breathing through a mouthpiece and a pneumotachograph) are likely to alter the ventilatory pattern. We used "time motion" mode (M-mode) sonography to assess the changes in diaphragm kinetics induced by spirometry during quiet breathing. METHODS: An M-mode sonographic study of the right diaphragm was performed before and during standard spirometry in eight patients without respiratory disease (age 34 to 68 yr). RESULTS: During spirometry, the diaphragm inspiratory amplitude (DIA) increased from 1.34 +/- 0.18 cm to 1.80 +/- 0.18 cm (P = 0.007), whereas the diaphragmatic inspiratory (T1 diaph) increased from 1.27 +/- 0.15 to 1.53 +/- 0.23 sec, (P = 0.015, without change in diaphragmatic total time interval (Ttot diaph). Therefore, the diaphragm duty cycle (T1 diaph/Ttot diaph) increased from 38% +/- 1% to 44% +/- 4% (P = 0.023). The diaphragm inspiratory (DIV) and expiratory (DEV) motion velocity (P = 0.007). CONCLUSION: M-mode sonography enabled us to demonstrate that the wearing of a nose clip and breathing through a mouthpiece and a pneumotachograph induce measurable changes in diaphragm kinetics.

Adult↗